897 resultados para Mandibular fractures
Resumo:
Purpose: to radiographically evaluate the distance between mandibular lingula and the exact spot where buccal and lingual cortical bone plates merge in the mandibular ramus. Materials and Methods: 54 dry mandibles, divided into 3 subgroups (SG1: dentate, SG2: partially dentate and SG3: edentulous) were used in this study. Lingula position was marked with a metallic sphere and radiographs were taken. The distance between mandibular notch and lingula (I/L) and the distance between mandibular lingula and cortical bone plates fusion (L/FC) were measured. Statistical analysis was applied to the values obtained. Results: mean values for L/FC were 8,18mm, 7,30mm and 8,98mm for SG1, SG2 e SG3 respectively. Moreover, mean values for I/L were 14,02mm, 13,90mm and 12,34mm for SG1, SG 2 and SG3 respectively. The results also showed that cortical bone plates fusion took place in half I/L distance in 28,57% of the mandibles in SG1, in 46,67% of the mandibles in SG2 and in 9,09% of the pieces in SG3. Conclusions: there were no statistically significant differences in the height where cortical bone plates took place in all 3 subgroups. In SG3, the correlation between the mean value for L/FC and the mean value for I/L suggests a reduction in bone density and bone mass, which can correlate to the evaluation of older mandibles in this subgroup.
Resumo:
Dislocated subcondylar fractures often require open reduction and internal fixation. This treatment modality results in better anatomy, early function, and facilitated physical therapy. Ideal stable fixation is obtained by use of two miniplates to control the tension zone in the sigmoid notch area and stabilize the posterior border region or, if there is not enough space, one stronger plate. That is most frequently achieved through extraoral approaches. Recently new instruments have facilitated the use of an intraoral approach, which is used usually with the aid of an endoscope. However, it is possible to perform the procedure without the endoscope if proper instruments and clinical mirrors for checking the posterior border reduction and fixation are used. A case of reduction and fixation of a medially dislocated condylar fracture is presented and discussed.
Resumo:
This paper presents a case report with the use of short dental implants and immediate prosthesis placement. After 13 months of follow-up, peri-implant probing values are near 1.87 mm and ISQ values around 78.56.
Resumo:
Jaws atrophy represents a great challenge to Implantology regarding rehabilitation of edentulous areas. This paper reports an extreme mandibular atrophy with only 9mm of height between the mental foramina. In these situations, treatment options include bone augmentation techniques, transmandibular, or short dental implants. It is well accepted that bone grafts to improve height do not have good predictability. Besides, osteogenic distraction is associated with a great patient discomfort and transmandibular implants are related with high failure rates. Also, surgical-prosthetic rehabilitations with short dental implants had been associated to good success rates. The purpose of this clinical case is to report a severe mandibular atrophy, successfully treated with four short dental implants between mental foramina for implant-supported prosthesis.
Resumo:
Aims: This study compared fractal dimension (FD) values on mandibular trabecular bone in digital and digitized images at different spatial and contrast resolutions. Materials and Methods: 12 radiographs of dried human mandibles were obtained using custom-fabricated hybrid image receptors composed of a periapical radiographic film and a photostimulable phosphor plate (PSP). The film/ PSP sets were disassembled, and the PSPs produced images with 600 dots per inch (dpi) and 16 bits. These images were exported as tagged image file format (TIFF), 16 and 8 bits, and 600, 300 and 150 dpi. The films were processed and digitized 3 times on a flatbed scanner, producing TIFF images with 600, 300 and 150 dpi, and 8 bits. On each image, a circular region of interest was selected on the trabecular alveolar bone, away from root apices and FD was calculated by tile counting method. Two-way ANOVA and Tukey’s test were conducted to compare the mean values of FD, according to image type and spatial resolution (α = 5%). Results: Spatial resolution was directly and inversely proportional to FD mean values and standard deviation, respectively. Spatial resolution of 150 dpi yielded significant lower mean values of FD than the resolutions of 600 and 300 dpi ( P < 0.05). A nonsignificant variability was observed for the image types ( P > 0.05). The interaction between type of image and level of spatial resolution was not signi fi cant (P > 0.05). Conclusion: Under the tested, conditions, FD values of the mandibular trabecular bone assessed either by digital or digitized images did not change. Furthermore, these values were in fluenced by lower spatial resolution but not by contrast resolution.
Resumo:
Osteochondroma (OC) is the most common benign tumor of long bones. However it is rarely found in the facial skeleton, being the coronoid process and mandibular condyle the most affected sites in this region. It basically consists in bone growth covered by cartilage. The etiology is still controversial: neoplastic, developmental, reparative and traumatic origins have been discussed in literature. The treatments of these lesions include total condylectomy or local resection of the lesion. This paper aims to report a case of a patient with history of trauma and possible fracture of the mandibular condyle in childhood, which in youth developed dentofacial deformity with severe facial asymmetry. The treatment consisted of resection of lesion both with maxillary and mandibular osteotomies associated with graft from the iliac crest bone. Actually, the patient is with a favorable aesthetic, without functional deficit and absence of lesion’s recurrence.
Resumo:
Crowns made from an yttria-stabilized tetragonal zirconia polycrystals (3Y-TZP) core with a porcelain veneer have shown high clinical failure rates. Manifestations of clinical failure in veneering ceramic ranges from a single chip to an extended fracture. Core failures are uncommon but usually are catastrophic. This article examines the possible causes of failure in zirconia systems and presents a case report involving the diagnosis and repair of three different types of failure in six 3Y-TZP/porcelain crowns.
Resumo:
The oral rehabilitation of edentulous patients with immediate loading has become a safe procedure with high predictability. The success is related to immediate fabrication of a passive fit framework to attach the implants. Based on these considerations, this case report shows an alternative technique for mandibular rehabilitation using implants immediately loaded, where the framework was fabricated using cylinders with internal reinforcement and precast pieces, electrowelding, and conventional welding providing esthetics and function to the patient in a short period of time.
Resumo:
The hypertrophy of the mandibular coronoid process is a rare condition, progressive and of unknown etiology, characterized by the over development of the coronoid process determining their size increased, resulting in progressive and painful limitation of mouth opening. The mandibular hypomobility is a present symptom in several diseases and associates it to a specific cause requires detailed clinical and imaginologic examination. The cone-beam computed tomography has the potential to provide complementary informations above than conventional radiography. It also has the advantage of eliminate overlaps, provide high resolution image, helping not only in diagnosis, but also in planning the surgical procedure. Here we report a case of male patient, who appeared at the clinic for an evaluation of a trismus. He had no pain, only discomfort for progressive limitation of mouth opening. On physical examination, only a limited mouth opening has been found. Although the movements of laterality and protrusión were posible, they were very limited. Cone-beam computed tomography examination was performed, that showed an image compatible with bilateral hypertrophy of the mandibular coronoid process.
Resumo:
Purpose: The authors tried to verify the anatomic location of the mandibular foramen and língula in dry jaws regarding the anterior and posterior border of the mandible and the incisure, alveolar border and mandibular base, in order to correlate the data with the sagittal split ramus osteotomy. Methods: There were evaluated 44 mandibles (88 sides) from the Morphology Department of the Araraquara Dental School of the São Paulo University (UNESP). The distances measured were previously deter - mined according to the figures presented in this article and were done by the use of a sliding caliper (Brow & Sharpe Digit-Cal Plus), with the mandibles positioned over a Erickson table, and the distan - ces were always measured in millimeters. Results: The pre-determined points and distances founded were X=17,67; Y=14,35; W=20,96 and Z=21,89 for the mandibular foramen, and the relationship between this anatomical structure and the língula shows that the mandibular foramen is in average 5,82 mm below the língula. Conclusions: The authors conclude that the mandibular foramen is lightly posterior in comparison with the ramus mandibular center and that the língula is a very important anatomic landmark for the ramus surgeries as well the knowledge of the distance between it and the mandibular foramen entrance.
Resumo:
Objective: This study evaluated the effects of root canal obturation employing lateral compaction technique and spreader load of 1.5 kg on the incidence of complete (CVRF) or incomplete vertical root fractures (IVRF). Material and Methods: Twenty-seven distal roots of extracted human mandibular molars were used. All root canals were prepared by biomechanical step-back technique and obturated by lateral compaction technique. The prepared roots were distributed into two groups: G1- experimental (n = 17) and G2- control (n = 10). During obturation, load of 1.5 kg was applied to a size # 30 finger spreader. Pre- and post-obturation images of the coronal portion of the roots were captured by inverted digital microscopy and analyzed by one trained examiner. Data were evaluated by Fisher’s test (p < 0.05) using GrapH Pad Prism 5.0. Results: No roots exhibited CVRF. All fractures observed before and after obturation were IVRF or “other defects”. In G2 (control group), there was no increase of IVRF number. Interestingly, G1 presented an increase in the IVRF number to 70.59% in the 12 teeth out of 17 teeth studied. The statistical analysis showed that the mean of IVRF increased significantly in G1 when compared to G2 (p < 0.05). Conclusion: The application of a 1.5 kg spreader load during lateral compaction technique does not produce complete vertical root fractures, but may produce incomplete fractures or “other defects”.
Resumo:
Purpose: The purpose of this study was to evaluate the increase of the cervical area and dentin thickness in mesial and distal walls of the mesial canals from mandibular molars after the use of LA Axxess (LA), CP Drill (CP) and Gates-Glidden (GG) rotary instruments. Material and Methods: Sixty root canals from thirty mandibular first molar were sectioned 3 mm below the cement-enamel junction, divided in 3 groups (n = 20 root canals, each) according to rotary instrument used, and the cervical images were captured before and after pre-enlargement instrumentation. The increase of the instrumented cervical area (mm2) and the dentin removal thickness (mm), at mesial and distal walls were calculated using Image tools software, by comparison of images. Data were analyzed by ANOVA and Tukey tests (p=0.05). Results: All rotary instruments promoted thickness reduction in dentin walls. In mesial wall, all rotary instruments promoted similar thickness reduction of dentinal wall and did not differ from each other (p>0.05). In distal wall, LA Axxess instrument promoted higher dentin thickness reduction than other groups (p<0.05). The three rotary instruments promoted different increase at the instrumented cervical area (p<0.05), LA promoted the highest increase area and GG and CP presented similar results. Conclusion: LA 20/0.06 promoted the highest thickness reduction in distal wall and increase of cervical area of root canal. On the other hand, CP was the safest instrument, with lower dentin removal of distal wall and similar increased area to GG.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)