944 resultados para Plug-filling
Resumo:
Background: During the past 15 years, polymethylmethacrylate has been used as a synthetic permanent filler for soft-tissue augmentation. Methods: This. article reports 32 cases of complications seen at Hospital das Clinicas, Faculty of Medicine, University of Sao Paulo, for procedures performed elsewhere. Results: The average age of the patients was 43.6 years (range, 22 to 70 years). Twenty-five patients were women. Sixteen injection procedures were performed by certified plastic surgeons, nine by dermatologists, two by urologists, and one by a nonphysician. Complications were classified into five groups according to main presentation as follows: tissue necrosis (five cases), an acute complication that can be related to technical mistakes but that can also be dependent on patient factors or caused by local infection; granuloma (10 cases), which usually presents as a subacute complication 6 to 12 months after the procedure; chronic inflammatory reactions (10 cases), which usually occur years later and can be related to a triggering event, Such as another operation or infection in the area that was injected (these reactions are immunogenic in origin and may have cyclic periods of activation and remission); chronic inflammatory reaction in the lips (six cases), which may be present with severe symptoms, especially with lymphedema, because of mobility of the lip; and infections (one case), which are rare but possible complications after filling procedures. Conclusions: Polymethylmethacrylate filler complications, despite being rare, are often permanent and difficult or even impossible to treat. Safety guidelines should be observed when considering use of polymethylmethacrylate for augmentation.
Resumo:
BACKGROUND: The arterial pulse pressure variation induced by mechanical ventilation (Delta PP) has been shown to be a predictor of fluid responsiveness. Until now, Delta PP has had to be calculated offline (from a computer recording or a paper printing of the arterial pressure curve), or to be derived from specific cardiac output monitors, limiting the widespread use of this parameter. Recently, a method has been developed for the automatic calculation and real-time monitoring of Delta PP using standard bedside monitors. Whether this method is to predict reliable predictor of fluid responsiveness remains to be determined. METHODS: We conducted a prospective clinical study in 59 mechanically ventilated patients in the postoperative period of cardiac surgery. Patients studied were considered at low risk for complications related to fluid administration (pulmonary artery occlusion pressure <20 mm Hg, left ventricular ejection fraction >= 40%). All patients were instrumented with an arterial line and a pulmonary artery catheter. Cardiac filling pressures and cardiac output were measured before and after intravascular fluid administration (20 mL/kg of lactated Ringer`s solution over 20 min), whereas Delta PP was automatically calculated and continuously monitored. RESULTS: Fluid administration increased cardiac output by at least 15% in 39 patients (66% = responders). Before fluid administration, responders and nonresponders were comparable with regard to right atrial and pulmonary artery occlusion pressures. In contrast, Delta PP was significantly greater in responders than in nonresponders, (17% +/- 3% vs 9% +/- 2%, P < 0.001). The Delta PP cut-off value of 12% allowed identification of responders with a sensitivity of 97% and a specificity of 95%. CONCLUSION: Automatic real-time monitoring of Delta PP is possible using a standard bedside rnonitor and was found to be a reliable method to predict fluid responsiveness after cardiac surgery. Additional studies are needed to determine if this technique can be used to avoid the complications of fluid administration in high-risk patients.
Resumo:
Aims: To report the conclusion of the Think Thank 8 on Compliance Discussions during the second ICI-RS meeting in 2010. Methods: During a 3-day meeting a group of specialists discussed bladder compliance, what it represents, how it can be measured and if it is clinically relevant. Results: Bladder compliance is the result of a mathematical calculation of the volume required for a unit rise of pressure measured during a cystometric filling. It gives an indication on how the different mechanisms in the bladder wall react on stretching. There is a need of standardization of measurement and suggestions for this are given in the text. Pitfalls are described and how to avoid them. There is a wide range of compliance values in healthy volunteers and groups of patients. Poor compliance needs to be defined better as it can have significant clinical consequences. Prevention and treatment are discussed. Conclusion: If compliance is correctly measured and interpreted, it has importance in urodynamic testing and gives information relevant for clinical management. Neurourol. Urodynam. 30:714-722, 2011. (C) 2011 Wiley-Liss, Inc.
Resumo:
Bliacheriene F, Carmona MJC, Barretti CFM, Haddad CMF, Mouchalwat ES, Bortlotto MRFL, Francisco RPV, Zugaib M - Use of a Minimally Invasive Uncalibrated Cardiac Output Monitor in Patients Undergoing Cesarean Section under Spinal Anesthesia: Report of Four Cases. Background and Objectives: Hemodynamic changes are observed during cesarean section under spinal anesthesia. Non-invasive blood pressure (BP) and heart rate (HR) measurements are performed to diagnose these changes, but they are delayed and inaccurate. Other monitors such as filling pressure and cardiac output (CO) catheters with external calibration are very invasive or inaccurate. The objective of the present study was to report the cardiac output measurements obtained with a minimally invasive uncalibrated monitor (LiDCO rapid) in patients undergoing cesarean section under spinal anesthesia. Case report: After approval by the Ethics Commission, four patients agreed to participate in this study. They underwent cesarean section under spinal anesthesia while at the same time being connected to the LiDCO rapid by a radial artery line. Cardiac output, HR, and BP were recorded at baseline, after spinal anesthesia, after fetal and placental extraction, and after the infusion of oxytocin and metaraminol. We observed a fall in BP with an increase of HR and CO after spinal anesthesia and oxytocin infusion; and an increase in BP with a fall in HR and CO after bolus of the vasopressor. Conclusions: Although this monitor had not been calibrated, it showed a tendency for consistent hemodynamic data in obstetric patients and it may be used as a therapeutic guide or experimental tool.
Resumo:
Background: Different hemodynamic parameters including static indicators of cardiac preload as right ventricular end-diastolic volume index (RVEDVI) and dynamic parameters as pulse pressure variation (PPV) have been used in the decision-making process regarding volume expansion in critically ill patients. The objective of this study was to compare fluid resuscitation guided by either PPV or RVEDVI after experimentally induced hemorrhagic shock. Methods: Twenty-six anesthetized and mechanically ventilated pigs were allocated into control (group I), PPV (group II), or RVEDVI (group III) group. Hemorrhagic shock was induced by blood withdrawal to target mean arterial pressure of 40 mm Hg, maintained for 60 minutes. Parameters were measured at baseline, time of shock, 60 minutes after shock, immediately after resuscitation with hydroxyethyl starch 6% (130/0.4), 1 hour and 2 hours thereafter. The endpoint of fluid resuscitation was determined as the baseline values of PPV and RVEDVI. Statistical analysis of data was based on analysis of variance for repeated measures followed by the Bonferroni test (p < 0.05). Results: Volume and time to resuscitation were higher in group III than in group II (group III = 1,305 +/- 331 mL and group II = 965 +/- 245 mL, p < 0.05; and group III = 24.8 +/- 4.7 minutes and group II = 8.8 +/- 1.3 minutes, p < 0.05, respectively). All static and dynamic parameters and biomarkers of tissue oxygenation were affected by hemorrhagic shock and nearly all parameters were restored after resuscitation in both groups. Conclusion: In the proposed model of hemorrhagic shock, resuscitation to the established endpoints was achieved within a smaller amount of time and with less volume when guided by PPV than when guided by pulmonary artery catheter-derived RVEDVI.
Resumo:
A simple framework was used to analyse the determinants of potential yield of sunflower (Helianthus annuus L.) in a subtropical environment. The aim was to investigate the stability of the determinants crop duration, canopy light interception, radiation use efficiency (RUE), and harvest index (HI) at 2 sowing times and with 3 genotypes differing in crop maturity and stature. Crop growth, phenology, light interception, yield, prevailing temperature, and radiation were recorded and measured throughout the crop cycle. Significant differences in grain yield were found between the 2 sowings, but not among genotypes within each sowing. Mean yields (0% moisture) were 6 . 02 and 2 . 17 t/ha for the first sowing, on 13 September (S1), and the second sowing, on 5 March (S2), respectively. Exceptionally high yields in S1 were due to high biomass assimilation associated with the high radiation environment, high light interception owing to a greater leaf area index, and high RUE (1 . 47-1 . 62 g/MJ) across genotypes. It is proposed that the high RUE was caused by high levels of available nitrogen maintained during crop growth by frequent applications of fertiliser and sewage effluent as irrigation. In addition to differences in the radiation environment, the assimilate partitioned to grain was reduced in S2 associated with a reduction in the duration of grain-filling. Harvest index was 0 . 40 in S1 and 0 . 25 in S2. It is hypothesised that low minimum temperatures experienced in S2 reduced assimilate production and partitioning, causing premature maturation.
Resumo:
Magneto-transport measurements of the 2D hole system (2DHS) in p-type Si-Si1-xGex heterostructures identify the integer quantum Hall effect (IQHE) at dominantly odd-integer filling factors v and two low-temperature insulating phases (IPs) at v = 1.5 and v less than or similar to 0.5, with re-entrance to the quantum Hall effect at v = 1. The temperature dependence, current-voltage characteristics, and tilted field and illumination responses of the IP at v = 1.5 indicate that the important physics is associated with an energy degeneracy of adjacent Landau levels of opposite spin, which provides a basis for consideration of an intrinsic, many-body origin.
Resumo:
Current design procedures for Subsurface Flow (SSF) Wetlands are based on the simplifying assumptions of plug flow and first order decay of pollutants. These design procedures do yield functional wetlands but result in over-design and inadequate descriptions of the pollutant removal mechanisms which occur within them. Even though these deficiencies are often noted, few authors have attempted to improve modelling of either flow or pollutant removal in such systems. Consequently the Oxley Creek Wetland, a pilot scale SSF wetland designed to enable rigorous monitoring, has recently been constructed in Brisbane, Australia. Tracer studies have been carried out in order to determine the hydraulics of this wetland prior to commissioning it with sealed sewage. The tracer studies will continue during the wetland's commissioning and operational phases. These studies will improve our understanding of the hydraulics of newly built SSF wetlands and the changes brought on by operational factors such as biological films and wetland plant root structures. Results to date indicate that the flow through the gravel beds is not uniform and cannot be adequately modelled by a single parameter, plug flow with dispersion, model. We have developed a multiparameter model, incorporating four plug flow reactors, which provides a better approximation of our experimental data. With further development this model will allow improvements to current SSF wetland design procedures and operational strategies, and will underpin investigations into the pollutant removal mechanisms at the Oxley Creek Wetland. (C) 1997 IAWQ. Published by Elsevier Science Ltd.
Resumo:
Background: The relation between left ventricular filing velocities determined by Doppler echocardiography and autonomic nervous system function assessed by heart rate variability (HRV) is unclear. The aim of this study was to evaluate the influence of the autonomic nervous system assessed by the time and frequency domain indices of HRV in the Doppler indices of left ventricular diastolic filling velocities in patients without heart disease. Methods: We studied 451 healthy individuals (255 female [56.4%]) with normal blood pressure, electrocardiogram, chest x-ray, and treadmill electrocardiographic exercise stress test results, with a mean age of 43 +/- 12 (range 15-82) years, who underwent transthoracic Doppler echocardiography and 24-hour electrocardiographic ambulatory monitoring. We studied indices of HRV on time (standard deviation [SD] of all normal sinus RR intervals during 24 hours, SD of averaged normal sinus RR intervals for all 5-minute segments, mean of the SD of all normal sinus RR intervals for all 5-minute segments, root-mean-square of the successive normal sinus RR interval difference, and percentage of successive normal sinus RR intervals > 50 ms) and frequency (low frequency, high frequency, very low frequency, low frequency/high frequency ratio) domains relative to peak flow velocity during rapid passive filling phase (E), atrial contraction (A), E/A ratio, E-wave deceleration time, and isovolumic relaxation time. Statistical analysis was performed with Pearson correlation and logistic regression. Results: Peak flow velocity during rapid passive filling phase (E) and atrial contraction (A), E/A ratio, and deceleration time of early mitral inflow did not demonstrate a significant correlation with indices of HRV in time and frequency domain. We found that the E/A ratio was < 1 in 45 individuals (10%). Individuals with an E/A ratio < 1 had lower indices of HRV in frequency domain (except low frequency/high frequency) and lower indices of the mean of the SD of all normal sinus RR intervals for all 5-minute segments, root-mean-square of the successive normal sinus RR interval difference, and percentage of successive normal sinus RR intervals > 50 ms in time domain. Logistic regression demonstrated that an E/A ratio < 1 was associated with lower HF. Conclusion: Individuals with no evidence of heart disease and an E/A ratio < 1 demonstrated a significant decrease in indexes of HRV associated with parasympathetic modulation. (J Am Soc Echocardiogr 2010;23: 762-5.)
Resumo:
Spinal involvement is a common presentation of multiple myeloma (MM); however, the cervical spine is the least common site of myelomatous involvement. Few studies evaluate the results of percutaneous vertebroplasty (PV) in the treatment of MM of the spine. The purpose of this series is to report on the use of PV in the treatment of MM of the cervical spine and to review the literature. From January 1994 to October 2007, four patients (three men and one woman; mean age, 45 years) who underwent five PV for painful MM in the cervical spine were retrospectively reviewed. The pain was estimated by the patient on a verbal analogic scale. Clinical follow-up was available for all patients (mean, 27.5 months; range, 1-96 months). The mean volume of cement injected per vertebral body was 2.3 +/- 0.8 mL (range, 1.0-4.0 mL) with a mean vertebral filling of 55.0 +/- 12.0% (range, 40.0-75.0%). Analgesic efficacy was achieved in all patients. One patient had a spinal instability due to a progression of spinal deformity noted on follow-up radiographs, without clinical symptoms. Cement leakage was detected in three (60%) of the five treated vertebrae. There was no clinical complication. The present series suggests that PV for MM of the cervical spine is safe and effective for pain control; nonetheless, the detrimental impact of the disease on bone quality should prompt close radiological follow-up after PV owing to the risk of spinal instability.
Resumo:
Background and objective The influence of ventilatory settings on static and functional haemodynamic parameters during mechanical ventilation is not completely known. The purpose of this study was to evaluate the effect of positive end-expiratory pressure, tidal volume and inspiratory to expiratory time ratio variations on haemodynamic parameters during haemorrhage and after transfusion of shed blood. Methods Ten anaesthetized pigs were instrumented and mechanically ventilated with a tidal volume of 8 ml kg(-1), a positive end-expiratory pressure of 5 cmH(2)O and an inspiratory to expiratory ratio of 1 : 2. Then, they were submitted in a random order to different ventilatory settings (tidal volume 16 ml kg(-1), positive end-expiratory pressure 15 cmH(2)O or inspiratory to expiratory time ratio 2: 1). Functional and static haemodynamic parameters (central venous pressure, pulmonary artery occlusion pressure, right ventricular end-diastolic volume and pulse pressure variation) were evaluated at baseline, during hypovolaemia (withdrawal of 20% of estimated blood volume) and after an infusion of withdrawn blood (posttransfusion). Results During baseline, a positive end-expiratory pressure of 15cmH(2)O significantly increased pulmonary artery occlusion pressure from 14.6 +/- 1.6 mmHg to 17.4 +/- 1.7 mmHg (P<0.001) and pulse pressure variation from 15.8 +/- 8.5% to 25.3 +/- 9.5% (P<0.001). High tidal volume increased pulse pressure variation from 15.8 8.5% to 31.6 +/- 10.4% (P<0.001), and an inspiratory to expiratory time ratio of 2: 1 significantly increased only central venous pressure. During hypovolaemia, high positive end-expiratory pressure influenced all studied variables, and high tidal volume strongly increased pulse pressure variation (40.5 +/- 12.4% pre vs. 84.2 +/- 19.1 % post, P<0.001). The inversion of the inspiratory to expiratory time ratio only slightly increased filling pressures during hypovolaemia, without without affecting pulse pressure variation or right ventricle end-diastolic volume. Conclusion We concluded that pulse pressure variation measurement is influenced by cyclic variations in intrathoracic pressure, such as those caused by augmentations in tidal volume. The increase in mean airway pressure caused by positive end-expiratory pressure affects cardiac filling pressures and also pulse pressure variation, although to a lesser extent. Inversion of the inspiratory to expiratory time ratio does not induce significant changes in static and functional haemodynamic parameters. Eur J Anaesthesiol 26:66-72 (c) 2009 European Society of Anaesthesiology.
Resumo:
Background and objective: Dynamic indices represented by systolic pressure variation and pulse pressure variation have been demonstrated to be more accurate than filling pressures in predicting fluid responsiveness. However, the literature is scarce concerning the impact of different ventilatory modes on these indices. We hypothesized that systolic pressure variation or pulse pressure variation could be affected differently by volume-controlled ventilation and pressure-controlled ventilation in an experimental model, during normovolaemia and hypovolaemia. Method: Thirty-two anaesthetized rabbits were randomly allocated into four groups according to ventilatory modality and volaemic status where G1-ConPCV was the pressure-controlled ventilation control group, G2-HemPCV was associated with haemorrhage, G3-ConVCV was the volume-controlled ventilation control group and G4-HemVCV was associated with haemorrhage. In the haemorrhage groups, blood was removed in two stages: 15% of the estimated blood volume withdrawal at M1, and, 30 min later, an additional 15% at M2. Data were submitted to analysis of variance for repeated measures; a value of P < 0.05 was considered to be statistically significant. Results: At MO (baseline), no significant differences were observed among groups. At M1, dynamic parameters differed significantly among the control and hypovolaemic groups (P < 0.05) but not between ventilation modes. However, when 30% of the estimated blood volume was removed (M2), dynamic parameters became significantly higher in animals under volume-controlled ventilation when compared with those under pressure-controlled ventilation. Conclusions: Under normovolaemia and moderate haemorrhage, dynamic parameters were not influenced by either ventilatory modalities. However, in the second stage of haemorrhage (30%), animals in volume-controlled ventilation presented higher values of systolic pressure variation and pulse pressure variation when compared with those submitted to pressure-controlled ventilation.
Resumo:
OBJECTIVE: We studied the angiographic findings in patients with small epidural hematomas and cranial fractures crossing over the trajectory of the middle meningeal artery and its branches. Additionally, the Occurrence of traumatic vascular lesions and their clinical relevance and treatment are discussed. METHODS: A consecutive analysis was performed for 24 patients who harbored small epidural hematomas in middle meningeal artery topography associated with cranial fractures. Computed tomographic scans and plain x-ray studies were used to diagnose linear cranial fractures. Patients with large epidural hematomas or associated traumatic lesions were excluded from the study. Selective ipsilateral external carotid angiograms were obtained, and an endovascular procedure was performed if any vascular injury was evidenced. RESULTS: In all patients with cranial fractures crossing over the middle meningeal artery and its branches, some kind of vascular lesion was seen. Two types of findings were noted: active extravasation of the contrast medium (71%) and pseudoaneurysms (29%). Early filling of diploic vessels was found in 8.3% of fractures concomitantly with active extravasation. Embolization was performed in all patients. No additional enlargement of the epidural hematoma was observed, and the postoperative period was uneventful. CONCLUSION: This study shows that pseudoaneurysms and active extravasation of contrast are common findings in this subset of patients. Although the natural history of these lesions is still poorly understood, additional investigation with ipsilateral external carotid angiography may be recommended, considering the potentially catastrophic consequences of late rupture.
Resumo:
Background: Most cases of congenital clubfoot treated with the Ponseti technique require percutaneous Achilles tenotomy to correct the residual equinus. Clinical evidence suggests that complete healing occurs between the cut tendon stumps, but there have not yet been any detailed studies investigating this reparative process. This study was performed to assess Achilles tendon repair after percutaneous section to correct the residual equinus of clubfoot treated with the Ponseti method. Method: A prospective study analyzed 37 tenotomies in 26 patients with congenital clubfoot treated with the Ponseti technique, with a minimum follow-up of 1 year after the section. The tenotomy was performed percutaneously with a large-bore needle bevel with patient sedation and local anesthesia. Ultrasonographic scanning was performed after section to ascertain that the tenotomy had been completed and to measure the stump separation. In the follow-up period, the reparative process was followed ultrasonographically and assessed at 3 weeks, 6 months, and 1 year posttenotomy. Results: The ultrasonography performed immediately after the procedure showed that in some cases, residual strands between the tendon ends persisted, and these were completely sectioned under ultrasound control. A mean retraction of 5.65 mm +/- 2.26 mm (range, 2.3 to 11.0 mm) between tendon stumps after section was observed. Unusual bleeding occurred in one case and was controlled by digital pressure, with no interference with the final treatment. After 3 weeks, ultrasonography showed tendon repair with the tendon gap filled with irregular hypoechoic tissue, and also with transmission of muscle motion to the heel. Six months after tenotomy, there was structural filling with a fibrillar aspect, mild or moderate hypoechogenicity, and tendon scar thickening when compared with a normal tendon. One year after tenotomy, ultrasound showed a fibrillar structure and echogenicity at the repair site that was similar to a normal tendon, but with persistent tendon scarring thickness. Conclusions: There is a fast reparative process after Achilles tendon percutaneous section that reestablishes continuity between stumps. The reparative tissue evolved to tendon tissue with a normal ultrasonographic appearance except for mild thickening, suggesting a predominantly intrinsic repair mechanism.
Resumo:
P>Aim To present a 52-year-old male patient who complained of intense pain of short duration in the region of the left external ear and in the ipsilateral maxillary second molar that was relieved by blockade of the auriculotemporal nerve in the infratemporal fossa. Summary Extra- and intraoral physical examination revealed a trigger point that reproduced the symptoms upon finger pressure in the ipsilateral auriculotemporal nerve and in the outer auricular pavilion. The patient`s medical history was unremarkable. The maxillary left second molar tooth was not responsive to pulp sensitivity testing and there was no pain upon percussion or palpation of the buccal sulcus. Periapical radiographs revealed a satisfactory root filling in the maxillary left second molar. On the basis of the clinical signs and symptoms, the auriculotemporal was blocked with 0.5 mL 2% lidocaine and 0.5 mL of a suspension containing dexamethasone acetate (8 mg mL(-1)) and dexamethasone disodium sulfate (2 mg mL(-1)), with full remission of pain 6 months later. The diagnosis was auriculotemporal neuralgia. Key learning point Auriculotemporal neuralgia should be considered as a possible cause of nonodontogenic toothache and thus included in the differential diagnoses. The blockade of the auriculotemporal nerve in the infratemporal fossa is diagnostic and therapeutic. It can be achieved with a solution of lidocaine and dexamethasone.