996 resultados para Radiation Hybrid Panel


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Biotecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hemorrhagic gastritis is a possible late toxicity outcome after radical radiotherapy but it is nowadays a very rare condition and most likely depends on other clinical factors. We report the case of a 77-year-old woman with a symptomatic solitary extramedullary intra-abdominal plasmacytoma and multiple gastric comorbidities, treated with external beam radiotherapy. Despite the good response to radiotherapy, the patient experienced multiple gastric bleeding a few months later, with the need of multiple treatments for its control. In this paper we will discuss in detail all aspects related to the different causes of hemorrhagic gastritis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Hypoplastic left heart syndrome (HLHS) is a major cause of cardiac death during the first week of life. The hybrid approach is a reliable, reproducible treatment option for patients with HLHS. Herein we report our results using this approach, focusing on its efficacy, safety and late outcome. METHODS: We reviewed prospectively collected data on patients treated for HLHS using a hybrid approach between July 2007 and September 2014. RESULTS: Nine patients had a stage 1 hybrid procedure, with seven undergoing a comprehensive stage 2 procedure. One patient completed the Fontan procedure. Five patients underwent balloon atrial septostomy after the hybrid procedure; in three patients, a stent was placed across the atrial septum. There were three deaths: two early after the hybrid procedure and one early after stage two palliation. Overall survival was 66%. CONCLUSIONS: In our single-center series, the hybrid approach for HLHS yields intermediate results comparable to those of the Norwood strategy. The existence of dedicated teams for the diagnosis and management of these patients, preferably in high-volume centers, is of major importance in this condition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Present report demonstrates that repeated radiation of Schistosoma mansoni-infected Biomphalaria glabrata, totaling 15,000 rads, caused a sudden, albeit transient, suppression of cercarial shedding. Initially, sporocysts practically disappeared from the snail tissues. The more resistant developing cercariae presented nuclear clumping and vacuolation, before undergoing lysis. No host tissue reaction was evident at any time. Thirty-four days after the last irradiation, the snails resumed cercarial elimination. By that time numerous sporocysts and developing cercariae were detected, disseminated throughout snail tissues in a pattern similar to that of a highly malignant neoplasm, with no signs of host cellular reactions, which on the other hand were present in non-irradiated infected controls. The region of the ovo-testis was apparently destroyed after radiation, but returned to its normal appearance around 40 days after the last radiation. Ionizing radiation affected both host and parasite in S. mansoni-infected Biomphalaria glabrata, but the resulting impressive changes were soon reversed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Ambiente

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This dissertation presents an approach aimed at three-dimensional perception’s obstacle detection on all-terrain robots. Given the huge amount of acquired information, the adversities such environments present to an autonomous system and the swiftness, thus required, from each of its navigation decisions, it becomes imperative that the 3-D perceptional system to be able to map obstacles and passageways in the most swift and detailed manner. In this document, a hybrid approach is presented bringing the best of several methods together, combining the lightness of lesser meticulous analyses with the detail brought by more thorough ones. Realizing the former, a terrain’s slope mapping system upon a low resolute volumetric representation of the surrounding occupancy. For the latter’s detailed evaluation, two novel metrics were conceived to discriminate the little depth discrepancies found in between range scanner’s beam distance measurements. The hybrid solution resulting from the conjunction of these two representations provides a reliable answer to traversability mapping and a robust discrimination of penetrable vegetation from that constituting real obstructions. Two distinct robotic platforms offered the possibility to test the hybrid approach on very different applications: a boat, under an European project, the ECHORD Riverwatch, and a terrestrial four-wheeled robot for a national project, the Introsys Robot.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hybrid knowledge bases are knowledge bases that combine ontologies with non-monotonic rules, allowing to join the best of both open world ontologies and close world rules. Ontologies shape a good mechanism to share knowledge on theWeb that can be understood by both humans and machines, on the other hand rules can be used, e.g., to encode legal laws or to do a mapping between sources of information. Taking into account the dynamics present today on the Web, it is important for these hybrid knowledge bases to capture all these dynamics and thus adapt themselves. To achieve that, it is necessary to create mechanisms capable of monitoring the information flow present on theWeb. Up to today, there are no such mechanisms that allow for monitoring events and performing modifications of hybrid knowledge bases autonomously. The goal of this thesis is then to create a system that combine these hybrid knowledge bases with reactive rules, aiming to monitor events and perform actions over a knowledge base. To achieve this goal, a reactive system for the SemanticWeb is be developed in a logic-programming based approach accompanied with a language for heterogeneous rule base evolution having as its basis RIF Production Rule Dialect, which is a standard for exchanging rules over theWeb.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: O cancro de mama e o mais frequente diagnoticado a indiv duos do sexo feminino. O conhecimento cientifico e a tecnologia tem permitido a cria ção de muitas e diferentes estrat egias para tratar esta patologia. A Radioterapia (RT) est a entre as diretrizes atuais para a maioria dos tratamentos de cancro de mama. No entanto, a radia ção e como uma arma de dois canos: apesar de tratar, pode ser indutora de neoplasias secund arias. A mama contralateral (CLB) e um orgão susceptivel de absorver doses com o tratamento da outra mama, potenciando o risco de desenvolver um tumor secund ario. Nos departamentos de radioterapia tem sido implementadas novas tecnicas relacionadas com a radia ção, com complexas estrat egias de administra ção da dose e resultados promissores. No entanto, algumas questões precisam de ser devidamente colocadas, tais como: E seguro avançar para tecnicas complexas para obter melhores indices de conformidade nos volumes alvo, em radioterapia de mama? O que acontece aos volumes alvo e aos tecidos saudaveis adjacentes? Quão exata e a administração de dose? Quais são as limitações e vantagens das técnicas e algoritmos atualmente usados? A resposta a estas questões e conseguida recorrendo a m etodos de Monte Carlo para modelar com precisão os diferentes componentes do equipamento produtor de radia ção(alvos, ltros, colimadores, etc), a m de obter uma descri cão apropriada dos campos de radia cão usados, bem como uma representa ção geometrica detalhada e a composição dos materiais que constituem os orgãos e os tecidos envolvidos. Este trabalho visa investigar o impacto de tratar cancro de mama esquerda usando diferentes tecnicas de radioterapia f-IMRT (intensidade modulada por planeamento direto), IMRT por planeamento inverso (IMRT2, usando 2 feixes; IMRT5, com 5 feixes) e DCART (arco conformacional dinamico) e os seus impactos em irradia ção da mama e na irradia ção indesejada dos tecidos saud aveis adjacentes. Dois algoritmos do sistema de planeamento iPlan da BrainLAB foram usados: Pencil Beam Convolution (PBC) e Monte Carlo comercial iMC. Foi ainda usado um modelo de Monte Carlo criado para o acelerador usado (Trilogy da VARIAN Medical Systems), no c odigo EGSnrc MC, para determinar as doses depositadas na mama contralateral. Para atingir este objetivo foi necess ario modelar o novo colimador multi-laminas High- De nition que nunca antes havia sido simulado. O modelo desenvolvido est a agora disponí vel no pacote do c odigo EGSnrc MC do National Research Council Canada (NRC). O acelerador simulado foi validado com medidas realizadas em agua e posteriormente com c alculos realizados no sistema de planeamento (TPS).As distribui ções de dose no volume alvo (PTV) e a dose nos orgãos de risco (OAR) foram comparadas atrav es da an alise de histogramas de dose-volume; an alise estati stica complementar foi realizadas usando o software IBM SPSS v20. Para o algoritmo PBC, todas as tecnicas proporcionaram uma cobertura adequada do PTV. No entanto, foram encontradas diferen cas estatisticamente significativas entre as t ecnicas, no PTV, nos OAR e ainda no padrão da distribui ção de dose pelos tecidos sãos. IMRT5 e DCART contribuem para maior dispersão de doses baixas pelos tecidos normais, mama direita, pulmão direito, cora cão e at e pelo pulmão esquerdo, quando comparados com as tecnicas tangenciais (f-IMRT e IMRT2). No entanto, os planos de IMRT5 melhoram a distribuição de dose no PTV apresentando melhor conformidade e homogeneidade no volume alvo e percentagens de dose mais baixas nos orgãos do mesmo lado. A t ecnica de DCART não apresenta vantagens comparativamente com as restantes t ecnicas investigadas. Foram tamb em identi cadas diferen cas entre os algoritmos de c alculos: em geral, o PBC estimou doses mais elevadas para o PTV, pulmão esquerdo e cora ção, do que os algoritmos de MC. Os algoritmos de MC, entre si, apresentaram resultados semelhantes (com dferen cas at e 2%). Considera-se que o PBC não e preciso na determina ção de dose em meios homog eneos e na região de build-up. Nesse sentido, atualmente na cl nica, a equipa da F sica realiza medi ções para adquirir dados para outro algoritmo de c alculo. Apesar de melhor homogeneidade e conformidade no PTV considera-se que h a um aumento de risco de cancro na mama contralateral quando se utilizam t ecnicas não-tangenciais. Os resultados globais dos estudos apresentados confirmam o excelente poder de previsão com precisão na determinação e c alculo das distribui ções de dose nos orgãos e tecidos das tecnicas de simulação de Monte Carlo usados.---------ABSTRACT:Breast cancer is the most frequent in women. Scienti c knowledge and technology have created many and di erent strategies to treat this pathology. Radiotherapy (RT) is in the actual standard guidelines for most of breast cancer treatments. However, radiation is a two-sword weapon: although it may heal cancer, it may also induce secondary cancer. The contralateral breast (CLB) is a susceptible organ to absorb doses with the treatment of the other breast, being at signi cant risk to develop a secondary tumor. New radiation related techniques, with more complex delivery strategies and promising results are being implemented and used in radiotherapy departments. However some questions have to be properly addressed, such as: Is it safe to move to complex techniques to achieve better conformation in the target volumes, in breast radiotherapy? What happens to the target volumes and surrounding healthy tissues? How accurate is dose delivery? What are the shortcomings and limitations of currently used treatment planning systems (TPS)? The answers to these questions largely rely in the use of Monte Carlo (MC) simulations using state-of-the-art computer programs to accurately model the di erent components of the equipment (target, lters, collimators, etc.) and obtain an adequate description of the radiation elds used, as well as the detailed geometric representation and material composition of organs and tissues. This work aims at investigating the impact of treating left breast cancer using di erent radiation therapy (RT) techniques f-IMRT (forwardly-planned intensity-modulated), inversely-planned IMRT (IMRT2, using 2 beams; IMRT5, using 5 beams) and dynamic conformal arc (DCART) RT and their e ects on the whole-breast irradiation and in the undesirable irradiation of the surrounding healthy tissues. Two algorithms of iPlan BrainLAB TPS were used: Pencil Beam Convolution (PBC)and commercial Monte Carlo (iMC). Furthermore, an accurate Monte Carlo (MC) model of the linear accelerator used (a Trilogy R VARIANR) was done with the EGSnrc MC code, to accurately determine the doses that reach the CLB. For this purpose it was necessary to model the new High De nition multileaf collimator that had never before been simulated. The model developed was then included on the EGSnrc MC package of National Research Council Canada (NRC). The linac was benchmarked with water measurements and later on validated against the TPS calculations. The dose distributions in the planning target volume (PTV) and the dose to the organs at risk (OAR) were compared analyzing dose-volume histograms; further statistical analysis was performed using IBM SPSS v20 software. For PBC, all the techniques provided adequate coverage of the PTV. However, statistically significant dose di erences were observed between the techniques, in the PTV, OAR and also in the pattern of dose distribution spreading into normal tissues. IMRT5 and DCART spread low doses into greater volumes of normal tissue, right breast, right lung, heart and even the left lung than tangential techniques (f-IMRT and IMRT2). However,IMRT5 plans improved distributions for the PTV, exhibiting better conformity and homogeneity in target and reduced high dose percentages in ipsilateral OAR. DCART did not present advantages over any of the techniques investigated. Di erences were also found comparing the calculation algorithms: PBC estimated higher doses for the PTV, ipsilateral lung and heart than the MC algorithms predicted. The MC algorithms presented similar results (within 2% di erences). The PBC algorithm was considered not accurate in determining the dose in heterogeneous media and in build-up regions. Therefore, a major e ort is being done at the clinic to acquire data to move from PBC to another calculation algorithm. Despite better PTV homogeneity and conformity there is an increased risk of CLB cancer development, when using non-tangential techniques. The overall results of the studies performed con rm the outstanding predictive power and accuracy in the assessment and calculation of dose distributions in organs and tissues rendered possible by the utilization and implementation of MC simulation techniques in RT TPS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper demonstrates the significance of culture in examining the relationshipbetween democratic capital and environmental performance.The aim is to examine the relationship among scores on the Environmental Performance Index and the two dimensions of cross cultural variation suggested by Ronald Inglehart and Christian Welzel. Significantional interrelationships among democracy, cultural and environmental sustaintability measures could be found, following the regression results. Firstly, higher levels of democratic capital stock are associated with better environmental performance. Secondly importance to distinguish between cultural groups could be confirmed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction This study evaluated the level of concordance between hybrid capture II (HCII) and PapilloCheck® for the detection of high-risk human papillomavirus (HPV) in anal samples. Methods Anal cell samples collected from 42 human immunodeficiency virus (HIV)+ patients were analyzed. Results Considering only the 13 high-risk HPV types that are detectable by both tests, HCII was positive for 52.3% of the samples, and PapilloCheck® was positive for 52.3%. The level of concordance was 80.9% (Kappa = 0.61). Conclusions Good concordance was observed between the tests for the detection of high-risk HPV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presente tese reflete sobre os temas do desenvolvimento sustentável, da sustentabilidade corporativa, da responsabilidade social corporativa e das dimensões do Triple Bottom Line. O principal objetivo do nosso trabalho é contribuir para o conhecimento das relações que se estabelecem nas interseções entre a dimensão económica, social e ambiental da sustentabilidade corporativa, aqui designadas de relações híbridas. Neste sentido, desenvolveu-se um enquadramento teórico que fundamenta o modelo proposto, designado por Hybrid Bottom Line. De acordo com este enquadramento procurou-se conceber uma metodologia que permitisse analisar como é que estas relações de interseção entre economia-ambiente e economia-social se verificam e de que forma os seus resultados podem beneficiar a compreensão, avaliação e melhorias no entendimento da sustentabilidade corporativa, bem como possibilitar uma análise dirigida a fatores recombinantes específicos. Em complemento, foi desenvolvida uma proposta que permite posicionar o esforço desenvolvido pela empresa no âmbito da sustentabilidade e desta forma tipificar as suas ações. Nesta tese a abordagem empírica recaiu na análise dos relatórios de sustentabilidade publicados pelas empresas e baseados nas diretivas de relato propostas pelo Global Reporting Initiative. A amostra para o estudo abrangeu um total de 85 empresas de diferentes dimensões de 36 sectores económicos e representando 36 países de 5 continentes. A análise dos resultados foi feita utilizando diversos métodos de análise de dados (de frequência e de conteúdo) e análises estatísticas (análise de contingência, variância e de correspondências múltiplas) que permitiram observar as relações entre as dimensões do Triple Bottom Line, dando lugar à construção de uma matriz de relações híbridas. Seguidamente foi realizada uma análise longitudinal de uma das empresas da amostra tendo como referência a matriz híbrida obtida, assim como a tipificação da empresa no âmbito da sustentabilidade. Os resultados alcançados nas diferentes fases indicam que o enquadramento teórico que foi utilizado é útil para a análise das interseções entre as dimensões e permite uma avaliação dirigida a fatos ocorridos entre pares dimensionais, bem como projetar análises e posicionamentos futuros. Os resultados obtidos sugerem que a proposta apresentada é útil e deverá ser utilizada e desenvolvida noutros contextos. Esta tese contribui para a ideia de que a responsabilidade corporativa não deve ser só vista e operacionalizada como uma realidade de dimensões segmentadas mas também deve ser observada como um conjunto possível de interações que se manifestam nas interseções das suas diferentes dimensões.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis was investigated the radiation hardness of the building blocks of a future flexible X-ray sensor system. The characterized building blocks for the pixel addressing and signal amplification electronics are high mobility semiconducting oxide transistors (HMSO-TFTs) and organic transistors (OTFTs), whereas the photonic detection system is based on organic semiconducting single crystals (OSSCs). TFT parameters such as mobility, threshold voltage and subthreshold slope were measured as function of cumulative X-ray dose. Instead for OSSCs conductivity and X-ray sensitivity were analysed after various radiation steps. The results show that ionizing radiation does not lead to degradation in HMSO-TFTs. Instead OTFTs show instability in mobility which is reduced up to 73% for doses of 1 kGy. OSSC demonstrate stable detector properties for the tested total dose range. As conclusion, HMSO-TFTs and OSSCs can be readily employed in the X-ray detector system allowing operation for total doses exceeding 1 kGy of ionizing radiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rare case of thumb metastasis from small cell lung cancer is presented. The patient underwent local radiotherapy with complete palliation of symptoms. She died 4 months later with disseminated disease. Considerations about incidence, treatment, and physiopathology of this kind of dissemination are made. Conservative treatment of finger metastasis with radiation may be considered due to the poor outcome of these patients.