471 resultados para Orthopedics.
Resumo:
INTRODUCTION The aims of this study were to compare lateral cephalograms with other radiologic methods for diagnosing suspected fusions of the cervical spine and to validate the assessment of congenital fusions and osteoarthritic changes against the anatomic truth. METHODS Four cadaver heads were selected with fusion of vertebrae C2 and C3 seen on a lateral cephalogram. Multidetector computed tomography (MDCT) and cone-beam computed tomography (CBCT) were performed and assessed by 5 general radiologists and 5 oral radiologists, respectively. Vertebrae C2 and C3 were examined for osseous fusions, and the left and right facet joints were diagnosed for osteoarthritis. Subsequently, the C2 and C3 were macerated and appraised by a pathologist. Descriptive analysis was performed, and interrater agreements between and within the groups were computed. RESULTS All macerated specimens showed osteoarthritic findings of varying degrees, but no congenital bony fusion. All observers agreed that no fusion was found on MDCT or CBCT. They disagreed on the prevalence of osteoarthritic deformities (general radiologists/MDCT, 100%; oral radiologists/CBCT, 93.3%) and joint space assessment in the facet joints (kappa = 0.452). The agreement within the rater groups differed considerably (general radiologists/MDCT, kappa = 0.612; oral radiologists/CBCT, kappa = 0.240). CONCLUSIONS Lateral cephalograms do not provide dependable data to assess the cervical spine for fusions and cause false-positive detections. Both MDCT interpreted by general radiologists and CBCT interpreted by oral radiologists are reliable methods to exclude potential fusions. Degenerative osteoarthritic changes are diagnosed more accurately and consistently by general radiologists evaluating MDCT.
Resumo:
The aims of this study were to assess and compare the methodological quality of Cochrane and non-Cochrane systematic reviews (SRs) published in leading orthodontic journals and the Cochrane Database of Systematic Reviews (CDSR) using AMSTAR and to compare the prevalence of meta-analysis in both review types. A literature search was undertaken to identify SRs that consisted of hand-searching five major orthodontic journals [American Journal of Orthodontics and Dentofacial Orthopedics, Angle Orthodontist, European Journal of Orthodontics, Journal of Orthodontics and Orthodontics and Craniofacial Research (February 2002 to July 2011)] and the Cochrane Database of Systematic Reviews from January 2000 to July 2011. Methodological quality of the included reviews was gauged using the AMSTAR tool involving 11 key methodological criteria with a score of 0 or 1 given for each criterion. A cumulative grade was given for the paper overall (0-11); an overall score of 4 or less represented poor methodological quality, 5-8 was considered fair and 9 or greater was deemed to be good. In total, 109 SRs were identified in the five major journals and on the CDSR. Of these, 26 (23.9%) were in the CDSR. The mean overall AMSTAR score was 6.2 with 21.1% of reviews satisfying 9 or more of the 11 criteria; a similar prevalence of poor reviews (22%) was also noted. Multiple linear regression indicated that reviews published in the CDSR (P < 0.01); and involving meta-analysis (β = 0.50, 95% confidence interval 0.72, 2.07, P < 0.001) showed greater concordance with AMSTAR.
Resumo:
Cam-type deformity of the proximal femur is a risk factor for the development of cam-type femoroacetabular impingement and a prearthrotic condition of the hip. The etiology of cam-type deformity remains unclear. There are a number of causes of cam-type deformity including sequellae of slipped capital femoral epiphysis, Legg-Calvé-Perthes disease or Perthes-like deformities, postinfectious, and traumatic. However, the majority of cam-type deformities arise without any apparent preexisting hip disease. These "idiopathic" cam-type deformities likely represent a majority of cases, and show clear racial and sex differences, as well as developmental and genetic influences. Idiopathic cam-type deformity also seems to be a distinct entity from residual or silent slipped capital femoral epiphysis, as well as osteoarthritis-induced osteophytes. In this paper we examine the different pathogenetic aspects of the proximal femur that contribute to cam-type deformity and/or symptomatic cam-type femoroacetabular impingement.
Resumo:
AIM: To investigate the acute effects of stochastic resonance whole body vibration (SR-WBV) training to identify possible explanations for preventive effects against musculoskeletal disorders. METHODS: Twenty-three healthy, female students participated in this quasi-experimental pilot study. Acute physiological and psychological effects of SR-WBV training were examined using electromyography of descending trapezius (TD) muscle, heart rate variability (HRV), different skin parameters (temperature, redness and blood flow) and self-report questionnaires. All subjects conducted a sham SR-WBV training at a low intensity (2 Hz with noise level 0) and a verum SR-WBV training at a higher intensity (6 Hz with noise level 4). They were tested before, during and after the training. Conclusions were drawn on the basis of analysis of variance. RESULTS: Twenty-three healthy, female students participated in this study (age = 22.4 ± 2.1 years; body mass index = 21.6 ± 2.2 kg/m2). Muscular activity of the TD and energy expenditure rose during verum SR-WBV compared to baseline and sham SR-WBV (all P < 0.05). Muscular relaxation after verum SR-WBV was higher than at baseline and after sham SR-WBV (all P < 0.05). During verum SR-WBV the levels of HRV were similar to those observed during sham SR-WBV. The same applies for most of the skin characteristics, while microcirculation of the skin of the middle back was higher during verum compared to sham SR-WBV (P < 0.001). Skin redness showed significant changes over the three measurement points only in the middle back area (P = 0.022). There was a significant rise from baseline to verum SR-WBV (0.86 ± 0.25 perfusion units; P = 0.008). The self-reported chronic pain grade indicators of pain, stiffness, well-being, and muscle relaxation showed a mixed pattern across conditions. Muscle and joint stiffness (P = 0.018) and muscular relaxation did significantly change from baseline to different conditions of SR-WBV (P < 0.001). Moreover, muscle relaxation after verum SR-WBV was higher than after sham SR-WBV (P < 0.05). CONCLUSION: Verum SR-WBV stimulated musculoskeletal activity in young healthy individuals while cardiovascular activation was low. Training of musculoskeletal capacity and immediate increase in musculoskeletal relaxation are potential mediators of pain reduction in preventive trials.
Resumo:
The use of smaller surgical incisions has become popularized for total hip arthroplasty (THR) because of the potential benefits of shorter recovery and improved cosmetic appearance. However, an increased incidence of serious complications has been reported. To minimize the risks of minimally invasive approaches to THR, we have developed an experimental approach which enables us to evaluate risk factors in these procedures through cadaveric simulations performed within the laboratory. During cadaveric hip replacement procedures performed via posterior and antero-lateral mini-incisions, pressures developed between the wound edges and the retractors were approximately double those recorded during conventional hip replacement using Charnley retractors (p < 0.01). In MIS procedures performed via the dual-incision approach, lack of direct visualisation of the proximal femur led to misalignment of broaches and implants with increased risk of cortical fracture during canal preparation and implant insertion. Cadaveric simulation of surgical procedures allows surgeons to measure variables affecting the technical success of surgery and to master new procedures without placing patients at risk.
Resumo:
INTRODUCTION The aim of this study was to determine the reproducibility and accuracy of linear measurements on 2 types of dental models derived from cone-beam computed tomography (CBCT) scans: CBCT images, and Anatomodels (InVivoDental, San Jose, Calif); these were compared with digital models generated from dental impressions (Digimodels; Orthoproof, Nieuwegein, The Netherlands). The Digimodels were used as the reference standard. METHODS The 3 types of digital models were made from 10 subjects. Four examiners repeated 37 linear tooth and arch measurements 10 times. Paired t tests and the intraclass correlation coefficient were performed to determine the reproducibility and accuracy of the measurements. RESULTS The CBCT images showed significantly smaller intraclass correlation coefficient values and larger duplicate measurement errors compared with the corresponding values for Digimodels and Anatomodels. The average difference between measurements on CBCT images and Digimodels ranged from -0.4 to 1.65 mm, with limits of agreement values up to 1.3 mm for crown-width measurements. The average difference between Anatomodels and Digimodels ranged from -0.42 to 0.84 mm with limits of agreement values up to 1.65 mm. CONCLUSIONS Statistically significant differences between measurements on Digimodels and Anatomodels, and between Digimodels and CBCT images, were found. Although the mean differences might be clinically acceptable, the random errors were relatively large compared with corresponding measurements reported in the literature for both Anatomodels and CBCT images, and might be clinically important. Therefore, with the CBCT settings used in this study, measurements made directly on CBCT images and Anatomodels are not as accurate as measurements on Digimodels.
Resumo:
AIM Several surveys evaluate different retention approaches among orthodontists, but none exist for general dentists. The primary aim of this survey was to record the preferred fixed retainer designs and retention protocols amongst general dentists and orthodontists in Switzerland. A secondary aim was to investigate whether retention patterns were associated with parameters such as gender, university of graduation, time in practice, and specialist status. METHODS An anonymized questionnaire was distributed to general dentists (n = 401) and orthodontists (n = 398) practicing in the German-speaking part of Switzerland. A total of 768 questionnaires could be delivered, 562 (73.2 %) were returned and evaluated. Descriptive statistics were performed and responses to questions of interest were converted to binary outcomes and analyzed using multiple logistic regression. Any associations between the answers and gender, university of graduation (Swiss or foreign), years in practice, and specialist status (orthodontist/general dentist) were assessed. RESULTS Almost all responding orthodontists (98.0 %) and nearly a third of general dentists (29.6 %) reported bonding fixed retainers regularly. The answers were not associated with the practitioner's gender. The university of graduation and number of years in practice had a moderate impact on the responses. The answers were mostly influenced by specialist status. CONCLUSION Graduation school, years in practice, and specialist status influence retention protocol, and evidence-based guidelines for fixed retention should be issued to minimize these effects. Based on the observation that bonding and maintenance of retainers are also performed by general dentists, these guidelines should be taught in dental school and not during post-graduate training.
Resumo:
OBJECTIVES Accurate trial reporting facilitates evaluation and better use of study results. The objective of this article is to investigate the quality of reporting of randomized controlled trials (RCTs) in leading orthodontic journals, and to explore potential predictors of improved reporting. METHODS The 50 most recent issues of 4 leading orthodontic journals until November 2013 were electronically searched. Reporting quality assessment was conducted using the modified CONSORT statement checklist. The relationship between potential predictors and the modified CONSORT score was assessed using linear regression modeling. RESULTS 128 RCTs were identified with a mean modified CONSORT score of 68.97% (SD = 11.09). The Journal of Orthodontics (JO) ranked first in terms of completeness of reporting (modified CONSORT score 76.21%, SD = 10.1), followed by American Journal of Orthodontics and Dentofacial Orthopedics (AJODO) (73.05%, SD = 10.1). Journal of publication (AJODO: β = 10.08, 95% CI: 5.78, 14.38; JO: β = 16.82, 95% CI: 11.70, 21.94; EJO: β = 7.21, 95% CI: 2.69, 11.72 compared to Angle), year of publication (β = 0.98, 95% CI: 0.28, 1.67 for each additional year), region of authorship (Europe: β = 5.19, 95% CI: 1.30, 9.09 compared to Asia/other), statistical significance (significant: β = 3.10, 95% CI: 0.11, 6.10 compared to non-significant) and methodologist involvement (involvement: β = 5.60, 95% CI: 1.66, 9.54 compared to non-involvement) were all significant predictors of improved modified CONSORT scores in the multivariable model. Additionally, median overall Jadad score was 2 (IQR = 2) across journals, with JO (median = 3, IQR = 1) and AJODO (median = 3, IQR = 2) presenting the highest score values. CONCLUSION The reporting quality of RCTs published in leading orthodontic journals is considered suboptimal in various CONSORT areas. This may have a bearing in trial result interpretation and use in clinical decision making and evidence- based orthodontic treatment interventions.
Resumo:
OBJECTIVE To describe a novel CONsolidated Standards of Reporting Trials (CONSORT) adherence strategy implemented by the American Journal of Orthodontics and Dentofacial Orthopedics (AJO-DO) and to report its impact on the completeness of reporting of published trials. STUDY DESIGN AND SETTING The AJO-DO CONSORT adherence strategy, initiated in June 2011, involves active assessment of randomized clinical trial (RCT) reporting during the editorial process. The completeness of reporting CONSORT items was compared between trials submitted and published during the implementation period (July 2011 to September 2013) and trials published between August 2007 and July 2009. RESULTS Of the 42 RCTs submitted (July 2011 to September 2013), 23 were considered for publication and assessed for completeness of reporting, seven of which were eventually published. For all published RCTs between 2007 and 2009 (n = 20), completeness of reporting by CONSORT item ranged from 0% to 100% (Median = 40%, interquartile range = 60%). All published trials in 2011-2013, reported 33 of 37 CONSORT (sub) items. Four CONSORT 2010 checklist items remained problematic even after implementation of the adherence strategy: changes to methods (3b), changes to outcomes (6b) after the trial commenced, interim analysis (7b), and trial stopping (14b), which are typically only reported when applicable. CONCLUSION Trials published following implementation of the AJO-DO CONSORT adherence strategy completely reported more CONSORT items than those published or submitted previously.
Resumo:
Systematic reviews of well-designed trials constitute a high level of scientific evidence and are important for medical decision making. Meta-analysis facilitates integration of the evidence using a transparent and systematic approach, leading to a broader interpretation of treatment effectiveness and safety than can be attained from individual studies. Traditional meta-analyses are limited to comparing just 2 interventions concurrently and cannot combine evidence concerning multiple treatments. A relatively recent extension of the traditional meta-analytical approach is network meta-analysis, which allows, under certain assumptions, the quantitative synthesis of all evidence under a unified framework and across a network of all eligible trials. Network meta-analysis combines evidence from direct and indirect information via common comparators; interventions can therefore be ranked in terms of the analyzed outcome. In this article, the network meta-analysis approach is introduced in a nontechnical manner using a worked example on the treatment effectiveness of conventional and self-ligating appliances.
Resumo:
OBJECTIVE To analyze the types of articles and authorship characteristics of three orthodontic journals--American Journal of Orthodontics and Dentofacial Orthopedics (AJODO), The Angle Orthodontist (AO), and European Journal of Orthodontics (EJO)--published between 2008 and 2012 and to assess the differences in content within this period and an earlier period of 1998 to 2002. MATERIALS AND METHODS Each journal's content was accessed through the web edition. From each article, the following parameters were recorded: article type, number of authors, number of affiliations, source of article (referring to the first author's affiliation), and geographic origin. Descriptive statistics were performed and selected parameters were analyzed with the Pearson chi-square or Fisher exact test for independence at the .05 level of significance. RESULTS Review of differences between the two periods showed that the number of publications was almost double. The percentages of multi-authored articles increased. Fewer studies derived from the United States/Canada and European Union countries. Increases for articles from non-European Union countries, Asia, and other countries were found. Characteristics of the second period showed that the EJO and AO published more research articles, whereas the AJODO regularly published case reports and other articles. Approximately 75% of all studies derived from orthodontic departments. CONCLUSIONS The publications from 1998-2002 and 2008-2012 were significantly different both in terms of numbers and characteristics. Within 2008-2012 there were notable differences between the three journals concerning the type and origin of the publications.