911 resultados para Interação 3D


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare 3 different flow targeted magnetization preparation strategies for coronary MR angiography (cMRA), which allow selective visualization of the vessel lumen. MATERIAL AND METHODS: The right coronary artery of 10 healthy subjects was investigated on a 1.5 Tesla MR system (Gyroscan ACS-NT, Philips Healthcare, Best, NL). A navigator-gated and ECG-triggered 3D radial steady-state free-precession (SSFP) cMRA sequence with 3 different magnetization preparation schemes was performed referred to as projection SSFP (selective labeling of the aorta, subtraction of 2 data sets), LoReIn SSFP (double-inversion preparation, selective labeling of the aorta, 1 data set), and inflow SSFP (inversion preparation, selective labeling of the coronary artery, 1 data set). Signal-to-noise ratio (SNR) of the coronary artery and aorta, contrast-to-noise ratio (CNR) between the coronary artery and epicardial fat, vessel length and vessel sharpness were analyzed. RESULTS: All cMRA sequences were successfully obtained in all subjects. Both projection SSFP and LoReIn SSFP allowed for selective visualization of the coronary arteries with excellent background suppression. Scan time was doubled in projection SSFP because of the need for subtraction of 2 data sets. In inflow SSFP, background suppression was limited to the tissue included in the inversion volume. Projection SSFP (SNR(coro): 25.6 +/- 12.1; SNR(ao): 26.1 +/- 16.8; CNR(coro-fat): 22.0 +/- 11.7) and inflow SSFP (SNR(coro): 27.9 +/- 5.4; SNR(ao): 37.4 +/- 9.2; CNR(coro-fat): 24.9 +/- 4.8) yielded significantly increased SNR and CNR compared with LoReIn SSFP (SNR(coro): 12.3 +/- 5.4; SNR(ao): 11.8 +/- 5.8; CNR(coro-fat): 9.8 +/- 5.5; P < 0.05 for both). Longest visible vessel length was found with projection SSFP (79.5 mm +/- 18.9; P < 0.05 vs. LoReIn) whereas vessel sharpness was best in inflow SSFP (68.2% +/- 4.5%; P < 0.05 vs. LoReIn). Consistently good image quality was achieved using inflow SSFP likely because of the simple planning procedure and short scanning time. CONCLUSION: Three flow targeted cMRA approaches are presented, which provide selective visualization of the coronary vessel lumen and in addition blood flow information without the need of contrast agent administration. Inflow SSFP yielded highest SNR, CNR and vessel sharpness and may prove useful as a fast and efficient approach for assessing proximal and mid vessel coronary blood flow, whereas requiring less planning skills than projection SSFP or LoReIn SSFP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Com o intuito de avaliar a submissão de consultas em língua natural, especificamente em português, a máquinas de busca na Web, e contrastar com as consultas por palavras-chave, realizou-se um experimento com alunos, professores e funcionários de uma universidade brasileira. Particularmente, analisaram-se as consultas para verificar se os usuários expressavam bem seus objetivos em palavras-chave; como expressariam seus objetivos em língua natural, caso esta possibilidade fosse oferecida; se as consultas em língua natural forneciam informações que pudessem facilitar a recuperação de informação. O pedido de colaboração foi enviado a 440 pessoas de um instituto de computação da universidade. Foram obtidas 63 consultas, correspondentes a 42 objetivos. Observou-se que, para o item a, na maioria dos casos (71,43%), as consultas por meio de palavras-chave não trazem todas as informações declaradas importantes no objetivo; para o item b as consultas foram feitas por meio de perguntas (71,87%), afirmações (18,75%) e ordens (9,37%); e, para o item c todas as perguntas diretas deixavam claro o objetivo da consulta já com a primeira palavra da frase, ou com as duas ou três primeiras, com exceção das iniciadas pela palavra "qual".

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most sedimentary modelling programs developed in recent years focus on either terrigenous or carbonate marine sedimentation. Nevertheless, only a few programs have attempted to consider mixed terrigenous-carbonate sedimentation, and most of these are two-dimensional, which is a major restriction since geological processes take place in 3D. This paper presents the basic concepts of a new 3D mathematical forward simulation model for clastic sediments, which was developed from SIMSAFADIM, a previous 3D carbonate sedimentation model. The new extended model, SIMSAFADIM-CLASTIC, simulates processes of autochthonous marine carbonate production and accumulation, together with clastic transport and sedimentation in three dimensions of both carbonate and terrigenous sediments. Other models and modelling strategies may also provide realistic and efficient tools for prediction of stratigraphic architecture and facies distribution of sedimentary deposits. However, SIMSAFADIM-CLASTIC becomes an innovative model that attempts to simulate different sediment types using a process-based approach, therefore being a useful tool for 3D prediction of stratigraphic architecture and facies distribution in sedimentary basins. This model is applied to the neogene Vallès-Penedès half-graben (western Mediterranean, NE Spain) to show the capacity of the program when applied to a realistic geologic situation involving interactions between terrigenous clastics and carbonate sediments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors compared radial steady-state free precession (SSFP) coronary magnetic resonance (MR) angiography, cartesian k-space sampling SSFP coronary MR angiography, and gradient-echo coronary MR angiography in 16 healthy adults and four pilot study patients. Standard gradient-echo MR imaging with a T2 preparatory pulse and cartesian k-space sampling was the reference technique. Image quality was compared by using subjective motion artifact level and objective contrast-to-noise ratio and vessel sharpness. Radial SSFP, compared with cartesian SSFP and gradient-echo MR angiography, resulted in reduced motion artifacts and superior vessel sharpness. Cartesian SSFP resulted in increased motion artifacts (P <.05). Contrast-to-noise ratio with radial SSFP was lower than that with cartesian SSFP and similar to that with the reference technique. Radial SSFP coronary MR angiography appears preferable because of improved definition of vessel borders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Discorre sobre as interações, a aprendizagem e as bibliotecas na área da saúde, tendo como referencial teórico a filosofia da multiplicidade de Deleuze e Guattari. Apresenta um levantamento da literatura recente brasileira sobre usuários de informação em bibliotecas universitárias, sistematizando os objetivos, as metodologias e os resultados alcançados em cada estudo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En este trabajo se presentan los resultados derivados de la interpretacón de 320 estaciones gravimétricas realizadas sobre el diapiro de Cardona con el objetivo de obtener información sobre su geometría tridimensional. Para obtener una distribución tridimensional de la masa salina que explique las anomalías observadas se ha aplicado un método iterativo de ajustes sucesivos basado en un algoritmo de inversión automática. Esta metodología ha mostrado ser muy rápida, fácil de usar y con suficiente poder de resolución para perfilar no sólo la geometría del cuerpo salino, sino también la de estructuras similares. El diapiro salino de Cardona presenta un mínimo gravimétrico relacionado con el anticlinal de Pins-Cardona que se prolonga hacia el SW. El análisis cualitativo de la anomalía residual permite apreciar que el diapiro muestra una cierta vergencia hacia sur con un flanco sureste subvertical y un flanco noroeste con pendientes más suaves.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During conventional x-ray coronary angiography, multiple projections of the coronary arteries are acquired to define coronary anatomy precisely. Due to time constraints, coronary magnetic resonance angiography (MRA) usually provides only one or two views of the major coronary vessels. A coronary MRA approach that allowed for reconstruction of arbitrary isotropic orientations might therefore be desirable. The purpose of the study was to develop a three-dimensional (3D) coronary MRA technique with isotropic image resolution in a relatively short scanning time that allows for reconstruction of arbitrary views of the coronary arteries without constraints given by anisotropic voxel size. Eight healthy adult subjects were examined using a real-time navigator-gated and corrected free-breathing interleaved echoplanar (TFE-EPI) 3D-MRA sequence. Two 3D datasets were acquired for the left and right coronary systems in each subject, one with anisotropic (1.0 x 1.5 x 3.0 mm, 10 slices) and one with "near" isotropic (1.0 x 1.5 x 1.0 mm, 30 slices) image resolution. All other imaging parameters were maintained. In all cases, the entire left main (LM) and extensive portions of the left anterior descending (LAD) and the right coronary artery (RCA) were visualized. Objective assessment of coronary vessel sharpness was similar (41% +/- 5% vs. 42% +/- 5%; P = NS) between in-plane and through-plane views with "isotropic" voxel size but differed (32% +/- 7% vs. 23% +/- 4%; P < 0.001) with nonisotropic voxel size. In reconstructed views oriented in the through-plane direction, the vessel border was 86% more defined (P < 0.01) for isotropic compared with anisotropic images. A smaller (30%; P < 0.001) improvement was seen for in-plane reconstructions. Vessel diameter measurements were view independent (2.81 +/- 0.45 mm vs. 2.66 +/- 0.52 mm; P = NS) for isotropic, but differed (2.71 +/- 0.51 mm vs. 3.30 +/- 0.38 mm; P < 0.001) between anisotropic views. Average scanning time was 2:31 +/- 0:57 minutes for anisotropic and 7:11 +/- 3:02 minutes for isotropic image resolution (P < 0.001). We present a new approach for "near" isotropic 3D coronary artery imaging, which allows for reconstruction of arbitrary views of the coronary arteries. The good delineation of the coronary arteries in all views suggests that isotropic 3D coronary MRA might be a preferred technique for the assessment of coronary disease, although at the expense of prolonged scan times. Comparative studies with conventional x-ray angiography are needed to investigate the clinical utility of the isotropic strategy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A cultura da alfafa (Medicago sativa) é importante para a produção animal, por sua alta qualidade nutritiva, alto potencial de produção e sucesso na fixação de nitrogênio, através da simbiose com o Rhizobium meliloti, dispensando o uso de adubação nitrogenada. Neste trabalho objetivou-se selecionar estirpes comerciais de R. meliloti (SEMIA-116, SEMIA-134 e SEMIA-135) em relação às cultivares de alfafa Flórida 77, Pioneer 5929, CUF 101 e Crioula, e avaliar os fungicidas Iprodione e Thiram em tratamento de semente e solo na cultivar Crioula. Não houve interação entre as estirpes de R. meliloti e as cultivares de alfafa quanto à produção de matéria seca, e as plantas infestadas com a SEMIA-116 apresentaram maior número de nódulos. Houve interações entre os diferentes tipos e doses de fungicidas e as estirpes de R. meliloti testadas. A estirpe SEMIA-116 apresentou superioridade, representada pela maior produção de biomassa e número de nódulos. Pelos resultados obtidos, não se recomenda a inoculação da estirpe SEMIA-135, quando em associação com o fungicida Iprodione, em solo ou semente.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the dramatic increase in the volume of experimental results in every domain of life sciences, assembling pertinent data and combining information from different fields has become a challenge. Information is dispersed over numerous specialized databases and is presented in many different formats. Rapid access to experiment-based information about well-characterized proteins helps predict the function of uncharacterized proteins identified by large-scale sequencing. In this context, universal knowledgebases play essential roles in providing access to data from complementary types of experiments and serving as hubs with cross-references to many specialized databases. This review outlines how the value of experimental data is optimized by combining high-quality protein sequences with complementary experimental results, including information derived from protein 3D-structures, using as an example the UniProt knowledgebase (UniProtKB) and the tools and links provided on its website ( http://www.uniprot.org/ ). It also evokes precautions that are necessary for successful predictions and extrapolations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For radiotherapy treatment planning of retinoblastoma inchildhood, Computed Tomography (CT) represents thestandard method for tumor volume delineation, despitesome inherent limitations. CT scan is very useful inproviding information on physical density for dosecalculation and morphological volumetric information butpresents a low sensitivity in assessing the tumorviability. On the other hand, 3D ultrasound (US) allows ahigh accurate definition of the tumor volume thanks toits high spatial resolution but it is not currentlyintegrated in the treatment planning but used only fordiagnosis and follow-up. Our ultimate goal is anautomatic segmentation of gross tumor volume (GTV) in the3D US, the segmentation of the organs at risk (OAR) inthe CT and the registration of both. In this paper, wepresent some preliminary results in this direction. Wepresent 3D active contour-based segmentation of the eyeball and the lens in CT images; the presented approachincorporates the prior knowledge of the anatomy by usinga 3D geometrical eye model. The automated segmentationresults are validated by comparing with manualsegmentations. Then, for the fusion of 3D CT and USimages, we present two approaches: (i) landmark-basedtransformation, and (ii) object-based transformation thatmakes use of eye ball contour information on CT and USimages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A cardiac-triggered, free-breathing, 3D balanced FFE projection renal MR angiography (MRA) technique with a 2D pencil beam aortic labeling pulse for selective aortic spin tagging was developed. For respiratory motion artifact suppression during free breathing, a prospective real-time navigator was implemented for renal MRA. Images obtained with the new approach were compared with standard contrast-enhanced (CE) 3D breath-hold MRA in seven swine. Signal properties and vessel visualization were analyzed. With the presented technique, high-resolution, high-contrast renal projection MRA with superior vessel length visualization (including a greater visible number of distal branches of the renal arteries) compared to standard breath-hold CE-MRA was obtained. The present results warrant clinical studies in patients with renal artery disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: In the present study, the impact of the two different fat suppression techniques was investigated for free breathing 3D spiral coronary magnetic resonance angiography (MRA). As the coronary arteries are embedded in epicardial fat and are adjacent to myocardial tissue, magnetization preparation such as T(2)-preparation and fat suppression is essential for coronary discrimination. MATERIALS AND METHODS: Fat-signal suppression in three-dimensional (3D) thin- slab coronary MRA based on a spiral k-space data acquisition can either be achieved by signal pre-saturation using a spectrally selective inversion recovery pre-pulse or by spectral-spatial excitation. In the present study, the performance of the two different approaches was studied in healthy subjects. RESULTS: No significant objective or subjective difference was found between the two fat suppression approaches. CONCLUSION: Spectral pre-saturation seems preferred for coronary MRA applications due to the ease of implementation and the shorter cardiac acquisition window.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar o efeito de Zn e P, em solução nutritiva, na absorção desses elementos pela alface (Lactuca sativa L.) e na produtividade dessa hortaliça. O delineamento experimental utilizado foi o de blocos casualizados, com os tratamentos dispostos num esquema fatorial 3 x 3, com três repetições. Os tratamentos foram constituídos de três níveis de Zn: baixo, normal e alto, correspondentes a 0,0, 1,5 e 6,0 miM L-1, e de três níveis de P: baixo, normal e alto, correspondentes a 0,01, 1,5 e 6,0 mM L-1, utilizando-se como fontes o ZnSO4.7H2O e o KH2PO4, respectivamente. Aos 26 dias após o transplante (DAT), a área foliar e a produção de matéria seca da parte aérea não foram influenciadas pelos tratamentos. Aos 52 DAT, a área foliar, o número de folhas e a matéria seca da parte aérea não foram influenciadas pela adição de Zn à solução quando o nível de P foi baixo. Porém, quando os níveis de P foram normal e alto, os níveis normal e alto de Zn propiciaram maiores valores de área foliar, de número de folhas, e de produção de matéria seca da parte aérea. Os teores de P nas folhas comerciais, em cada nível de Zn, foram semelhantes quando houve adição das doses normal e alta de P à solução. O maior teor de P foi o do caule, seguido do das raízes, e, por último, do das folhas comerciais. Os teores de Zn na matéria seca das folhas comerciais, nos caules e nas raízes, aumentaram com adição de Zn à solução, em todos os níveis de fósforo.