987 resultados para Intravascular ultrasound imaging


Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: Imaging of the crystalline lens and intraocular lens is becoming increasingly more important to optimize the refractive outcome of cataract surgery, to detect and manage complications and to ascertain advanced intraocular lens performance. This review examines recent advances in anterior segment imaging. RECENT FINDINGS: The main techniques used for imaging the anterior segment are slit-lamp biomicroscopy, ultrasound biomicroscopy, scheimpflug imaging, phakometry, optical coherence tomography and magnetic resonance imaging. They have principally been applied to the assessment of intraocular lens centration, tilt, position relative to the iris and movement with ciliary body contraction. SUMMARY: Despite the advances in anterior chamber imaging technology, there is still the need for a clinical, high-resolution, true anatomical, noninvasive technique to image behind the peripheral iris. © 2007 Lippincott Williams & Wilkins, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Opto-acoustic imaging (OAI) shows particular promise for in-vivo biomedical diagnostics. Its applications include cardiovascular, gastrointestinal and urogenital systems imaging. Opto-acoustic endoscopy (OAE) allows the imaging of body parts through cavities permitting entry. The critical parameter is the physical size of the device, allowing compatibility with current technology, while governing flexibility of the distal end of the endoscope based on the needs of the sensor. Polymer optical fibre (POF) presents a novel approach for endoscopic applications and has been positively discussed and compared in existing publications. A great advantage can be obtained for endoscopy due to a small size and array potential to provide discrete imaging speed improvements. Optical fibre exhibits numerous advantages over conventional piezo-electric transducers, such as immunity from electromagnetic interference and a higher resolution at small sizes. Furthermore, micro structured polymer optical fibres offer over 12 times the sensitivity of silica fibre. We present a polymer fibre Bragg grating ultrasound detector with a core diameter of 125 microns. We discuss the ultrasonic signals received and draw conclusions on the opportunities and challenges of applying this technology in biomedical applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A ecografia é o exame de primeira linha na identificação e caraterização de tumores anexiais. Foram descritos diversos métodos de diagnóstico diferencial incluindo a avaliação subjetiva do observador, índices descritivos simples e índices matematicamente desenvolvidos como modelos de regressão logística, continuando a avaliação subjectiva por examinador diferenciado a ser o melhor método de discriminação entre tumores malignos e benignos. No entanto, devido à subjectividade inerente a esta avaliação tornouse necessário estabelecer uma nomenclatura padronizada e uma classificação que facilitasse a comunicação de resultados e respectivas recomendações de vigilância. O objetivo deste artigo é resumir e comparar diferentes métodos de avaliação e classificação de tumores anexiais, nomeadamente os modelos do grupo International Ovary Tumor Analysis (IOTA) e a classificação Gynecologic Imaging Report and Data System (GI-RADS), em termos de desempenho diagnóstico e utilidade na prática clínica.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Urachal carcinoma is a rare neoplasm, which accounts for only 0.5–2% of bladder malignancies, and arises from a remnant of the fetal genitourinary tract. A 46-year-old woman presented with a history of pelvic pain and frequent daytime urination. Ultrasound (US), computed tomography (CT), and magnetic resonance (MR) demonstrated a supravesical heterogeneous mass with calcifications. The patient underwent a partial cystectomy with en-bloc resection of the mass and histopathological examination revealed the diagnosis of urachal adenocarcinoma. Urachal carcinomas are usually associated with poor prognosis and early diagnosis is fundamental. CT and MR are useful to correctly diagnose and preoperatively staging.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes a novel algorithm for tracking the motion of the urethra from trans-perineal ultrasound. Our work is based on the structure-from-motion paradigm and therefore handles well structures with ill-defined and partially missing boundaries. The proposed approach is particularly well-suited for video sequences of low resolution and variable levels of blurriness introduced by anatomical motion of variable speed. Our tracking method identifies feature points on a frame by frame basis using the SURF detector/descriptor. Inter-frame correspondence is achieved using nearest-neighbor matching in the feature space. The motion is estimated using a non-linear bi-quadratic model, which adequately describes the deformable motion of the urethra. Experimental results are promising and show that our algorithm performs well when compared to manual tracking.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Prostate cancer is the most common non-dermatological cancer amongst men in the developed world. The current definitive diagnosis is core needle biopsy guided by transrectal ultrasound. However, this method suffers from low sensitivity and specificity in detecting cancer. Recently, a new ultrasound based tissue typing approach has been proposed, known as temporal enhanced ultrasound (TeUS). In this approach, a set of temporal ultrasound frames is collected from a stationary tissue location without any intentional mechanical excitation. The main aim of this thesis is to implement a deep learning-based solution for prostate cancer detection and grading using TeUS data. In the proposed solution, convolutional neural networks are trained to extract high-level features from time domain TeUS data in temporally and spatially adjacent frames in nine in vivo prostatectomy cases. This approach avoids information loss due to feature extraction and also improves cancer detection rate. The output likelihoods of two TeUS arrangements are then combined to form our novel decision support system. This deep learning-based approach results in the area under the receiver operating characteristic curve (AUC) of 0.80 and 0.73 for prostate cancer detection and grading, respectively, in leave-one-patient-out cross-validation. Recently, multi-parametric magnetic resonance imaging (mp-MRI) has been utilized to improve detection rate of aggressive prostate cancer. In this thesis, for the first time, we present the fusion of mp-MRI and TeUS for characterization of prostate cancer to compensates the deficiencies of each image modalities and improve cancer detection rate. The results obtained using TeUS are fused with those attained using consolidated mp-MRI maps from multiple MR modalities and cancer delineations on those by multiple clinicians. The proposed fusion approach yields the AUC of 0.86 in prostate cancer detection. The outcomes of this thesis emphasize the viable potential of TeUS as a tissue typing method. Employing this ultrasound-based intervention, which is non-invasive and inexpensive, can be a valuable and practical addition to enhance the current prostate cancer detection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The background of this study is to assess the accuracy of lung ultrasound (LUS) to diagnose interstitial lung disease (ILD) in Sjögren’s syndrome (Sjs), in patients who have any alterations in pulmonary function tests (PFT) or respiratory symptoms. LUS was correlated with chest tomography (hrCT), considering it as the imaging gold standard technique to diagnose ILD. This is a pilot, multicenter, cross-sectional, and consecutive-case study. The inclusion criteria are ≥18 years old, Signs and symptoms: according to ACEG 2002 criteria, respiratory symptoms (dyspnea, cough), or any alterations in PFR. LUS was done following the International Consensus Conference on Lung Ultrasound protocol for interstitial syndrome (B pattern). Of the 50 patients in follow-up, 13 (26%) met the inclusion criteria. All were women with age 63.62 years (range 39–88). 78.6% of the cases had primary Sjs (SLE, RA, n = 2). The intra-rater reliability k is 1, according to Gwet’s Ac1 and GI index (probability to concordance—e(K)—, by Cohen, of 0.52). LUS has a sensitivity of 1 (95% CI 0.398–1.0), specificity of 0.89 (95% CI 0.518–0.997), and a positive probability reason of 9.00 (95% CI 7.1–11.3) to detect ILD. The correlation of Pearson is r = 0.84 (p < 0.001). To check the accuracy of LUS to diagnose ILD, a completely bilateral criterion of yes/no for interstitial pattern was chosen, AUC reaches significance, 0.94 (0.07) (95% CI 0.81–1.0, p = 0.014). LUS reaches an excellent correlation to hrCT in Sjs affected with ILD, and might be a useful technique in daily clinical practice for the assessment of pulmonary disease in the sicca syndrome. © 2016 SIMI

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes a novel algorithm for tracking the motion of the urethra from trans-perineal ultrasound. Our work is based on the structure-from-motion paradigm and therefore handles well structures with ill-defined and partially missing boundaries. The proposed approach is particularly well-suited for video sequences of low resolution and variable levels of blurriness introduced by anatomical motion of variable speed. Our tracking method identifies feature points on a frame by frame basis using the SURF detector/descriptor. Inter-frame correspondence is achieved using nearest-neighbor matching in the feature space. The motion is estimated using a non-linear bi-quadratic model, which adequately describes the deformable motion of the urethra. Experimental results are promising and show that our algorithm performs well when compared to manual tracking.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To investigate the use of intravascular optical coherence tomography (IVOCT) for carotid artery stenting (CAS) procedures in patients with atherosclerotic stenosis. Examine possible markers that might identify the onset of new cerebral ischemic lesions on MRI. Specifically, attention was drawn to the morphological features of the used dual layer stent, which could be underestimated during traditional CAS procedures. Secondary goals are to compare the safety and efficacy of different CAS techniques and the accuracy of the vessel analysis software’s on pre-operative CTA examination used to quantify ICA stenosis with the gold standard IVOCT. Material and Methods: Ten patients underwent CAS procedure with flow-arrest technique and IVOCT evaluations prior to and following stent deployment, while five matched patients underwent CAS procedure with distal embolic protection device (EPD) technique. All patients underwent 24-hours 3T MRI examination to check for ischemic lesions; all patients were treated with the same dual-layer stent. Results: Patients with new ischemic lesions demonstrated peculiar stent configuration in the distal end, and a strong Spearman’s rank order correlation was found among the volume of new DWI lesions and the stent configuration in its distal end (Rs: 0.81; p <0.001). No statistically significant differences were observed in the total burden of new ischemic lesions for each technique. The vessel analysis software's on CTA comparison demonstrated a higher diagnostic accuracy in the degree of ICA stenosis compared to the gold standard of IVOCT of the specialized software (ROC curve = 0.63; p = 0.06) compared to the general software (ROC curve = 0.57, p = 0.31). Conclusions: Study’s results support the use of IVOCT to allow recognition of potential features that can predict the onset of new cerebral ischemic lesions. Additionally, IVOCT made it possible to evaluate specialized software's increased accuracy in the pre-operative evaluation of ICA atherosclerotic stenosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Split-plot design (SPD) and near-infrared chemical imaging were used to study the homogeneity of the drug paracetamol loaded in films and prepared from mixtures of the biocompatible polymers hydroxypropyl methylcellulose, polyvinylpyrrolidone, and polyethyleneglycol. The study was split into two parts: a partial least-squares (PLS) model was developed for a pixel-to-pixel quantification of the drug loaded into films. Afterwards, a SPD was developed to study the influence of the polymeric composition of films and the two process conditions related to their preparation (percentage of the drug in the formulations and curing temperature) on the homogeneity of the drug dispersed in the polymeric matrix. Chemical images of each formulation of the SPD were obtained by pixel-to-pixel predictions of the drug using the PLS model of the first part, and macropixel analyses were performed for each image to obtain the y-responses (homogeneity parameter). The design was modeled using PLS regression, allowing only the most relevant factors to remain in the final model. The interpretation of the SPD was enhanced by utilizing the orthogonal PLS algorithm, where the y-orthogonal variations in the design were separated from the y-correlated variation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to test the feasibility and reproducibility of diffusion-weighted magnetic resonance imaging (DW-MRI) evaluations of the fetal brains in cases of twin-twin transfusion syndrome (TTTS). From May 2011 to June 2012, 24 patients with severe TTTS underwent MRI scans for evaluation of the fetal brains. Datasets were analyzed offline on axial DW images and apparent diffusion coefficient (ADC) maps by two radiologists. The subjective evaluation was described as the absence or presence of water diffusion restriction. The objective evaluation was performed by the placement of 20-mm(2) circular regions of interest on the DW image and ADC maps. Subjective interobserver agreement was assessed by the kappa correlation coefficient. Objective intraobserver and interobserver agreements were assessed by proportionate Bland-Altman tests. Seventy-four DW-MRI scans were performed. Sixty of them (81.1%) were considered to be of good quality. Agreement between the radiologists was 100% for the absence or presence of diffusion restriction of water. For both intraobserver and interobserver agreement of ADC measurements, proportionate Bland-Altman tests showed average percentage differences of less than 1.5% and 95% CI of less than 18% for all sites evaluated. Our data demonstrate that DW-MRI evaluation of the fetal brain in TTTS is feasible and reproducible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To analyze the main factors that influence bone mass in children and teenagers assessed by quantitative ultrasound (QUS) of the phalanges. A systematic literature review was performed according to the PRISMA method with searches in databases Pubmed/Medline, SciELO and Bireme for the period 2001-2012, in English and Portuguese languages, using the keywords: children, teenagers, adolescent, ultrasound finger phalanges, quantitative ultrasound of phalanges, phalangeal quantitative ultrasound. 21 articles were included. Girls had, in QUS, Amplitude Dependent Speed of Sound (AD-SoS) values higher than boys during pubertal development. The values of the parameters of QUS of the phalanges and dual-energy X-ray Absorptiometry (DXA) increased with the increase of the maturational stage. Anthropometric variables such as age, weight, height, body mass index (BMI), lean mass showed positive correlations with the values of QUS of the phalanges. Physical activity has also been shown to be positively associated with increased bone mass. Factors such as ethnicity, genetics, caloric intake and socioeconomic profile have not yet shown a conclusive relationship and need a larger number of studies. QUS of the phalanges is a method used to evaluate the progressive acquisition of bone mass during growth and maturation of individuals in school phase, by monitoring changes that occur with increasing age and pubertal stage. There were mainly positive influences in variables of sex, maturity, height, weight and BMI, with similar data when compared to the gold standard method, the DXA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present essay is illustrated with magnetic resonance images obtained at the authors' institution over the past 15 years and discusses the main imaging findings of intraventricular tumor-like lesions (ependymoma, pilocytic astrocytoma, central neurocytoma, ganglioglioma, choroid plexus papilloma, primitive neuroectodermal tumors, meningioma, epidermoid tumor). Such lesions represent a subgroup of intracranial lesions with unique characteristics and some image patterns that may facilitate the differential diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present essay is illustrated with magnetic resonance images obtained at the authors' institution over the past 15 years and discusses the main imaging findings of intraventricular tumor-like lesions (colloid cyst, oligodendroglioma, astroblastoma, lipoma, cavernoma) and of inflammatory/infectious lesions (neurocysticercosis and an atypical presentation of neurohistoplasmosis). Such lesions represent a subgroup of intracranial lesions with unique characteristics and some imaging patterns that may facilitate the differential diagnosis.