890 resultados para Rapid Opiate Detoxification
Resumo:
We assessed knee extensor neuromuscular adjustments following repeated treadmill sprints in different normobaric hypoxia conditions, with special reference to rapid muscle torque production capacity. Thirteen team- and racquet-sport athletes undertook 8 × 5-s "all-out" sprints (passive recovery = 25 s) on a non-motorized treadmill in normoxia (NM; FiO2 = 20.9%), at low (LA; FiO2 = 16.8%) and high (HA; FiO2 = 13.3%) normobaric hypoxia (simulated altitudes of ~1800 m and ~3600 m, respectively). Explosive (~1 s; "fast" instruction) and maximal (~5 s; "hard" instruction) voluntary isometric contractions (MVC) of the knee extensors (KE), with concurrent electromyographic (EMG) activity recordings of the vastus lateralis (VL) and rectus femoris (RF) muscles, were performed before and 1-min post-exercise. Rate of torque development (RTD) and EMG (i.e., Root Mean Square or RMS) rise from 0 to 30, -50, -100, and -200 ms were recorded, and were also normalized to maximal torque and EMG values, respectively. Distance covered during the first 5-s sprint was similar (P > 0.05) in all conditions. A larger (P < 0.05) sprint decrement score and a shorter (P < 0.05) cumulated distance covered over the eight sprints occurred in HA (-8 ± 4% and 178 ± 11 m) but not in LA (-7 ± 3% and 181 ± 10 m) compared to NM (-5 ± 2% and 183 ± 9 m). Compared to NM (-9 ± 7%), a larger (P < 0.05) reduction in MVC torque occurred post-exercise in HA (-14 ± 9%) but not in LA (-12 ± 7%), with no difference between NM and LA (P > 0.05). Irrespectively of condition (P > 0.05), peak RTD (-6 ± 11%; P < 0.05), and normalized peak RMS activity for VL (-8 ± 11%; P = 0.07) and RF (-14 ± 11%; P < 0.01) muscles were reduced post-exercise, whereas reductions (P < 0.05) in absolute RTD occurred within the 0-100 (-8 ± 9%) and 0-200 ms (-10 ± 8%) epochs after contraction onset. After normalization to MVC torque, there was no difference in RTD values. Additionally, the EMG rise for VL muscle was similar (P > 0.05), whereas it increased (P < 0.05) for RF muscle during all epochs post-exercise, independently of the conditions. In summary, alteration in repeated-sprint ability and post-exercise MVC decrease were greater at high altitude than in normoxia or at low altitude. However, the post-exercise alterations in RTD were similar between normoxia and low-to-high hypoxia.
Resumo:
Bloodstream infections and sepsis are a major cause of morbidity and mortality. The successful outcome of patients suffering from bacteremia depends on a rapid identification of the infectious agent to guide optimal antibiotic treatment. The analysis of Gram stains from positive blood culture can be rapidly conducted and already significantly impact the antibiotic regimen. However, the accurate identification of the infectious agent is still required to establish the optimal targeted treatment. We present here a simple and fast bacterial pellet preparation from a positive blood culture that can be used as a sample for several essential downstream applications such as identification by MALDI-TOF MS, antibiotic susceptibility testing (AST) by disc diffusion assay or automated AST systems and by automated PCR-based diagnostic testing. The performance of these different identification and AST systems applied directly on the blood culture bacterial pellets is very similar to the performance normally obtained from isolated colonies grown on agar plates. Compared to conventional approaches, the rapid acquisition of a bacterial pellet significantly reduces the time to report both identification and AST. Thus, following blood culture positivity, identification by MALDI-TOF can be reported within less than 1 hr whereas results of AST by automated AST systems or disc diffusion assays within 8 to 18 hr, respectively. Similarly, the results of a rapid PCR-based assay can be communicated to the clinicians less than 2 hr following the report of a bacteremia. Together, these results demonstrate that the rapid preparation of a blood culture bacterial pellet has a significant impact on the identification and AST turnaround time and thus on the successful outcome of patients suffering from bloodstream infections.
Resumo:
The truncated hemoglobin N, HbN, of Mycobacterium tuberculosis is endowed with a potent nitric oxide dioxygenase (NOD) activity that allows it to relieve nitrosative stress and enhance in vivo survival of its host. Despite its small size, the protein matrix of HbN hosts a two-branched tunnel, consisting of orthogonal short and long channels, that connects the heme active site to the protein surface. A novel dual-path mechanism has been suggested to drive migration of O(2) and NO to the distal heme cavity. While oxygen migrates mainly by the short path, a ligand-induced conformational change regulates opening of the long tunnel branch for NO, via a phenylalanine (PheE15) residue that acts as a gate. Site-directed mutagenesis and molecular simulations have been used to examine the gating role played by PheE15 in modulating the NOD function of HbN. Mutants carrying replacement of PheE15 with alanine, isoleucine, tyrosine and tryptophan have similar O(2)/CO association kinetics, but display significant reduction in their NOD function. Molecular simulations substantiated that mutation at the PheE15 gate confers significant changes in the long tunnel, and therefore may affect the migration of ligands. These results support the pivotal role of PheE15 gate in modulating the diffusion of NO via the long tunnel branch in the oxygenated protein, and hence the NOD function of HbN.
Resumo:
The central goal of food safety policy in the European Union (EU) is to protect consumer health by guaranteeing a high level of food safety throughout the food chain. This goal can in part be achieved by testing foodstuffs for the presence of various chemical and biological hazards. The aim of this study was to facilitate food safety testing by providing rapid and user-friendly methods for the detection of particular food-related hazards. Heterogeneous competitive time-resolved fluoroimmunoassays were developed for the detection of selected veterinary residues, that is coccidiostat residues, in eggs and chicken liver. After a simplified sample preparation procedure, the immunoassays were performed either in manual format with dissociation-enhanced measurement or in automated format with pre-dried assay reagents and surface measurement. Although the assays were primarily designed for screening purposes providing only qualitative results, they could also be used in a quantitative mode. All the developed assays had good performance characteristics enabling reliable screening of samples at concentration levels required by the authorities. A novel polymerase chain reaction (PCR)-based assay system was developed for the detection of Salmonella spp. in food. The sample preparation included a short non-selective pre-enrichment step, after which the target cells were collected with immunomagnetic beads and applied to PCR reaction vessels containing all the reagents required for the assay in dry form. The homogeneous PCR assay was performed with a novel instrument platform, GenomEra™, and the qualitative assay results were automatically interpreted based on end-point time-resolved fluorescence measurements and cut-off values. The assay was validated using various food matrices spiked with sub-lethally injured Salmonella cells at levels of 1-10 colony forming units (CFU)/25 g of food. The main advantage of the system was the exceptionally short time to result; the entire process starting from the pre-enrichment and ending with the PCR result could be completed in eight hours. In conclusion, molecular methods using state-of-the-art assay techniques were developed for food safety testing. The combination of time-resolved fluorescence detection and ready-to-use reagents enabled sensitive assays easily amenable to automation. Consequently, together with the simplified sample preparation, these methods could prove to be applicable in routine testing.
Resumo:
Language acquisition is a complex process that requires the synergic involvement of different cognitive functions, which include extracting and storing the words of the language and their embedded rules for progressive acquisition of grammatical information. As has been shown in other fields that study learning processes, synchronization mechanisms between neuronal assemblies might have a key role during language learning. In particular, studying these dynamics may help uncover whether different oscillatory patterns sustain more item-based learning of words and rule-based learning from speech input. Therefore, we tracked the modulation of oscillatory neural activity during the initial exposure to an artificial language, which contained embedded rules. We analyzed both spectral power variations, as a measure of local neuronal ensemble synchronization, as well as phase coherence patterns, as an index of the long-range coordination of these local groups of neurons. Synchronized activity in the gamma band (2040 Hz), previously reported to be related to the engagement of selective attention, showed a clear dissociation of local power and phase coherence between distant regions. In this frequency range, local synchrony characterized the subjects who were focused on word identification and was accompanied by increased coherence in the theta band (48 Hz). Only those subjects who were able to learn the embedded rules showed increased gamma band phase coherence between frontal, temporal, and parietal regions.
Resumo:
Introduction: The aim of this study was to describe breast ductal cancer in situ (DCIS) incidence trends in women in the Girona province during a period of 25 years. The influence of age, use of mammography and implementation of the breast cancer screening programs was explored. Incidence of subsequent invasive breast cancers (IBC) and DCIS treatment was also considered. Materials and Methods: Cases diagnosed with primary pure DCIS (n=416) during 1983-2007 were extracted from the population-based Girona Cancer Registry. The estimated annual percent change was estimated using joinpoint analysis. Results: DCIS incidence showed a sharp rise until 1998, followed by a less marked upward trend. Among women aged 50-69 the increase was particularly important between 1992 and in 1996, reflecting the spread in mammography use. Conclusion: The upward trend of DCIS was mainly related to an increase in mammography use either opportunistic or as a result of screening implementation
Resumo:
Aikuispotilaan kotisyntyisen keuhkokuumeen etiologinen diagnostiikka mikrobiologisilla pikamenetelmillä Tausta. Keuhkokuume on vakava sairaus, johon sairastuu Suomessa vuosittain n. 60 000 aikuista. Huolimatta siitä, että taudin hoito on kehittynyt, siihen liittyy yhä merkittävä, 6-15%:n kuolleisuus. Alahengitystieinfektion aiheuttajamikrobien tunnistaminen on myös edelleen haasteellista. Tavoitteet. Tämän työn tavoitteena oli tutkia Turun yliopistollisessa keskussairaalassa hoidettujen aikuispotilaiden keuhkokuumeen etiologiaa sekä selvittää uusien mikrobiologisten pikamenetelmi¬en hyödyllisyyttä taudinaiheuttajan toteamisessa. Aineisto. Osatöiden I ja III aineisto koostui 384 Turun yliopistollisen keskussairaalaan infektio-osastolla hoidetusta keuhkokuumepotilaasta. Osatyössä I tutkittiin keuhkokuumeen aiheuttaja¬mikrobeja käyttämällä perinteisten menetelmien lisäksi antigeeniosoitukseen ja PCR-tekniikkaan perustuvia pikamenetelmiä. Osatyö II käsitti 231 potilaasta koostuvan alaryhmän, jossa tutkittiin potilaiden nielun limanäytteestä rinovirusten ja enterovirusten esiintyvyyttä. Osatyössä III potilailta tutkittiin plasman C-reaktiivisen proteiinin (CRP) pitoisuus ensimmäisten viiden sairaalahoitopäi¬vän aikana. Laajoja tilastotieteellisiä analyysejä käyttämällä selvitettiin CRP:n käyttökelpoisuutta sairauden vaikeusasteen arvioinnissa ja komplikaatioiden kehittymisen ennustamisessa. Osatyössä IV 68 keuhkokuumepotilaan sairaalaan tulovaiheessa otetuista näytteistä määritettiin neutrofiilien pintareseptorien ekspressio. Osatyössä V analysoitiin sisätautien vuodeosastoilla vuosina 1996-2000 keuhkokuumepotilaille tehtyjen keuhkohuuhtelunäytteiden laboratoriotutkimustulokset. Tulokset. Keuhkokuumeen aiheuttaja löytyi 209 potilaalta, aiheuttajamikrobeja löydettiin kaikkiaan 230. Näistä aiheuttajista 135 (58.7%) löydettiin antigeenin osoituksella tai PCR-menetelmillä. Suu¬rin osa, 95 (70.4%), todettiin pelkästään kyseisillä pikamenetelmillä. Respiratorinen virus todettiin antigeeniosoituksella 11.1% keuhkokuumepotilaalla. Eniten respiratorisia viruksia löytyi vakavaa keuhkokuumetta sairastavilta potilailta (20.3%). 231 keuhkokuumepotilaan alaryhmässä todettiin PCR-menetelmällä picornavirus 19 (8.2%) potilaalla. Respiratorinen virus löytyi tässä potilasryh¬mässä kaiken kaikkiaan 47 (20%) potilaalta. Näistä 17:llä (36%) löytyi samanaikaisesti bakteerin aiheuttama infektio. CRP-tasot olivat sairaalaan tulovaiheessa merkitsevästi korkeammat vakavaa keuhkokuumetta (PSI-luokat III-V) sairastavilla potilailla kuin lievää keuhkokuumetta (PSI-luokat I-II) sairastavilla potilailla (p <0.001). Yli 100 mg/l oleva CRP-taso neljän päivän kuluttua sairaa¬laan tulosta ennusti keuhkokuumeen komplikaatiota tai huonoa hoitovastetta. Neutrofiilien komple¬menttireseptorin ekspressio oli pneumokokin aiheuttamaa keuhkokuumetta sairastavilla merkitse¬västi korkeampi kuin influenssan aiheuttamaa keuhkokuumetta sairastavilla. BAL-näytteistä vain yhdessä 71:stä (1.3%) todettiin diagnostinen bakteerikasvu kvantitatiivisessa viljelyssä. Uusilla menetelmilläkin keuhkokuumeen aiheuttaja löytyi vain 9.8% BAL-näytteistä. Päätelmät. Uusilla antigeeniosoitus- ja PCR-menetelmillä keuhkokuumeen etiologia voidaan saada selvitettyä nopeasti. Lisäksi näitä menetelmiä käyttämällä taudin aiheuttajamikrobi löytyi huomattavasti suuremmalta osalta potilaista kuin pelkästään tavanomaisia menetelmiä käyttämällä. Pikamenetelmien hyödyllisyys vaihteli taudin vaikeusasteen mukaan. Respiratorinen virus löytyi huomattavan usein keuhkokuumetta sairastavilta potilailta, ja näiden potilaiden taudinkuva oli usein vaikea. Tulovaiheen korkeaa CRP-tasoa voidaan käyttää lisäkeinona arvioitaessa keuhkokuumeen vaikeutta. CRP on erityisen hyödyllinen arvioitaessa hoitovastetta ja riskiä komplikaatioiden ke¬hittymiseen. Neutrofiilien komplementtireseptorin ekspression tutkiminen näyttää lupaavalta pi¬kamenetelmältä erottamaan bakteerien ja virusten aiheuttamat taudit toisistaan. Antimikrobihoitoa saavilla potilailla BAL-tutkimuksen löydökset olivat vähäiset ja vaikuttivat hoitoon vain harvoin.
Resumo:
Urinalysis of acetone is important to monitor workers occupationally exposed to acetone and/or isopropanol, as well as in diagnosis of some diseases related to lipid metabolism impairment. This work shows a sensitive, simple and rapid static headspace-gas chromatographic procedure for quantitative determination of acetone in urine. The method was applied to measure acetone in 207 samples from general population volunteers, resulting in a mean level of 1.12 mg/L (± 0.47) and a range of 0.20 - 1.95 mg/L. The method is reproducible and reliable, making it suitable for routine analysis of acetone in urine.
Resumo:
This work reports the validation of an analytical UV spectrophotometric method to assay dexamethasone in tablets (assay and dissolution studies). The method was linear in the range between 1 and 30 µg mL-1 presenting a good correlation coefficient (r = 0.9998, n = 7). Precision and accuracy analysis showed low relative standard deviation (< 2.00%) and good percentual recoveries (95-105%). The procedure was linear, accurate, precise, and robust. The method is simple, and it has low cost. It does not use polluting reagents and can be applied in dissolution studies, being an adequate alternative to assay dexamethasone in tablets.
Resumo:
A new method is described for the determination of the herbicide bispyribac-sodium in surface water, especially from river and irrigated rice water samples. The method involves extraction in solid phase and quantification by high performance liquid chromatography with diode array detection (HPLC-DAD). After optimization of the extraction and separation parameters, the method was validated. The method presented average recoveries of 101.3 and 97.7%, under repeatability and intermediate precision conditions, respectively, with adequate precision (RSD from 0.9 to 7.5%). The method was applied for the determination of bispyribac-sodium in surface water samples with a limit of detection of 0.1 μg L-1.
Resumo:
A rapid, economical, reproducible, and simple direct spectrophotometric method was developed and validated for the assay of nitazoxanide in pharmaceutical formulations. Nitazoxanide concentration was estimated in water at 345 nm and pH 4.5. The method was suitable and validated for specificity, linearity, precision, and accuracy. There was no interference of the excipients in the determination of the active pharmaceutical ingredient. The proposed method was successfully applied in the determination of nitazoxanide in coated tablets and in powders for oral suspension. This method was compared to a previously developed and validated method for liquid chromatography to the same drug. There was no significative difference between these methods for nitazoxanide quantitation.
Resumo:
A method for the determination of trace amounts of palladium was developed using homogeneous liquid-liquid microextraction via flotation assistance (HLLME-FA) followed by graphite furnace atomic absorption spectrometry (GFAAS). Ammonium pyrrolidine dithiocarbamate (APDC) was used as a complexing agent. This was applied to determine palladium in three types of water samples. In this study, a special extraction cell was designed to facilitate collection of the low-density solvent extraction. No centrifugation was required in this procedure. The water sample solution was added to the extraction cell which contained an appropriate mixture of extraction and homogeneous solvents. By using air flotation, the organic solvent was collected at the conical part of the designed cell. Parameters affecting extraction efficiency were investigated and optimized. Under the optimum conditions, the calibration graph was linear in the range of 1.0-200 µg L-1 with a limit of detection of 0.3 µg L-1. The performance of the method was evaluated for the extraction and determination of palladium in water samples and satisfactory results were obtained. In order to verify the accuracy of the approach, the standard addition method was applied for the determination of palladium in spiked synthetic samples and satisfactory results were obtained.