970 resultados para Metabolizable Energy Values
Resumo:
We analyze the neutron skin thickness in finite nuclei with the droplet model and effective nuclear interactions. The ratio of the bulk symmetry energy J to the so-called surface stiffness coefficient Q has in the droplet model a prominent role in driving the size of neutron skins. We present a correlation between the density derivative of the nuclear symmetry energy at saturation and the J/Q ratio. We emphasize the role of the surface widths of the neutron and proton density profiles in the calculation of the neutron skin thickness when one uses realistic mean-field effective interactions. Next, taking as experimental baseline the neutron skin sizes measured in 26 antiprotonic atoms along the mass table, we explore constraints arising from neutron skins on the value of the J/Q ratio. The results favor a relatively soft symmetry energy at subsaturation densities. Our predictions are compared with the recent constraints derived from other experimental observables. Though the various extractions predict different ranges of values, one finds a narrow window L∼45-75 MeV for the coefficient L that characterizes the density derivative of the symmetry energy that is compatible with all the different empirical indications.
Resumo:
Anthropogenic disturbance of wildlife is of growing conservation concern, but we lack comprehensive approaches of its multiple negative effects. We investigated several effects of disturbance by winter outdoor sports on free-ranging alpine Black Grouse by simultaneously measuring their physiological and behavioral responses. We experimentally flushed radio-tagged Black Grouse from their snow burrows, once a day, during several successive days, and quantified their stress hormone levels (corticosterone metabolites in feces [FCM] collected from individual snow burrows). We also measured feeding time allocation (activity budgets reconstructed from radio-emitted signals) in response to anthropogenic disturbance. Finally, we estimated the related extra energy expenditure that may be incurred: based on activity budgets, energy expenditure was modeled from measures of metabolism obtained from captive birds subjected to different ambient temperatures. The pattern of FCM excretion indicated the existence of a funneling effect as predicted by the allostatic theory of stress: initial stress hormone concentrations showed a wide inter-individual variation, which decreased during experimental flushing. Individuals with low initial pre-flushing FCM values augmented their concentration, while individuals with high initial FCM values lowered it. Experimental disturbance resulted in an extension of feeding duration during the following evening foraging bout, confirming the prediction that Black Grouse must compensate for the extra energy expenditure elicited by human disturbance. Birds with low initial baseline FCM concentrations were those that spent more time foraging. These FCM excretion and foraging patterns suggest that birds with high initial FCM concentrations might have been experiencing a situation of allostatic overload. The energetic model provides quantitative estimates of extra energy expenditure. A longer exposure to ambient temperatures outside the shelter of snow burrows, following disturbance, could increase the daily energy expenditure by >10%, depending principally on ambient temperature and duration of exposure. This study confirms the predictions of allostatic theory and, to the best of our knowledge, constitutes the first demonstration of a funneling effect. It further establishes that winter recreation activities incur costly allostatic behavioral and energetic adjustments, which call for the creation of winter refuge areas together with the implementation of visitor-steering measures for sensitive wildlife.
Resumo:
This thesis analyses the calculation of FanSave and PumpSave energy saving tools calculation. With these programs energy consumption of variable speed drive control for fans and pumps can be compared to other control methods. With FanSave centrifugal and axial fans can be examined and PumpSave deals with centrifugal pumps. By means of these programs also suitable frequency converter can be chosen from the ABB collection. Programs need as initial values information about the appliances like amount of flow and efficiencies. Operation time is important factor when calculating the annual energy consumption and information about it are the length and profile. Basic theory related to fans and pumps is introduced without more precise instructions for dimensioning. FanSave and PumpSave contain various methods for flow control. These control methods are introduced in the thesis based on their operational principles and suitability. Also squirrel cage motor and frequency converter are introduced because of their close involvement to fans and pumps. Second part of the thesis contains comparison between results of FanSave’s and PumpSave’s calculation and performance curve based calculation. Also laboratory tests were made with centrifugal and axial fan and also with centrifugal pump. With the results from this thesis the calculation of these programs can be adjusted to be more accurate and also some new features can be added.
Resumo:
BACKGROUND & AIMS: Protein and energy requirements in critically ill children are currently based on insufficient data. Moreover, longitudinal measurements of both total urinary nitrogen (TUN) and resting energy expenditure (REE) are lacking. The aim of this study was to investigate how much protein and energy are needed to equilibrate nitrogen and energy balances in ventilated critically ill children on the basis of daily measurements of TUN, REE and protein and energy intakes. Comparisons were made with the guidelines of the American Society for Parenteral and Enteral Nutrition and the Dietary Reference Intakes. METHODS: Children with an expected duration of mechanical ventilation ≥72 h were prospectively recruited. TUN was measured by chemiluminescence, and REE was measured by indirect calorimetry. Generalised linear models for longitudinal data were used to study the relation between protein intake and nitrogen balance and to calculate the minimum intake of protein needed to achieve nitrogen equilibrium. A similar approach was used for energy. Results were compared to the recommended values. RESULTS: Based on 402 measurements performed in 74 children (median age: 21 months), the mean TUN was high at 0.20 (95% CI: 0.20, 0.22) g/kg/d and the REE was 55 (95% CI: 54, 57) kcal/kg/d. Nitrogen and energy balances were achieved with 1.5 (95% CI: 1.4, 1.6) g/kg/d of protein and 58 (95% CI: 53, 63) kcal/kg/d for the entire group, but there were differences among children of different ages. Children required more protein and less energy than the Dietary Reference Intakes. CONCLUSIONS: In critically ill children, TUN was elevated and REE was reduced during the entire period of mechanical ventilation. Minimum intakes of 1.5 g/kg/d of protein and 58 kcal/kg/d can equilibrate nitrogen and energy balances in children up to 4 years old. Older children require more protein.
Resumo:
A thorough critical analysis of the theoretical relationships between the bond-angle dispersion in a-Si, Δθ, and the width of the transverse optical Raman peak, Γ, is presented. It is shown that the discrepancies between them are drastically reduced when unified definitions for Δθ and Γ are used. This reduced dispersion in the predicted values of Δθ together with the broad agreement with the scarce direct determinations of Δθ is then used to analyze the strain energy in partially relaxed pure a-Si. It is concluded that defect annihilation does not contribute appreciably to the reduction of the a-Si energy during structural relaxation. In contrast, it can account for half of the crystallization energy, which can be as low as 7 kJ/mol in defect-free a-Si
Resumo:
The promotion of energy-efficient appliances is necessary to reduce the energetic and environmental burden of the household sector. However, many studies have reported that a typical consumer underestimates the benefits of energy-saving investment on the purchase of household electric appliances. To analyze this energy-efficiency gap problem, many scholars have estimated implicit discount rates that consumers use for energy-consuming durables. Although both hedonic and choice models have been used in previous studies, a comparison between two models has not yet been done. This study uses point of sale data about Japanese residential air conditioners and estimates implicit discounts rates with both hedonic and choice models. Both models demonstrate that a typical consumer underinvests in energy efficiency. Although choice models estimate a lower implicit discount rate than hedonic models, the latter models estimate the values of other product characteristics more consistently than choice models.
Resumo:
Friedelin molecular conformers were obtained by Density Functional Theory (DFT) and by ab initio structure determination from powder X-ray diffraction. Their conformers with the five rings in chair-chair-chair-boat-boat, and with all rings in chair, are energy degenerated in gas-phase according to DFT results. The powder diffraction data reveals that rings A, B and C of friedelin are in chair, and rings D and E in boat-boat, conformation. The high correlation values among powder diffraction data, DFT and reported single-crystal data indicate that the use of conventional X-ray diffractometer can be applied in routine laboratory analysis in the absence of a single-crystal diffractometer.
Resumo:
ABSTRACTThe objective of this study was to determine the energy balance of the poultry-shed system and its effect on broiler performance during the production cycle. The experimental design was completely random with sub-divided blocks. The blocks were composed of five different types of sheds and the sub-blocks of the evaluation times (00:00 h to 23:00 h), allowing an analysis of variance and a comparison between means with the Tukey test. There were no significant differences between the mean values of the exchanges of sensible, latent and total heat between the poultry sheds but the differences for the evaluation times were significant (P<0.05). There was no significant difference between sheds 1 and 4 for broiler productive performance regarding weight gain, feed consumption and feed conversion. Bird performance was significant (P<0.05) for the remaining poultry sheds. The productive indexes remained below the ranges considered ideal for broilers and values in the final weeks were characterized by the poor installation efficiency in controlling temperature variations and, consequently, the energy balance in the system, which adversely affected bird productive performance.
Resumo:
In early lactation dairy cattle suffer metabolic alterations caused by negative energy balance, which predisposes to fatty liver and ketosis. The aim of this study was to evaluate the metabolic condition of high yielding dairy cows subjected to three treatments for preventing severe lipomobilization and ketosis in early lactation. Fifty four multiparous Holstein cows yielding >30 L/day were divided into four groups: control (CN= no treatment), glucose precursor (PG= propylene-glycol), hepatic protector (Mp= Mercepton®), and energy supplement with salts of linolenic and linoleic faty acids (Mg-E= Megalac-E®). Treatments were administrated randomly at moment of calving until 8 weeks postpartum. Blood samples were collected on days 1, 7, 14, 21, 28, 35, 42 and 49 postpartum. Body condition score (BCS) was evaluated at the same periods and milk yield was recorded at 2nd, 4th, 5th, 6th, 7th, and 8th weeks of lactation. Concentrations of non-esterified fatty acids (NEFA), albumin, AST, ß-hydroxybutyrate (BHBA), cholesterol, glucose, total protein, urea and triglycerides were analyzed in blood samples. Cut-off points for subclinical ketosis were defined when BHBA >1.4 mmol/L and NEFA >0.7 mmol/L. General occurrence of subclinical ketosis was 24% during the period. An ascendant curve of cholesterol and glucose was observed from the 1st to the 8th week of lactation, while any tendency was observed with BHBA and NEFA, although differences among treatments were detected (p<0.05). BCS decreased from a mean of 3.85 at 1st week to 2.53 at 8th week of lactation (p=0.001). Milk yield was higher in the Mg-E group compared with the other treatment groups (p<0.05) Compared with the CN group, the treatments with Mp and PG did not show significant differences in blood biochemistry and milk yield. Cows receiving PG and Mg-E showed higher values of BHBA and NEFA (P<0.05), indicating accentuated lipomobilization. Supplementation with Mg-E also resulted in significant higher concentrations of cholesterol, BHBA, urea, AST and lower values of glycemia. This performance may be explained by the highest milk yield observed with this treatment. Treatments with PG and Mp did not improve milk yield, compared with control cows, but did not show metabolic evidence of ketosis, fat mobilization or fatty liver. These results suggest that treatment with Mg-E improves milk production but induces a higher negative energy balance leading to moderated lipomobilization and ketone bodies production, increasing the risk of fatty liver.
Resumo:
The stabilizing free energy of ß-trypsin was determined by hydrogen ion titration. In the pH range from 3.0 to 7.0, the change in free energy difference for the stabilization of the native protein relative to the unfolded one (D D G0 titration) was 9.51 ± 0.06 kcal/mol. An isoelectric point of 10.0 was determined, allowing us to calculate the Tanford and Kirkwood electrostatic factor w. This factor presented a nonlinear behavior and indicated more than one type of titratable carboxyl groups in ß-trypsin. In fact, one class of carboxyl group with a pK = 3.91 ± 0.01 and another one with a pK = 4.63 ± 0.03 were also found by hydrogen ion titration of the protein in the folded state
Resumo:
The aim of this study was to measure the energy expenditure for locomotor activities usually performed by soccer referees during a match (walking, jogging, and running) under laboratory conditions, and to compare forward with backward movements. The sample was composed by 10 male soccer referees, age 29±7.8 years, body mass 77.5±6.2 kg, stature 1.78±0.07 m and professional experience of 7.33±4.92 years. Referees were evaluated on two separate occasions. On the first day, maximal oxygen uptake (VO2max) was determined by a maximal treadmill test, and on the second day, the oxygen consumption was determined in different speeds of forward and backward movements. The mean VO2max was 41.20±3.60 mL·kg-1·min-1 and the mean heart rate achieved in the last stage of the test was 190.5±7.9 bpm. When results of forward and backward movements were compared at 1.62 m/s (walking speed), we found significant differences in VO2, in metabolic equivalents, and in kcal. However, the same parameters in forward and backward movements at jogging velocities (2.46 m/s) were not significantly different, showing that these motor activities have similar intensity. Backward movements at velocities equivalent to walking and jogging are moderate-intensity activities, with energy expenditure less than 9 kcal. Energy expenditure was overestimated by at least 35% when calculated by mathematical equations. In summary, we observed that backward movements are not high-intensity activities as has been commonly reported, and when calculated using equations available in the literature, energy expenditure was overestimated compared to the values obtained by indirect calorimetry.
Resumo:
Celery (Apium graveolens L. var. secalinum Alef) leaves with 50±0.07 g weight and 91.75±0.15% humidity (~11.21 db) were dried using 8 different microwave power densities ranging between 1.8-20 W g-1, until the humidity fell down to 8.95±0.23% (~0.1 db). Microwave drying processes were completed between 5.5 and 77 min depending on the microwave power densities. In this study, measured values were compared with predicted values obtained from twenty thin layer drying theoretical, semi-empirical and empirical equations with a new thin layer drying equation. Within applied microwave power density; models whose coefficient and correlation (R²) values are highest were chosen as the best models. Weibull distribution model gave the most suitable predictions at all power density. At increasing microwave power densities, the effective moisture diffusivity values ranged from 1.595 10-10 to 6.377 10-12 m2 s-1. The activation energy was calculated using an exponential expression based on Arrhenius equation. The linear relationship between the drying rate constant and effective moisture diffusivity gave the best fit.
Resumo:
Abstract The present study aimed at investigating the influences of drying air temperature and flow rate on energy parameters and dehydration behaviour of apple slices. For this purpose, apple slices were dried in a convective dryer at air temperatures of 50, 60 and 70 °C, and air velocities of 1, 1.5 and 2 m s–1. Dehydration rate increased as the air temperature and flow rate increased from 50 to 70 °C and 1 to 2 m s–1, respectively. The effective moisture diffusivity was determined to be in the range of 6.75×10–10-1.28×10–9 m2 s–1. Results of data analysis showed that the maximum energy consumption (23.94 kW h) belonged to 50 °C and 2 m s–1 and the minimum (13.89 kW h) belonged to 70 °C and 1 m s–1 treatment. Energy efficiency values were in the range of 2.87-9.11%. Moreover, the results indicated that any increment in the air temperature increases thermal and drying efficiencies while any increment in the air flow rate decreases both of them.
Resumo:
The main objective of this thesis is to evaluate the economic and environmental effectiveness of three different renewable energy systems: solar PV, wind energy and biomass energy systems. Financial methods such as Internal Rate of Return (IRR) and Modified Internal Rate of Return (MIRR) were used to evaluate economic competitiveness. Seasonal variability in power generation capability of different renewable systems were also taken into consideration. In order to evaluate the environmental effectiveness of different energy systems, default values in GaBi software were taken by defining the functional unit as 1kWh. The results show that solar PV systems are difficult to justify both in economic as well as environmental grounds. Wind energy performs better in both economic and environmental grounds and has the capability to compete with conventional energy systems. Biomass energy systems exhibit environmental and economic performance at the middle level. In each of these systems, results vary.
Resumo:
This thesis reviews the role of nuclear and conventional power plants in the future energy system. The review is done by utilizing freely accesible publications in addition to generating load duration and ramping curves for Nordic energy system. As the aim of the future energy system is to reduce GHG-emissions and avoid further global warming, the need for flexible power generation increases with the increased share of intermittent renewables. The goal of this thesis is to offer extensive understanding of possibilities and restrictions that nuclear power and conventional power plants have regarding flexible and sustainable generation. As a conclusion, nuclear power is the only technology that is able to provide large scale GHG-free power output variations with good ramping values. Most of the currently operating plants are able to take part in load following as the requirement to do so is already required to be included in the plant design. Load duration and ramping curves produced prove that nuclear power is able to cover most of the annual generation variation and ramping needs in the Nordic energy system. From the conventional power generation methods, only biomass combustion can be considered GHG-free because biomass is considered carbon neutral. CFB combusted biomass has good load follow capabilities in good ramping and turndown ratios. All the other conventional power generation technologies generate GHG-emissions and therefore the use of these technologies should be reduced.