965 resultados para LED light calibration system
Resumo:
This paper presents a model for the simulation of an offshore wind system having a rectifier input voltage malfunction at one phase. The offshore wind system model comprises a variable-speed wind turbine supported on a floating platform, equipped with a permanent magnet synchronous generator using full-power four-level neutral point clamped converter. The link from the offshore floating platform to the onshore electrical grid is done through a light high voltage direct current submarine cable. The drive train is modeled by a three-mass model. Considerations about the smart grid context are offered for the use of the model in such a context. The rectifier voltage malfunction domino effect is presented as a case study to show capabilities of the model. (C) 2015 Elsevier Ltd. All rights reserved.
Resumo:
A double pi'npin heterostructure based on amorphous SiC has a non linear spectral gain which is a function of the signal wavelength that impinges on its front or back surface. An impulse of a configurable length and amplitude is applied to a 390 nm LED which illuminates one of the sensor surfaces, followed by a time period without any illumination after which an input signal with a different wavelength is impinged upon the front surface. Results show that the intensity and duration of the impulse illumination of the surfaces influences the sensor's response with different output for the same input signal. This paper studies this effect and proposes an application as a short term light memory. (C) 2015 Elsevier B.V. All rights reserved.
Resumo:
Since long ago cellulosic lyotropic liquid crystals were thought as potential materials to produce fibers competitive with spidersilk or Kevlar, yet the processing of high modulus materials from cellulose-based precursors was hampered by their complex rheological behavior. In this work, by using the Rheo-NMR technique, which combines deuterium NMR with rheology, we investigate the high shear rate regimes that may be of interest to the industrial processing of these materials. Whereas the low shear rate regimes were already investigated by this technique in different works [1-4], the high shear rates range is still lacking a detailed study. This work focuses on the orientational order in the system both under shear and subsequent relaxation process arising after shear cessation through the analysis of deuterium spectra from the deuterated solvent water. At the analyzed shear rates the cholesteric order is suppressed and a flow-aligned nematic is observed which for the higher shear rates develops after certain time periodic perturbations that transiently annihilate the order in the system. During relaxation the flow aligned nematic starts losing order due to the onset of the cholesteric helices leading to a period of very low order where cholesteric helices with different orientations are forming from the aligned nematic, followed in the final stage by an increase in order at long relaxation times corresponding to the development of aligned cholesteric domains. This study sheds light on the complex rheological behavior of chiral nematic cellulose-based systems and opens ways to improve its processing. (C) 2015 Elsevier Ltd. All rights reserved.
Resumo:
O uso da tecnologia tem crescido nas últimas décadas nas mais diversas áreas, seja na indústria ou no dia-a-dia, e é cada vez mais evidente os benefícios que traz. No desporto não é diferente. Cada dia surgem novos desenvolvimentos objetivando a melhoria do desempenho dos praticantes de atividades físicas, possibilitando atingir resultados nunca antes pensados. Além disto, a utilização da tecnologia no desporto permite a obtenção de dados biomecânicos que podem ser utilizados tanto no treinamento quando na melhoria da qualidade de vida dos atletas auxiliando na prevenção de lesões, por exemplo. Deste modo, o presente projeto se aplica na área do desporto, nomeadamente, na modalidade do surfe, onde a ausência de trabalhos científicos ainda é elevada, aliando a tecnologia eletrônica ao desporto para quantificar informações até então desconhecidas. Três fatores básicos de desempenho foram levantados, sendo eles: equilíbrio, posicionamento dos pés e movimentação da prancha de surfe. Estes fatores levaram ao desenvolvimento de um sistema capaz de medi-los dinamicamente através da medição das forças plantares e da rotação da prancha de surfe. Além da medição dos fatores, o sistema é capaz de armazenar os dados adquiridos localmente através de um cartão de memória, para posterior análise; e também enviá-los através de uma comunicação sem fio, permitindo a visualização do centro de pressões plantares; dos ângulos de rotação da prancha de surfe; e da ativação dos sensores; em tempo real. O dispositivo consiste em um sistema eletrônico embarcado composto por um microcontrolador ATMEGA1280; um circuito de aquisição e condicionamento de sinal analógico; uma central inercial; um módulo de comunicação sem fio RN131; e um conjunto de sensores de força Flexiforce. O firmware embarcado foi desenvolvido em linguagem C. O software Matlab foi utilizado para receção de dados e visualização em tempo real. Os testes realizados demostraram que o funcionamento do sistema atende aos requisitos propostos, fornecendo informação acerca do equilíbrio, através do centro de pressões; do posicionamento dos pés, através da distribuição das pressões plantares; e do movimento da prancha nos eixos pitch e roll, através da central inercial. O erro médio de medição de força verificado foi de -0.0012 ± 0.0064 N, enquanto a mínima distância alcançada na transmissão sem fios foi de 100 m. A potência medida do sistema foi de 330 mW.
Resumo:
A exploração do meio subaquático utilizando visão computacional é ainda um processo complexo. Geralmente são utilizados sistemas de visão baseados em visão stereo, no entanto, esta abordagem apresenta limitações, é pouco precisa e é exigente em termos computacionais quando o meio de operação é o subaquático. Estas limitações surgem principalmente em dois cenários de aplicação: quando existe escassez de iluminação e em operações junto a infraestruturas subaquáticas. Consequentemente, a solução reside na utilização de fontes de informação sensorial alternativas ou complementares ao sistema de visão computacional. Neste trabalho propõe-se o desenvolvimento de um sistema de percepção subaquático que combina uma câmara e um projetor laser de um feixe em linha, onde o projetor de luz estruturada _e utilizado como fonte de informação. Em qualquer sistema de visão computacional, e ainda mais relevante em sistemas baseados em triangulação, a sua correta calibração toma um papel fulcral para a qualidade das medidas obtidas com o sistema. A calibração do sistema de visão laser foi dividida em duas etapas. A primeira etapa diz respeito à calibração da câmara, onde são definidos os parâmetros intrínsecos e os parâmetros extrínsecos relativos a este sensor. A segunda etapa define a relação entre a câmara e o laser, sendo esta etapa necessária para a obtenção de imagens tridimensionais. Assim, um dos principais desafios desta dissertação passou por resolver o problema da calibração inerente a este sistema. Desse modo, foi desenvolvida uma ferramenta que requer, pelo menos duas fotos do padrão de xadrez, com perspectivas diferentes. O método proposto foi caracterizado e validado em ambientes secos e subaquáticos. Os resultados obtidos mostram que o sistema _e preciso e os valores de profundidade obtidos apresentam um erro significativamente baixo (inferiores a 1 mm), mesmo com uma base-line (distância entre a centro óptico da câmara e o plano de incidência do laser) reduzida.
Resumo:
Following the deregulation experience of retail electricity markets in most countries, the majority of the new entrants of the liberalized retail market were pure REP (retail electricity providers). These entities were subject to financial risks because of the unexpected price variations, price spikes, volatile loads and the potential for market power exertion by GENCO (generation companies). A REP can manage the market risks by employing the DR (demand response) programs and using its' generation and storage assets at the distribution network to serve the customers. The proposed model suggests how a REP with light physical assets, such as DG (distributed generation) units and ESS (energy storage systems), can survive in a competitive retail market. The paper discusses the effective risk management strategies for the REPs to deal with the uncertainties of the DAM (day-ahead market) and how to hedge the financial losses in the market. A two-stage stochastic programming problem is formulated. It aims to establish the financial incentive-based DR programs and the optimal dispatch of the DG units and ESSs. The uncertainty of the forecasted day-ahead load demand and electricity price is also taken into account with a scenario-based approach. The principal advantage of this model for REPs is reducing the risk of financial losses in DAMs, and the main benefit for the whole system is market power mitigation by virtually increasing the price elasticity of demand and reducing the peak demand.
Resumo:
Dissertação apresentada para obtenção do grau de Doutor em Bioquímica - especialidade Biotecnologia, pela Universidade Nova de Lisboa,Faculdade de Ciências e Tecnologia
Resumo:
A turvação é uma das principais preocupações das empresas de rede de distribuição de água potável. Para se saber a sua origem existem diversos mecanismos, sugeridos em bibliografia, que explicam a formação de depósitos de partículas nas tubagens, que se acumulam em camadas sobrepostas, criando entre si forças de coesão. A turvação pode surgir se o caudal ou a velocidade na tubagem aumentar, por alguma razão, pois um aumento da tensão de corte sobre o depósito, pode superar as forças de coesão levando à sua ressuspensão. Esta explicação é traduzida matematicamente pelo modelo PODDS (Prediction of Discolouration in Drinking Water Distribtuion System). O modelo PODDS foi compilado em EPANET recentemente por uma equipa de investigadores da Universidade de Sheffield e foi utilizado para fazer o estudo num ramal da empresa AdDP - Águas do Douro e Paiva, SA. Os resultados das simulações permitirão prever o caudal mínimo teórico a utilizar no ramal que origina o valor limite de turvação. Foram realizados ensaios de variação do caudal no ramal de Jovim-Ramalde para a calibração do modelo. Os parâmetros obtidos foram: Cmáx igual a 100 NTUm, b e n igual a 1, k é igual -1 NTUm3/N, e por fim, P igual a 0,0001 NTUm3/N.s. Após calibração do modelo realizaram-se simulações com atualização das forças de coesão para conhecer o caudal que provocaria a mobilização das partículas até uma turvação de 4 NTU e concluiu-se que o valor seria de 4,32 m3/s. O tempo necessário para regressar a valores inferiores a 1 NTU também foi determinado e 4 horas e 8 minutos foi o valor alcançado. Por fim realizou-se um estudo da influência da temperatura neste modelo e o resultado mostrou que este parâmetro é pouco influente para a gama de temperaturas considerada.
Resumo:
Oceans - San Diego, 2013
Resumo:
No âmbito da unidade curricular Dissertação/Estágio/Projeto, foi desenvolvido, durante um estágio na Câmara Municipal do Porto, o estudo da eficiência do sistema inteligente de controlo de tráfego implementado na cidade. Este sistema é designado como Sistema Inteligente de Gestão Autónoma - SIGA e tem como base de funcionamento o software de gestão de tráfego GERTRUDE da empresa GERTRUDE SAEM. O sistema de controlo de tráfego encontra-se repartido em 10 zonas interligadas, focadas essencialmente no centro da cidade do Porto. O estudo foi aplicado apenas a uma parte da zona da Constituição, nomeadamente a rua da Constituição, desde a Praça Marquês até à rua Antero de Quental. A eficiência mediu-se pela comparação de duas situações, a circulação e comportamento das correntes de tráfego com o sistema em funcionamento normal e com o sistema desativado. Por sua vez, o indicador utilizado que permitiu avaliar o sistema, foi o nível de serviço obtido pelo atraso médio por veículo em cada ramo de cada interseção. Para determinação do atraso, foram testados diferentes métodos, para se tentar perceber qual aquele que melhor se adequava à situação e que exigia menor número de recursos humanos. À frente serão exaradas algumas conclusões acerca da metodologia de cada um deles e condicionantes que levaram à não utilização de todos os métodos. Depois de aplicadas as metodologias que permitiram determinar o nível de serviço em cada grupo semafórico das diferentes interseções, percebeu-se que existe uma grande diferença na circulação entre as duas situações, sendo que a mais-valia que este sistema apresenta é a coordenação das diferentes interseções que se encontram abrangidas pelas 10 zonas pertencentes ao SIGA.
Resumo:
Thesis submitted to the Instituto Superior de Estatística e Gestão de Informação da Universidade Nova de Lisboa in partial fulfillment of the requirements for the Degree of Doctor of Philosophy in Information Management – Geographic Information Systems
Resumo:
Dissertação para obtenção do Grau de Mestre em Genética Molecular e Biomedicina
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
The four studies in this article introduce a questionnaire to measure Strength of the HRM System (HRMSQ), a multidimensional construct, theoretically developed by Bowen and Ostroff (2004). Strength of the HRM System is a set of process characteristics that lead to effectiveness in conveying signals to employees that allow them to create a shared meaning of desired and appropriate work behaviours. Nine characteristics are suggested, grouped in three features: Distinctiveness, Consistency and Consensus. Study 1 developed and tested a questionnaire in a sample of workers from five different sectors. Study 2 cross-validated the measure in a sample of civil servants in a municipality. These two studies used performance appraisal as the reference HRM practice and led to a short version of the HRMSQ. Study 3 and Study 4 extend the HRMSQ to several common HRM practices. The HRMSQ is tested in two samples, of call center and several private and public organizations‟ workers (study 3). In study 4 the questionnaire is refined and tested with a sample from a hotel chain and finally cross-validated with two other samples, in the insurance and batteries sectors, leading to a longer version of the HRMSQ. Content analysis of several interviews with human resource managers and the Rasch model (1960, 1961, 1980), were used to define and select the indicators of the questionnaire. Convergent, discriminant and predictive validity of the measure are tested. The results of the four studies highlight the complexity of the relationships between the proposed characteristics and support the validity of a parsimonious measure of Strength of the HRM System.
Resumo:
The “CMS Safety Closing Sensors System” (SCSS, or CSS for brevity) is a remote monitoring system design to control safety clearance and tight mechanical movements of parts of the CMS detector, especially during CMS assembly phases. We present the different systems that makes SCSS: its sensor technologies, the readout system, the data acquisition and control software. We also report on calibration and installation details, which determine the resolution and limits of the system. We present as well our experience from the operation of the system and the analysis of the data collected since 2008. Special emphasis is given to study positioning reproducibility during detector assembly and understanding how the magnetic fields influence the detector structure.