997 resultados para Manutenção de equipamento


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work study of solar distillation feasibility in effluent of petroleum industry: produced water, making possible your reuse for irrigation of oleaginous cultures or fodder crops or in steam generation, as well the transport phenomena involved. The methodology for development of this project was to characterize the effluent to be treated and to accomplish physical and chemical analysis in the distilled, to build distillation equipment, concomitant operation of both equipments and implementation of data processing and economical evaluation. The methodology used for all parameters is outlined in APHA (1998) and sampling of the type compound. The feeding of distillation equipment was performed with treated effluent from UTPF of Guamaré. The temperature was monitored throughout the distillers and during the time of operation. The distillers feed occur, as a rule, for sifon. The distillers were operated by a period of 17 months between July 2007 and February 2009, in which 40 experiments were performed. The radiation and temperature datas were acquired in the INPE s site and the temperature inside of the distillers was registered by DATALOGGER Novus. The rates of condensation (mL / min) were determined by measuring of the flow in a graduate test tube of 10 mL and a chronometer. We used two simple solar effect distillers of passive type with different angles in coverage: 20 ° and 45 °. The results obtained in this study and the relevant discussions are divided into six topics: sample characterization and quality of distilled; construction of distillers; operation (data, temperature profile), climatic aspects, treatment of data and economical analysis. Results obtained can be inferred that: the energy loss by the adoption of vessel glass was not significant, however, complicates the logistics of maintenance the equipment on a large scale. In the other hand, the surface of the tub with a glass shield on the equipment deterioration, both devices showed similar performance, so there is not justified for use of equipment 450. With regard to the climatological study it was verified that the Natal city presents monthly medium radiation varying in a range between 350 and 600 W/m2, and medium of wind speed of 5 m / s. The medium humidity is around 70% and rainfall is very small. The regime of the system is transient and although it has been treated as a stationary system shows that the model accurately represents the distillers system's 20 degrees. The quality of the distilled with regard to the parameters evaluated in this study is consistent with the Class 3 waters of CONAMA (Resolution 357). Therefore we can conclude that solar distillation has viability for treat oilfield produced water when considered the technical and environmental aspects, although it is not economically viable

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The simulation of SES-Natal Ponta Negra: mitigation of environmental risks and predictive maintenance strategy was developed in the context of several operational irregularities in the pumping stations and sewage systems in the system Ponta Negra. Thus, the environmental risks and complaints against the company due to overflows of sewage into the public thoroughfare became common. This neighborhood has shown in recent years an increase of resident higher than the initial expectation of growth. In this sense presumed the large population growth and generation of sewers higher than expected, associated to the use of corrective maintenance and misuse of the system may be the main causes of operational failures occurring in the SES. This study aimed at analyzing the hydraulic behavior of SES Ponta Negrathrough numerical simulation of its operation associated to future scenarios of occupation. The SES Ponta Negra has a long lengthof collection networks and 6 pumping stations interconnected, being EE 1, 2, 4 coastal way, and beach Shopping interconnected EE3 to receives all sewers pumped from the rest pumping station and pumped to the sewage treatment station of neighborhood which consists of a facultative pond followed by three maturation ponds with disposal of treated effluent into infiltration ditches. Oncethey are connected with each other, the study was conducted considering the days and times of higher inflow for all lifts. Furthermore, with the aim of measuring the gatherer network failures were conducted data survey of on the networks. Thephysical and operational survey data was conducted between January/2011 and janeiro/2012. The simulation of the SES was developed with the aim ofdemonstrating its functioning, eithercurrently and in the coming years, based in population estimates and sewage flow. The collected data represents the current framework of the pumping stations of the SES Ponta Negra and served as input to the model developed in MS Excel ® spreadsheet which allowed simulating the behavior of SES in future scenarios. The results of this study show thatBeach Shopping Pumping Station is actually undersized and presents serious functioning problemsthatmay compromise the environmental quality of surrounding area. The other pumping stations of the system will reach itsmaximum capacity between 2013 and 2015, although the EE1 and EE3 demonstrateoperation capacity, even precariously, until 2017. Moreover, it was observed that the misuse of the network system, due to the input of both garbage and stormwater, are major factors of failures that occur in the SES. Finally, it was found that the corrective maintenance appliance, rather than predictive,has proven to beinefficient because of the serious failuresin the system, causing damage to the environment and health risks to users

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experience in the use of stabilization ponds shows that this is a system with low cost, easy operation and maintenance and suitable for tropical countries. One of its disadvantages is due to high concentrations of suspended solids, mainly due to algal biomass in the effluents. Accordingly, the dissolved air flotation has been shown to be an efficient post-treatment technology. However, the efficiency of this process is related to coagulation and flocculation steps, as well as the adjustment of the involved variables in the process. The objective of this work was to evaluate the algae removal efficiency from wastewater stabilization ponds and the influence of the factors involved in the process using dissolved air flotation. For this, we used primary facultative and maturation effluents of ETE Ponta Negra in Natal. We did tests of coagulation, flocculation and flotation with the samples, using the equipment flotatest. In this process were tested coagulants aluminum sulfate and ferric chloride, and varied the factors pH, coagulant concentration, polymer concentration and rate of recirculation. At the end of the experiments were analyzed turbidity, suspended solids, color, COD and chlorophyll "a". These results were submitted to descriptive statistics to verify the efficiency of the process in general, and regression analysis to identify models that describe the process and demonstrate the factors that have greater influence on flotation. After step methodology, high values were found removal efficiency of suspended solids, reaching values greater than 90% in the best cases. It was concluded that flotation is more efficient in the facultative pond effluent using ferric chloride, and the variability of algae may negatively influence the process. Regression analyzes showed that pH is the most influential variable in the coagulation-flocculation-flotation, and its optimal value among the tested is 5.5 for both coagulants

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo visou à obtenção das curvas de calibração de um equipamento de TDR (Time Domain Reflectometry) em cinco solos da região de Piracicaba, SP, e testou a adequação da calibração interna do equipamento e das curvas genéricas de calibração. As curvas ajustadas, em cada solo separadamente, apresentaram coeficientes de determinação (R²) da ordem de 0,99, e a curva ajustada para o conjunto de dados dos cinco solos apresentou R² = 0,976. A análise de erros-padrão de estimativa mostrou que as curvas genéricas não se prestam às aplicações mais sensíveis, tais como na determinação absoluta do conteúdo de água do solo. Os testes de comparação entre as curvas ajustadas, a curva genérica e a curva embutida no equipamento mostraram que a primeira é superior às demais. O estudo mostrou, também, que a curva de calibração embutida no equipamento é inadequada para as determinações de umidade nos cinco solos estudados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of fixed orthodontics appliances interfere on sanitation, allowing periodontal diseases to appear, despite the fact patients keep on visiting the dentist every month. This research aims to determine a protocol for the mechanical control of the dental biofilm performed by the professional. A protocol that was able to maintain the periodontal health of the patients under orthodontic treatment with fixed appliances, and in order to do so, it used a non-controlled, randomized and blind clinical essay. The sample involved 40 adolescents who were under the installation of fixed orthodontics appliances and it was divided in three groups, as follows: monthly controlled group (group 1) composed of 11 patients, the quarterly controlled group (group 2) with 16 patients and the semestrial controlled group (group 3) with 13 patients. For data collection, an interview and clinical exams with probing depth measurement, quantity of keratinized mucosa, Gingival Index and the Plaque Index were used. On the initial exam all patients received brushing guidelines as well as the professional control of dental biofilm, with periodontal scaler, Robinson s brush and prophylactic paste. However, Group 1 returned every month for control procedures; Group 2 every three months and Group 3 after six months. The intervention had a six-month duration (for all the three groups), when all the exams were repeated by another examiner who did not know which group each patient was inserted in. Finally, the research concluded that despite the fact there is no statistically significant difference among the three groups, clinically the patients from the monthly group presented a better response to professional control, with less accumulation of dental biofilm and less rate of gingival inflammation. Thus, the mechanical control of the dental biofilm performed by the professional could not avoid gingival increase, characterized by the raise of probing depth measurement, neither the quantity of keratinized mucosa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the increase of processing ability, storage and several kinds of communication existing such as Bluetooth, infrared, wireless networks, etc.., mobile devices are no longer only devices with specific function and have become tools with various functionalities. In the business field, the benefits that these kinds of devices can offer are considerable, because the portability allows tasks that previously could only be performed within the work environment, can be performed anywhere. In the context of oil exploration companies, mobile applications allow quick actions could be taken by petroleum engineers and technicians, using their mobile devices to avoid potential catastrophes like an unexpected stop or break of important equipment. In general, the configuration of equipment for oil extraction is performed on the work environment using computer systems in desktop platforms. After the obtained configuration, an employee goes to equipment to be configured and perform the modifications obtained on the use desktop system. This management process equipment for oil extraction takes long time and does not guarantee the maintenance in time to avoid problems. With the use of mobile devices, management and maintenance of equipment for oil extraction can be performed in a more agile time once it enables the engineer or technician oil can perform this configuration at the time and place where the request comes for example, near in the oil well where the equipment is located. The wide variety of mobile devices creates a big difficulty in developing mobile applications, since for one application can function in several types of devices, the application must be changed for each specific type of device, which makes the development quite costly. This paper defines and implements a software product line for designing sucker-rod pumping systems on mobile devices. This product line of software, called BMMobile, aims to produce products that are capable of performing calculations to determine the possible configurations for the equipment in the design suckerrod pumping, and managing the variabilities of the various products that can be generated. Besides, this work performs two evaluations. The first evaluation will verify the consistency of the products produced by the software product line. The second evaluation will verify the reuse of some products generated by SPL developed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Com o objetivo de avaliar as alterações cardiocirculatórias resultantes da manutenção anestésica com sevofluorano, três grupos de 10 cães cada foram anestesiados por 60 minutos com fluxo diluente de 100% de oxigênio (grupo 1), de 50% de oxigênio e de óxido nitroso (grupo 2) ou 27% de oxigênio e 63% de óxido nitroso (grupo 3). A tranqüilização foi realizada com levomepromazina (0,5 mg/kg) e a indução com tiopental (12,5 mg/kg). A freqüência cardíaca apresentou elevação significativa após a indução (P<0,05), mantendo-se mais alta que a basal, em todos os grupos, durante toda a anestesia. As variações das pressões arteriais sistólica, média e diastólica foram pouco significativas e mantiveram-se em todos os grupos dentro de valores aceitáveis para a espécie e a utilização do óxido nitroso não interferiu nessa variação. O sevofluorano demonstrou ser um bom agente de manutenção anestésica em cães, e a adição de 63% de óxido nitroso ao fluxo diluente de oxigênio reduziu a necessidade anestésica de maneira significativa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our objective was to evaluate the impacts caused on pond water quality by maintenance of Macrobrachium rosenbergii broodstock. During eight weeks we determined pH, dissolved oxygen (DO), conductivity, turbidity, particulate suspended material (PSM), nitrogen (N) and phosphorus (P), all in inlet and effluent water. All variables presented higher values in the effluent, except OD. N-ammoniacal concentration (0.013 mg L(-1)) was 2.7 times higher in the effluent pond; NO(2)-N (0.019 mg L(-1)), 2.3; NO(3)-N (0.139 mu g L(-1)), 1.8; PO(4)-P (0.065 mg L(-1)), 7.2; and DP (0,104 mg L(-1)), 4.9 times higher. For TKN (0.67 mg L(-1)) and TP (0.235 mg L(-1)) the values in the pond effluent represent an increase of 0.27 mg L(-1) and 0.175 mg L(-1), respectively. The maintenance of M. rosenbergii broodstock increase the nutrient concentrations, mainly TP, prevent effluent pond released into receiving water bodies on 1, 2 and 3 classes of the CONAMA N degrees 357 Resolution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

0 objetivo do trabalho foi determinar o melhor tratamento pós-colheita para manutenção floral e aumento da longevidade de crisântemo de maço do tipo pompom (Dendranthema grandiflorum (Ramat.) S. Kitamura) cv. White Polaris. Estabeleceu-se como ponto de colheita o momento em que as hastes apresentavam três inflorescências apicais com as pétalas externas em ângulo de 45&deg; em relação à horizontal. Durante o ensaio em laboratório, as hastes, colhidas em estufa de produção comercial, após totalmente imersas em água de torneira, à sombra, durante três horas, foram cortadas sob água na base do caule entre 50 e 60 cm. As hastes foram distribuídas nos diferentes tratamentos de pulsing durante 24 horas, com luz contínua de 1.500 lux, 60 a 90% de umidade relativa do ar e temperatura ambiente de 25 ± 2&deg;C. No primeiro experimento, testou-se a eficiência de 8-hidroxiquinolina (8-HQ) e tiabendazole (TBZ) como germicidas de manutenção da qualidade na solução de pulsing; testaram-se, também, dois reguladores de crescimento, a saber: ácido giberélico (GA3), 6-benzilaminopurina (6-BA) ou a mistura dos dois, com o objetivo de preservar a cor e a turgidez da folhagem. Os melhores resultados foram com 8-HQ (0,69 mol/m³) e GA3 (0,058 mo1/m³). No segundo experimento, avaliaram-se os seguintes inibidores de etileno: tiossulfato de prata (STS), nitrato de prata (AgNO3) e cloreto de cobalto (COC1(2)). A melhor resposta foi obtida com AgNO3 (2,9 e 4,4 mo1/m³).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: A manutenção de concentração sangüínea alvo-controlada em níveis aproximadamente constantes do propofol é uma técnica que pode ser empregada de modo simplificado na sala de cirurgia. A finalidade desta pesquisa é comparar clínica e laboratorialmente a infusão de propofol em crianças usando os atributos farmacocinéticos de Short e de Marsh. MÉTODO: Foram estudados 41 pacientes com a idade de 4 a 12 anos, de ambos os sexos, estado físico ASA I ou II, distribuídos em dois grupos S (20 pacientes) e M (21 pacientes). No Grupo S utilizaram-se os atributos farmacocinéticos de Short, e no Grupo M, os atributos farmacocinéticos de Marsh. A indução anestésica foi feita com bolus de alfentanil 30 µg.kg-1, propofol 3 mg.kg-1 e pancurônio, 0,08 mg.kg-1 por via venosa. Procedeu-se a intubação traqueal e a manutenção com N2O/O2 (60%) em ventilação controlada mecânica. No grupo S a infusão de propofol foi de 254 (30 min) seguido de 216 µg.kg-1.min-1 por mais 30 min. No grupo M a infusão de propofol foi de 208 (30 min) seguido de 170 µg.kg-1.min-1 por mais 30 min. Através do atributo farmacocinético específico a cada grupo a meta foi a obtenção da concentração-alvo de 4 µg.kg-1 de propofol. Foram colhidas três amostras sangüíneas (aos 20, 40 e 60 minutos) para a dosagem do propofol pelo método da Cromatografia Líquida de Alta Performance. RESULTADOS: Os Grupos S e M foram considerados similares quanto à idade, altura, peso e sexo (p > 0,05). Não houve diferença estatística significativa entre os dois grupos estudados para os parâmetros: PAS, PAD, FC, FiN2O, SpO2 da hemoglobina e P ET CO2 no final da expiração. A comparação entre grupos no número de bolus repetidos de alfentanil não foi estatisticamente significativa. O índice bispectral (BIS) não apresentou diferença estatisticamente significativa entre M0 (vigília) e os demais momentos em ambos os grupos. Os valores Medianos da Performance do Erro (MPE) e os valores Medianos Absolutos da Performance do Erro (MAPE) mostraram diferenças estatísticas significativas entre os grupos no momento 60. Valores medianos da concentração sangüínea de propofol (µg.kg-1) mostraram diferenças estatísticas significativas entre M e S no momento 60 e entre os momentos 40 e 60 no grupo S. CONCLUSÕES: A anestesia com propofol usando os atributos farmacocinéticos de Marsh (Grupo M) apresentou menor erro no cálculo da concentração-alvo de propofol de 4 µg.kg-1. Além disso, utiliza menor quantidade de propofol para obter resultados clínicos semelhantes. Por todas essas qualidades deve ser a preferida para uso em crianças ASA I e com idades entre 4 e 12 anos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O desenvolvimento e uso de técnicas que prolonguem a durabilidade das flores, mantendo a qualidade do produto, é imprescindível para redução de perdas pós-colheita. Objetivou-se, neste trabalho, avaliar soluções de manutenção, associadas ou não a sacarose, na manutenção da qualidade pós-colheita de hastes de crisântemos. O experimento foi conduzido sob delineamento inteiramente casualizado, em esquema fatorial, com cinco tratamentos e três repetições, com 2 hastes florais cada uma. Os tratamentos utilizaram água destilada; 8-HQC a 100 mg L-1; 8-HQC a 100 mg L-1 + sacarose a 50 g L-1, 8-HQC a 200 mg L-1; 8-HQC a 200 mg L-1 + sacarose a 50 g L-1. Foram feitas avaliações físicas: coloração, massa fresca e conteúdo relativo de água (CRA); avaliações químicas: açúcares redutores e pigmentos; e avaliações qualitativas: turgescência, cor das flores, e número de botões, flores entreabertas e abertas. A combinação de 8-HQC 200 mg L-1 + sacarose a 50 g L-1 foi a que apresentou melhor desempenho para a manutenção da qualidade das hastes florais, favorecendo a abertura de botões e a turgescência das lígulas. A sacarose contribuiu para uma melhor manutenção de substâncias de reserva na haste, que tiveram a sua vida de vaso estendida.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of masks is generally accepted as a means of protecting the individual against microbial pathogens that might be inhaled in unhealthy environments. The objective of this study was to evaluate the efficiency of disposable surgical masks sold in Brazil, against coliforms in aerosols emitted by the aerators of a sanitary sewage treatment station. The filtration efficiency varied from 50.9% to 99.9% for 6 masks from different sources.