618 resultados para Morbus Fabry


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcriptional silencing of genes transferred into hematopoietic stem cells poses one of the most significant challenges to the success of gene therapy. If the transferred gene is not completely silenced, a progressive decline in gene expression as the mice age often is encountered. These phenomena were observed to various degrees in mouse transplant experiments using retroviral vectors containing a human β-globin gene, even when cis-linked to locus control region derivatives. Here, we have investigated whether ex vivo preselection of retrovirally transduced stem cells on the basis of expression of the green fluorescent protein driven by the CpG island phosphoglycerate kinase promoter can ensure subsequent long-term expression of a cis-linked β-globin gene in the erythroid lineage of transplanted mice. We observed that 100% of mice (n = 7) engrafted with preselected cells concurrently expressed human β-globin and the green fluorescent protein in 20–95% of their RBC for up to 9.5 mo posttransplantation, the longest time point assessed. This expression pattern was successfully transferred to secondary transplant recipients. In the presence of β-locus control region hypersensitive site 2 alone, human β-globin mRNA expression levels ranged from 0.15% to 20% with human β-globin chains detected by HPLC. Neither the proportion of positive blood cells nor the average expression levels declined with time in transplanted recipients. Although suboptimal expression levels and heterocellular position effects persisted, in vivo stem cell gene silencing and age-dependent extinction of expression were avoided. These findings support the further investigation of this type of vector for the gene therapy of human hemoglobinopathies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente trabalho está fundamentado no desenvolvimento de uma metodologia e/ou uma tecnologia de obtenção e caracterização de filtros ópticos de interferência de banda passante variável [C.M. da Silva, 2010] e de banda de corte variáveis, constituídos por refletores dielétricos multicamadas de filmes finos intercalados por cavidades de Fabry-Perot não planares com espessuras linearmente variáveis, que apresentam a propriedade do deslocamento linear da transmitância máxima espectral em função da posição, isto é, um Filtro de Interferência Variável (FIV). Este método apresenta novas e abrangentes possibilidades de confecção de filtros ópticos de interferência variável: lineares ou em outras formas desejadas, de comprimento de onda de corte variável (passa baixa ou alta) e filtros de densidade neutra variável, através da deposição de metais, além de aplicações em uma promissora e nova área de pesquisa na deposição de filmes finos não uniformes. A etapa inicial deste desenvolvimento foi o estudo da teoria dos filtros ópticos dielétricos de interferência para projetar e construir um filtro óptico banda passante convencional de um comprimento de onda central com camadas homogêneas. A etapa seguinte, com base na teoria óptica dos filmes finos já estabelecida, foi desenvolver a extensão destes conhecimentos para determinar que a variação da espessura em um perfil inclinado e linear da cavidade entre os refletores de Bragg é o principal parâmetro para produzir o deslocamento espacial da transmitância espectral, possibilitando o uso de técnicas especiais para se obter uma variação em faixas de bandas de grande amplitude, em um único filtro. Um trabalho de modelagem analítica e análise de tolerância de espessuras dos filmes depositados foram necessários para a seleção da estratégia do \"mascaramento\" seletivo do material evaporado formado na câmara e-Beam (elétron-Beam) com o objetivo da obtenção do filtro espectral linear variável de características desejadas. Para tanto, de acordo com os requisitos de projeto, foram necessárias adaptações em uma evaporadora por e-Beam para receber um obliterador mecânico especialmente projetado para compatibilizar os parâmetros das técnicas convencionais de deposição com o objetivo de se obter um perfil inclinado, perfil este previsto em processos de simulação para ajustar e calibrar a geometria do obliterador e se obter um filme depositado na espessura, conformação e disposição pretendidos. Ao final destas etapas de modelagem analítica, simulação e refinamento recorrente, foram determinados os parâmetros de projeto para obtenção de um determinado FIV (Filtro de Interferência Variável) especificado. Baseadas nos FIVs muitas aplicações são emergentes: dispositivos multi, hiper e ultra espectral para sensoriamento remoto e análise ambiental, sistemas Lab-on-Chip, biossensores, detectores chip-sized, espectrofotometria de fluorescência on-chip, detectores de deslocamento de comprimento de onda, sistemas de interrogação, sistemas de imageamento espectral, microespectrofotômetros e etc. No escopo deste trabalho se pretende abranger um estudo de uma referência básica do emprego do (FIV) filtro de interferência variável como detector de varredura de comprimento de ondas em sensores biológicos e químicos compatível com pós processamento CMOS. Um sistema básico que é constituído por um FIV montado sobre uma matriz de sensores ópticos conectada a um módulo eletrônico dedicado a medir a intensidade da radiação incidente e as bandas de absorção das moléculas presentes em uma câmara de detecção de um sistema próprio de canais de microfluidos, configurando-se em um sistema de aquisição e armazenamento de dados (DAS), é proposto para demonstrar as possibilidades do FIV e para servir de base para estudos exploratórios das suas diversas potencialidades que, entre tantas, algumas são mencionadas ao longo deste trabalho. O protótipo obtido é capaz de analisar fluidos químicos ou biológicos e pode ser confrontado com os resultados obtidos por equipamentos homologados de uso corrente.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As human populations and resource consumption increase, it is increasingly important to monitor the quality of our environment. While laboratory instruments offer useful information, portable, easy to use sensors would allow environmental analysis to occur on-site, at lower cost, and with minimal operator training. We explore the synthesis, modification, and applications of modified polysiloxane in environmental sensing. Multiple methods of producing modified siloxanes were investigated. Oligomers were formed by using functionalized monomers, producing siloxane materials containing silicon hydride, methyl, and phenyl side chains. Silicon hydride-functionalized oligomers were further modified by hydrosilylation to incorporate methyl ester and naphthyl side chains. Modifications to the siloxane materials were also carried out using post-curing treatments. Methyl ester-functionalized siloxane was incorporated into the surface of a cured poly(dimethylsiloxane) film by siloxane equilibration. The materials containing methyl esters were hydrolyzed to reveal carboxylic acids, which could later be used for covalent protein immobilization. Finally, the siloxane surfaces were modified to incorporate antibodies by covalent, affinity, and adsorption-based attachment. These modifications were characterized by a variety of methods, including contact angle, attenuated total reflectance Fourier transform infrared spectroscopy, dye labels, and 1H nuclear magnetic resonance spectroscopy. The modified siloxane materials were employed in a variety of sensing schemes. Volatile organic compounds were detected using methyl, phenyl, and naphthyl-functionalized materials on a Fabry-Perot interferometer and a refractometer. The Fabry-Perot interferometer was found to detect the analytes upon siloxane extraction by deformation of the Bragg reflectors. The refractometer was used to determine that naphthyl-functionalized siloxanes had elevated refractive indices, rendering these materials more sensitive to some analytes. Antibody-modified siloxanes were used to detect biological analytes through a solid phase microextraction-mediated enzyme linked immunosorbent assay (SPME ELISA). The SPME ELISA was found to have higher analyte sensitivity compared to a conventional ELISA system. The detection scheme was used to detect Escherichia coli at 8500 CFU/mL. These results demonstrate the variety of methods that can be used to modify siloxanes and the wide range of applications of modified siloxanes has been demonstrated through chemical and biological sensing schemes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Notre Europe – Jacques Delors Institute and the European Policy Centre during which experts, including Pascal Lamy, honorary president of Notre Europe – Jacques Delors Institute and former Director of the WTO explored the key issues of the current Transatlantic Trade and Investment Partnership (TTIP) negotiations. What are the geoeconomic and geostrategic goals of the negotiations? What are the rules of the negotiations? Who are the main players? What impact might TTIP have on world trade?

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mitochondrial diseases, predominantly mitochondrial encephalomyopathy, lactic acidosis, and stroke-like episodes (MELAS), may occasionally underlie or coincide with ischemic stroke (IS) in young and middle-aged individuals. We searched for undiagnosed patients with MELAS in a target subpopulation of unselected young IS patients enrolled in the Stroke in Young Fabry Patients study (sifap1). Among the 3291 IS patients aged 18-55 years recruited to the sifap1 study at 47 centers across 14 European countries, we identified potential MELAS patients with the following phenotypic features: (a) diagnosed cardiomyopathy or (b) presence of two of the three following findings: migraine, short stature (≤165 cm for males; ≤155 cm for females), and diabetes. Identified patients' blood samples underwent analysis of the common MELAS mutation, m.3243A>G in the MTTL1 gene of mitochondrial DNA. Clinical and cerebral MRI features of the mutation carriers were reviewed. We analyzed blood samples of 238 patients (177 with cardiomyopathy) leading to identification of four previously unrecognized MELAS main mutation carrier-patients. Their clinical and MRI characteristics were within the expectation for common IS patients except for severe hearing loss in one patient and hyperintensity of the pulvinar thalami on T1-weighted MRI in another one. Genetic testing for the m.3243A>G MELAS mutation in young patients with IS based on phenotypes suggestive of mitochondrial disease identifies previously unrecognized carriers of MELAS main mutation, but does not prove MELAS as the putative cause.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present data publication provides permanent links to original and updated versions of validated data files. The data files include properties of seawater, particulate matter and dissolved matter that were measured from discrete water samples collected with Niskin bottles during the 2009-2013 Tara Oceans expedition. Properties include pigment concentrations from HPLC analysis (10 depths per vertical profile, 25 pigments per depth), the carbonate system (Surface and 400m; pH (total scale), CO2, pCO2, fCO2, HCO3, CO3, Total alkalinity, Total carbon, OmegaAragonite, OmegaCalcite, and dosage Flags), nutrients (10 depths per vertical profile; NO2, PO4, N02/NO3, SI, quality Flags), DOC, CDOM, and dissolved oxygen isotopes. The Service National d'Analyse des Paramètres Océaniques du CO2, at the Université Pierre et Marie Curie, determined CT and AT potentiometrically (Edmond 1970; DOE 1994) on samples preserved according to Dickson et al. (2007). More than 250 vertical profiles of these properties were made across the world ocean. DOC, CDOM and dissolved oxygen isotopes are available only for the Arctic Ocean and Arctic Seas (2013).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

"Les Tomes I et II ont paru en 1900 sous le titre 'Histoire de l'armée d'Italie'."--Catalogue général de la Librairie Française, t.18, 1908.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Imperfect copy: portrait and half-title wanting.