907 resultados para Rigid fixation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to perform a physicochemical and morphological characterization and compare the mechanical behavior of an experimental Ti-Mo alloy to the analogous metallic Ti-based fixation system, for mandibular angle fractures. Twenty-eight polyurethane mandibles were uniformly sectioned on the left angle. These were divided into 4 groups: group Eng 1P, one 2.0-mm plate and 4 screws 6 mm long; group Eng 2P, two 2.0-mm plates, the first fixed with 4 screws 6 mm long and the second with 4 screws 12 mm long. The same groups were created for the Ti-15Mo alloy. Each group was subjected to linear vertical loading at the first molar on the plated side in a mechanical testing unit. Means and standard deviations were compared with respect to statistical significance using ANOVA. The chemical composition of the Ti-15Mo alloy was close to the nominal value. The mapping of Mo and Ti showed a homogeneous distribution. SEM of the screw revealed machining debris. For the plates, only the cpTi plate undergoes a surface treatment. The metallographic analysis reveals granular microstructure, from the thermomechanical trials. A statistically significant difference was found (P < 0.05) when the comparison between both internal fixation techniques was performed. The 2P technique showed better mechanical behavior than 1P.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study analyzes the repair process of autogenous bone graft in a block fixed with ethyl cyanoacrylate and 2-octyl cyanoacrylate adhesives in rat calvaria. Forty-eight rats, divided into 3 groups, received round osteotomies at the right parietal bone for the attainment of autogenous bone graft fragment, which was fixed at the opposite side to the donor site with ethyl cyanoacrylate (ethyl group) and 2-octyl cyanoacrylate (octyl group) adhesives. In the control group, bone fragment was only juxtaposed at the parietal bone surface without any fixation material. The animals were euthanized after 10 and 60 postoperative days. The calvariae were processed in a laboratory for the attainment of slides stained through the hematoxylin and eosin technique for histological and histometric analysis. The qualitative analysis showed a discrete inflammatory infiltrate in the control group and moderate inflammatory infiltrate in the ethyl and octyl groups at the 10-day period, which remained at the 60-day period, mainly in the octyl group. The bone fragment remained bonded to the recipient site through the adhesive, but graft incorporation was not observed in any of the specimens. Resorption was higher in the octyl group followed by the ethyl and control groups, both at the 10-and 60-day periods, but with no statistical significance (P < .05). Although promoting graft fixation and its maintenance at the recipient site, both studied adhesives did not allow the graft incorporation, producing a localized and discrete inflammatory reaction, which persisted at 60 days, being more intense in the octyl cyanoacrylate group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to analyze the etiology, type and treatment employed in the orbito-zygomatic fractures (OZ). Also, postoperative complications are described and correlated with the type of treatment used. Fifty patients with OZ fractures were evaluated. Orbital fractures in which the zygomatic bone was not involved were excluded. Epidemiologic data and characteristics of treatment such as the type of material used for osteosynthesis, number of anatomical sites on which rigid internal fixation (RIF) was applied, surgical approaches and associated complications were recorded. The main causes of trauma were motorcycle and bicycle accidents, constituting 52% of the sample. The osteosynthesis system used was the 2.0 mm, except in four patients in whom the 1.5mm system was used for fixation at the infra-orbital rim. A total of 18% of the patients required reconstruction of the internal orbit and in all cases titanium mesh was used. 46% of the patients received RIF in three anatomical sites, most in the fronto-zygomatic suture, infra-orbital rim and zygomatic-maxillary buttress. The most frequent complication was paresthesia of the infra-orbital nerve (34 patients, 68%). Other findings were also discussed with the intent of better understanding the treatment of the OZ fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study aims to compare three types of internal fixation for fractures of the mandibular angle. Mechanical testing was performed on replicas of polyurethane hemimandibles sectioned at the angle region to simulate a fracture and fixed with three different hardwares. Fixation devices enrolled on this survey included the grid plates with and without an intermediate bar and the method described by Champy and colleagues in 1978 and the sample consisted of 10 hemimandibles for each group. Vertical loadings were applied on each hemimandible and recorded after a vertical displacement of 3 and 5 mm. Statistical analysis was made by means of the variance analysis (ANOVA) and the Duncan test with a significance level of 5%. The Champy technique showed a statistically significant increased resistance when compared to the grid plates after vertical displacements of 3 and 5 mm. The results of this survey suggest that the Champy technique, when compared to the grid plate positioned at the middle of the mandibular bone (placement site selected for this study), is more resistant than the grid plate and that the inclusion or not of an intermediate bar to the grid plates does not improve its resistance after linear vertical loadings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background This multicentre study aimed to investigate long-term radiographic and functional results following the treatment of condylar fractures using an angulated screwdriver system and open rigid internal fixation with an intraoral surgical approach. Methods Twenty-nine patients with a total of 32 condylar fractures were evaluated. The patients were investigated prospectively based on the following variables: age, sex, aetiology, side, location and classification of the fracture, degree of displacement, associated fractures, surgical approach, oral health status, type of osteosynthesis plate, duration of surgery, mouth-opening, complications, and duration of follow-up. Results The fractures were classified as subcondylar (n = 25) or condylar neck (n = 7). Mean patient age was 36.38 ± 16.60 years. The median duration of postoperative follow-up was 24.39 ± 13.94 months. No joint noise, weakness of the facial nerve, joint pain, or muscle pain was observed. An additional retromandibular approach was necessary to enable the treatment of one subcondylar fracture with medial displacement. Conclusion Subcondylar or condylar neck fractures with medial or lateral displacement can be treated using an intraoral approach with satisfactory results with the advantages of the absence of visible scarring, the avoidance of facial nerve injury, and the ability to obtain rapid access to the fracture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective The objective of this article is to present options of rehabilitation with dental implants in two cases of severely atrophic mandibles (<10 mm) after rigid internal fixation of fractures. Patients and method Two patients who sustained fractures in severely atrophic mandibles with less than 10 mm of bone height were treated by open reduction and internal fixation through a transcervical access. Internal fixation was obtained with 2.4-mm locking reconstruction plates. The first patient presented satisfactory bone height at the area between the mental foramens and after 2 years, received flapless guided implants in the anterior mandible and an immediate protocol prosthesis. The second patient received a tent pole iliac crest autogenous graft after 2 years of fracture treatment and immediate implants. After 5 months, a protocol prosthesis was installed in the second patient. Results In both cases, the internal fixation followed AO principles for load-bearing osteosynthesis. Both prosthetic devices were Branemark protocol prosthesis. The mandibular reconstruction plates were not removed. Both patients are rehabilitated without complications and satisfied with esthetic and functional results. Conclusion With the current techniques of internal fixation, grafting, and guided implants, the treatment of atrophic mandible fractures can achieve very good results, which were previously not possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osseointegration involves a cascade of biological events, which can be accelerated by modifying the micro and/or nanometric topography of dental implant surfaces. Considering that different treatment types modify the titanium surface giving it a more pronounced rough topography, and physicochemical changes that appear to positively influence the osseointegration process, a literature review was made on the main types of surface treatments and their influence on the biological and cellular aspects of osseointegration, with publications dating from 1969 until the present moment. Although the precise role of the implant surface on the osseointegration of dental implants is not completely clear, the specific effects of implant surface on bone regeneration, initial kinetics, and evolution of mechanical properties have shown to be quite promising. Thus, based on dental implant surface modifications, osseointegration can be defined as a process by which rigid asymptomatic fixation of an alloplastic material can be achieved and kept in close contact with bone tissue, being resistant to early and late functional loads. This process can be modulated by an appropriate treatment of the alloplastic material surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: This multicentre study aimed to investigate long-term radiographic and functional results following the treatment of condylar fractures using an angulated screwdriver system and open rigid internal fixation with an intraoral surgical approach.Methods: Twenty-nine patients with a total of 32 condylar fractures were evaluated. The patients were investigated prospectively based on the following variables: age, sex, aetiology, side, location and classification of the fracture, degree of displacement, associated fractures, surgical approach, oral health status, type of osteosynthesis plate, duration of surgery, mouth-opening, complications, and duration of follow-up.Results: The fractures were classified as subcondylar (n = 25) or condylar neck (n = 7). Mean patient age was 36.38 +/- 16.60 years. The median duration of postoperative follow-up was 24.39 +/- 13.94 months. No joint noise, weakness of the facial nerve, joint pain, or muscle pain was observed. An additional retromandibular approach was necessary to enable the treatment of one subcondylar fracture with medial displacement.Conclusion: Subcondylar or condylar neck fractures with medial or lateral displacement can be treated using an intraoral approach with satisfactory results with the advantages of the absence of visible scarring, the avoidance of facial nerve injury, and the ability to obtain rapid access to the fracture. (C) 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to analyze, through Vickers hardness test and photoelasticity analysis, pre-bent areas, manually bent areas, and areas without bends of 10-mm advancement pre-bent titanium plates (Leibinger system). The work was divided into three groups: group I-region without bend, group II-region of 90° manual bend, and group III-region of 90° pre-fabricated bends. All the materials were evaluated through hardness analysis by the Vickers hardness test, stress analysis by residual images obtained in a polariscope, and photoelastic analysis by reflection during the manual bending. The data obtained from the hardness tests were statistically analyzed using ANOVA and Tukey's tests at a significance level of 5 %. The pre-bent plate (group III) showed hardness means statistically significantly higher (P < 0.05) than those of the other groups (I-region without bends, II-90° manually bent region). Through the study of photoelastic reflection, it was possible to identify that the stress gradually increased, reaching a pink color (1.81 δ / λ), as the bending was performed. A general analysis of the results showed that the bent plate region of pre-bent titanium presented the best results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The treatment of mandibular fractures has undergone many changes, especially after the introduction of rigid internal fixation techniques. Currently, the use of resorbable materials presents some advantages over metallic devices, particularly when applied in children. Objective: The authors discuss the controversies involved in the treatment of mandibular fractures in children, mainly related to fixation of fractures. Case Report: In this paper, we present a case of a 5 years treatment patient with mandibular angle fracture treated by open reduction and internal fixation with plates and screws. Final Comments: Aiming to not interfere in the development of tooth germs and mandibular bone growth a second surgery for removal of the fixation devices is indicated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Saccadic eye movements have been shown to affect posture by decreasing the magnitude of body sway in young adults. However, there is no evidence of how the search for visual information that occurs during eye movements affects postural control in older adults. The purpose of the present study was to determine the influence of saccadic eye movements on postural control in older adults while they stood on 2 different bases of support. Twelve older adults stood upright in 70-s trials under 2 stance conditions (wide and narrow) and 3 gaze conditions (fixation, saccadic eye movements at 0.5 Hz, and saccadic eye movements at 1.1 Hz). Head and trunk sway amplitude and mean sway frequency were measured in both the anterior/posterior (AP) and medial/lateral (ML) directions. The results showed that the amplitude of body sway was reduced during saccades compared with fixation, as previously observed in young adults. However, older adults exhibited similar sway amplitude and frequency in the AP direction under the wide and narrow stance conditions, which is different from observations in young adults, who display larger sway in a narrow stance compared with a wide stance while performing saccades. These results suggest that although older adults are affected by saccadic eye movements by a decrease in the amplitude of body sway, as observed in young adults, they present a more rigid postural control strategy that does not allow larger sway during a more challenging stance condition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Among the osteotomies performed in orthognathic surgery, the sagittal osteotomy of the mandibular ramus (SOMR) is the most common, allowing a great range of movements and stable internal fixation (SIF), therefore eliminating the need of maxillomandibular block in the postoperative period. Objectives: The purpose of this study was to evaluate the biomechanical resistance of three national systems used for SIF in SOMR in sheep mandibles. Material and methods: The study was performed in 30 sheep hemi-mandibles randomly divided into 3 experimental groups, each containing 10 hemi-mandibles. The samples were measured to avoid discrepancies and then subjected to SOMR with 5-mm advancement. In group I, 2.0x12 mm screws were used for fixation, inserted in an inverted "L" pattern (inverted "L" group). In group II, fixation was performed with two 2.0x12 mm screws, positioned in a linear pattern and a 4-hole straight miniplate and four 2.0x6.0 mm monocortical screws (hybrid group). In group III, fixation was performed with two-hole straight miniplates and eight 2.0x6.0 mm monocortical screws (mini plate group). All materials used for SIF were supplied by Osteosin - SIN. The hemimandibles were subjected to vertical linear load test by Kratos K2000MP mechanical testing unit for loading registration and displacement. Results: All groups showed similar resistance during mechanical test for loading and displacement, with no statistically significant differences between groups according to analysis of variance. Conclusion: These results indicate that the three techniques of fixation are equally effective for clinical fixation of SOMR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bars and steel wires are the most commonly used methods to achieve maxillomandibular fixation, although there are numerous alternatives described for this same purpose. In cases of edentulous candidates for the conservative treatment of facial fractures, none of the conventional methods can be instituted for maxillomandibular fixation. Fixation in such cases is achieved with the aid of the total dentures of the patient or the confection of splints, but these methods lead to eating and oral hygiene problems. This article reports the case of an edentulous patient with a comminuted mandible fracture treated with a rarely described technique in which intermaxillary fixation was achieved with titanium miniplates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To describe a new method for iris fixation of intraocular lens in the absence of capsular support during penetrating keratoplasty. Its a new technique of iris fixation of intraocular lens without capsular support during penetrating keratoplasty. This technique is used in cases with a healthy iris and partial or total absence of capsular support during penetrating keratoplasty. Tied Out Open Sky is a technique easy to perform for iris fixation of intraocular lens during penetrating keratoplasty. The big advantage is being able to tie off the intraocular lens off the eye and fasten it securely.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to compare the bone repair along a mandibular body osteotomy stabilized with 2.0 mm absorbable and metallic systems. 12 male, adult mongrel dogs were divided into two groups (metallic and absorbable) and subjected to unilateral osteotomy between the mandibular third and fourth premolars, which was stabilized by applying two 4-hole plates. At 2 and 18 weeks, three dogs from each group were killed and the osteotomy sites were removed and divided equally into three parts: the upper part was labelled the tension third (TT), the lower part the compression third (CT), and the part between the TT and CT the intermediary third (IT). Regardless of the treatment system, union between the fragments was observed at 18 weeks and the CT showed more advanced stages of bone repair than the TT. Histometric analysis did not reveal any significant differences among the 3 parts or systems in the distance between bone fragments at 2 weeks. Although at 18 weeks the proportions of newly formed bone did not differ among TT, IT and CT, significantly enhanced bone formation was observed in all sections for the metallic group. The patterns of repair were distinct between treatments.