999 resultados para Mass parameter
Resumo:
We present a two-Higgs-doublet model, with a Z(3) symmetry, in which CP violation originates solely in a soft (dimension-2) coupling in the scalar potential, and reveals itself solely in the CKM (quark mixing) matrix. In particular, in the mass basis the Yukawa interactions of the neutral scalars are all real. The model has only eleven parameters to fit the six quark masses and the four independent CKM-matrix observables. We find regions of parameter space in which the flavour-changing neutral couplings are so suppressed that they allow the scalars to be no heavier than a few hundred GeV. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
The development of accurate mass spectrometry, enabling the identification of all the ions extracted from the ion source in a high current implanter is described. The spectrometry system uses two signals (x-y graphic), one proportional to the magnetic field (x-axes), taken from the high-voltage potential with an optic fiber system, and the other proportional to the beam current intensity (y-axes), taken from a beam-stop. The ion beam mass register in a mass spectrum of all the elements magnetically analyzed with the same radius and defined by a pair of analyzing slits as a function of their beam intensity is presented. The developed system uses a PC to control the displaying of the extracted beam mass spectrum, and also recording of all data acquired for posterior analysis. The operator uses a LabView code that enables the interfacing between an I/O board and the ion implanter. The experimental results from an ion implantation experiment are shown. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
OBJECTIVO: Analisar a influência da Idade nos efeitos de um Programa de Reabilitação Cardíaca Fase III, em pacientes coronários, analisando Provas de Esforço. METODOLOGIA: Amostra constituída pelo Grupo Meia-idade, <65 anos, e Grupo Idosos, ≥65 anos, tendo sido recolhidos o Índice de Massa Corporal, Velocidade e Inclinação máximas, Tempo de Prova, VO2 máximo teórico, Tensão Arterial basal, máxima e de recuperação, Frequência Cardíaca máxima, Percentagem da Frequência Cardíaca máxima teórica, Duplo Produto máximo e Tempo de Recuperação. RESULTADOS: Sem diferenças significativas, entre os dois grupos, em nenhum parâmetro. CONCLUSÕES: A Idade não influenciou os efeitos do Programa de Reabilitação Cardíaca.
Resumo:
Lisbon is the largest urban area in the Western European coast. Due to this geographical position the Atlantic Ocean serves as an important source of particles and plays an important role in many atmospheric processes. The main objectives of this study were to (1) perform a chemical characterization of particulate matter (PM2.5) sampled in Lisbon, (2) identify the main sources of particles, (3) determine PM contribution to this urban area, and (4) assess the impact of maritime air mass trajectories on concentration and composition of respirable PM sampled in Lisbon. During 2007, PM2.5 was collected on a daily basis in the center of Lisbon with a Partisol sampler. The exposed Teflon filters were measured by gravimetry and cut into two parts: one for analysis by instrumental neutron activation analysis (INAA) and the other by ion chromatography (IC). Principal component analysis (PCA) and multilinear regression analysis (MLRA) were used to identify possible sources of PM2.5 and determine mass contribution. Five main groups of sources were identified: secondary aerosols, traffic, calcium, soil, and sea. Four-day backtracking trajectories ending in Lisbon at the starting sampling time were calculated using the HYSPLIT model. Results showed that maritime transport scenarios were frequent. These episodes were characterized by a significant decrease of anthropogenic aerosol concentrations and exerted a significant role on air quality in this urban area.
Resumo:
The scheduling problem is considered in complexity theory as a NP-hard combinatorial optimization problem. Meta-heuristics proved to be very useful in the resolution of this class of problems. However, these techniques require parameter tuning which is a very hard task to perform. A Case-based Reasoning module is proposed in order to solve the parameter tuning problem in a Multi-Agent Scheduling System. A computational study is performed in order to evaluate the proposed CBR module performance.
Resumo:
The analysis of the Higgs boson data by the ATLAS and CMS Collaborations appears to exhibit an excess of h -> gamma gamma events above the Standard Model (SM) expectations, whereas no significant excess is observed in h -> ZZ* -> four lepton events, albeit with large statistical uncertainty due to the small data sample. These results (assuming they persist with further data) could be explained by a pair of nearly mass-degenerate scalars, one of which is an SM-like Higgs boson and the other is a scalar with suppressed couplings to W+W- and ZZ. In the two-Higgs-doublet model, the observed gamma gamma and ZZ* -> four lepton data can be reproduced by an approximately degenerate CP-even (h) and CP-odd (A) Higgs boson for values of sin (beta - alpha) near unity and 0: 70 less than or similar to tan beta less than or similar to 1. An enhanced gamma gamma signal can also arise in cases where m(h) similar or equal to m(H), m(H) similar or equal to m(A), or m(h) similar or equal to m(H) similar or equal to m(A). Since the ZZ* -> 4 leptons signal derives primarily from an SM-like Higgs boson whereas the gamma gamma signal receives contributions from two (or more) nearly mass-degenerate states, one would expect a slightly different invariant mass peak in the ZZ* -> four lepton and gamma gamma channels. The phenomenological consequences of such models can be tested with additional Higgs data that will be collected at the LHC in the near future. DOI: 10.1103/PhysRevD.87.055009.
Resumo:
We present the first version of a new tool to scan the parameter space of generic scalar potentials, SCANNERS (Coimbra et al., SCANNERS project., 2013). The main goal of SCANNERS is to help distinguish between different patterns of symmetry breaking for each scalar potential. In this work we use it to investigate the possibility of excluding regions of the phase diagram of several versions of a complex singlet extension of the Standard Model, with future LHC results. We find that if another scalar is found, one can exclude a phase with a dark matter candidate in definite regions of the parameter space, while predicting whether a third scalar to be found must be lighter or heavier. The first version of the code is publicly available and contains various generic core routines for tree level vacuum stability analysis, as well as implementations of collider bounds, dark matter constraints, electroweak precision constraints and tree level unitarity.
Resumo:
A multiresidue gas chromatographic method for the determination of six fungicides (captan, chlorthalonil, folpet, iprodione, procymidone and vinclozolin) and one acaricide (dicofol) in still and fortified wines was developed. Solid-phase microextraction (SPME) was chosen for the extraction of the compounds from the studied matrices and tandem mass spectrometry (MS/MS) detection was used. The extraction consists in a solvent free and automated procedure and the detection is highly sensitive and selective. Good linearity was obtained with correlation coefficients of regression (R2) > 0.99 for all the compounds. Satisfactory results of repeatability and intermediate precision were obtained for most of the analytes (RSD < 20%). Recoveries from spiked wine ranged from 80.1% to 112.0%. Limits of quantification (LOQs) were considerably below the proposedmaximumresidue limits (MRLs) for these compounds in grapes and below the suggested limits for wine (MRLs/10), with the exception of captan.
Resumo:
We have developed a new method for single-drop microextraction (SDME) for the preconcentration of organochlorine pesticides (OCP) from complex matrices. It is based on the use of a silicone ring at the tip of the syringe. A 5 μL drop of n-hexane is applied to an aqueous extract containing the OCP and found to be adequate to preconcentrate the OCPs prior to analysis by GC in combination with tandem mass spectrometry. Fourteen OCP were determined using this technique in combination with programmable temperature vaporization. It is shown to have many advantages over traditional split/splitless injection. The effects of kind of organic solvent, exposure time, agitation and organic drop volume were optimized. Relative recoveries range from 59 to 117 %, with repeatabilities of <15 % (coefficient of variation) were achieved. The limits of detection range from 0.002 to 0.150 μg kg−1. The method was applied to the preconcentration of OCPs in fresh strawberry, strawberry jam, and soil.
Resumo:
Multiclass analysis method was optimized in order to analyze pesticides traces by gas chromatography with ion-trap and tandem mass spectrometry (GC-MS/MS). The influence of some analytical parameters on pesticide signal response was explored. Five ion trap mass spectrometry (IT-MS) operating parameters, including isolation time (IT), excitation voltage (EV), excitation time (ET),maximum excitation energy or “q” value (q), and isolationmass window (IMW) were numerically tested in order to maximize the instrument analytical signal response. For this, multiple linear regression was used in data analysis to evaluate the influence of the five parameters on the analytical response in the ion trap mass spectrometer and to predict its response. The assessment of the five parameters based on the regression equations substantially increased the sensitivity of IT-MS/MS in the MS/MS mode. The results obtained show that for most of the pesticides, these parameters have a strong influence on both signal response and detection limit.Using the optimized method, a multiclass pesticide analysis was performed for 46 pesticides in a strawberry matrix. Levels higher than the limit established for strawberries by the European Union were found in some samples.
Resumo:
The species abundance distribution (SAD) has been a central focus of community ecology for over fifty years, and is currently the subject of widespread renewed interest. The gambin model has recently been proposed as a model that provides a superior fit to commonly preferred SAD models. It has also been argued that the model's single parameter (α) presents a potentially informative ecological diversity metric, because it summarises the shape of the SAD in a single number. Despite this potential, few empirical tests of the model have been undertaken, perhaps because the necessary methods and software for fitting the model have not existed. Here, we derive a maximum likelihood method to fit the model, and use it to undertake a comprehensive comparative analysis of the fit of the gambin model. The functions and computational code to fit the model are incorporated in a newly developed free-to-download R package (gambin). We test the gambin model using a variety of datasets and compare the fit of the gambin model to fits obtained using the Poisson lognormal, logseries and zero-sum multinomial distributions. We found that gambin almost universally provided a better fit to the data and that the fit was consistent for a variety of sample grain sizes. We demonstrate how α can be used to differentiate intelligibly between community structures of Azorean arthropods sampled in different land use types. We conclude that gambin presents a flexible model capable of fitting a wide variety of observed SAD data, while providing a useful index of SAD form in its single fitted parameter. As such, gambin has wide potential applicability in the study of SADs, and ecology more generally.
Resumo:
Objective - To evaluate the effect of prepregnancy body mass index (BMI), energy and macronutrient intakes during pregnancy, and gestational weight gain (GWG) on the body composition of full-term appropriate-for-gestational age neonates. Study Design - This is a cross-sectional study of a systematically recruited convenience sample of mother-infant pairs. Food intake during pregnancy was assessed by food frequency questionnaire and its nutritional value by the Food Processor Plus (ESHA Research Inc, Salem, OR). Neonatal body composition was assessed both by anthropometry and air displacement plethysmography. Explanatory models for neonatal body composition were tested by multiple linear regression analysis. Results - A total of 100 mother-infant pairs were included. Prepregnancy overweight was positively associated with offspring weight, weight/length, BMI, and fat-free mass in the whole sample; in males, it was also positively associated with midarm circumference, ponderal index, and fat mass. Higher energy intake from carbohydrate was positively associated with midarm circumference and weight/length in the whole sample. Higher GWG was positively associated with weight, length, and midarm circumference in females. Conclusion - Positive adjusted associations were found between both prepregnancy BMI and energy intake from carbohydrate and offspring body size in the whole sample. Positive adjusted associations were also found between prepregnancy overweight and adiposity in males, and between GWG and body size in females.
Resumo:
O presente trabalho experimental teve como objectivos estudar a tratabilidade dum efluente lácteo utilizando a técnica de coagulação/floculação e avaliar a possibilidade de utilização do carvão activado granulado (CAG) Aquasorb 2000 como adsorvente para a remoção de compostos orgânicos presentes nos efluentes lácteos pré–tratados por coagulação/floculação, funcionando como um tratamento de polimento. No estudo da tratabilidade do efluente por coagulação/floculação investigou-se a influência de determinadas variáveis como o tipo e dose de coagulante e pH, a fim de encontrar as melhores condições operatórias. A utilização da referida técnica visou a redução do valor de concentração de alguns parâmetros: carência química de oxigénio (CQO); fósforo total e turvação, tendo sido utilizados efluentes desta indústria recolhidos em diferentes datas e após tratamento biológico, designados por A, B, C e D apresentando características diferentes. Sendo que o efluente A apresentava valores de CQO, fósforo total e turvação de 500 mg O2/L;32 mg P/L e 40 NTU respectivamente, o efluente B 1400 mg O2/L; 120 mg P/L e 80 NTU respectivamente, o efluente C 12300 mg O2/L; 87 mg P/L e 350 NTU respectivamente e o efluente D 340 mg O2/L; 33 mg P/L e 42 NTU respectivamente. Os coagulantes estudados foram hidróxido de cálcio (HC), sulfato de alumínio (SA) e tricloreto de ferro (TF). Verificou-se que o coagulante com maior eficácia nos efluentes estudados foi o TF. As maiores remoções de CQO, fósforo total e turvação, 89%, 99,9% e 99%, respectivamente, foram obtidas para o efluente C, com uma dosagem de TF de 4 g/L e com um pH entre 6 e 7. Entre os efluentes estudados este era o que apresentava valores iniciais mais elevados para qualquer um destes parâmetros. As melhores percentagens de remoção obtidas com o HC, para a CQO, fósforo total e turvação foram de 59%, 99% e 91%, respectivamente, com uma dosagem de HC de 1 g/L e com um pH entre 10 e 11,5 foram conseguidas no tratamento do efluente D, com o qual se alcançaram também as melhores remoções de CQO, fósforo total e turvação de 65%, 99% e 87%, respectivamente, quando se utilizou o coagulante SA, com uma dosagem de 2 g/L e com um pH entre 7 e 7,5. Relativamente ao volume de lamas produzido neste processo pela utilização dos diferentes coagulantes no tratamento dos efluentes referidos concluiu-se que o coagulante que gera menor volume de lamas é o HC, sendo o SA aquele que origina um maior volume. Submeteu-se posteriormente o efluente D, pré-tratado por coagulação/floculação, a um processo de adsorção em batch utilizando o CAG Aquasorb 2000, onde se conseguiu uma remoção de CQO de 48%, alcançando para este parâmetro o valor de 63 mg O2/L, nas condições operatórias que correspondem a uma massa de CAG de 12,5 g/L e um tempo de contacto de 3 horas. Quanto aos custos associados com os coagulantes, o que menores custos apresenta é o HC (150 €/ton), seguido pelo TF (250 €/ton) e por ultimo o SA (340 €/ton). Sendo que o efluente quando tratado com TF e SA é necessário uma correcção do pH do meio para que estes coagulantes actuem eficazmente, em que essa correcção de pH é realizada com hidróxido de sódio (540 €/ton). Realizaram-se ainda estudos de equilíbrio de adsorção com o carvão activado referido e o azul-de-metileno usando diferentes concentrações deste (50 mg/L; 100 mg/L e 200 mg/L) e diferentes massas de CAG (0,1g; 0,2g; 0,3g; 0,4g e 0,5g). A temperatura a que se realizaram estes ensaios foi de 28,7ºC e o volume de azul-de-metileno foi de 200 mL. Verificou-se que os melhores resultados obtidos foram para uma concentração de adsorvato de 100 mg/L. Ajustaram-se os modelos de Langmuir e Freundlich às isotérmicas obtidas tendo correlações mais elevadas para a concentração de 100 mg/L de corante (azul de metileno), sendo o modelo de Freundlich aquele que melhor se ajustou apresentando uma correlação quadrática de 0,9744 e os seguintes parâmetros Kf = 6,59 e n = 5,33, enquanto que o de Langmuir apresentou uma correlação quadrática de 0,9583 e os seguintes parâmetros qmáx = 83,3 mg/g de adsorvente e K = 20 L/mg de adsorvato.. Verificou-se que a capacidade de adsorção promovida pelo CAG, em relação ao azul-demetileno, obtida experimentalmente, 83,3 mg/g, é muito inferior à capacidade de adsorção teoricamente prevista pela ficha técnica deste carvão, 280 mg/g a uma temperatura de 25ºC, o que pode indiciar que o carvão utilizado não estaria nas melhores condições.
Resumo:
OBJECTIVE: To determine the best cut-offs of body mass index for identifying alterations of blood lipids and glucose in adolescents. METHODS: A probabilistic sample including 577 adolescent students aged 12-19 years in 2003 (210 males and 367 females) from state public schools in the city of Niterói, Southeastern Brazil, was studied. The Receiver Operating Characteristic curve was used to identify the best age-adjusted BMI cut-off for predicting high levels of serum total cholesterol (>150mg/dL), LDL-C (>100mg/dL), serum triglycerides (>100mg/dL), plasma glucose (>100mg/dL) and low levels of HDL-C (< 45mg/dL). Four references were used to calculate sensitivity and specificity of BMI cut-offs: one Brazilian, one international and two American. RESULTS: The most prevalent metabolic alterations (>50%) were: high total cholesterol and low HDL-C. BMI predicted high levels of triglycerides in males, high LDL-C in females, and high total cholesterol and the occurrence of three or more metabolic alterations in both males and females (areas under the curve range: 0.59 to 0.67), with low sensitivity (57%-66%) and low specificity (58%-66%). The best BMI cut-offs for this sample (20.3 kg/m² to 21.0 kg/m²) were lower than those proposed in the references studied. CONCLUSIONS: Although BMI values lower than the International cut-offs were better predictor of some metabolic abnormalities in Brazilian adolescents, overall BMI is not a good predictor of these abnormalities in this population.
Resumo:
Com o presente documento pretende-se abordar e identificar os diferentes factores que influenciam directamente a produção e execução de uma escavação subterrânea, com especial relevo sobre a influência exercida pela geotecnia do maciço intersectado. Inicialmente são focados os principais aspectos a ter em conta na caracterização geotécnica de um maciço, seguindo-se uma introdução a diferentes métodos de escavação actuais e metodologias de suporte de uma obra subterrânea, com particular realce para os utilizados em maciços brandos. Depois de tratados estes conceitos, é apresentada uma obra subterrânea em execução que foi acompanhada durante 4 meses para efeitos de desenvolvimento deste estudo. Assim, são abordados neste documento diferentes aspectos construtivos, no que diz respeito à mão-de-obra utilizada, metodologias e técnicas aplicadas, redes técnicas auxiliares instaladas, produções e rendimentos verificados. De seguida e de modo a atestar a importância da caracterização geotécnica ao longo da obra, foi feito um estudo do maciço intersectado, relativamente às descontinuidades que o intersectam, litologia, alteração, e resistência à compressão. Para este último parâmetro foram utilizadas técnicas distintas mas complementares, nomeadamente o ensaio de carga pontual (em laboratório), e o esclerómetro portátil (in situ). Por último, tendo em conta os parâmetros e características presentes e as implicações que uma obra do género acarreta, são propostas de modo sucinto, técnicas alternativas de escavação do maciço cuja viabilidade de implementação seja possível no contexto em questão.