970 resultados para Indirect measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zero correlation between measurement error and model error has been assumed in existing panel data models dealing specifically with measurement error. We extend this literature and propose a simple model where one regressor is mismeasured, allowing the measurement error to correlate with model error. Zero correlation between measurement error and model error is a special case in our model where correlated measurement error equals zero. We ask two research questions. First, we wonder if the correlated measurement error can be identified in the context of panel data. Second, we wonder if classical instrumental variables in panel data need to be adjusted when correlation between measurement error and model error cannot be ignored. Under some regularity conditions the answer is yes to both questions. We then propose a two-step estimation corresponding to the two questions. The first step estimates correlated measurement error from a reverse regression; and the second step estimates usual coefficients of interest using adjusted instruments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to design and validate the measurement of ankle kinetics (force, moment, and power) during consecutive gait cycles and in the field using an ambulatory system. An ambulatory system consisting of plantar pressure insole and inertial sensors (3D gyroscopes and 3D accelerometers) on foot and shank was used. To test this system, 12 patients and 10 healthy elderly subjects wore shoes embedding this system and walked many times across a gait lab including a force-plate surrounded by seven cameras considered as the reference system. Then, the participants walked two 50-meter trials where only the ambulatory system was used. Ankle force components and sagittal moment of ankle measured by ambulatory system showed correlation coefficient (R) and normalized RMS error (NRMSE) of more than 0.94 and less than 13% in comparison with the references system for both patients and healthy subjects. Transverse moment of ankle and ankle power showed R>0.85 and NRMSE<23%. These parameters also showed high repeatability (CMC>0.7). In contrast, the ankle coronal moment of ankle demonstrated high error and lower repeatability. Except for ankle coronal moment, the kinetic features obtained by the ambulatory system could distinguish the patients with ankle osteoarthritis from healthy subjects when measured in 50-meter trials. The proposed ambulatory system can be easily accessible in most clinics and could assess main ankle kinetics quantities with acceptable error and repeatability for clinical evaluations. This system is therefore suggested for field measurement in clinical applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypoglycaemia is a major cause of neonatal morbidity and may induce long-term developmental sequelae. Clinical signs of hypoglycaemia in neonatal infants are unspecific or even absent, and therefore, precise and accurate methods for the assessment of glycaemia are needed. Glycaemia measurement in newborns has some particularities like a very low limit of normal glucose concentration compared to adults and a large range of normal haematocrit values. Many bedside point-of-care testing (POCT) systems are available, but literature about their accuracy in newborn infants is scarce and not very convincing. In this retrospective study, we identified over a 1-year study period 1,324 paired glycaemia results, one obtained at bedside with one of three different POCT systems (Elite? XL, Ascensia? Contour? and ABL 735) and the other in the central laboratory of the hospital with the hexokinase reference method. All three POCT systems tended to overestimate glycaemia values, and none of them fulfilled the ISO 15197 accuracy criteria. The Elite XL appeared to be more appropriate than Contour to detect hypoglycaemia, however with a low specificity. Contour additionally showed an important inaccuracy with increasing haematocrit. The bench analyzer ABL 735 was the most accurate of the three tested POCT systems. Both of the tested handheld glucometers have important drawbacks in their use as screening tools for hypoglycaemia in newborn infants. ABL 735 could be a valuable alternative, but the blood volume needed is more than 15 times higher than for handheld glucometers. Before daily use in the newborn population, careful clinical evaluation of each new POCT system for glucose measurement is of utmost importance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comparative study of the indirect haemagglutination (IHA), immunofluorescence (IFAT) and immunoenzymatic (ELISA) tests was carried out to determine the prevalence of Toxoplasma gondii antibodies in goats. One hundred seventy-four serum samples were obtained from four goat herds from the region of Uberlândia, State of Minas Gerais. The distribution of the animals, according to their origin, was as follow: 71 from herd I; 39 from herd II; 37 from herd III; and 27 from herd IV. Serum samples were analyzed by IHA, IFAT and ELISA, considering the reactivity of the serum samples at dilution ≥ 1:64 as cut off titer for the three tests. A global seroprevalence of 18.4% was observed, with significantly higher positivity rate in the herd II (66.7%) and older animals (> 36 months). A high and significant positive correlation was found between the titers obtained by the IHA versus IFAT, IHA versus ELISA, and ELISA versus IFAT. Therefore, it can be concluded that the three analyzed tests have shown to be highly concordant and appropriate for epidemiological surveys of Toxoplasma infection in goats. Although the seroprevalence of T. gondii infection in goats is relatively low in this region as compared to other regions of the country, adequate management might be useful and essential to control the infection in the goat herds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gim & Kim (1998) proposed a generalization of Jeong (1982, 1984) reinterpretation of the Hawkins-Simon condition for macroeconomic stability to off-diagonal matrix elements. This generalization is conceptually relevant for it offers a complementary view of interindustry linkages beyond final or net output influence. The extension is completely similar to the 'total flow' idea introduced by Szyrmer (1992) or the 'output-to-output' multiplier of Miller & Blair (2009). However the practical implementation of Gim & Kim is actually faulty since it confuses the appropriate order of output normalization. We provide a new and elementary solution for the correct formalization using standard interindustry accounting concepts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the effects of recent advances in magnetic resonance imaging (MRI) radiofrequency (RF) coil and parallel imaging technology on brain volume measurement consistency. MATERIALS AND METHODS: In all, 103 whole-brain MRI volumes were acquired at a clinical 3T MRI, equipped with a 12- and 32-channel head coil, using the T1-weighted protocol as employed in the Alzheimer's Disease Neuroimaging Initiative study with parallel imaging accelerations ranging from 1 to 5. An experienced reader performed qualitative ratings of the images. For quantitative analysis, differences in composite width (CW, a measure of image similarity) and boundary shift integral (BSI, a measure of whole-brain atrophy) were calculated. RESULTS: Intra- and intersession comparisons of CW and BSI measures from scans with equal acceleration demonstrated excellent scan-rescan accuracy, even at the highest acceleration applied. Pairs-of-scans acquired with different accelerations exhibited poor scan-rescan consistency only when differences in the acceleration factor were maximized. A change in the coil hardware between compared scans was found to bias the BSI measure. CONCLUSION: The most important findings are that the accelerated acquisitions appear to be compatible with the assessment of high-quality quantitative information and that for highest scan-rescan accuracy in serial scans the acquisition protocol should be kept as consistent as possible over time. J. Magn. Reson. Imaging 2012;36:1234-1240. ©2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Urinary human chorionic gonadotropin (hCG) concentration is routinely measured in all anti-doping laboratories to exclude the misuse of recombinant or urinary hCG preparations. In this study, extended validation of two commercial immunoassays for hCG measurements in urine was performed. Both tests were initially designed for hCG determination in human serum/plasma. Methods: Access (R) and Elecsys (R) 1010 are two automated immunoanalysers for central laboratories. The limits of detection and quantification, as well as intra-laboratory and inter-technique correlation, precision, and accuracy, were determined. Stability studies of hCG in urine following freezing and thawing cycles (n = 3) as well as storage conditions at room temperature, 4 degrees C and 20 degrees C, were performed. Results: Statistical evaluation of hCG concentrations in male urine samples (n = 2429) measured with the Elecsys (R) 1010 system enabled us to draw a skewed frequency histogram and establish a far outside value equal to 2.3 IU/L. This decision limit corresponds to the concentration at which a sportsman will be considered positive for hCG. Intra-assay precision for the Access (R) analyser was less than 4.0 A, whereas the inter-assay precision was closer to 4.5 % (concentrations of the official external controls contained between 5.5 and 195.0 IU/L). Intra and inter-assay precision for the Elecsys (R) 1010 analyser was slightly better. A good inter-technique correlation was obtained when measuring various urine samples (male and female). No urinary hCG loss was observed after two freeze/thaw cycles. On the other hand, time and inappropriate storage conditions, such as temperatures above 10 degrees C for more than 5 days, can deteriorate urinary hCG. Conclusions: Both analysers showed acceptable performances and are suitable for screening urine for anti-doping analyses. Each laboratory should validate and establish its own reference values because hCG concentrations measured in urine can be different from one immunoassay to another. The time delay between urine collection and analysis should be reduced as much as possible, and urine samples should be transported in optimal conditions to avoid a loss of hCG immunoreactivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To investigate the relationships between diet composition, body composition, and macronutrient oxidation at rest in obese and non-obese children. DESIGN: Cross-sectional study on fat intake, adiposity and postabsorptive macronutrients oxidation rates. SUBJECTS: 82 prepubertal (age: 9.1 +/- 1.1 y) children, 30 obese (FM = 32.6 +/- 6.1%) and 52 non-obese (FM = 15.6 +/- 5.1%). MEASUREMENTS: Subcutaneous skinfold thickness for body composition, diet history for energy and nutrient intake, indirect calorimetry for resting metabolic rate (RMR) and RQ measurement. RESULTS: Energy intake (EI) was comparable in obese and non-obese children. Adjusted for RMR by ANCOVA, using RMR as the covariate, EI was significantly lower in obese than in non-obese children indicating either a blunted physical activity or a systematic underestimation of EI. Protein and carbohydrate intakes expressed as a percentage of total energy intake (%EI) were not significantly different in the two groups. Lipid intake (%EI) was slightly but significantly higher in the obese than in the non-obese group either unadjusted or adjusted for RMR by ANCOVA. The postabsorptive RQ was significantly lower in obese than in non-obese children. In the total group, %FM was weakly but significantly correlated to lipid intake (%EI). CONCLUSION: Obese prepubertal children have a higher relative fat intake than non-obese children and their FM is associated with this factor. The lower postabsorptive RQ of obese children may indicate a compensatory mechanism to achieve fat equilibrium by enhanced fat oxidation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Irish Government in March 2008 set a target to identify measure and reduce the Administrative Burden (AB) of domestic regulation for businesses by 25% by the end of 2012 – on foot of a European Council invitation to all member states in March 2007. As part of a cross-Government process led by the Business Regulation Unit of the Department of Jobs, Enterprise and Innovation (DJEI), the Department of Health carried out a measurement exercise in 2012 on the main Information Obligations placed on business by legislation in the areas of Food, Nursing Homes and Pharmacy sectors.The AB baseline measurement for those information obligations is described in this report. Click here to download PDF 322KB  

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to evaluate the Organon Teknika MB/BacT system used for testing indirect susceptibility to the alternative drugs ofloxacin (OFLO), amikacin (AMI), and rifabutin (RIF), and to the usual drugs of standard treatment regimes such as rifampin (RMP), isoniazid (INH), pyrazinamide (PZA), streptomycin (SM), ethambutol (EMB), and ethionamide (ETH), cultures of clinical specimens from 117 patients with pulmonary tuberculosis under multidrug-resistant investigation, admitted sequentially for examination from 2001 to 2002, were studied. Fifty of the Mycobacterium tuberculosis cultures were inoculated into the gold-standard BACTEC 460 TB (Becton Dickinson) for studying resistance to AMI, RIF, and OFLO, and the remaining 67 were inoculated into Lowenstein Jensen (LJ) medium (the gold standard currently used in Brazil) for studying resistance to RMP, INH, PZA, SM, EMB, and ETH. We observed 100% sensitivity for AMI (80.8-100), RIF (80.8-100), and OFLO (78.1-100); and 100% specificity for AMI (85.4-100), RIF (85.4-100), and OFLO (86.7-100) compared to the BACTEC system. Comparing the results obtained in LJ we observed 100% sensitivity for RMP (80-100), followed by INH - 95% (81.8-99.1), EMB - 94.7% (71.9-99.7), and 100% specificity for all drugs tested except for PZA - 98.3 (89.5-99.9) at 95% confidence interval. The results showed a high level of accuracy and demonstrated that the fully automated, non-radiometric MB/BacT system is indicated for routine use in susceptibility testing in public health laboratories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Twenty-four-hour energy expenditure (EE), daily and sleeping EE, and the energy cost of a standardized treadmill exercise were assessed in a respiration chamber in 41 young pregnant Gambian women at 12 (n = 11), 24 (n = 15), and 36 (n = 15) wk of gestation and compared with 13 nonpregnant nonlactating (NPNL) control women. The rate of 24-h EE was significantly higher (P less than 0.001) at 36 wk gestation (8443 +/- 243 kJ/d) than in the NPNL group (6971 +/- 172 kJ/d) or at 12 and 24 wk (7088 +/- 222 and 7188 +/- 192 kJ/d, respectively). Per unit body weight, no more differences in 24-h EE, daily and sleeping EE, or energy cost of walking were observed between pregnant and NPNL women. There was no statistical difference in the 24-h respiratory quotient among the groups. We conclude that the state of pregnancy in Gambian women induces a progressive rise in 24-h EE, which becomes significant in the third trimester and is proportional to body weight.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on advanced dual-wavelength digital holographic microscopy (DHM) methods, enabling single-acquisition real-time micron-range measurements while maintaining single-wavelength interferometric resolution in the nanometer regime. In top of the unique real-time capability of our technique, it is shown that axial resolution can be further increased compared to single-wavelength operation thanks to the uncorrelated nature of both recorded wavefronts. It is experimentally demonstrated that DHM topographic investigation within 3 decades measurement range can be achieved with our arrangement, opening new applications possibilities for this interferometric technique. ©2008 COPYRIGHT SPIE