663 resultados para KW-2228
Resumo:
The epidemiology of temporomandibular disorders varies widely in the literature. The aim of this study was to determine the prevalence of TMD in dental students of the Federal University of Rio Grande do Norte assessed by different indexes. The sample consisted of 101 individuals selected by a randomized process, whose general outline was systematic sampling. For evaluation of the signs and symptoms of TMD, an anamnestic index, Fonseca s protocol, and two clinical indexes, the RDC/TMD (Research Diagnostic Criteria for Temporomandibular Disorders), or standard index, and the Helkimo s Clinical Dysfunction Index were applied. Data were analyzed using the chi-square test and kappa, besides verifying the sensitivity and specificity (5% significance). The diagnosis of TMD by different indexes showed a variation in the prevalence between 72.3% (Helkimo s Clinical index), 64.4% (Fonseca s anamnestic index) and 35.6% (RDC/TMD). There was no statistical difference between the sexes for the RDC/TMD, although this difference was found for Fonseca s and Helkimo s indexes (p<0.05). The most frequent type of TMD were joint disorders (Groups II and III), and the subtypes disc displacement with reduction (17.8%) and arthralgia (15.8%). Most individuals showed a mild TMD (45.5%) for both indexes, Fonseca and Helkimo. When comparing the types of diagnoses, RDC/TMD with Fonseca and Helkimo, low agreement was found (k=0.17 and k= 0.35, respectively). A moderate correlation between the severity of TMD was obtained (kw= 0.53) for Fonseca s protocol and Helkimo s index. High sensitivity and low specificity were seen for both diagnoses compared to standard, resulting in excessive false positives. Within the limitations of the study, it was concluded that the prevalence of TMD can vary widely, depending on the index used for its diagnosis
Resumo:
A implantação de microcentrais hidrelétricas é uma das alternativas para suprir com energia comunidades pequenas e isoladas, situadas normalmente na área rural. O aproveitamento de potenciais hidráulicos de pequeno porte é uma alternativa cada vez mais viável devido não só à falta de recursos financeiros para os grandes empreendimentos, mas também pelo imenso potencial de geração em centrais de pequeno porte, que pouco tem sido aproveitado. O objetivo deste trabalho foi de apresentar uma metodologia simples de engenharia para estimar o custo das Bombas Funcionando como Turbinas (BFTs) utilizadas em microcentrais hidrelétricas, que possam ser usadas em estudos preliminares de novos aproveitamentos hidrelétricos, sem uma investigação detalhada dos lugares onde se pretende implantar. Os custos foram obtidos consultando-se diretamente os fabricantes de equipamentos e o mercado da praça de Ponta Grossa - PR. Os resultados mostraram que, para as microcentrais hidrelétricas, sempre que os custos constituírem o aspecto dominante, e para potências até 50 kW, a opção por Bombas Funcionando como Turbinas (BFTs) deve ser considerada em lugar das turbinas hidráulicas.
Resumo:
O trabalho comparou o desempenho de um trator agrícola 4x2 TDA de 89 kW (121cv) em função do tipo de pneus (radial, diagonal e de baixa pressão), a condição de lastragem (com e sem água nos pneus) e quatro velocidades [V1 (1,84km h-1), V2 (3,18km h-1, V3 (4,57km h-1), V4 (5,04km h-1)]. O experimento foi realizado na UNESP-Jaboticabal-SP, em condição de preparo do solo com escarificador de sete hastes a 30cm de profundidade. Os pneus foram do tipo R1, com as seguintes características: [radial (dianteiros-14.9 R 26; traseiros-620/75 R 30) diagonal (dianteiros-14.9-26, traseiros-23.1-30) e BPAF (dianteiros-500/60-26.5; traseiros-700/55-34)]. O delineamento experimental foi blocos casualizados, em esquema fatorial 3x2x4, com 24 tratamentos e três repetições. Os resultados evidenciaram vantagens para o trator equipado com pneus radiais.
Resumo:
A method for studying the technical and economic feasibility of absorption refrigeration systems in compact cogenerators is presented. The system studied consists of an internal combustion engine, an electric generator and a heat exchanger to recover residual heat from the refrigeration water and exhaust gases. As an application, a computer program simulates the cogeneration system in a building which already has 75 kW of installed electric power. The maximum electric and refrigeration demands are 45 kW and 76 kW respectively. This study simulates the system performance, utilizing diesel oil, sugar cane alcohol and natural gas as possible fuels. (C) 1997 Elsevier B.V. Ltd.
Resumo:
This paper presents a methodology for the study of a molten carbonate fuel cell co-generation system. This system is applied to a dairy industry of medium size that typically demands 2100 kW of electricity, 8500 kg/h of saturated steam (P = 1.08 MPa) and 2725 kW of cold water production. Depending on the associated recuperation equipment, the co-generation system permits the recovery of waste heat, which can be used for the production of steam, hot and cold water, hot and cold air. In this study, a comparison is made between two configurations of fuel cell co-generation systems (FCCS). The plant performance has been evaluated on the basis of fuel utilisation efficiency and each system component evaluated on the basis of second law efficiency. The energy analysis presented shows a fuel utilisation efficiency of about 87% and exergy analysis shows that the irreversibilities in the combustion chamber of the plant are significant. Further, the payback period estimated for the fuel cell investment between US$ 1000 and US$ 1500/k-W is about 3 and 6 years, respectively. (C) 2002 Elsevier B.V. B.V. All rights reserved.
Resumo:
This paper presents an improved analysis of a novel Programmable Power-factor-corrected-Based Hybrid Multipulse Power Rectifier (PFC-HMPR) for utility interface of power electronic converters. The proposed hybrid multipulse rectifier is composed of an ordinary three-phase six-pulse diode-bridge rectifier (Graetz bridge) with a parallel connection of single-phase switched converters in each three-phase rectifier leg. In this paper, the authors present a complete discussion about the controlled rectifiers' power contribution and also a complete analysis concerning the total harmonic distortion of current that can be achieved when the proposed converter operates as a conventional 12-pulse rectifier. The mathematical analysis presented in this paper corroborate, with detailed equations, the experimental results of two 6-kW prototypes implemented in a laboratory.
Resumo:
PbO-Bi2O3-Ga2O3 glasses doped with different concentrations of Yb3+ are presented. The spectroscopic properties and laser parameters are calculated and a comparison between different results obtained when calculating the Yb3+ emission cross-section with the reciprocity method and with the Fuchtbauer-Ladenburg formula is presented. The behavior of the near-infrared luminescence is described theoretically by a rate equation and compared with the experimental results. This host doped with Yb3+ is a promising material for laser action at 1019 nm, with properties similar to other known glasses used as active laser media; the emission cross-section of 1.1 x 10(-20) cm(2), the high absorption cross-section (of 2.0 x 10(-20) cm(2)) and a minimum pump intensity of 2.4 kW/cm(2) are interesting properties for short pulse generation. (C) 2005 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This work presents the design and procedure of a DC-to-AC converter using a ZVS Commutation Cell developed by Barbi and Martins (1991) and applied to the family of DC-to-DC PWM converters. Firstly, we show the cell applied to buck converter. The stages of operation and the main current and voltage equations of the resonant devices are presented. Next, we adapt the converter to the regenerative operation mode. Hence, the full bridge converter at low frequency operation is conected on the DC-to-DC stage (at high frequency) output ends (Seixas, 1993). Commutation of zero voltage for all switches, PWM at constant frequency and neither overvoltage nor additional current stress are observed by digital simulation. The design example and experimental results obtained by prototype rated at 275 V, 1 kW and 40 kHz are also presented.
Resumo:
This paper presents the analysis of a dc-ac converter using a zero-voltage-switching (ZVS) commutation cell. First, we show the cell applied to the buck converter. The stages of operation are presented along with the main current and voltage equations. Next, we adapt the converter to the regenerative-operation mode. Hence, the full-bridge converter at low-frequency operation is connected in the dc-dc output stage (at high frequency). The main switches commute at zero voltage. The converter operated at constant frequency with pulse-width modulation (PWM), and neither overvoltage nor additional current stress was observed by digital simulation. A design example and experimental results obtained by prototype, rated at 275 V and 1 kW, are also presented. © 1997 IEEE.
Resumo:
The undergraduates in Nursing have been subject of studies on psychic problems, as alterations in behavior interfere in their learning. The aim of this research was to identify and measure the most frequent depression symptoms among the students using Beck's Depression Inventory. Socio-demographic information about the interviewees was also collected. Ninety-nine (99) students (81.82%) participated. The socio-demographic data show women's predominance (96.97%) in average with 20 years of age; 95.96% not originally from Botucatu and family monthly income of 5 to 10 minimum wages. In the total of the sampling, 41.41% presented a certain degree of depression varying from mild to severe. The most frequent symptoms were self-accusation, irritability and fatigue. The investigation shows the need of programs that follow the students during their academic formation.
Resumo:
In this paper, a methodology for the study of a fuel cell cogeneration system and applied to a university campus is developed. The cogeneration system consists of a molten carbonate fuel cell associated to an absorption refrigeration system. The electrical and cold-water demands of the campus are about 1,000 kW and 1,840 kW (at 7°C), respectively. The energy, exergy and economic analyses are presented. This system uses natural gas as the fuel and operates on electric parity. In conclusion, the fuel cell cogeneration system may have an excellent opportunity to strengthen the decentralized energy production in the Brazilian tertiary sector.