775 resultados para Observers
Resumo:
Purpose: To evaluate the accuracy of approximal caries detection comparing enhanced and unenhanced Sidexis CCD-based digital image with Ektaspeed Plus and INSIGHT films. Methods: Fifty-two extracted premolars were imaged under identical standardized geometric and exposure conditions. Four observers, using five points confidence scale, rated 104 approximal surfaces for the presence or absence of carious lesions by means of four image modalities: (1) observer enhanced; (2) unenhanced Sidexis displays; (3) E speed films and (4) F speed film. Histologic sections served as validating criterion for the presence and depth of carious lesions. Diagnostic accuracy was measured as the area beneath the ROC curve. Results: Mean ROC (receiver operating characteristic) curve areas for approximal surfaces were 0.865 (E speed), 0.856 (F speed), 0.816 (unenhanced Sidexis) and 0.776 (observer enhanced). There were no significant differences between unenhanced digital Sidexis and films. Observer enhanced Sidexis images exhibited a statistically significant lower diagnostic accuracy than the film images for two of the observers.
Resumo:
We show that the emission of a Minkowski particle by a general class of scalar sources as described by inertial observers corresponds to either the emission or the absorption of a Rindler particle as described by uniformly accelerated observers. Our results are discussed in connection with the current controversy whether uniformly accelerated detectors radiate.
Resumo:
We show that static sources coupled to a massless scalar field in Schwarzschild spacetime give rise to emission and absorption of zero-energy particles due to the presence of Hawking radiation. This is in complete analogy with the description of the bremsstrahlung by a uniformly accelerated charge from the coaccelerated observers' point of view. The response rate of the source is found to coincide with that in Minkowski spacetime as a function of its proper acceleration. It is interesting that this quantum result appears to reflect the classical equivalence principle.
Resumo:
A new concept of fault detection and isolation using robust observation for systems with random noises is presented. The method selects the parameters from components that may fault during the process and constructs well conditioned robust observers, considering sensors faults. To isolate component failures via robust observation, a bank of detection observers is constructed, where each observer is only sensitive to one specified component failure while robust to all other component failures.
Resumo:
A study of eye movements during simulated travel toward a grove of four stationary trees revealed that observers looked most at pairs of trees that converged or decelerated apart. Such pairs specify that one's direction of travel, called heading, is to the outside of the near member of the pair. Observers looked at these trees more than those that accelerated apart; such pairs do not offer trustworthy heading information. Observers also looked at gaps between trees less often when they converged or diverged apart, and heading can never be between such pairs. Heading responses were in accord with eye movements. In general, if observers responded accurately, they had looked at trees that converged or decelerated apart; if they were inaccurate, they had not. Results support the notion that observers seek out their heading through eye movements, saccading to and fixating on the most informative locations in the field of view.
Resumo:
The state observers can reconstruct and monitor unmeasurable states. A new concept of fault detection and isolation using state observers is presented. The method selects the parameters from components that may fail during the process and constructs optimized robust observers. To isolate component failures via robust observation, a bank of detection observers is organized, in which each observer is only sensitive to one specified component failure while robust to all other component failures. This paper analyzes the performance of transient and steady-state behavior of the state observer.
Resumo:
Objectives: The objective of this study was to evaluate by a visual method of comparison the color stability of nonpigmented and pigmented facial silicones after accelerated aging. Materials and Methods: Two kinds of silicones were used in this study; one specifically formulated for facial prostheses and the other an acetic silicone for industrial use. Twenty-four trial bodies were made for each silicone. These were divided into colorless and intrinsically pigmented groups: ceramic, make-up, and iron oxide. The groups were submitted to accelerated aging for nonmetallic materials. An initial reading and subsequent readings were made at 163, 351, 692, and 1000 hours using a visual method of comparison. The values were annotated in a spreadsheet by two observers, according to scores elaborated for this study. Results: All groups presented color stability in the visual method. According to the results obtained and analyzed in this study, we can conclude that both silicones, Silastic 732 RTV and Silastic MDX 4-4210, behaved similarly, they can therefore be indicated for use in maxillofacial prosthesis. The time factor of aging influenced negatively, independently of the pigmentation, or lack of it, and of silicones and no group had visually noticeable alterations in any of the accelerated aging time, independently of the addition or not of pigments.
Resumo:
Nowadays, one of the most important concerns for many companies is to maintain the operation of their systems without sudden equipment break down. Because of this, new techniques for fault detection and location in mechanical systems subject to dynamic loads have been developed. This paper studies of the influence of the decay rate in the design of state observers using LMI for fault detection in mechanical systems. This influence is analyzed by the performance index proposed by Huh and Stein for the condition of a state observer. An example is presented to illustrate the methodology discussed.
Resumo:
This work pointed out forming elements from the conception of special necessities that the media show the audience by the movies. An expression description has established special needs and they were identified as keywords on a search of movies (1994-2004) which were analyzed by two observers, according to a script. The results showed that 33 of the movies selected, 39.9% were classified in the ramacategory; 64% shows the disability as organic nature and 57% with predominant clinic diagnoses. Many labeled practices were identified (85%) and few accessibilities options (76%). In 85% of the movies the disability is said a manifestation of problems with few (58%) professionals intervention. The results are discussed by the media role on the concept formation of disabilities, offering interaction models with important role on social practice specification or unsuitable to the relation with the diversity and to the culture.
Resumo:
Includes Bibliography
Resumo:
Includes bibliography
Resumo:
Includes bibliography
Resumo:
Includes bibliography
Resumo:
Includes bibliography
Resumo:
Objectives: The aim of this study was to compare cone beam CT (CBCT) in a small field of view (FOV) with a solid-state sensor and a photostimulable phosphor plate system for detection of cavitated approximal surfaces. Methods: 257 non-filled approximal surfaces from human permanent premolars and molars were recorded by two intraoral digital receptors, a storage phosphor plate (Digora Optime, Soredex) and a solid-state CMOS sensor (Digora Toto, Soredex), and scanned in a cone beam CT unit (3D Accuitomo FPD80, Morita) with a FOV of 4 cm and a voxel size of 0.08 mm. Image sections were carried out in the axial and mesiodistal tooth planes. Six observers recorded surface cavitation in all images. Validation of the true absence or presence of surface cavitation was performed by inspecting the surfaces under strong light with the naked eye. Differences in sensitivity, specificity and agreement were estimated by analysing the binary data in a generalized linear model using an identity link function. Results: A significantly higher sensitivity was obtained by all observers with CBCT (p,0.001), which was not compromised by a lower specificity. Therefore, a significantly higher overall agreement was obtained with CBCT (p,0.001). There were no significant differences between the Digora Optime phosphor plate system and the Digora Toto CMOS sensor for any parameter. Conclusions: CBCT was much more accurate in the detection of surface cavitation in approximal surfaces than intraoral receptors. The differences are interpreted as clinically significant. A CBCT examination performed for other reasons should also be assessed for approximal surface cavities in teeth without restorations. © 2013 The British Institute of Radiology.