934 resultados para PROTECTIVE-VENTILATION
Resumo:
Case study simulations with idealized tracers have been used to determine the relationship between the dynamics and conceptual representations of different midlatitude frontal systems and the amount, distribution, and time scale of boundary layer ventilation by these systems. The key features of ventilation by a kata– and ana–cold frontal system are found to be quantitatively and also often qualitatively similar to the main ventilation pathways, which are the conveyor belts, cloud head, and other convection. The conveyor belts and cloud head occur within cloud, implying that they can be identified using satellite imagery. Differences in the transport by the two systems can be related to their conceptual representations and include a sensitive dependence on the diurnal cycle for the kata- but not the ana-cold frontal case.
Resumo:
As part of the broader prevention and social inclusion agenda, concepts of risk, resilience, and protective factors inform a range of U.K. Government initiatives targeted towards children and young people in England, including Sure Start, the Children's Fund, On Track, and Connexions. This paper is based on findings from a large qualitative dataset of interviews conducted with children and their parents or caregiver who accessed Children's Fund services as part of National Evaluation of the Children's Fund research.1 Drawing on the notion of young people's trajectories, the paper discusses how Children's Fund services support children's and young people's pathways towards greater social inclusion. While many services help to build resilience and protective factors for individual children, the paper considers the extent to which services also promote resilience within the domains of the family, school, and wider community and, hence, attempt to tackle the complex, multi-dimensional aspects of social exclusion affecting children, young people, and their families.
Resumo:
Thermometer screen properties are poorly characterised at low wind speeds. Temperatures from a large thermometer screen have been compared with those from an automatically shaded open-air fine-wire resistance thermometer. For the majority of 5-minute average measurements obtained between July 2008 and 2009, the screen and fine-wire temperatures agreed closely, with a median difference <0.05◦C. At low wind speeds however, larger temperature differences occurred. When calm (wind speed at 2 metres, u2, ≤ 0.1 m s−1), the difference between screen and open-air temperatures varied from −0.25◦C to +0.87◦C. At night with u2 < 0.5 m s−1, this difference was −0.14◦C to 0.39◦C, and, rarely, up to −0.68◦C to 1.38◦C. At the minimum in the daily temperature cycle, the semi-urban site at Reading had u2 < 1 m s−1 for 52% of the observations 1997–2008, u2 < 0.5 m s−1 for 34% and calm conditions for 20%. Consequently uncertainties in the minimum temperature measurements may arise from poor ventilation, which can propagate through calculations to daily average temperatures. In comparison with the daily minimum temperature, the 0900 UTC synoptic temperature measurement has a much lower abundance (5%) of calm conditions.
Resumo:
Midlatitude cyclones are important contributors to boundary layer ventilation. However, it is uncertain how efficient such systems are at transporting pollutants out of the boundary layer, and variations between cyclones are unexplained. In this study 15 idealized baroclinic life cycles, with a passive tracer included, are simulated to identify the relative importance of two transport processes: horizontal divergence and convergence within the boundary layer and large-scale advection by the warm conveyor belt. Results show that the amount of ventilation is insensitive to surface drag over a realistic range of values. This indicates that although boundary layer processes are necessary for ventilation they do not control the magnitude of ventilation. A diagnostic for the mass flux out of the boundary layer has been developed to identify the synoptic-scale variables controlling the strength of ascent in the warm conveyor belt. A very high level of correlation (R-2 values exceeding 0.98) is found between the diagnostic and the actual mass flux computed from the simulations. This demonstrates that the large-scale dynamics control the amount of ventilation, and the efficiency of midlatitude cyclones to ventilate the boundary layer can be estimated using the new mass flux diagnostic. We conclude that meteorological analyses, such as ERA-40, are sufficient to quantify boundary layer ventilation by the large-scale dynamics.
Resumo:
Two types of neem formulations, crude and refined, were tested. The crude form was neem leaves and neem cakes (a by-product left after the extraction of oil from neem seed) and one of the neem-refined products was "aza". The protective and curative soil application of these formulations significantly reduced the number of egg masses and eggs per egg mass on tomato roots. Protective application of neem crude formulations (leaves and cake) did not reduce the invasion of juveniles whereas aza at 0.1% w/w did. Curative application of neem formulations significantly reduced the number of egg masses and eggs per egg mass as compared with the control. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
The in vitro antioxidant activity and the protective effect against human low density lipoprotein oxidation of coffees prepared using different degrees of roasting was evaluated. Coffees with the highest amount of brown pigments (dark coffee) showed the highest peroxyl radical scavenging activity. These coffees also protected human low-density lipoprotein (LDL) against oxidation, although green coffee extracts showed more protection. In a different experiment, coffee extracts were incubated with human plasma prior to isolation of LDL particles. This showed, for the first time, that incubation of plasma with dark, but not green coffee extracts protected the LDL against oxidation by copper or by the thermolabile azo compound AAPH. Antioxidants in the dark coffee extracts must therefore have become associated with the LDL particles. Brown compounds, especially those derived from the Maillard reaction, are the compounds most likely to be responsible for this activity.
Resumo:
Recently, studies have shown that the classroom environment is very important for students' health and performance. Thus, the evaluation of indoor air quality (IAQ) in a classroom is necessary to ensure students' well-being. In this paper the emphasis is on airborne concentration of particulate matter (PM) in adult education rooms. The mass concentration of PM10 particulates was measured in two classrooms under different ventilation methods in the University of Reading, UK, during the winter period of 2008. In another study the measurement of the concentration of particles was accompanied with measurements of CO2 concentration in these classrooms but this study is the subject of another publication. The ambient PM10, temperature, relative humidity, wind speed and direction, and rainfall events were monitored as well. In general, this study showed that outdoor particle concentrations and outdoor meteorological parameters were identified as significant factors influencing indoor particle concentration levels. Ventilation methods showed significant effects on air change rate and on indoor/outdoor (I/O) concentration ratios. Higher levels of indoor particulates were seen during occupancy periods. I/O ratios were significantly higher when classrooms were occupied than when they were unoccupied, indicating the effect of both people presence and outdoor particle concentration levels. The concentrations of PM10 indoors and outdoors did not meet the requirements of WHO standards for PM10 annual average.
Resumo:
Research shows that poor indoor air quality (IAQ) in school buildings can cause a reduction in the students’ performance assessed by short-term computer-based tests; whereas good air quality in classrooms can enhance children's concentration and also teachers’ productivity. Investigation of air quality in classrooms helps us to characterise pollutant levels and implement corrective measures. Outdoor pollution, ventilation equipment, furnishings, and human activities affect IAQ. In school classrooms, the occupancy density is high (1.8–2.4 m2/person) compared to offices (10 m2/person). Ventilation systems expend energy and there is a trend to save energy by reducing ventilation rates. We need to establish the minimum acceptable level of fresh air required for the health of the occupants. This paper describes a project, which will aim to investigate the effect of IAQ and ventilation rates on pupils’ performance and health using psychological tests. The aim is to recommend suitable ventilation rates for classrooms and examine the suitability of the air quality guidelines for classrooms. The air quality, ventilation rates and pupils’ performance in classrooms will be evaluated in parallel measurements. In addition, Visual Analogue Scales will be used to assess subjective perception of the classroom environment and SBS symptoms. Pupil performance will be measured with Computerised Assessment Tests (CAT), and Pen and Paper Performance Tasks while physical parameters of the classroom environment will be recorded using an advanced data logging system. A total number of 20 primary schools in the Reading area are expected to participate in the present investigation, and the pupils participating in this study will be within the age group of 9–11 years. On completion of the project, based on the overall data recommendations for suitable ventilation rates for schools will be formulated.