919 resultados para PHOTOMETRIC STANDARD STARS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to compare the totally tubeless percutaneous nephrolithotomy and standard percutaneous nephrolithotomy techniques regarding their rates of success and complications in patients with kidney stones. Patients were randomly assigned to two groups. Forty-four patients (24 men; mean age: 50.40±2.02 years) received totally tubeless percutaneous nephrolithotomy (PCNL; no nephrostomy catheter or ureteral catheter after PCNL) and 40 patients (18 men; mean age: 49.95±13.38 years) underwent standard PCNL (a nephrostomy catheter and ureteral catheter were used after PCNL). All surgeries were performed by one surgeon. Postoperative changes in hemoglobin, the blood transfusion rate, changes in creatinine levels, operation time, analgesic need, hospitalization time, and complication rate were compared between the groups. No significant differences were observed in age, gender, stone size, and surgery side between the groups (P<0.05). The operation time was significantly lower in the totally tubeless PCNL group than in the standard PCNL group (P=0.005). Pethidine requirements were significantly higher in the standard PCNL group than the totally tubeless PCNL group (P=0.007). Hospitalization time was significantly higher in the standard PCNL group than in the totally tubeless PCNL group (P<0.0001). The complication rate was 15% in the standard PCNL group and 9.1% in the totally tubeless PCNL group (P=0.73). The totally tubeless PCNL technique is safe and effective, even for patients with staghorn stones. This technique is associated with decreased pain, analgesic needs, and operative and hospitalization time. We believe that a normal peristaltic ureter is the best drainage tube.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Continuous exposition of the peritoneal membrane to conventional dialysis solutions is an important risk factor for inducing structural and functional alterations. Objective: To compare in vitro mouse fibroblast NIH-3T3 cell viability after exposition to a neutral pH dialysis solution in comparison to cells exposed to a standard solution. Methods: Experimental study to compare the effects of a conventional standard or a neutral-pH, low-glucose degradation products peritoneal dialysis solution on the viability of exposed fibroblasts in cell culture. Both solutions were tested in all the commercially available glucose concentrations. Cell viability was evaluated with tetrazolium salt colorimetric assay. Results: Fibroblast viability was significantly superior in the neutral pH solution in comparison to control, in all three glucose concentrations (Optical density in nm-means ± SD: 1.5% 0.295 ± 0.047 vs. 0.372 ± 0.042, p < 0.001; 2.3% 0.270 ± 0.036 vs. 0.337 ± 0.051, p < 0.001; 4.25% 0.284 ± 0.037 vs. 0.332 ± 0.032, p < 0.001; control vs. neutral pH respectively, Student t Test). There was no significant difference in cell viability between the three concentrations of glucose when standard solution was used (ANOVA p = 0.218), although cell viability was higher after exposition to neutral pH peritoneal dialysis fluid at 1.5% in comparison to 2.3 and 4.25% glucose concentrations (ANOVA p = 0.008: Bonferroni 1.5% vs. 2.3% p = 0.033, 1.5% vs. 4.25% p = 0.014, 2.3% vs. 4.25% p = 1.00). Conclusion: Cell viability was better in neutral pH dialysis solution, especially in the lower glucose concentration. A more physiological pH and lower glucose degradation products may be responsible for such results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Finnish design and consulting companies are delivering robust and cost-efficient steel structures solutions to a large number of manufacturing companies worldwide. Recently introduced EN 1090-2 standard obliges these companies to specify the execution class of steel structures for their customers. This however, requires clarifying, understanding and interpreting the sophisticated procedure of execution class assignment. The objective of this research is to provide a clear explanation and guidance through the process of execution class assignment for a given steel structure and to support the implementation of EN 1090-2 standard in Rejlers Oy, one of Finnish design and consulting companies. This objective is accomplished by creating a guideline for designers that elaborates on the four-step process of the execution class assignment for a steel structure or its part. Steps one to three define the consequence class (projected consequences of structure failure), the service category (hazards associated with the service use exploitation of steel structure) and the production category (manufacturing process peculiarities), based on the ductility class (capacity of structure to withstand deformations) and the behaviour factor (corresponds to structure seismic behaviour). The final step is the execution class assignment taking into account results of previous steps. Main research method is indepth literature review of European standards family for steel structures. Other research approach is a series of interviews of Rejlers Oy representatives and its clients, results of which have been used to evaluate the level of EN 1090-2 awareness. Rejlers Oy will use the developed novel coherent standard implementation guideline to improve its services and to obtain greater customer satisfaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Suomessa ja muissa Pohjoismaissa on tunnistettu haasteita kansainvälisten tilintarkastusstandardien eli ISA-standardien soveltamisessa pienten yhtiöiden tilintarkastuksiin. ISA-standardien on kritisoitu sisältävän liian yksityiskohtaisia ja jopa epärealistisia vaatimuksia ajatellen pienien yhtiöiden tilintarkastuksia. Pohjoismaisella yhteistyöllä onkin alettu kehittää omaa standardia pienten yhtiöiden tilintarkastuksiin. Niin sanotun SASE-standardin on raportoitu muun muassa korostavan tilintarkastajan ammatillista harkintaa ja keventävän pienten yhtiöiden tilintarkastuksen vaatimuksia. Koska kuitenkin aikaisemmin sääntelyn lisäämisellä on pyritty muun muassa lisääntyneeseen tilintarkastuksen luotettavuuteen, josta myös pienten yhtiöiden on itse tutkittu hyötyvän, on tutkimuksessa haluttu selvittää, miten kehitteillä olevan SASE-standardin arvioidaan vaikuttavan yleisesti pienten yhtiöiden tilintarkastuksella saavutettaviin hyötyihin. Tutkimus on toteutettu toiminta-analyyttisena laadullisena tutkimuksena, ja tutkimusmetodina on käytetty tilintarkastajien ja yliopiston tutkijatohtorin haastatteluja. Tutkimuksen tulosten mukaan kehitteillä olevan SASE-standardin arvioidaan vaikuttavan pienten yhtiöiden tilintarkastuksen hyötyihin kaksisuuntaisesti. Toisaalta SASE-standardi voi lisätä tilintarkastuksen hyötyjä, koska tilintarkastaja voisi keskittyä tarkastuskohteen kannalta olennaisempiin asioihin, hyödyntää hiljaista tietoaan sekä lisätä vuorovaikutusta yhtiön omistajajohdon kanssa. SASE-standardin ei arvioida muuttavan juurikaan käytännön tilintarkastustyötä ja periaatteessa olennaisuuksiin keskittymisen ja riskien tehokkaamman tunnistamisen tulisi hyödyttää myös tilintarkastuskohteen ulkoisia sidosryhmiä, kuten rahoittajia. Kuitenkin tutkimuksessa nousi esiin SASE-standardin mahdollinen heikko maine. Mikäli SASE-standardia pidettäisiin vähäpätöisempänä tai epäluotettavampana kuin aikaisempaa käytäntöä, luottamus tilintarkastusta ja tarkastuskohdetta kohtaan heikkenisi ja sitä kautta myös tilintarkastuksen hyödyt pienenisivät. Tutkimuksen johtopäätöksenä voidaan esittää, että tilintarkastuksen sääntelyn keventämisen vaikutus tilintarkastuksen hyötyihin ei niinkään synny käytännön työn kautta. Tilintarkastuksen hyötyihin pikemminkin vaikuttavat maineeseen, viestintään ja vuorovaikutukseen liittyvät seikat. Toimivalla vuorovaikutuksella yhtiön omistajajohdon ja tilintarkastajan välillä voidaan tilintarkastuksen hyötyjä korostaa, ja toisaalta taas riittävällä ulkoisiin sidosryhmiin kohdistuvalla tiedottamisella voidaan hyötyjen heikkenemistä ehkäistä. Keskeiseksi seikaksi tutkimuksessa nousee se, että tilintarkastuksen luotettavuuden ja tason säilyminen on pystyttävä todistamaan.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Internet of Things or IoT is revolutionizing the world we are living in, similarly the way Internet and the web did few decades ago. It is changing how we interact with the things surrounding us. Electronic health and remote patient monitoring are the ways of utilizing these technological improvements towards the healthcare. There are many applications of IoT in eHealth such as, it will open the gate to provide healthcare to the remote areas of the world, where healthcare through traditional hospital systems cannot be provided. To connect these new eHealth IoT systems with the existing healthcare information systems, we can use the existing interoperability standards commonly used in healthcare information systems. In this thesis we implemented an eHealth IoT system based on Health Level 7 interoperability standard for continuous data transmission. There is not much previous work done in implementing the HL7 for continuous sensor data transmission. Some of the previous work was limited to sensors which are not continuous in nature and some of it is only theatrical architecture. This thesis aims to prove that it is possible to implement an eHealth IoT system by using sensors which require continues data transmission, such as respiratory sensors, and to connect it with the existing eHealth information system semantically by using HL7 interoperability standard. This system will be beneficial in implementing eHealth IoT systems for those patients, who requires continuous healthcare personal monitoring. This includes elderly people and patients, whose health need to be monitored constantly. To implement the architecture, HL7 v2.5 is selected due to its ease of implementation and low size. We selected some open source technologies because of their open licenses and large developer community. We will also review the most efficient technology available in every layer of eHealth IoT system and will propose an efficient system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bank stabilization structures are used to prevent the loss of valuable land within the urban environment and the decision for the type of structure used depends on the properties of the stream. In the urban areas of Southern Ontario there is a preference for the use of armourstone blocks as bank stabilization. The armourstone revetment is a free standing stone structure with large blocks of stone layered vertically and offset from one another. During fieldwork at Forty Mile Creek in Grimsby, Ontario armourstone failure was identified by the removal of two stones within one column from the wall. Since the footer stones were still in place, toe scour was eliminated as a cause of failure. Through theoretical, field, and experimental work the process of suction has been identified as a mode of failure for the armourstone wall and the process of suction works similarly to quarrying large blocks of rock off bedrock streambeds. The theory of lateral suction has previously not been taken into consideration for the design of these walls. The physical and hydraulic evidence found in the field and studied during experimental work indicate that the armourstone wall is vulnerable to the process of suction. The forces exerted by the flow and the resistance of the block determine the stability of the armourstone block within the wall. The design of the armourstone wall, high surface velocities, and short pulses of faster flowing water within the profile could contribute to armourstone failure by providing the forces needed for suction to occur, therefore adjustments to the design of the wall should be made in order to limit the effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The St. Catharines Standard started publication in 1891 under W.B. Burgoyne. It was subsequently purchased by Southam Newspapers, then Canwest Global Communications. Osprey Media took over the publication until June 1, 2007 when Quebecor acquired the company. The St. Catharines Standard celebrated its centennial in 1991 with mobile displays, a centennial logo and slogan, a Christmas card, an advertising campaign, a video and a centennial theme to regular promotions. As part of the activities, the Standard commissioned Brock University to produce a history of St. Catharines. This book entitled St. Catharines Canada’s Canal City is a popular book rather than an academic text. The authors have woven together stories of the past and present to showcase the character and personality of St. Catharines. The book is full of maps and photographs, many of which had not been seen in print before this time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A photograph and brief comment about the race results for Dorothy Rungeling. She is photographed next to George Belfry of Thompson Products (sponsor), Alice Little (co-pilot) and radio broadcaster Rex Stimers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Daily Standard, St. Catharines, Ontario. This paper contains an advertisement for James D. Tait Company and H.K. Woodruff is listed under the article “The Voice of the People” as an elected member of the Water Commission and an alderman January 2, 1900.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The St. Catharines Standard supplement featuring a Tribute to the Father of Transportation, the Honorable William Hamilton Merritt, November 28, 1974.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Un résumé en anglais est également disponible. Le présent document a été présenté pour l'obtention du diplôme de Maîtrise en droit. Le ménoire a été accepté et classé parmi les 5% de la discipline.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L’étoile Wolf-Rayet WR 46 est connue pour sa variabilité complexe sur des échelles de temps relativement courtes de quelques heures et sur des échelles de temps plus longues de plusieurs mois. Des décalages périodiques mais intermittents en vitesse radiale ont déjà été observés dans ses raies d’émission optiques. Plusieurs périodes photométriques ont aussi été mesurées dans le passé. Des pulsations non-radiales, une modulation liée à la rotation rapide, ou encore la présence d’un compagnon de faible masse dont la présence reste à confirmer ont été proposées pour expliquer le comportement de l’étoile sur des échelles de temps de quelques heures. Dans un effort pour dévoiler sa vraie nature, nous avons observé WR 46 avec le satellite FUSE sur plusieurs cycles de variabilité à court terme. Nous avons trouvé des variations sur une échelle de temps d’environ 7,5 heures dans le continu ultraviolet lointain, dans l’aile bleue de la composante d’absorption du profil P Cygni du doublet de O vi 1032, 1038, ainsi que dans la composante d’absorption du profil P Cygni de S vi 933, 944. Nous avons également récupéré des données archivées de cette étoile obtenues avec le satellite XMM-Newton. La courbe de lumière en rayons X montre des variations sur une échelle de temps similaire aux courbes de lumière du continu ultraviolet et ultraviolet lointain, et le spectre rayons X de WR 46 est très mou avec un pic d’émission à des énergies plus faibles que 1 keV. Nous discutons des différentes contraintes sur la nature de la variabilité de cette étoile que ces nouvelles observations aident à poser. Parmi les scénarios suggérés, nous concluons que celui des pulsations non-radiales est le plus probable, bien que nous soyons encore loin d’une compréhension détaillée de WR 46.