585 resultados para Preplanting refrigeration
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This work presents a numerical model to simulate refrigerant flow through capillary tubes, commonly used as expansion devices in refrigeration systems. The flow is divided in a single-phase region, where the refrigerant is in the subcooled liquid state, and a region of two-phase flow. The capillary tube is considered straight and horizontal. The flow is taken as one-dimensional and adiabatic. Steady-state condition is also assumed and the metastable flow phenomena are neglected. The two-fluid model, considering the hydrodynamic and thermal non-equilibrium between the liquid and vapor phases, is applied to the two-phase flow region. Comparisons are made with experimental measurements of the mass flow rate and pressure distribution along two capillary tubes working with refrigerant R-134a in different operating conditions. The results indicate that the present model provides a better estimation than the commonly employed homogeneous model. Some computational results referring to the quality, void fraction, velocities, and temperatures of each phase are presented and discussed.
Resumo:
Pós-graduação em Biotecnologia Animal - FMVZ
Resumo:
Pós-graduação em Agronomia (Produção Vegetal) - FCAV
Resumo:
Pós-graduação em Agronomia (Produção Vegetal) - FCAV
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study aimed to determine the antioxidant activity, total phenolic compounds and color in avocado 'Hass' hydrothermally treated. The fruits were hydrothermally treated at 45 degrees C for 5, 10, 15 and 20 min. After treatment, fruit were stored at room temperature (21 +/- 1 degrees C and 70 +/- 5% relative humidity) and cold (10 degrees C +/- 1 and 90 +/- 5% relative humidity). The fruits were analyzed for their antioxidant capacity by DPPH method and phenolic compounds at 0, 3, 9 and 12 days. The fruits color was measured at 0, 3, 6, 9, 12 and 15 days. The control fruits had higher antioxidant capacity and content of phenolic compounds during the storage period, compared to the fruits hydrothermally treated. The hydrothermally treatment altered the behavior as for the maintenance of the antioxidant activity in relation to the fruits control. In spite of superior values of antioxidant activity for the fruits maintained at 21 +/- 1 degrees C and 70 +/- 5% relative humidity, those refrigerated presented better aspect for commercialization. The refrigerated fruits presented better aspect for commercialization in relation to the maintained under room temperature. The brightness, color a * and b * values decreased with the storage days. Values color superiors were observed for the fruits control and those maintained under refrigeration. As it increased the irradiation dose reduced the fruits antioxidant activity and coloration.
Resumo:
The term refrigeration solar refers to any air conditioning system that uses solar energy as a primary energy source. The use of solar radiation for cooling purposes is divided according to their technological possibilities which are distinguished from one another as the way that energy is involved in the cycle, work or heat. The first case is related to vapor compression cycles, in which the work input is provided by the photovoltaic conversion of solar energy into electrical energy. In the second case, an absorption refrigeration cycle is used and the thermal energy collected from the solar radiation is provided at the generator of this cycle.. In this work a system with an absorption cycle using the pair BrLi-water, using solar energy as input is modeled. It is considered a simple refrigeration cycle whose the equations of mass and energy conservation in each component are developed in order to obtain an algebraic equation set and a simulation routine using the EES software. Although the simulation operates under certain specified thermal load it is possible to estimate the necessary areas of heat exchangers and solar collectors
Resumo:
Human development and population growth during the twentieth century increased the water demand, tripling its consumption between 1950 and 1990. As the water streams were polluted; and as water is the source of minerals and also regulates vital functions, it becomes the vehicle of transmission and consequently spreads many diseases. Probably, the industries are the major responsible for this pollution when they dump untreated effluents to water streams, saturating the already insufficient net of sanitation facilities polluting water and soil. An effective treatment has been established with low cost in Europe and the United States, through constructed systems on wetlands Constructed Wetland Systems - CWSs, gradually used in other countries in the last three decades. Lately, we observe a continuous growth in Brazilian poultry business, and poultry industry showed greatest dynamism in the country, following the global market. Pondering this information and the efficiency of such treatment, this work aimed to study prototypes, in a laboratory scale, simulating ascending and descending types of CWSs, vegetated with aquatic macrophytes Eichhornia crassipes and the uses of aggregates and soil, to treat industrial wastewater from slaughterhouses and aviary. We conducted the initial characterization of the effluent to have an idea of its constituents and to scale the system and the continuous flow. Furthermore, we characterized the soil to be used in this system. The collects are periodically made in the refrigeration industry FRICOCK FRIGORIFICAÇÃO AVICULTURA INDÚSTRIA E COMÉRCIO LTDA. for local treatment simulation. The effluent that was treated with 12 prototypes of CWSs are analyzed with some frequency. The results of these reviews were compared to the effluent coming from the industry... (Complete abstract click electronic access below)
Resumo:
The discussions about the energy rationalization are gaining more and more space on the everyday of engineers and other professionals in the field of energy. A greater focus is being tied to commercial buildings, because they are one of the biggest responsible for the high energetic expenditure according to the National Energetic Balance, especially by the use of air conditioners for the people’s thermal comfort. Such finding made INMETRO to develop a building labeling procedure through th National Program of Electric Energy Conservation in Buildings; by means of this systematic, the built areas are classified by levels that go from A(the best) to E(the worst), taking into account envelopment, illumination system and air conditioning. A bonus process based on water rationalization, use of renewable energy sources, cogeneration systems or technical innovations, allows the classification to be changed up to one level. A study made exactly on a commercial building, the building of Foundation for Technological and Scientific Development located inside of the College of Engineering of Guaratinguetá, sought to identify technical/economic alternatives for the building certification and appealed to the bonus based on water rationalization. The present study is based on analysis of deploying a cogeneration system formed by internal combustion engine and an absorption refrigeration system as bonus alternative, so that the costs are analyzed regarding energy consumption and use of the motor. With the calculations and results, the viability of the building to receive a bonus from INMETRO through its National Program for Energy Conservation in Buildings is studied and concluded from this study whether or not you can get a better level of energy efficiency for the building in question... (Complete abstract click electronic access below)
Resumo:
The lubricant oil used in engines of internal combustion must be, periodically, changed. Its mainly function in the engines is to reduce the friction between the pieces, but its presence also promotes the cleanness and the refrigeration of the equipment. These attributions, at the end of some cycles of operation, make the oil to be dirty, that is, full of contaminating substances such as water, gasoline, diesel, additives, oxidized hydro-carbons and rests of metals, not being recommended, therefore, its discarding in the environment. Thus, all the used lubricant oil that leaves the automobiles engine has been thrust, waiting for a solution. The pollution generated by the discarding of a ton of used oil per day in the soil or in the rivers is equivalent to a domestic sewer of 40 thousand of people. The indiscriminate burning of the used lubricant oil generates significant emissions of metallic oxides, besides other toxic gases, like the dioxin and sulphur oxides. In this context, the mean objective of this essay was to effectuate the rerrefine of the used lubricant oil, aiming the increase of its life cycle and consequently contributing for the reduction of the environmental pollution. According to the used process, it was possible to get a rerrefine oil, of good quality, which physicistchemistries properties are in compliance with the norms of NBR and ASTM
Resumo:
This work presents a study of the absorption refrigeration system and the modeling and evaluation of two cycles using the binary solutions water-lithium bromide and ammonia-water for an equipment to be used in small size plants like residences. The study and evaluation aims the complete understanding of all parts of the system and the influence of each one of them as well as the spread of the knowledge to raise the use of this type of equipment in all sizes in order to decrease the energetic consumption of plants of all scales and making viable the alternative sources. The study is done in each element of the cycle separately and in some auxiliary equipments required in the operation such as the main power source, the solar collector. The software used for modeling, with emphasis on thermal part, was the EES (Engineering Equation Solver), that permitted the thermal balance calculus and acquisition of the used fluids properties. The results obtained for the equipment shows the system is more complex than the widely used in business, however, it can be viable and represents an alternative to increase the energetic efficiency