996 resultados para Malaria detection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lectins were labeled with fluorescein and tried as conjugates in the immunofluorescence (IP) test for the detection of IgM antibodies to T. gondii, in the diagnosis of acute toxoplasmosis. This approach was an attempt to find alternative reagents for anti-human IgM fluorescent conjugates (AHIgMFC), which contain quite frequently anaibcdies to toxoplasma, as contaminants, due to natural T. gondii infections among animals used for imunization. Lentil (Lens culinaris) lectin fluorescence conjugates (LcFC) provided most satisfactory results. The evaluation of LcFC carried out in a total of 179 sera from patients with acute and chronic toxoplasmosis, with non-related infections or healthy subjects, gave high values of relative efficiency, co-positivity and co-negativity indices, respectively 0.989, 0.969 and 1.000, in reference to the conventional AHIgMFC. Moreover, three batches of LcFC successively prepared gave reproducible test results. The advantage of LcFC as an alternative reagent for the serodiagnosis of acute toxoplasmosis is supported by practical aspects of its preparation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os autores estudaram a prevalência da deficiência de glicose-6-fosfato desidrogenase (G6PD), pelo método de BREWER et alii, em 141 indivíduos da população do município de Humaitá, Estado do Amazonas. Destes, 128 eram amazônides, 67 dos quais nunca tiveram malária, enquanto que 61 tinham tido ou estavam tendo a doença; os 13 restantes que estavam com malária não eram arnazônides. Os resultados revelaram que 7 arnazônides (4,96%), eram deficientes. Destes, 5 eram do sexo feminino e 2 do masculino. Em todos os indivíduos do sexo feminino o teste foi positivo com comportamento do tipo heterozigoto. Dos indivíduos deficientes, 4 nunca tinham tido malária; dos outros 3, 2 apresentavam a reação de hemaglutinação positiva com título 1/16 e o terceiro estava tendo malária causada pelo Plasmodium falciparum pela primeira vez. Este doente apresentou forma benigna de malária evoluindo para cura clínica e parasitológica no 3.° dia de tratamento com a clindamicina. Nenhum dos 13 doentes não arnazônides apresentava deficiência de G6PD. Dessa forma, não houve diferença na prevalência da deficiência de G6PD em arnazônides que nunca tiveram malária e em arnazônides que tinham tido ou estavam tendo a doença. Portanto, os indivíduos com deficiência de G6PD estão sujeitos a infecções por Plasmodium falciparum na mesma proporção que os não deficientes. Por outro lado, o aumento da prevalência da deficiência de G6PD, na amostra estudada, poderia estar relacionado com a pressão seletiva exercida pela malária em população submetida à homozigose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the main difficulties related to the detection of the Hepatitis Delta Virus (HDV) antigen and antibody has been the source of the needed HD antigen since HDV containing human and animal livers are very difficult to obtain and since yield is low. This fact prompted us to try to use the serum of patients in the acute phase of HDV infection as a source of HDAg and turn to enzyme immunoassays (EIA) instead of RIA for the sake of easiness and economy in the amount of HDAg needed. The antigen for EIA was obtained from patients during the acute phase of HDV infection and the antibody from patients who have been carriers for many years. For the detection of the antigen, a sandwich type method was employed, whereas for the antibody a competition assay was developed. In order to assess the relative specificity and sensibility of the test, the antibody assay was compared to a commercial RIA (C. RIA, Abbott) and to a non-commercial RIA (NC RIA). Forty-two sera were tested by the two methods and only in two cases discrepant results were obtained. Its is concluded that: 1) sera from patients in the acute and chronic phases of HDV infection can be used as source of both antigen and antibody, for immunoassays; 2) EIA and RIA have comparable relative specificity and sensibility and 3) EIA is easier to perform, cheaper, non-hazardous, has a longer shelf-life and saves scarce HDAg.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent studies of mobile Web trends show a continuous explosion of mobile-friendly content. However, the increasing number and heterogeneity of mobile devices poses several challenges for Web programmers who want to automatically get the delivery context and adapt the content to mobile devices. In this process, the devices detection phase assumes an important role where an inaccurate detection could result in a poor mobile experience for the enduser. In this paper we compare the most promising approaches for mobile device detection. Based on this study, we present an architecture for a system to detect and deliver uniform m-Learning content to students in a Higher School. We focus mainly on the devices capabilities repository manageable and accessible through an API. We detail the structure of the capabilities XML Schema that formalizes the data within the devices capabilities XML repository and the REST Web Service API for selecting the correspondent devices capabilities data according to a specific request. Finally, we validate our approach by presenting the access and usage statistics of the mobile web interface of the proposed system such as hits and new visitors, mobile platforms, average time on site and rejection rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A passive haemagglutination test (PHA) for human neurocysticercosis was standardized and evaluated for the detection of specific antibodies to Cysticercus cellulosae in cerebrospinal fluid (CSF). For the assay, formaldehyde-treated group O Rh-human red cells coated with the cysticerci crude total saline extract (TS) antigen were employed. A total of 115 CSF samples from patients with neurocysticercosis was analysed, of these 94 presented reactivity, corresponding to 81.7% sensitivity, in which confidence limit of 95% probability (CL95%) ranged from 74.5% to 88.9%. Eighty-nine CSF samples derived from individuals of control group presented as nonreactive in 94.4% (CL95% from 89.6% to 99.2%). The positive and negative predictive values were 1.4% and 99.9%, respectively, considering the mean rate of that this assay provide a rapid, highly reproducible, and moderately sensitive mean of detecting specific antibodies in CSF samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comparison of two different standardized reagent procedures for the passive haemagglutination test (PHA) in the detection of specific antibody to Cysticercus cellulosae in cerebrospinal fluid (CSF) was carried out. The formaldehyde-treated group O Rh-human red blood cells (HuRBC) and glutaraldehyde-treated sheep red blood cells (SRBC) were the supplies for the reagents preparation and, in the tests, they were designated as PHA-1 and PHA-2, respectively. For both reagents the cells were coated with the cysticerci total saline extract (TS) antigen. PHA-1 and PHA-2 were assessed in a total of 204 CSF from patients with neurocysticercosis, from non-related infections and from healthy individuals. The positivity and specificity indices obtained were respectively 81.7% and 94.4% for PHA-1 and for PHA-2, 88.7% and 96.6%. Since no significant differences were observed between the results provided by two reagents, at level of significance of 0.05, either processes of cell sensitization can alternatively be used according to the own laboratory convenience.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Crossed immunoelectrophoresis (IEC) was used for detection of free and complexed circulating polisaccharide anodic antigen (AgCA) of Schistosoma mansoni in sera of infected hamsters. An attempt was also done to detect AgCA in human sera from patients infected with S. mansoni. The conditions for isolation and detection of complexed AgCA were established. The sensitivity of IEC was increased by incorporation of 2% polyethylene glicol (PEG) to the agarose and by maintaining the system at 4°C during the electrophoretic run. Free AgCA was detected in 12 and the complexed in 30 of the 37 hamsters sera analysed. Correlation between AgCA (free and complexed) and the parasite load was observed. AgCA was not detected, under the experimental conditions used, in human sera from 7 patients in the acute and 23 in the chronic phase of infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

HLA antigens and their relationship with malaria infection were studied in four different ethnic groups in Colombia (South America): two groups of indians (Kunas and Katios), one of negroes and a group of mixed ancestry. A total of 965 persons were studied, 415 with malaria and 550 as controls. HLA-A,B, and C antigen frequencies in the four groups are reported. The association of each HLA antigen with malaria infection due to P. vivax and to P. falciparum was evaluated. Negroes, Kunas and Katios indians variously lack from 6 to 9 of the HLA antigens found in the mixed group. In the designated ethnic groups, antigens B5, B13, B15, Cw2 and Cw4 showed borderline association with malaria infection. However, in the mixed ethnic group, statistically significant associations were found with malaria infection and the presence of A9, Aw19, B17, B35, and Z98 (a B21-B45: crossreacting determinant) with few differences when P. vivax infection and P. falciparum infection were considered individually. This finding may represent a lack of general resistance to malaria in the group that harbors antigens of Caucasian origin. These individuals have been in direct and permanent contact with malaria only in the past 65 years. In contrast, indians, both Kunas and Katios, and Negroes have lived for centuries in malaria endemic areas, and it is possible that a natural selection system has developed through which only those individuals able to initiate an acute immune response to malaria have survived.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent studies of mobile Web trends show the continued explosion of mobile-friend content. However, the wide number and heterogeneity of mobile devices poses several challenges for Web programmers, who want automatic delivery of context and adaptation of the content to mobile devices. Hence, the device detection phase assumes an important role in this process. In this chapter, the authors compare the most used approaches for mobile device detection. Based on this study, they present an architecture for detecting and delivering uniform m-Learning content to students in a Higher School. The authors focus mainly on the XML device capabilities repository and on the REST API Web Service for dealing with device data. In the former, the authors detail the respective capabilities schema and present a new caching approach. In the latter, they present an extension of the current API for dealing with it. Finally, the authors validate their approach by presenting the overall data and statistics collected through the Google Analytics service, in order to better understand the adherence to the mobile Web interface, its evolution over time, and the main weaknesses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work the immune adherence hemagglutination test (IAHA) was standardized in a simplified procedure. This test showed good reproducibility, better than the classical mice serum neutralization test (SN). The tests showed high correlation degree: high titers in one test corresponded to high titers in the other one, and the same occured with low titers. The IAHA test is extremely simple, fast to perform, and of low cost when compared to tests such as SN or indirect immunofluorescense (IIF). It also proved to be useful in less sophisticated laboratories or even as a screening test for the titration of rabies antibodies.