856 resultados para Loop detectors.
Resumo:
Using the Otto geometry of attenuated total reflection (prism-air gap-sample), front illuminated PtSi/Si Schottky barrier detectors are shown to exhibit enhanced photocurrent at surface plasmon resonance in the near infrared region. Correlation of the measured photocurrent with the calculated transmittance of light into the Si substate is demonstrated. The transmittance, which is due to surface plasmon re-radiation, is the optical parameter of principal importance in photosignal generation since the photon energies used here are greater than the silicon intrinsic bandgap. The results presented here indicate clearly the important features in optimizing surface plasmon enhancement in photodetection both above and below the silicon absorption edge.
Resumo:
Calibration of three scintillators (EJ232Q, BC422Q, and EJ410) in a time-of-flight arrangement using a laser drive-neutron source is presented. The three plastic scintillator detectors were calibrated with gamma insensitive bubble detector spectrometers, which were absolutely calibrated over a wide range of neutron energies ranging from sub-MeV to 20 MeV. A typical set of data obtained simultaneously by the detectors is shown, measuring the neutron spectrum emitted from a petawatt laser irradiated thin foil.
Resumo:
A Micro-Hole & Strip Plate (MHSP) é uma microestrutura desenvolvida recentemente em instituições universitárias portuguesas. Neste trabalho, o seu desempenho como detector para imagiologia é explorado, tendo como objectivo a imagiologia não só de neutrões, mas também de raios X. A aplicação do método da divisão resistiva de carga é aplicada a uma MHSP especialmente desenhada para sensibilidade em posição. Várias abordagens em termos da electrónica de aquisição de sinal são testadas, sem perder de vista a relação desempenho-preço. Resoluções espaciais abaixo de 1 mm foram obtidas com a MHSP a operar em xénon e tetrafluorometano, com um sistema de detecção a um preço modesto quando comparado com as alternativas, e apropriado para inúmeras aplicações em imagiologia de neutrões e de raios X.
Resumo:
This work presents the results on the development of a high pressure Xe gaseous detector envisaging medical imaging. The detector uses two VUV photosensors operating face-to-face, based on the CsI-MHSP with position discrimination capability. The known effect of the charge gain decrease with the gas pressure is compensated with a light gain using the electroluminescence process. Studies of signal amplitude, energy and position resolution are presented. On the second part, gaseous detectors based on THGEM where studied in order to fulfill the requirements of present and future high energy physics experiments. The work is focused on the application of THGEM in RICH detectors elements: a triple THGEM detector using CsI photocathodes in Ne mixtures was suggested. The ion backflow to the photocathode remains a concern and a limitation; to minimize it, the application of a new hole-structure, THCOBRA, was suggested. Preliminary results foresee good perspectives for the successful application of THCOBRA in ion back-flow suppression. This work contains several methods and measurements of the CsI photocathodes behaviour in radiation gaseous detectors. A long discussion on its issues and possible solutions are presented.
Resumo:
Trabalho de projecto de mestrado, Educação (Especialização em Educação e Tecnologias Digitais), Universidade de Lisboa, Instituto de Educação, 2014
Resumo:
Oversampled narrow-band single-loop and multistage resonator-based bandpass sigma-delta (Σ-Δ) modulators that can accommodate different passband center to sampling frequency ratios are reported. These tunable bandpass configurations are designed by analytically determining and subsequently verifying through detailed empirical simulations the required compensation hardware to deliver enhanced noise-shaping. It is demonstrated that comparatively superior in-band signal-to-noise ratios and dynamic ranges are attributed to the inclusion of appropriate digital feedforward and feedback compensators within these structures.
Concurrent noise-shaping for multiple narrow-band single-loop and multi-stage sigma-delta modulators
Resumo:
This paper compares a carrier tracking scenario when a received Global Positioning System (GPS) signal has low Doppler frequency. It is shown that if the Numerically Controlled Oscillator (NCO) is quantized to 1 bit, the carrier tracking loop is unable to keep track of the incoming signal which leaves the tracking loop oscillating between the upper and lower bounds of the tracking loop bandwidth. One way of overcoming this problem is presented and compared with another existing solution, found in the literature, providing comparative results from the use of real-recorded off the air GPS L1 signals. Results show that the proposed method performs better tracking performance compared with the existing solution which it requires much less hardware complexity.
Resumo:
Na,K-ATPase is the main active transport system that maintains the large gradients of Na(+) and K(+) across the plasma membrane of animal cells. The crystal structure of a K(+)-occluding conformation of this protein has been recently published, but the movements of its different domains allowing for the cation pumping mechanism are not yet known. The structure of many more conformations is known for the related calcium ATPase SERCA, but the reliability of homology modeling is poor for several domains with low sequence identity, in particular the extracellular loops. To better define the structure of the large fourth extracellular loop between the seventh and eighth transmembrane segments of the alpha subunit, we have studied the formation of a disulfide bond between pairs of cysteine residues introduced by site-directed mutagenesis in the second and the fourth extracellular loop. We found a specific pair of cysteine positions (Y308C and D884C) for which extracellular treatment with an oxidizing agent inhibited the Na,K pump function, which could be rapidly restored by a reducing agent. The formation of the disulfide bond occurred preferentially under the E2-P conformation of Na,K-ATPase, in the absence of extracellular cations. Using recently published crystal structure and a distance constraint reproducing the existence of disulfide bond, we performed an extensive conformational space search using simulated annealing and showed that the Tyr(308) and Asp(884) residues can be in close proximity, and simultaneously, the SYGQ motif of the fourth extracellular loop, known to interact with the extracellular domain of the beta subunit, can be exposed to the exterior of the protein and can easily interact with the beta subunit.
Resumo:
Position sensitive particle detectors are needed in high energy physics research. This thesis describes the development of fabrication processes and characterization techniques of silicon microstrip detectors used in the work for searching elementary particles in the European center for nuclear research, CERN. The detectors give an electrical signal along the particles trajectory after a collision in the particle accelerator. The trajectories give information about the nature of the particle in the struggle to reveal the structure of the matter and the universe. Detectors made of semiconductors have a better position resolution than conventional wire chamber detectors. Silicon semiconductor is overwhelmingly used as a detector material because of its cheapness and standard usage in integrated circuit industry. After a short spread sheet analysis of the basic building block of radiation detectors, the pn junction, the operation of a silicon radiation detector is discussed in general. The microstrip detector is then introduced and the detailed structure of a double-sided ac-coupled strip detector revealed. The fabrication aspects of strip detectors are discussedstarting from the process development and general principles ending up to the description of the double-sided ac-coupled strip detector process. Recombination and generation lifetime measurements in radiation detectors are discussed shortly. The results of electrical tests, ie. measuring the leakage currents and bias resistors, are displayed. The beam test setups and the results, the signal to noise ratio and the position accuracy, are then described. It was found out in earlier research that a heavy irradiation changes the properties of radiation detectors dramatically. A scanning electron microscope method was developed to measure the electric potential and field inside irradiated detectorsto see how a high radiation fluence changes them. The method and the most important results are discussed shortly.
Resumo:
La Fibrose Kystique (FK) est une maladie dégénérative qui entraine une dégénération des poumons dû au problème de clairance mucociliaire (CMC). Le volume de surface liquide (SL) couvrant les cellules pulmonaires est essentiel à la clairance de mucus et au combat contre les infections. Les nucléotides extracellulaires jouent un rôle important dans la CMC des voies aériennes, en modifiant le volume de la SL pulmonaire. Cependant, les mécanismes du relâchement de l’ATP et de leurs déplacements à travers la SL, restent inconnus. Des études ultérieures démontrent que l’exocytose d’ATP mécano-sensible et Ca2+-dépendant, dans les cellules A549, est amplifié par les actions synergétiques autocrine/paracrine des cellules avoisinantes. Nous avions comme but de confirmer la présence de la boucle purinergique dans plusieurs modèles de cellules épithéliales et de développer un système nous permettant d’observer directement la SL. Nous avons démontrés que la boucle purinergique est fonctionnelle dans les modèles de cellules épithéliales examinés, mis appart les cellules Calu-3. L’utilisation de modulateur de la signalisation purinergique nous a permis d’observer que le relâchement d’ATP ainsi que l’augmentation du [Ca2+]i suivant un stress hypotonique, sont modulés par le biais de cette boucle purinergique et des récepteurs P2Y. De plus, nous avons développé un système de microscopie qui permet d’observer les changements de volume de SL en temps réel. Notre système permet de contrôler la température et l’humidité de l’environnement où se trouvent les cellules, reproduisant l’environnement pulmonaire humain. Nous avons démontré que notre système peut identifier même les petits changements de volume de SL.
Resumo:
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal.