1000 resultados para Medical microscopy.
Resumo:
We explore the determinants of usage of six different types of health care services, using the Medical Expenditure Panel Survey data, years 1996-2000. We apply a number of models for univariate count data, including semiparametric, semi-nonparametric and finite mixture models. We find that the complexity of the model that is required to fit the data well depends upon the way in which the data is pooled across sexes and over time, and upon the characteristics of the usage measure. Pooling across time and sexes is almost always favored, but when more heterogeneous data is pooled it is often the case that a more complex statistical model is required.
Resumo:
We review recent likelihood-based approaches to modeling demand for medical care. A semi-nonparametric model along the lines of Cameron and Johansson's Poisson polynomial model, but using a negative binomial baseline model, is introduced. We apply these models, as well a semiparametric Poisson, hurdle semiparametric Poisson, and finite mixtures of negative binomial models to six measures of health care usage taken from the Medical Expenditure Panel survey. We conclude that most of the models lead to statistically similar results, both in terms of information criteria and conditional and unconditional prediction. This suggests that applied researchers may not need to be overly concerned with the choice of which of these models they use to analyze data on health care demand.
Resumo:
We study the optimal public intervention in setting minimum standards of formation for specialized medical care. The abilities the physicians obtain by means of their training allow them to improve their performance as providers of cure and earn some monopoly rents.. Our aim is to characterize the most efficient regulation in this field taking into account different regulatory frameworks. We find that the existing situation in some countries, in which the amount of specialization is controlled, and the costs of this process of specialization are publicly financed, can be supported as the best possible intervention.
Resumo:
Miniature light traps used to collect Phlebotominae in a focus of dermal leishmaniasis in the eastern part of the State of Minas Gerais, Brazil. Over a period of seven months, the other Diptera captured in 179 light trap samples were identified to family level. The traps were placed in eight localities which constituted three different biotopes: three woodland aresas, cultivated land, and a peridomestic site. A comparison is made between the totals of Dipeterans collected in each biotope, the total numbers of families collected in each biotope and the estimated indices of diversity. Dendograms representing the degrees of association between families of Diptera in different biotopes are presented. Some families of Diptera are uniformly distributed throughout the study area; a few families seem to have become adapted to areas where human activity has induced the greatest ecological changes. The impact between Dipterans and human well-being is discussed. The availabel evidence indicates that transmission of dermal leishmaniasis does not occur in areas where sand flies can be captured in greatest densities.
Resumo:
Detection of rotavirus RNA by polyacrylamide gel electrophoresis (PAGE) proved to be a highly sensitive and rapid diagnostic test. A comparison of this assay with immuno-electron microscopy (IEM) and enzyme immunoassay (EIA) in 245 faeces from children with gastroenteritis revealed complete agreement between the three assays in 238 (97.14%) samples. Among 75 samples positive in at least one of the three assays, negative results were observed in 5 (6.48%) by PAGE, in 6 (6.76%) by EIA and in none by IEM. Silver staining greatly increased the sensitivity of the PAGE assay. We conclude that although IEM remains the most sensitive and rapid rotavirus diagnostic assay, the PAGE technique has many advantages in its favour, including the non-requirement of expensive equipment, the use of only chemically defined reagents and the capacity to distinguish virus subgroup and variants and to detect non-crossreactive rotaviruses which are missed in serological assays.
Resumo:
Cancer is a major burden in today's society and one of the leading causes of death in industrialised countries. Various avenues for the detection of cancer exist, most of which rely on standard methods, such as histology, ELISA, and PCR. Here we put the focus on nanomechanical biosensors derived from atomic force microscopy cantilevers. The versatility of this novel technology has been demonstrated in different applications and in some ways surpasses current technologies, such as microarray, quartz crystal microbalance and surface plasmon resonance. The technology enables label free biomarker detection without the necessity of target amplification in a total cellular background, such as BRAF mutation analysis in malignant melanoma. A unique application of the cantilever array format is the analysis of conformational dynamics of membrane proteins associated to surface stress changes. Another development is characterisation of exhaled breath which allows assessment of a patient's condition in a non-invasive manner.
Resumo:
Transmission electon microscopy has been employed for the rapid detection of mycoplasma in sera and cell cultures. High speed centrifugation of sera or low speed centrifugation of cell debris, followed by negative staining of the resuspended pellet, detected mycoplasma contamination more frequently than a culture method followed by direct fluorescence (DAPI), which was used as a control procedure. The appearance of the mycoplasma cell border and content gives some information about particle viability.
Resumo:
The egg and the first instar larva of Dermatobia hominis were described based on observation with a scanning electron microscope.
Resumo:
Comparision by scanning electron microscopy (SEM) of Trypanosoma cruzi flagellates attached to the cuticle of the rectal gland of infected Dipetalogaster maxima nymphs, showed marked differences before amd after feeding. Before feeding numerous metacyclic trypomastigotes were observed among the abundant epimastigotes that formed the carpet of flagellates. On the other hand, in insects that were allowed to urinate for 24 hours after a meal, the metacyclics were scarce,indicating that they had been detached by the urine flow. An asymetric type of cell division, probably originating both an epi-and a trypomastigote, was occasionally observed. The occurrence of swellings at different levels of the flagella of epimastigotes suggests that secondary sites of attachment may be common.
Resumo:
BACKGROUND/OBJECTIVES: This study aims to assess whether patent foramen ovale (PFO) closure is superior to medical therapy in preventing recurrence of cryptogenic ischemic stroke or transient ischemic attack (TIA). METHODS: We searched PubMed for randomized trials which compared PFO closure with medical therapy in cryptogenic stroke/TIA using the items: "stroke or cerebrovascular accident or TIA" and "patent foramen ovale or paradoxical embolism" and "trial or study". RESULTS: Among 650 potentially eligible articles, 3 were included including 2303 patients. There was no statistically significant difference between PFO-closure and medical therapy in ischemic stroke recurrence (1.91% vs. 2.94% respectively, OR: 0.64, 95%CI: 0.37-1.10), TIA (2.08% vs. 2.42% respectively, OR: 0.87, 95%CI: 0.50-1.51) and death (0.60% vs. 0.86% respectively, OR: 0.71, 95%CI: 0.28-1.82). In subgroup analysis, there was significant reduction of ischemic strokes in the AMPLATZER PFO Occluder arm vs. medical therapy (1.4% vs. 3.04% respectively, OR: 0.46, 95%CI: 0.21-0.98, relative-risk-reduction: 53.2%, absolute-risk-reduction: 1.6%, number-needed-to-treat: 61.8) but not in the STARFlex device (2.7% vs. 2.8% with medical therapy, OR: 0.93, 95%CI: 0.45-2.11). Compared to medical therapy, the number of patients with new-onset atrial fibrillation (AF) was similar in the AMPLATZER PFO Occluder arm (0.72% vs. 1.28% respectively, OR: 1.81, 95%CI: 0.60-5.42) but higher in the STARFlex device (0.64% vs. 5.14% respectively, OR: 8.30, 95%CI: 2.47-27.84). CONCLUSIONS: This meta-analysis does not support PFO closure for secondary prevention with unselected devices in cryptogenic stroke/TIA. In subgroup analysis, selected closure devices may be superior to medical therapy without increasing the risk of new-onset AF, however. This observation should be confirmed in further trials using inclusion criteria for patients with high likelihood of PFO-related stroke recurrence.