891 resultados para MEAN DEVIATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The correction of oculomotor disorder in Grave's disease is applied on pathological extraocular muscles. Based on the global muscular restriction (bilateral forced duction test) and angular measurements, we have used a non-adjustable technique. PATIENTS AND METHODS: We performed a retrospective analysis of 21 patients (23 operations) with thyroid-associated orbitopathy operated for persisting diplopia. The angles of deviation in the 9 diagnostic directions of gaze and the field of binocular vision were measured with the Harm's tangent scale before and after surgery. Sixteen patients were operated only on vertical muscles. The mean follow-up was 45 months. RESULTS: 76 % of the patients (95 % confidence interval [CI], 58-94 %) obtained a large and centred field of binocular vision without prisms. 14 % (95 % CI, 0-29 %) had binocular vision with the use of prisms. Diplopia persisted in one patient despite 3 operations. Taking into consideration the interventions done before the patient was referred to us, the reintervention rate was 13 % (95 % CI, 0-28 %). CONCLUSIONS: A binocular field of vision can be successfully restored in the majority of patients with Graves' orbitopathy, using a non-adjustable surgical technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose/Objective(s): To implement a carotid dose sparing protocol using helical Tomotherapy in T1N0 squamous cell laryngeal carcinoma.Materials/Methods: Between July and August 2010, 7 men with stage T1N0 laryngeal carcinoma were included in this study. Age ranged from 47 - 74 years. Staging included endoscopic examination, CT-scan and MRI when indicated. Planned irradiation dose was 70 Gy in 35 fractions over 7 weeks. A simple treatment planning algorithm for carotid sparing was used: maximum point dose to the carotids 35 Gy, to the spinal cord 30 Gy, and 100% PTV volume to be covered with 95% of the prescribed dose. Carotid volume of interest extended to 1 cm above and below of the PTV. Doses to the carotid arteries, to the critical organs, and to the planned target volume (PTV) with our standard laryngeal irradiation protocol was compared. Daily megavoltage scans were obtained before each fraction. When necessary, the Planned Adaptive software (TomoTherapy Inc., Madison, WI) was used to evaluatethe need for a re-planning, which has never been indicated. Dose data were extracted using the VelocityAI software (Atlanta, GA), and data normalization and dose-volume histogram (DVH) interpolation were realized using the Igor Pro software (Portland, OR).Results:A significant (p\0.05) carotid dose sparing compared to our standard protocol with an average maximum point dose of 38.3 Gy (standard deviation [SD] 4.05 Gy), average mean dose of 18.59 Gy (SD 0.83 Gy) was achieved. In all patients, 95% of the carotid volume received less than 28.4 Gy (SD 0.98 Gy). The average maximum point dose to the spinal cord was 25.8 Gy (SD 3.24 Gy). PTV was fully covered with more than 95% of the prescribed dose for all patients with an average maximum point dose of 74.1 Gy and the absolute maximum dose in a single patient of 75.2 Gy. To date, the clinical outcomes have been excellent. Three patients (42%) developed stage 1 mucositis that was conservatively managed, and all the patients presented a mild to moderate dysphonia. All adverse effects resolved spontaneously in the month following the end of treatment. Early local control rate is 100% considering a 4 - 5 months post treatment follow-up.Conclusions: Helical Tomotherapy allows a clinically significant decrease of carotid irradiation dose compared to standard irradiation protocols with an acceptable spinal cord dose tradeoff. Moreover, this technique allows the PTV to be homogenously covered with a curative irradiation dose. Daily control imaging brings added security margins especially when working with high dose gradients. Further investigations and follow-up are underway to better evaluate the late clinical outcomes especially the local control rate, late laryngeal and vascular toxicity, and expected potential impact on cerebrovascular events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To objectively compare quantitative parameters related to image quality attained at coronary magnetic resonance (MR) angiography of the right coronary artery (RCA) performed at 7 T and 3 T. MATERIALS AND METHODS: Institutional review board approval was obtained, and volunteers provided signed informed consent. Ten healthy adult volunteers (mean age ± standard deviation, 25 years ± 4; seven men, three women) underwent navigator-gated three-dimensional MR angiography of the RCA at 7 T and 3 T. For 7 T, a custom-built quadrature radiofrequency transmit-receive surface coil was used. At 3 T, a commercial body radiofrequency transmit coil and a cardiac coil array for signal reception were used. Segmented k-space gradient-echo imaging with spectrally selective adiabatic fat suppression was performed, and imaging parameters were similar at both field strengths. Contrast-to-noise ratio between blood and epicardial fat; signal-to-noise ratio of the blood pool; RCA vessel sharpness, diameter, and length; and navigator efficiency were quantified at both field strengths and compared by using a Mann-Whitney U test. RESULTS: The contrast-to-noise ratio between blood and epicardial fat was significantly improved at 7 T when compared with that at 3 T (87 ± 34 versus 52 ± 13; P = .01). Signal-to-noise ratio of the blood pool was increased at 7 T (109 ± 47 versus 67 ± 19; P = .02). Vessel sharpness obtained at 7 T was also higher (58% ± 9 versus 50% ± 5; P = .04). At the same time, RCA vessel diameter and length and navigator efficiency showed no significant field strength-dependent difference. CONCLUSION: In our quantitative and qualitative study comparing in vivo human imaging of the RCA at 7 T and 3 T in young healthy volunteers, parameters related to image quality attained at 7 T equal or surpass those from 3 T.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Controlling the extracellular volume in hemodialysis patients is a difficult task. The aim of this study was to evaluate the capacity of different methods of stimulated sweating to reduce mean interdialytic weight gain (IWG), to improve blood pressure regulation, and potassium/urea balance. Two center, crossover pilot study. In Lausanne, hemodialysis patients took four hot-water baths a week, 30 minutes each, on nondialysis days during 1 month. In Sfax, patients visited the local Hammam Center four times a week. Hemodynamic parameters were recorded, and weekly laboratory analysis was performed. Results were compared with a preceding 1-month control period. In Lausanne, five patients (all men, median age 55 years) participated. Bathing temperature was (mean ± standard deviation) 41.2 ± 3°C and sweating-induced weight loss 600 ± 500 g. Mean IWG (control vs. intervention period) decreased from 2.3 ± 0.9 to 1.8 ± 1 kg (P = 0.004), Systolic blood pressure from 139 ± 21 to 136 ± 22 mmHg (P = 0.4), and diastolic blood pressure form 79 ± 12 to 75 ± 13 mmHg (P = 0.08); antihypertensive therapy could be reduced from 2.8 ± 0.4 to 1.9 ± 0.5 antihypertensive drugs per patient (P = 0.01). In Sfax (n = 9, median age 46 years), weight loss per Hammam session was 420 ± 100 g. No differences were found in IWG or BP, but predialysis serum potassium level decreased from 5.9 ± 0.8 to 5.5 ± 0.9 mmol/L (P = 0.04) and urea from 26.9 ± 6 to 23.1 ± 6 mmol/L (P = 0.02). Hot-water baths appear to be a safe way to reduce IWG in selected hemodialysis patients. Hammam visits reduce serum potassium and urea levels, but not IWG. More data in larger patient groups are necessary before definite conclusion can be drawn.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical demand for a device to monitor Blood Pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is increasing. Based on the so-called Pulse Wave Velocity (PWV) principle, this paper introduces and evaluates a novel concept of BP monitor that can be fully integrated within a chest sensor. After a preliminary calibration, the sensor provides non-occlusive beat-by-beat estimations of Mean Arterial Pressure (MAP) by measuring the Pulse Transit Time (PTT) of arterial pressure pulses travelling from the ascending aorta towards the subcutaneous vasculature of the chest. In a cohort of 15 healthy male subjects, a total of 462 simultaneous readings consisting of reference MAP and chest PTT were acquired. Each subject was recorded at three different days: D, D+3 and D+14. Overall, the implemented protocol induced MAP values to range from 80 ± 6 mmHg in baseline, to 107 ± 9 mmHg during isometric handgrip maneuvers. Agreement between reference and chest-sensor MAP values was tested by using intraclass correlation coefficient (ICC = 0.78) and Bland-Altman analysis (mean error = 0.7 mmHg, standard deviation = 5.1 mmHg). The cumulative percentage of MAP values provided by the chest sensor falling within a range of ±5 mmHg compared to reference MAP readings was of 70%, within ±10 mmHg was of 91%, and within ±15mmHg was of 98%. These results point at the fact that the chest sensor complies with the British Hypertension Society (BHS) requirements of Grade A BP monitors, when applied to MAP readings. Grade A performance was maintained even two weeks after having performed the initial subject-dependent calibration. In conclusion, this paper introduces a sensor and a calibration strategy to perform MAP measurements at the chest. The encouraging performance of the presented technique paves the way towards an ambulatory-compliant, continuous and non-occlusive BP monitoring system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The goals of our study are to determine the most appropriate model for alcohol consumption as an exposure for burden of disease, to analyze the effect of the chosen alcohol consumption distribution on the estimation of the alcohol Population- Attributable Fractions (PAFs), and to characterize the chosen alcohol consumption distribution by exploring if there is a global relationship within the distribution. METHODS: To identify the best model, the Log-Normal, Gamma, and Weibull prevalence distributions were examined using data from 41 surveys from Gender, Alcohol and Culture: An International Study (GENACIS) and from the European Comparative Alcohol Study. To assess the effect of these distributions on the estimated alcohol PAFs, we calculated the alcohol PAF for diabetes, breast cancer, and pancreatitis using the three above-named distributions and using the more traditional approach based on categories. The relationship between the mean and the standard deviation from the Gamma distribution was estimated using data from 851 datasets for 66 countries from GENACIS and from the STEPwise approach to Surveillance from the World Health Organization. RESULTS: The Log-Normal distribution provided a poor fit for the survey data, with Gamma and Weibull distributions providing better fits. Additionally, our analyses showed that there were no marked differences for the alcohol PAF estimates based on the Gamma or Weibull distributions compared to PAFs based on categorical alcohol consumption estimates. The standard deviation of the alcohol distribution was highly dependent on the mean, with a unit increase in alcohol consumption associated with a unit increase in the mean of 1.258 (95% CI: 1.223 to 1.293) (R2 = 0.9207) for women and 1.171 (95% CI: 1.144 to 1.197) (R2 = 0. 9474) for men. CONCLUSIONS: Although the Gamma distribution and the Weibull distribution provided similar results, the Gamma distribution is recommended to model alcohol consumption from population surveys due to its fit, flexibility, and the ease with which it can be modified. The results showed that a large degree of variance of the standard deviation of the alcohol consumption Gamma distribution was explained by the mean alcohol consumption, allowing for alcohol consumption to be modeled through a Gamma distribution using only average consumption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paleomagnetic investigations carried out in the 70's on Oligo-Miocene volcanics of Sardinia have demonstrated that the island was turned by 35-30 degrees clockwise from 33 Ma up to 3-1-20.5 Ma and rotated counterclockwise in a few million years [De Jong et al., 1969, 1973; Bobier et Coulon, 1970; Coulon et al., 1974; Manzoni, 1974, 1975; Bellon rr nl.. 1977: Edel et Lortscher, 1977; Edel, 1979, 1980]. Since then, the end of the rotation fixed at 19 Ma by Montigny er al. [1981] was the subject of discussions and several studies associating paleomagnetism and radiometric dating were undertaken [Assorgia er al., 1994: Vigliotti et Langenheim, 1995: Deino et al., 1997; Gattacceca rt Deino, 1999]. This is a contribution to this debate that is hampered by thr important secular variation recorded in the volcanics. The only way to get our of this problem is to sample series of successive flows as completely as possible, and to reduce the effect of secular variation by the calculation of means. Sampling was performed north of Bonorva in 5 pyroclastic flows that belong to the upper ignimbritic series SI2 according to Coulon rr nl. [1974] or LBLS according to Assorgia et al. [1997] (fig. I). Ar-40/Ar-39 dating of biotites from the debris flow (MDF) has yielded an age or 18.35 +/- 0.03 Ma [Dubois, 2000]. Five of the investigated sites are located beneath the debris flow ITV, TVB, TVD, SPM85, SPM86), one site was cured in the matrix of the debris flow (MDF) and one in 4 metric blocks included in the flow (DFC). Another site was sampled in the upper ash flow (PDM) that marks the end of the pyroclastic activity, just before the marine transgression. According to micropaleontological and radiometric dating this transgression has occurred between 18.35 and 17.6 Ma [Dubois, 2000]. After removal of a soft viscous component, the thermal demagnetization generally shows a univectorial behaviour of the remanent magnetization (fig. 2a). The maximum unblocking temperatures of 580-620 degrees (tab. I) and a rapid saturation below 100 mT (fig. 3) indicate that the carrier of the characteristic magnetization is magnetite. The exception comes: from the upper site PDM in which were found two characteristic components, one with a normal polarity and low unblocking temperatures up to 350 degreesC and one with a reversed polarity and maximum unblocking temperatures at 580-600 degreesC of magnetite. After calculation of a mean direction for each flow, the mean << Al >> direction 4 degrees /57 degrees (alpha (95) = 13 degrees) computed with the mean directions for the 5 flows may be considered as weakly affected by secular variation. But the results require a more careful examination. The declinations are N to NNW beneath the debris flow. NNW in the debris flow. and NNE (or SSW) above the debris flow, The elongated distribution of the directions obtained at sites TVB and TVD. scattered from the mean direction of TV to the mean direction of MDF is interpreted as due to partial overprinting during the debris How volcanic episode, The low temperature component PDMa is likely related to the alteration seen on thin sections and is also viewed as an overprint. As NNE/SSW directions occur as well below (mean direction << B >> : 5 degrees /58 degrees) as above the debris flow (PDMb : 200 degrees/-58 degrees). the NNW directions (<< C >> : 337 degrees /64 degrees) associated with the debris flow volcanism may be interpreted as resulting from a magnetic field excursion. According to the polarity scale of Cande and Kent [1992, 1995] and the radiometric age of MDF, the directions with normal polarity (TV, TVB, TVD, SPM85. SPM86a. MDF. DFC) may represent the period 5En. while the directions with reversed polarity PDMb and SPM86b were likely acquired during the period 5Dr. Using the mean << Al >> direction, the mean << B >>, or the PDM direction (tab. I). the deviation in declination with the direction of stable Europe 6.4 degrees /58.7 degrees (alpha (95) = 8 degrees) for a selection of 4 middle Tertiary poles by Besse et Courtillot [1991] or 7 degrees /56 degrees (alpha (95) = 3 degrees) for 19 poles listed by Edel [1980] can be considered as negligible. Using the results from the uppermost ignimbritic layer of Anglona also emplaced around 18.3 Ma [Odin rt al.. 1994]. the mean direction << E >> (3 degrees /51.5 degrees) leads to the same conclusion. On the contrary, when taking into account all dated results available for the period 5En (mean direction << D >> 353 degrees /56 degrees for 45 sites) (tab. II). the deviation 13 degrees is much more significant. As the rotation of Sardinia started around 21-20.5 Ma. the assumption of a constant velocity of rotation and the deviations of the Sardinia directions with respect to the stable Europe direction locate the end of the motion between 18.3 and 17.2 or 16.7 Ma (fig. 4). During the interval 18.35-17.5 Ma, the marine transgression took place. At the same period a NE-SW shortening interpreted as resulting from the collision of Sardinia with Apulia affected different parts of the island [Letouzey et al., 1982]. Consequently, the new paleomagnetic results and the tectono-sedimentary evolution are in favour of an end of the rotation at 17.5-18 Ma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Transthoracic echocardiography (TTE) has been used clinically to disobstruct venous drainage cannula and to optimise placement of venous cannulae in the vena cava but it has never been used to evaluate performance capabilities. Also, little progress has been made in venous cannula design in order to optimise venous return to the heart lung machine. We designed a self-expandable Smartcanula (SC) and analysed its performance capability using echocardiography. METHODS: An epicardial echocardiography probe was placed over the SC or control cannula (CTRL) and a Doppler image was obtained. Mean (V(m)) and maximum (V(max)) velocities, flow and diameter were obtained. Also, pressure drop (DeltaP(CPB)) was obtained between the central venous pressure and inlet to venous reservoir. LDH and Free Hb were also compared in 30 patients. Comparison was made between the two groups using the student's t-test with statistical significance established when p<0.05. RESULTS: Age for the SC and CC groups were 61.6+/-17.6 years and 64.6+/-13.1 years, respectively. Weight was 70.3+/-11.6 kg and 72.8+/-14.4 kg, respectively. BSA was 1.80+/-0.2 m(2) and 1.82+/-0.2 m(2), respectively. CPB times were 114+/-53 min and 108+/-44 min, respectively. Cross-clamp time was 59+/-15 min and 76+/-29 min, respectively (p=NS). Free-Hb was 568+/-142 U/l versus 549+/-271 U/l post-CPB for the SC and CC, respectively (p=NS). LDH was 335+/-73 mg/l versus 354+/-116 mg/l for the SC and CC, respectively (p=NS). V(m) was 89+/-10 cm/s (SC) versus 63+/-3 cm/s (CC), V(max) was 139+/-23 cm/s (SC) versus 93+/-11 cm/s (CC) (both p<0.01). DeltaP(CPB) was 30+/-10 mmHg (SC) versus 43+/-13 mmHg (CC) (p<0.05). A Bland-Altman test showed good agreement between the two devices used concerning flow rate calculations between CPB and TTE (bias 300 ml+/-700 ml standard deviation). CONCLUSIONS: This novel Smartcanula design, due to its self-expanding principle, provides superior flow characteristics compared to classic two stage venous cannula used for adult CPB surgery. No detrimental effects were observed concerning blood damage. Echocardiography was effective in analysing venous cannula performance and velocity patterns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Cardiovascular magnetic resonance (CMR) has become a robust and important diagnostic imaging modality in cardiovascular medicine. However,insufficient image quality may compromise its diagnostic accuracy. No standardized criteria are available to assess the quality of CMR studies. We aimed todescribe and validate standardized criteria to evaluate the quality of CMR studies including: a) cine steady-state free precession, b) delayed gadoliniumenhancement, and c) adenosine stress first-pass perfusion. These criteria will serve for the assessment of the image quality in the setting of the Euro-CMR registry.METHOD AND MATERIALS: First, a total of 45 quality criteria were defined (35 qualitative criteria with a score from 0-3, and 10 quantitative criteria). Thequalitative score ranged from 0 to 105. The lower the qualitative score, the better the quality. The quantitative criteria were based on the absolute signal intensity (delayed enhancement) and on the signal increase (perfusion) of the anterior/posterior left ventricular wall after gadolinium injection. These criteria were then applied in 30 patients scanned with a 1.5T system and in 15 patients scanned with a 3.0T system. The examinations were jointly interpreted by 3 CMR experts and 1 study nurse. In these 45 patients the correlation between the results of the quality assessment obtained by the different readers was calculated.RESULTS: On the 1.5T machine, the mean quality score was 3.5. The mean difference between each pair of observers was 0.2 (5.7%) with a mean standarddeviation of 1.4. On the 3.0T machine, the mean quality score was 4.4. The mean difference between each pair of onservers was 0.3 (6.4%) with a meanstandard deviation of 1.6. The quantitative quality assessments between observers were well correlated for the 1.5T machine: R was between 0.78 and 0.99 (pCONCLUSION: The described criteria for the assessment of CMR image quality are robust and have a low inter-observer variability, especially on 1.5T systems.CLINICAL RELEVANCE/APPLICATION: These criteria will allow the standardization of CMR examinations. They will help to improve the overall quality ofexaminations and the comparison between clinical studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates a simple procedure to estimate robustly the mean of an asymmetric distribution. The procedure removes the observations which are larger or smaller than certain limits and takes the arithmetic mean of the remaining observations, the limits being determined with the help of a parametric model, e.g., the Gamma, the Weibull or the Lognormal distribution. The breakdown point, the influence function, the (asymptotic) variance, and the contamination bias of this estimator are explored and compared numerically with those of competing estimates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: There is little information regarding the trends in body mass index (BMI) and obesity in the overall Portuguese population, namely if these trends are similar according to educational level. In this study, we assessed the trends in the prevalence of overweight and obesity in the Portuguese population, overall and by educational level. METHODS: Cross-sectional national health interview surveys conducted in 1995-6 (n=38,504), 1998-9 (n=38,688) and 2005-6 (n=25,348). Data were derived from the population and housing census of 1991 and two geographically-based strata were defined. The sampling unit was the house, and all subjects living in the sampling unit were surveyed. Height and weight were self-reported; the effects of gender, age group and educational level were also assessed by self-reported structured questionnaires. Bivariate comparisons were performed using Chi-square or analysis of variance (ANOVA). Trends in BMI levels were assessed by linear regression analysis, while trends in the prevalence of obesity were assessed by logistic regression. RESULTS: Mean (+/-standard deviation) BMI increased from 25.2+/-4.0 in 1995-6 to 25.7+/-4.5 kg/m2 in 2005-6. Prevalence of overweight remained stable (36.1% in 1995-6 and 36.4% in 2005) while prevalence of obesity increased (11.5% in 1995-6 and 15.1% in 2005-6). Similar findings were observed according to age group. Mean age-adjusted BMI increase (expressed in kg/m2/year and 95% confidence interval) was 0.073 (0.062, 0.084), 0.016 (0.000, 0.031) and 0.073 (0.049, 0.098) in men with primary, secondary and university levels, respectively; the corresponding values in women were 0.085 (0.073, 0.097), 0.052 (0.035, 0.069) and 0.062 (0.038, 0.084). Relative to 1995-6, obesity rates increased by 48%, 41% and 59% in men and by 40%, 75% and 177% in women with primary, secondary and university levels, respectively. The corresponding values for overweight were 6%, 1% and 23% in men and 5%, 7% and 65% in women. CONCLUSION: Between 1995 and 2005, obesity increased while overweight remained stable in the adult Portuguese population. Although higher rates were found among lesser educated subjects, the strong increase in BMI and obesity levels in highly educated subjects is of concern.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Non-invasive monitoring of respiratory muscle function is an area of increasing research interest, resulting in the appearance of new monitoring devices, one of these being piezoelectric contact sensors. The present study was designed to test whether the use of piezoelectric contact (non-invasive) sensors could be useful in respiratory monitoring, in particular in measuring the timing of diaphragmatic contraction.Methods: Experiments were performed in an animal model: three pentobarbital anesthetized mongrel dogs. The motion of the thoracic cage was acquired by means of a piezoelectric contact sensor placed on the costal wall. This signal is compared with direct measurements of the diaphragmatic muscle length, made by sonomicrometry. Furthermore, to assess the diaphragmatic function other respiratory signals were acquired: respiratory airflow and transdiaphragmatic pressure. Diaphragm contraction time was estimated with these four signals. Using diaphragm length signal as reference, contraction times estimated with the other three signals were compared with the contraction time estimated with diaphragm length signal.Results: The contraction time estimated with the TM signal tends to give a reading 0.06 seconds lower than the measure made with the DL signal (-0.21 and 0.00 for FL and DP signals, respectively), with a standard deviation of 0.05 seconds (0.08 and 0.06 for FL and DP signals, respectively). Correlation coefficients indicated a close link between time contraction estimated with TM signal and contraction time estimated with DL signal (a Pearson correlation coefficient of 0.98, a reliability coefficient of 0.95, a slope of 1.01 and a Spearman's rank-order coefficient of 0.98). In general, correlation coefficients and mean and standard deviation of the difference were better in the inspiratory load respiratory test than in spontaneous ventilation tests.Conclusion: The technique presented in this work provides a non-invasive method to assess the timing of diaphragmatic contraction in canines, using a piezoelectric contact sensor placed on the costal wall.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant.Material and Methods Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms.The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the microvements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion.Results 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present.Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns).Discussion Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established.Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Studies about the association between body mass index (BMI) and health-related quality of life (HRQOL) are often limited, because they 1) did not include a broad range of health-risk behaviors as covariates; 2) relied on clinical samples, which might lead to biased results; and 3) did not incorporate underweight individuals. Hence, this study aims to examine associations between BMI (from being underweight through obesity) and HRQOL in a population-based sample, while considering multiple health-risk behaviors (low physical activity, risky alcohol consumption, daily cigarette smoking, frequent cannabis use) as well as socio-demographic characteristics. METHODS: A total of 5 387 young Swiss men (mean age = 19.99; standard deviation = 1.24) of a cross-sectional population-based study were included. BMI was calculated (kg/m²) based on self-reported height and weight and divided into 'underweight' (<18.5), 'normal weight' (18.5-24.9), 'overweight' (25.0-29.9) and 'obese' (≥30.0). Mental and physical HRQOL was assessed via the SF-12v2. Self-reported information on physical activity, substance use (alcohol, cigarettes, and cannabis) and socio-demographic characteristics also was collected. Logistic regression analyses were conducted to study the associations between BMI categories and below average mental or physical HRQOL. Substance use variables and socio-demographic variables were used as covariates. RESULTS: Altogether, 76.3% were normal weight, whereas 3.3% were underweight, 16.5% overweight and 3.9% obese. Being overweight or obese was associated with reduced physical HRQOL (adjusted OR [95% CI] = 1.58 [1.18-2.13] and 2.45 [1.57-3.83], respectively), whereas being underweight predicted reduced mental HRQOL (adjusted OR [95% CI] = 1.49 [1.08-2.05]). Surprisingly, obesity decreased the likelihood of experiencing below average mental HRQOL (adjusted OR [95% CI] = 0.66 [0.46-0.94]). Besides BMI, expressed as a categorical variable, all health-risk behaviors and socio-demographic variables were associated with reduced physical and/or mental HRQOL. CONCLUSIONS: Deviations from normal weight are, even after controlling for important health-risk behaviors and socio-demographic characteristics, associated with compromised physical or mental HRQOL among young men. Hence, preventive programs should aim to preserve or re-establish normal weight. The self-appraised positive mental well-being of obese men noted here, which possibly reflects a response shift, might complicate such efforts.