987 resultados para Kruskal Wallis test


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. The use of external sources of energy may accelerate the setting rate of glass ionomer cements (GICs) allowing better initial mechanical properties. Aim. To investigate the influence of ultrasound and halogen light on the microleakage and hardness of enamel adjacent to GIC restorations, after artificial caries challenge. Design. Cavities were prepared in 60 primary canines, restored with GIC, and randomly distributed into three groups: control group (CG), light group (LG) - irradiation with a halogen lightcuring unit for 60 s, and ultrasonic group (UG) application of ultrasonic scaler device for 15 s. All specimens were then submitted to a cariogenic challenge in a pH cycling model. Half of sample in each group were immersed in methylene blue for 4 h and sectioned for dye penetration analysis. The remaining specimens were submitted to Knoop cross-sectional microhardness assessments, and mineral changes were calculated for adjacent enamel. Results. Data were compared using Kruskal-Wallis test and two- way ANOVA with 5% significance. Higher dye penetration was observed for the UG (P < 0.01). No significant mineral changes were observed between groups (P = 0.844). Conclusion. The use of halogen light- curing unit does not seem to interfere with the properties of GICs, whereas the use of ultrasound can affect its marginal sealing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The presence of tumor-initiating cells (CD44(+)/CD24(-)) in solid tumors has been reported as a possible cause of cancer metastasis and treatment failure. Nevertheless, little is know about the presence of CD44(+)/CD24(-) cells within the primary tumor and metastasis. The proportion of CD44(+)/CD24(-) cells was analyzed in 40 samples and in 10 lymph node metastases using flow cytometry phenotyping. Anti-human CD326 (EpCam; FITC), antihuman CD227 (MUC-1; FITC), anti-human CD44 (APC), and anti-human CD24 (PE), anti-ABCG2 (PE), and anti-CXCR4 (PeCy7) were used for phenotype analysis. The mean patient age was 60.5 years (range, 33-87 years); mean primary tumor size (pT) was 1.8 cm (0.5-3.5 cm). The Wilcoxon or Kruskal-Wallis test was used for univariate analyses. Logistic regression was used for multivariate analysis. The median percentage of CD44(+)/CD24(-) cells within primary invasive ductal carcinomas (IDC) was 2.7% (range, 0.2-71.2). In lymph node metastases, we observed a mean of 6.1% (range, 0.07-53.7). The percentage of CD44(+)/CD24(-) cells in IDCs was not associated with age, pT, tumor grade and HER2. We observed a significantly enrichment of CD44(+)/CD24(-) and ABCG2(+) cells in ESA(+) cell population in patients with positive lymph nodes (P = 0.02 and P = 0.04, respectively). Our data suggest that metastatic dissemination is associated with an increase in tumorinitiating cells in stage I and II breast cancer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the response of rat subcutaneous tissue to MTA Fillapex® (Angelus), an experimental root canal filling material based on Portland cement and propylene glycol (PCPG), and a zinc oxide, eugenol and iodoform (ZOEI) paste. These materials were placed in polyethylene tubes and implanted into the dorsal connective tissue of Wistar rats for 7 and 15 days. The specimens were stained with hematoxylin and eosin, and evaluated regarding inflammatory reaction parameters by optical microscopy. The intensity of inflammatory response against the sealers was analyzed by two blinded and previously calibrated examiners for all experimental periods (kappa=0.96). The histological evaluation showed that all materials caused a moderate inflammatory reaction at 7 days, which subsided with time. A greater inflammatory reaction was observed at 7 days in the tubes filled with ZOEI paste. Tubes filled with MTA Fillapex presented some giant cells, macrophages and lymphocytes after 7 days. At 15 days, the presence of fibroblasts and collagen fibers was observed indicating normal tissue healing. The tubes filled with PCPG showed similar results to those observed in MTA Fillapex. At 15 days, the inflammatory reaction was almost absent at the tissue, with several collagen fibers indicating normal tissue healing. Data were analyzed by the nonparametric Kruskal-Wallis test (?=0.05). Statistically significant difference (p<0.05) was found only between PCPG at 15 days and ZOEI at 7 days groups. No significant differences were observed among the other groups/periods (p>0.05). MTA Fillapex and Portland cement added with propylene glycol had greater tissue compatibility than the PCPG paste.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The sealers can be in direct contact with the periapical tissues. Thus, these materials must have appropriate physical and biological properties, providing conditions for repair to occur. Objective: The aim of this study was to evaluate the response of rat subcutaneous tissue to endodontics sealers. Material and methods: Three materials comprised the groups: group I – Zinc Oxide, Eugenol and Iodoform paste, group II – Portland cement with propylene glycol, and group III – MTA Fillapex® (Angelus). These materials were placed in polyethylene tubes and implanted into dorsal connective tissue of Wistar rats for seven and 15 days. The specimens were stained with hematoxylin and eosin and evaluated regarding to inflammatory reaction parameters through a light microscope. The data were compared using Kruskal-Wallis test with significance level of 5%. The intensity of inflammatory response against the sealers was analyzed by two blinded and previously calibrated observers for all experimental periods. Results: The histological evaluation showed that all the materials caused a moderated inflammatory reaction at seven days which decreased with time. A greater inflammatory reaction was observed at seven days in group I. The other specimens had significantly less inflammatory cells when compared to this group. Tubes with MTA Fillapex® presented some giant cells, macrophages and lymphocytes after seven days. At 15 days, the presence of fibroblasts and collagen fibers was observed indicating normal tissue healing. The group II showed similar results to those observed in MTA Fillapex® already at seven days. At 15 days the inflammatory reaction presented was almost absent at the tissue, with many collagen fibers indicating normal tissue healing. Statistical analysis showed a significant statistical difference amongst the group I (seven days) and II (15 days) (p < 0.05). In the other groups no (Continue)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The sealers can be in direct contact with the periapical tissues. Thus, these materials must have appropriate physical and biological properties, providing conditions for repair to occur. Objective: The aim of this study was to evaluate the response of rat subcutaneous tissue to endodontics sealers. Material and methods: Three materials comprised the groups: group I – Zinc Oxide, Eugenol and Iodoform paste, group II – Portland cement with propylene glycol, and group III – MTA Fillapex® (Angelus). These materials were placed in polyethylene tubes and implanted into dorsal connective tissue of Wistar rats for seven and 15 days. The specimens were stained with hematoxylin and eosin and evaluated regarding to inflammatory reaction parameters through a light microscope. The data were compared using Kruskal-Wallis test with significance level of 5%. The intensity of inflammatory response against the sealers was analyzed by two blinded and previously calibrated observers for all experimental periods. Results: The histological evaluation showed that all the materials caused a moderated inflammatory reaction at seven days which decreased with time. A greater inflammatory reaction was observed at seven days in group I. The other specimens had significantly less inflammatory cells when compared to this group. Tubes with MTA Fillapex® presented some giant cells, macrophages and lymphocytes after seven days. At 15 days, the presence of fibroblasts and collagen fibers was observed indicating normal tissue healing. The group II showed similar results to those observed in MTA Fillapex® already at seven days. At 15 days the inflammatory reaction presented was almost absent at the tissue, with many collagen fibers indicating normal tissue healing. Statistical analysis showed a significant statistical difference amongst the group I (seven days) and II (15 days) (p < 0.05). In the other groups no significant statistical differences were observed. Conclusion: MTA Fillapex® and Portland cement with propylene glycol were more biocompatible than the other tested cements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the prevalence of the urinary excretion of BKV and JCV in HIV-infected patients without neurological symptoms. METHODS: Urine samples from HIV-infected patients without neurological symptoms were tested for JC virus and BK virus by PCR. Samples were screened for the presence of polyomavirus with sets of primers complementary to the early region of JCV and BKV genome (AgT). The presence of JC virus or BK virus were confirmed by two other PCR assays using sets of primers complementary to the VP1 gene of each virus. Analysis of the data was performed by the Kruskal-Wallis test for numerical data and Pearson or Yates for categorical variables. RESULTS: A total of 75 patients were included in the study. The overall prevalence of polyomavirus DNA urinary shedding was 67/75 (89.3%). Only BKV DNA was detected in 14/75 (18.7%) urine samples, and only JCV DNA was detected in 11/75 (14.7%) samples. Both BKV and JCV DNA were present in 42/75 (56.0%) samples. CONCLUSION: In this study we found high rates of excretion of JCV, BKV, and simultaneous excretion in HIV+ patients. Also these results differ from the others available on the literature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Most studies dealing with the caries preventive action of Nd:YAG laser have been done in permanent teeth and studies on primary teeth are still lacking. The aim of this study was to evaluate in vitro the effect of Nd:YAG laser combined or not with fluoride sources on the acid resistance of primary tooth enamel after artificial caries induction by assessing longitudinal microhardness and demineralization depth. Sixty enamel blocks obtained from the buccal/lingual surface of exfoliated human primary molars were coated with nail polish/wax, leaving only a 9 mm² area exposed on the outer enamel surface, and randomly assigned to 6 groups (n=10) according to the type of treatment: C-control (no treatment); APF: 1.23% acidulated phosphate fluoride gel; FV: 5% fluoride varnish; L: Nd:YAG laser 0.5 W/10 Hz in contact mode; APFL: fluoride gel + laser; FVL: fluoride varnish + laser. After treatment, the specimens were subjected to a des-remineralization cycle for induction of artificial caries lesions. Longitudinal microhardness data (%LMC) were analyzed by the Kruskal-Wallis test and demineralization depth data were analyzed by oneway ANOVA and Fisher’s LSD test (á=0.05). APFL and APF groups presented the lowest percentage of microhardness change (p<0.05). Demineralization depth was smaller in all treated groups compared with the untreated control. In conclusion, Nd:YAG laser combined or not with fluoride gel/varnish was not more effective than fluoride alone to prevent enamel demineralization within the experimental period.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study evaluated the interchangeability of prosthetic components for external hexagon implants by measuring the precision of the implant/abutment (I/A) interface with scanning electron microscopy. Ten implants for each of three brands (SIN, Conexão, Neodent) were tested with their respective abutments (milled CoCr collar rotational and non-rotational) and another of an alternative manufacturer (Microplant) in randomly arranged I/A combinations. The degree of interchangeability between the various brands of components was defined using the original abutment interface gap with its respective implant as the benchmark dimension. Accordingly, when the result for a given component placed on an implant was equal to or smaller then that gap measured when the original component of the same brand as the implant was positioned, interchangeability was considered valid. Data were compared with the Kruskal-Wallis test at 5% significance level. Some degree of misfit was observed in all specimens. Generally, the non-rotational component was more accurate than its rotational counterpart. The latter samples ranged from 0.6-16.9 µm, with a 4.6 µm median; and the former from 0.3-12.9 µm, with a 3.4 µm median. Specimens with the abutment and fixture from Conexão had larger microgap than the original set for SIN and Neodent (p<0.05). Even though the latter systems had similar results with their respective components, their interchanged abutments did not reproduce the original accuracy. The results suggest that the alternative brand abutment would have compatibility with all systems while the other brands were not completely interchangeable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this preliminary study was to verify the antibacterial potential of cetylpyridinium chloride (CPC) in root canals infected by Enterococcus faecalis. Forty human maxillary anterior teeth were prepared and inoculated with E. faecalis for 60 days. The teeth were randomly assigned to the following groups: 1: Root canal preparation (RCP) + 0.1% CPC with positive-pressure irrigation (PPI, Conventional, NaviTip®); 2: RCP + 0.2% CPC PPI; 3: RCP + 2.5% NaOCl PPI; 4: RCP + 2.5% NaOCl with negative-pressure irrigation system (NPI, EndoVac®); 5: Positive control; and 6: Negative control. Four teeth of each experimental group were evaluated by culture and 4 by scanning electron microscopy (SEM). In all teeth, the root canals were dried and filled with 17% EDTA (pH 7.2) for 3 min for smear layer removal. Samples from the infected root canals were collected and immersed in 7 mL of Letheen Broth (LB), followed by incubation at 37°C for 48 h. Bacterial growth was analyzed by turbidity of culture medium and then observed with a UV spectrophotometer. The irrigating solutions were further evaluated for antimicrobial effect by an agar diffusion test.The statistical data were treated by means, standard deviation, Kruskal-Wallis test and analysis of variance. Significance level was set at 5%. The results showed the presence of E. faecalis after root canal sanitization. The number of bacteria decreased after the use of CPC. In the agar diffusion test, CPC induced large microbial inhibition zones, similar to 2% chlorhexidine and large than 2.5% NaOCl. In conclusion, cetylpyridinium chloride showed antibacterial potential in endodontic infection with E. faecalis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: To evaluate oral health-related quality of life of preschool children of Bauru, State of São Paulo, Brazil, and associate it with socioeconomic profile of households. METHODS: The sample consisted of 229 preschool children between 3 and 5 years and the dmft (decayed, missing due to caries, filled teeth) index was adopted for assessment children's dental caries in accordance with the standards recommended by the World Health Organization. Questionnaires were used for evaluation oral health-related quality of life (Early Childhood Oral Health Impact Scale) and socioeconomic profile of parents or guardians of the preschool children. Statistical analysis was performed descriptively by relative and absolute frequencies and by Spearman's correlation and Kruskal-Wallis test (p <0.05). RESULTS: A dmft of 1.65 (± 2.87) and a Sic Index 4.88 (± 3.20) were found, indicating the polarization of dental caries in the studied group. It was verified low influence of oral health on quality of life of the children examined. With respect to socioeconomic classification, 66.38% of families were in the lower middle class. Linear and statistically significant correlation was found between dmft and oral health-related quality of life for the overall score and domains of the questionnaire (p<0.001). CONCLUSIONS: It was found low influence of oral health on quality of life of the preschool children and the assessment of socioeconomic conditions of the children's families may guide practices aiming to reducing inequalities in the distribution of dental caries in the population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To describe and compare three alternative methods for controlling classical friction: Self-ligating brackets (SLB), special brackets (SB) and special elastomeric ligatures (SEB). METHODS: The study compared Damon MX, Smart Clip, In-Ovation and Easy Clip self-ligating bracket systems, the special Synergy brackets and Morelli's twin bracket with special 8-shaped elastomeric ligatures. New and used Morelli brackets with new and used elastomeric ligatures were used as control. All brackets had 0.022 x 0.028-in slots. 0.014-in nickel-titanium and stainless steel 0.019 x 0.025-in wires were tied to first premolar steel brackets using each archwire ligation method and pulled by an Instron machine at a speed of 0.5 mm/minute. Prior to the mechanical tests the absence of binding in the device was ruled out. Statistical analysis consisted of the Kruskal-Wallis test and multiple non-parametric analyses at a 1% significance level. RESULTS: When a 0.014-in archwire was employed, all ligation methods exhibited classical friction forces close to zero, except Morelli brackets with new and old elastomeric ligatures, which displayed 64 and 44 centiNewtons, respectively. When a 0.019 x 0.025-in archwire was employed, all ligation methods exhibited values close to zero, except the In-Ovation brackets, which yielded 45 cN, and the Morelli brackets with new and old elastomeric ligatures, which displayed 82 and 49 centiNewtons, respectively. CONCLUSIONS: Damon MX, Easy Clip, Smart Clip, Synergy bracket systems and 8-shaped ligatures proved to be equally effective alternatives for controlling classical friction using 0.014-in nickel-titanium archwires and 0.019 x 0.025-in steel archwires, while the In-Ovation was efficient with 0.014-in archwires but with 0.019 x 0.025-in archwires it exhibited friction that was similar to conventional brackets with used elastomeric ligatures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dasyatis guttata has been target of artisanal fisheries in the coast of Bahia (Northeast Brazil) mainly by “arraieira” (gillnet) and “grozeira” (bottom long-line), but until now there is no stock assessment study. One of the important data for this knowledge is reliable indices of abundance. The aims of the present work are to: (1) estimate the best predictor for relative abundance (catch-per-unit-of-effort, CPUE), examining whether catch (production – kg) was related to: soak time of the gear, size of the gillnet or number of hooks, applying generalized linear model (GLM); (2) estimate the annual CPUE (kg/hooks and kg/m) averaged by gear; and (3) assess the temporal CPUE variance. Based on monthly sampling between January 2012 and January 2013, 222 landings by grozeira and 76 by arraiaiera were recorded in the two landing sites in Todos os Santos Bay, Bahia. A total of 14,550 kg (average = 44 kg/month) of D. guttata was captured. Models for both gears were highly significant (P < 0.0001). The analysis indicated that the most appropriate variable for CPUE analysis was the size of the gillnet (P < 0.001) and the number of hooks (P < 0.0001). Soak time of the gear was not significant for both gears (P = 0.4). High residual deviance expresses the complexity of the relations between ecosystem factors and other fisheries factors affecting relative abundance, which were not considered in this study. The average CPUE by grozeira was 6.39 kg/100 hooks ± 8.89 and by arraieira, 1.47 kg/100 m ± 1.66 over the year. Kruskal-Wallis test showed effect of the month on the mean grozeira CPUE (P = <0.001), but no effect (P = 0.096) on the mean arraieira CPUE. Grozeira CPUE values were highest in December and March, and lowest between May to August

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ein wichtiger Baustein für den langfristigen Erfolg einer Lebertransplantation ist die Compliance mit der lebenslang einzunehmenden immunsuppressiven Therapie. Im Rahmen der vorliegenden Arbeit wurde erstmals mittels MEMS® die Compliance bei lebertransplantierten Patienten untersucht, deren Transplantation einige Jahre zurücklag. Rekrutiert wurden Patienten, die vor 2, 5, 7 oder 10 Jahren (Gruppe 2 y.p.t., 5 y.p.t., 7 y.p.t., 10 y.p.t.) in der Universitätsmedizin Mainz lebertransplantiert wurden. 39 Patienten nahmen an der prospektiven Anwendungsbeobachtung teil. Die Compliance wurde mittels MEMS® über eine Beobachtungszeit von 6 Monaten erfasst. Bei der MEMS®-Auswertung war zu vermuten, dass 10 Patienten diese nicht wie vorgesehen verwendet hatten. Folglich konnten die mittels MEMS® gemessenen Compliance-Parameter nur für 29 Patienten valide ermittelt werden. Die mittlere Dosing Compliance betrug 81 ± 21 %, wobei die Gruppe 2 y.p.t. mit 86 ± 14 % bessere Werte zu verzeichnen hatte als die Gruppe 5 y.p.t. (75 ± 27 %) und 7 y.p.t. (74 ± 28 %). Die Ergebnisse waren jedoch nicht signifikant unterschiedlich (p=0,335, Kruskal-Wallis-Test). Unter Einbeziehung aller mittels MEMS® gemessenen Compliance-Parameter wurden 19 von 29 Patienten (66 %) als compliant eingestuft. Bei der Analyse der Gesamtcompliance basierend auf den subjektiven Compliance-Messmethoden (Morisky-Fragebogen, MESI-Fragebogen, Selbsteinschätzung), der Arzneimittel-Blutspiegel und der Anzahl an Abstoßungsreaktionen, in der alle 39 Patienten einbezogen werden konnten, wurden 35 Patienten (90 %) als compliant eingestuft. rnIm zweiten Teil der Arbeit wurde die Etablierung und Bewertung eines intersektoralen Pharmazeutischen Betreuungskonzepts für lebertransplantierte Patienten untersucht. Erstmals wurden anhand eines entwickelten schnittstellenübergreifenden, integrierten Betreuungskonzepts niedergelassene Apotheker in die Pharmazeutische Betreuung lebertransplantierter Patienten eingebunden. 20 Patienten wurden rekrutiert und während ihres stationären Aufenthaltes nach Transplantation pharmazeutisch betreut. Die Betreuung umfasste eine intensive Patientenschulung mit drei bis vier Gesprächen durch einen Krankenhausapotheker. Während des stationären Aufenthaltes wurden arzneimittelbezogene Probleme erkannt, gelöst und dokumentiert. Bei Entlassung stellte der Krankenhausapotheker einen Medikationsplan für den Hausarzt sowie für den niedergelassenen Apotheker aus und führte mit den Patienten ein ausführliches Entlassungsgespräch. Darüber hinaus wurden den Patienten Arzneimitteleinnahmepläne und eine Patienteninformation über ihr immunsuppressives Arzneimittel übergeben. 15 Patienten konnten daraufhin ambulant von niedergelassenen Apothekern pharmazeutisch weiterbetreut werden. Das kooperierende pharmazeutische Personal wurde durch ein eigens für die Studie erstelltes Manual zur Pharmazeutischen Betreuung lebertransplantierter Patienten geschult und unterstützt. Die niedergelassenen Apotheker sollten die Patienten in ihrer Arzneimitteltherapie begleiten, indem Beratungsgespräche geführt und arzneimittelbezogene Probleme erkannt und gelöst wurden. Die Nutzeffekte der intensiven Pharmazeutischen Betreuung konnte anhand verschiedener Erhebungsinstrumente dargelegt werden. Im Ergebnis resultierte eine hohe Zufriedenheit der Patienten und Apotheker mit dem Betreuungskonzept, die mittels Selbstbeurteilungsfragebögen ermittelt wurde. Die Compliance der Patienten wurde anhand des Morisky- und MESI-Fragebogens, der Selbsteinschätzung der Patienten, Blutspiegelbestimmungen sowie der Einschätzung durch den niedergelassenen Apotheker bestimmt. 86 % der Patienten wurden als compliant eingeordnet. Die Kenntnisse der Patienten über ihre immunsuppressive Therapie, welche anhand von Interviews erfragt wurden, lagen auf einem sehr hohen Niveau. Abschließend kann festgestellt werden, dass die Pharmazeutische Betreuung lebertransplantierter Patienten in den niedergelassenen Apotheken durchführbar ist. Anhand der Dokumentationsprotokolle lässt sich allerdings nur sehr schwer beurteilen, in welchem Maße die Betreuung tatsächlich erfolgte. Das tatsächliche vorliegen einer mangelnden Betreuung oder aber eine lückenhafte Dokumentation der Betreuungsleistung war nicht zu differenzieren. Ein limitierender Faktor für die intensivierte Betreuung ist sicherlich der erhebliche Aufwand für nur einen Patienten mit einem seltenen Krankheitsbild. Das Erkennen und Lösen von 48 ABP durch den Krankenhausapotheker und 32 ABP durch die niedergelassenen Apotheker, d. h. insgesamt 4,5 ABP pro Patient zeigt, dass die Pharmazeutische Betreuung einen wichtigen Beitrag für eine qualitätsgesicherte Arzneimitteltherapie leistet. Die intersektorale Pharmazeutische Betreuung stellt eine wesentliche Hilfe und Unterstützung der Patienten im sicheren Umgang mit ihrer Arzneimitteltherapie dar.rn

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Compliance lebertransplantierter Patienten mit der immunsuppressiven Therapie ist unerlässlich für den lang-fristigen Erfolg der Lebertransplantation. Aus Non-Compliance mit der immunsuppressiven Therapie können Abstoßungsreaktionen, Organverlust oder sogar Tod resultieren. Hauptziel der vorliegenden Studie war die erstmalige Evaluation der Compliance bei Einnahme von Prograf® (zweimal tägliche Einnahme von Tacrolimus) im Vergleich zur Einnahme von Advagraf® (einmal tägliche Einnahme von Tacrolimus). Von Interesse war außerdem die Fragestellung, ob sich die Compliance bezüglich der immunsuppressiven Therapie mit dem Zeitabstand zur Transplantation verändert. rnDie Compliancemessung wurde offen mittels MEMS® (Aardex Ltd., Schweiz) durchgeführt, der Patient war also über die Compliancekontrolle informiert. Mittels MEMS® konnten Datum und Uhrzeit der Dosisentnahme dokumentiert und damit zuverlässig das gesamte Compliancemuster über im Durchschnitt 176 Tage mit der zweimal täglichen Einnahme und 188 Tage mit der einmal täglichen Einnahme pro Patient erfasst werden. 65 Patienten mit dem Basisimmunsuppressivum Prograf® wurden in die prospektive, nicht-interventionelle Studie eingeschlossen und nach Per Protokoll-Analyse konnten die Daten von 63 in Mainz lebertransplantierten Patienten ausgewertet werden (Prograf®: Gruppe 1: 15 Patienten (Pat.), Gruppe 2: 23 Pat., Gruppe 3: 22 Pat., Drop-outs: 3 Pat.; Advagraf®: Gruppe 1: 16 Pat., Gruppe 2: 23 Pat., Gruppe 3: 23 Pat., Drop-outs: 1 Pat.). Die Dosing Compliance (DC), definiert als Prozent der Tage, an denen der MEMS®-Behälter korrekt geöffnet und die Dosis höchstwahrscheinlich korrekt eingenommen wurde, war der primäre Zielparameter. Weitere Methoden der Compliancemessung, wie der Pill Count, mehrere Fragebögen (Selbsteinschätzung, Patientenwissen-, Morisky-, MESI-, HADS-, SF-36- und Patientenzufriedenheit-Fragebogen) sowie die Blutspiegelmessung wurden eingesetzt, um die Compliance der Patienten umfassend charakterisieren zu können. rnDer Median der DC mit der zweimal täglichen Einnahme betrug 97% bei Pat. > 6 m.p.t. < 2 y.p.t., 97% bei Pat. > 2 y.p.t. < 5 y.p.t. und 98% bei Pat. > 5 y.p.t. (p=0,931; Kruskal-Wallis-Test). Der Median der DC von Tacroli-mus bei einmal täglicher Einnahme (Advagraf®) betrug 99% bei Pat. > 6 m.p.t. < 2 y.p.t., 98% bei Pat. > 2 y.p.t. < 5 y.p.t. und 97% bei Pat. > 5 y.p.t. (p=0,158; Kruskal-Wallis-Test). Insgesamt zeigten die Patienten während des gesamten Beobachtungszeitraums von 12 Monaten eine gute Compliance für die Einnahme ihres Immun-suppressivums. Die Timing Compliance (TiC)-raten lagen auf einem niedrigeren Niveau als die Dosing- und Taking Compliance (TC)-raten. Die Complianceraten der drei Subgruppen unterschieden sich nicht signifikant. Die Patienten mit dem geringsten Abstand zur Transplantation zeigten bei beinahe allen Messmethoden die höchste Compliance im Gegensatz zur etwas geringeren Compliance der Patienten mit größerem Abstand zur Transplantation. Die während der Advagraf®-Phase mittels MEMS® gemessenen DC-, TC- und TiC-raten fielen höher aus als bei Einnahme von Prograf® (p(DC)=0,003; p(TC)=0,077; p(TiC)=0,003; Wilcoxon Vorzeichen-Rang-Test). Dieses Ergebnis untermauert die in anderen Indikationen gefundene Complianceverbesserung durch die einmal tägliche Arzneimittelgabe im Vergleich zur zweimal täglichen Gabe. Die Auswertung der Drug Holidays ergab für die Advagraf®-Phase hingegen niedrigere Complianceraten als für die Prograf®-Phase. Dieses Ergebnis ist auf die Definition des Drug Holidays (keine Arzneimitteleinnahme über 48 h) zurück zu führen. Die Chance Advagraf® einmal pro Tag zu vergessen ist doppelt so hoch, als Prograf® dreimal aufeinander fol-gend zu vergessen. Mit einer verhältnismäßigeren Definition von Drug Holidays (Einnahmepause von 72 Stun-den bei einmal täglicher Einnahme von Advagraf® entsprechend drei ausgelassenen Dosen von Prograf®) ist die Compliancerate 81%. Die Ergebnisse des Pill Counts waren sowohl bei Einnahme von Prograf® als auch von Advagraf® mit der jeweils gemessenen TC vergleichbar, was die Zuverlässigkeit der Messergebnisse bes-tätigt. rnDie zusätzlich eingesetzten Methoden verifizierten das Ergebnis der höheren Compliance mit der einmal tägli-chen Einnahme. Die während der Advagraf®-Phase beantworteten Fragebögen zeigten einen Trend zu besserer Compliance und Lebensqualität. Lediglich die Ergebnisse des MESI-Fragebogens und der Blutspiegelmessungen wichen sowohl während der Prograf®- als auch während der Advagraf®-Phase stark von den Ergebnis-sen der anderen Methoden ab. rnUnter Einbeziehung aller mittels MEMS® und Pill Count objektiv gemessenen Complianceparameter konnten während der Prograf®-Einnahme 54 von 60 Pat. (90%) und während der Advagraf®-Phase 59 von 62 Pat. (95%) als compliant eingestuft werden. Aufgrund subjektiver Compliancemessungen waren 49 von 58 Pat. (84%) während der Prograf®- und 54 von 59 Pat. (92%) während der Advagraf®-Phase als compliant einzustufen. Es wurde beobachtet, dass die zeitlich korrekte Einnahme der Morgendosis einfacher und bei Einmalgabe zu bevorzugen ist. Die wochentagsbezogene Auswertung ergab erwartungsgemäß, dass am Wochenende (Samstag und Sonntag) am häufigsten Dosen ausgelassen wurden. rnDie Umstellung von Prograf® auf Advagraf® stellte kein Problem dar. Beinahe alle Patienten waren dankbar und zufrieden mit der Reduzierung der Dosierungsfrequenz und der größeren Unabhängigkeit durch die entfallene abendliche Einnahme. Der positive Einfluss der geringeren Dosierungshäufigkeit auf die Langzeitcompliance der Patienten, ist ein hinreichender Grund die Entwicklung von Formulierungen zur einmal täglichen Ein-nahme für weitere Immunsuppressiva zu fordern. Insbesondere bei den häufig eingesetzten Kombinationstherapien von Immunsuppressiva würde der Effekt der Complianceverbesserung noch verstärkt werden, wenn alle eingesetzten Immunsuppressiva zur einmal täglichen Gabe geeignet wären.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated (1) the micromorphology by scanning electron microscopy (SEM) and (2) the adhesive performance by microtensile bond strength (μTBS) of diamond bur-treated dentin compared to Er:YAG laser-treated dentin of human primary teeth. (1) For qualitative SEM evaluation, dentin of 18 second primary molars (n = 3/method) was treated with either diamond bur as a control (group 1a: 40 μm diamond bur only (clinical situation); group 1b: grinding + 40 μm diamond bur) or with Er:YAG laser (group 2a (clinical situation, manufacturer's settings): 200 mJ/25 Hz (5 W) + 100 mJ/35 Hz (3.5 W) laser only; group 2b (experimental setting "high"): grinding + 400 mJ/20 Hz (8 W); group 2c (manufacturer's setting "finishing"): grinding + 100 mJ/35 Hz (3.5 W); group 2d (experimental setting "low"): grinding + 50 mJ/35 Hz (1.75 W)). (2) For evaluation of adhesive performance, 64 second primary molars were divided into four groups and treated as described for group 1b and groups 2b/c/d (n = 16/method), and μTBS of Clearfil SE/Clearfil Majesty Esthetic to dentin was measured. The SEM micrographs were qualitatively analyzed. The μTBS values were compared with a Kruskal-Wallis test. The significance level was set at α = 0.05. SEM micrographs showed the typical micromorphologies with a smear layer for the diamond bur groups and open dentin tubules for all laser-treated groups. However, in group 2d, the laser beam had insufficiently irradiated the dentin area, rendering the underlying ground surface partly visible. There were no statistically significant differences between μTBS values of the four groups (p = 0.394). This suggests that Er:YAG laser treatment of dentin of primary molars provides bond strengths similar to those obtained following diamond bur treatment.