860 resultados para Hip Kinematics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context. The Sun shows abundance anomalies relative to most solar twins. If the abundance peculiarities are due to the formation of inner rocky planets, that would mean that only a small fraction of solar type stars may host terrestrial planets. Aims. In this work we study HIP 56948, the best solar twin known to date, to determine with an unparalleled precision how similar it is to the Sun in its physical properties, chemical composition and planet architecture. We explore whether the abundances anomalies may be due to pollution from stellar ejecta or to terrestrial planet formation. Methods. We perform a differential abundance analysis (both in LTE and NLTE) using high resolution (R similar to 100 000) high S/N (600-650) Keck HIRES spectra of the Sun (as reflected from the asteroid Ceres) and HIP 56948. We use precise radial velocity data from the McDonald and Keck observatories to search for planets around this star. Results. We achieve a precision of sigma less than or similar to 0.003 dex for several elements. Including errors in stellar parameters the total uncertainty is as low as sigma similar or equal to 0.005 dex (1%), which is unprecedented in elemental abundance studies. The similarities between HIP 56948 and the Sun are astonishing. HIP 56948 is only 17 +/- 7 K hotter than the Sun, and log g, [Fe/H] and microturbulence velocity are only +0.02 +/- 0.02 dex, +0.02 +/- 0.01 dex and +0.01 +/- 0.01 km s(-1) higher than solar, respectively. Our precise stellar parameters and a differential isochrone analysis shows that HIP 56948 has a mass of 1.02 +/- 0.02 M-circle dot and that it is similar to 1 Gyr younger than the Sun, as constrained by isochrones, chromospheric activity, Li and rotation. Both stars show a chemical abundance pattern that differs from most solar twins, but the refractory elements (those with condensation temperature T-cond greater than or similar to 1000 K) are slightly (similar to 0.01 dex) more depleted in the Sun than in HIP 56948. The trend with T-cond in differential abundances (twins -HIP 56948) can be reproduced very well by adding similar to 3 M-circle plus of a mix of Earth and meteoritic material, to the convection zone of HIP 56948. The element-to-element scatter of the Earth/meteoritic mix for the case of hypothetical rocky planets around HIP 56948 is only 0.0047 dex. From our radial velocity monitoring we find no indications of giant planets interior to or within the habitable zone of HIP 56948. Conclusions. We conclude that HIP 56948 is an excellent candidate to host a planetary system like our own, including the possible presence of inner terrestrial planets. Its striking similarity to the Sun and its mature age makes HIP 56948 a prime target in the quest for other Earths and SETI endeavors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osteoporotic hip fractures (OHF) are not limited to elderly; however, studies in non-elderly are scarce. Thus, the aim of this study was to evaluate co-morbidities in non-elderly patients with OHF in a Community Teaching Hospital. All hospitalizations due to OHF during a 3-year period in a Community Teaching Hospital were retrospectively evaluated for co-morbidities, and patients 18-64 years old were compared with those a parts per thousand yen65 years old. Of all hospitalizations, 232 (0.73%) were due to hip fractures, and 120/232 (51.7%) patients had OHF. The comparison of the 13 (10.8%) OHF patients < 65 years old (47.3 +/- A 9.7 years) with 107 (89.2%) a parts per thousand yen65 years old (80.4 +/- A 7.7 years) revealed a male predominance (61.5 vs. 27.1%, P = 0.022) and a distinct ethnic distribution with a lower proportion of Caucasians in the former (61.5 vs. 86.9%, P = 0.033). Moreover, non-elderly OHF patients had higher frequencies of insulin-dependent DM (38.5 vs. 3.7%, P = 0.001) and alcoholism (38.5 vs. 4.7%, P = 0.001) than aged patients. In contrast, rates of age-related co-morbidities such as stroke (7.7 vs. 18.7%, P = 0.461), heart failure (23.1 vs. 14.0%, P = 0.411), and dementia (7.7 vs. 15.9%, P = 0.689) were comparable in both groups. Logistic regression analysis demonstrated that insulin-dependent DM (OR = 25.4, 95% CI = 4.7-136.8, P < 0.001) and alcoholism (OR = 20.3, 95% CI = 3.9-103.3, P < 0.001) remained as independent risk factors for OHF in non-elderly patients. Osteoporosis is an important cause of HF in Community Hospital. Non-elderly patients with OHF have a peculiar demographic profile and associated co-morbidities. These findings reinforce the need of early osteoporosis diagnosis and rigorous fracture prevention in patients with DM and alcoholism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents further results from our spectroscopic study of the globular cluster (GC) system of the group elliptical NGC 3923. From observations made with the GMOS instrument on the Gemini South Telescope, an additional 50 GC and ultra-compact dwarf (UCD) candidates have been spectroscopically confirmed as members of the NGC 3923 system. When the recessional velocities of these GCs are combined with the 29 GC velocities reported previously, a total sample of 79 GC/UCD velocities is produced. This sample extends to over 6 arcmin (>6 R-e similar to 30 kpc) from the centre of NGC 3923 and is used to study the dynamics of the GC system and the dark matter content of NGC 3923. It is found that the GC system of NGC 3923 displays no appreciable rotation, and that the projected velocity dispersion is constant with radius within the uncertainties. The velocity dispersion profiles of the integrated light and GC system of NGC 3923 are indistinguishable over the region in which they overlap. We find some evidence that the diffuse light and GCs of NGC 3923 have radially biased orbits within similar to 130 arcsec. The application of axisymmetric orbit-based models to the GC and integrated light velocity dispersion profiles demonstrates that a significant increase in the mass-to-light ratio (from M/L-V = 8 to 26) at large galactocentric radii is required to explain this observation. We therefore confirm the presence of a dark matter halo in NGC 3923. We find that dark matter comprises 17.5(-4.5)(+7.3) per cent of the mass within 1 R-e, 41.2(-10.6)(+18.2) per cent within 2 R-e and 75.6(-16.8)(+15.4) per cent within the radius of our last kinematic tracer at 6.9 R-e. The total dynamical mass within this radius is found to be 1.5(-0.25)(+0.4) x 10(12) M-circle dot. In common with other studies of large ellipticals, we find that our derived dynamical mass profile is consistently higher than that derived by X-ray observations, by a factor of around 2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BALDON, R. D. M., D. F. M. LOBATO, L. P. CARVALHO, P. Y. L. WUN, P. R. P. SANTIAGO, and F. V. SERRAO. Effect of Functional Stabilization Training on Lower Limb Biomechanics in Women. Med. Sci. Sports Exerc., Vol. 44, No. 1, pp. 135-145, 2012. Purpose: This study aimed to verify the effects of functional stabilization training on lower limb kinematics, functional performance, and eccentric hip and knee torques. Methods: Twenty-eight women were divided into a training group (TG; n = 14), which carried out the functional stabilization training during 8 wk, and a control group (CG; n = 14), which carried out no physical training. The kinematic assessment of the lower limb was performed during a single-leg squat, and the functional performance was evaluated by way of the single-leg triple hop and the timed 6-m single-leg hop tests. The eccentric hip abductor, adductor, lateral rotator, medial rotator, and the knee flexor and extensor torques were measured using an isokinetic dynamometer. Results: After 8 wk, the TG significantly reduced the values for knee abduction (from -6.86 degrees to 1.49 degrees), pelvis depression (from -10.21 degrees to -7.86 degrees) and femur adduction (from 7.08 degrees to 5.19 degrees) as well as increasing the excursion of femur lateral rotation (from -0.55 degrees to -3.67 degrees). Similarly, the TG significantly increased the values of single-leg triple hop (from 3.52 to 3.92 m) and significantly decreased the values of timed 6-m single-leg hop tests (from 2.43 to 2.14 s). Finally, the TG significantly increased the eccentric hip abductor (from 1.31 to 1.45 N center dot m center dot kg(-1)), hip lateral rotator (from 0.75 to 0.91 N center dot m center dot kg(-1)), hip medial rotator (from 1.45 to 1.66 N center dot m center dot kg(-1)), knee flexor (from 1.43 to 1.55 N center dot m center dot kg(-1)), and knee extensor (from 3.46 to 4.40 N center dot m center dot kg(-1)) torques. Conclusions: Strengthening of the hip abductor and lateral rotator muscles associated with functional training improves dynamic lower limb alignment and increases the strength and functional performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Hsp70 is an essential molecular chaperone in protein metabolism since it acts as a pivot with other molecular chaperone families. Several co-chaperones act as regulators of the Hsp70 action cycle, as for instance Hip (Hsp70-interacting protein). Hip is a tetratricopeptide repeat protein (TPR) that interacts with the ATPase domain in the Hsp70-ADP state, stabilizing it and preventing substrate dissociation. Molecular chaperones from protozoans, which can cause some neglected diseases, are poorly studied in terms of structure and function. Here, we investigated the structural features of Hip from the protozoa Leishmania braziliensis (LbHip), one of the causative agents of the leishmaniasis disease. LbHip was heterologously expressed and purified in the folded state, as attested by circular dichroism and intrinsic fluorescence emission techniques. LbHip forms an elongated dimer, as observed by analytical gel filtration chromatography, analytical ultracentrifugation and small angle X-ray scattering (SAXS). With the SAXS data a low resolution model was reconstructed, which shed light on the structure of this protein, emphasizing its elongated shape and suggesting its domain organization. We also investigated the chemical-induced unfolding behavior of LbHip and two transitions were observed. The first transition was related to the unfolding of the TPR domain of each protomer and the second transition of the dimer dissociation. Altogether. LbHip presents a similar structure to mammalian Hip, despite their low level of conservation, suggesting that this class of eukaryotic protein may use a similar mechanism of action. (C) 2012 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Previous studies indicate that flexible footwear, which mimics the biomechanics of walking barefoot, results in decreased knee loads in patients with knee osteoarthritis (OA) during walking. However, the effect of flexible footwear on other activities of daily living, such as descending stairs, remains unclear. Our objective was to evaluate the influence of inexpensive and minimalist footwear (Moleca) on knee adduction moment (KAM) during stair descent of elderly women with and without knee OA. Methods. Thirty-four elderly women were equally divided into an OA group and a control group (CG). Stair descent was evaluated in barefoot condition, while wearing the Moleca, and while wearing heeled shoes. Kinematics and ground reaction forces were measured to calculate KAM by using inverse dynamics. Results. The OA group experienced a higher KAM during midstance under the barefoot condition (233.3%; P = 0.028), the Moleca (379.2%; P = 0.004), and heeled shoes (217.6%; P = 0.007). The OA group had a similar knee load during early, mid, and late stance with the Moleca compared with the barefoot condition. Heeled shoes increased the knee loads during the early-stance (versus barefoot [16.7%; P < 0.001] and versus the Moleca [15.5%; P < 0.001]), midstance (versus barefoot [8.6%; P = 0.014] and versus the Moleca [9.5%; P = 0.010]), and late-stance phase (versus barefoot [10.6%; P = 0.003] and versus the Moleca [9.2%; P < 0.001]). In the CG, the Moleca produced a knee load similar to the barefoot condition only during the early-stance phase. Conclusion. Besides the general foot protection, the inexpensive and minimalist footwear contributes to decreasing knee loads in elderly women with OA during stair descent. The loads are similar to the barefoot condition and effectively decreased when compared with heeled shoes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

NAKAGAWA, T. H., E. T. U. MORIYA, C. D. MACIEL, and F. V. SERRAO. Frontal Plane Biomechanics in Males and Females with and without Patellofemoral Pain. Med. Sci. Sports &ere., Vol. 44, No. 9, pp. 1747-1755, 2012. Purpose: The study's purpose was to compare trunk, pelvis, hip, and knee frontal plane biomechanics in males and females with and without patellofemoral pain syndrome (PFPS) during stepping. Methods: Eighty recreational athletes were equally divided into four groups: female PFPS, female controls, male PFPS, and male controls. Trunk, pelvis, hip, and knee frontal plane kinematics and activation of the gluteus medius were evaluated at 15 degrees, 30 degrees, 45 degrees, and 60 degrees of knee flexion during the downward and upward phases of the stepping task. Isometric hip abductor torque was also evaluated. Results: Females showed increased hip adduction and knee abduction at all knee flexion angles, greater ipsilateral trunk lean and contralateral pelvic drop from 60 degrees of knee flexion till the end of the stepping task (P = 0.027-0.001), diminished hip abductor torque (P < 0.001), and increased gluteus medius activation than males (P = 0.008-0.001). PFPS subjects presented increased knee abduction at all the angles evaluated; greater trunk, pelvis, and hip motion from 45 of knee flexion of the downward phase till the end of the maneuver; and diminished gluteus medius activation at 60 degrees of knee flexion, compared with controls (P = 0.034-0.001). Females with PFPS showed lower hip abductor torque compared with the other groups. Conclusions: Females presented with altered frontal plane biomechanics that may predispose them to knee injury. PFPS subjects showed frontal plane biomechanics that could increase the lateral patellofemoral joint stress at all the angles evaluated and could increase even more from 45 degrees of knee flexion in the downward phase untill the end of the maneuver. Hip abductor strengthening and motor control training should be considered when treating females with PFPS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Study design Controlled laboratory study. Objectives The purposes of this paper were to investigate (d) whether vastus medialis obliquus (VMO), vastus lateralis longus (VLL) and vastus lateralis obliquus (VLO) EMG activity can be influenced by hip abduction performed by healthy subjects. Background Some clinicians contraindicate hip abduction for patellofemoral patients (with) based on the premise that hip abduction could facilitate the VLL muscle activation leading to a VLL and VMO imbalance Methods and measures Twenty-one clinically healthy subjects were involved in the study, 10 women and 11 men (aged X = 23.3 ± 2.9). The EMG signals were collected using a computerized EMG VIKING II, with 8 channels and three pairs of surface electrodes. EMG activity was obtained from MVIC knee extension at 90° of flexion in a seated position and MVIC hip abduction at 0° and 30° with patients in side-lying position with the knee in full extension. The data were normalized in the MVIC knee extension at 50° of flexion in a seated position, and were submitted to ANOVA test with subsequent application of the Bonferroni multiple comparisons analysis test. The level of significance was defined as p ≤ 0.05. Results The VLO muscle demonstrated a similar pattern to the VMO muscle showing higher EMG activity in MVIC knee extension at 90° of flexion compared with MVIC hip abduction at 0° and 30° of abduction for male (p < 0.0007) and MVIC hip abduction at 0° of abduction for female subjects (p < 0.02196). There were no statistically significant differences in the VLL EMG activity among the three sets of exercises tested. Conclusion The results showed that no selective EMG activation was observed when comparison was made between the VMO, VLL and VLO muscles while performing MVIC hip abduction at 0° and 30° of abduction and MVIC knee extension at 90° of flexion in both male and female subjects. Our findings demonstrate that hip abduction do not facilitated VLL and VLO activity in relation to the VMO, however, this study included only healthy subjects performing maximum voluntary isometric contraction contractions, therefore much remains to be discovered by future research

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The literature indicated that the majority of professional ballet dancers present static and active dynamic range of motion difference between left and right lower limbs, however, no previous study focused this difference in non-professional ballet dancers. In this study we aimed to evaluate active movements of the hip in non-professional classical dancers. Methods We evaluated 10 non professional ballet dancers (16-23 years old). We measured the active range of motion and flexibility through Well Banks. We compared active range of motion between left and right sides (hip flexion and abduction) and performed correlation between active movements and flexibility. Results There was a small difference between the right and left sides of the hip in relation to the movements of flexion and abduction, which suggest the dominant side of the subjects, however, there was no statistical significance. Bank of Wells test revealed statistical difference only between the 1st and the 3rd measurement. There was no correlation between the movements of the hip (abduction and flexion, right and left sides) with the three test measurements of the bank of Wells. Conclusion There is no imbalance between the sides of the hip with respect to active abduction and flexion movements in non-professional ballet dancers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare the existence of radiographic abnormalities in two groups of patients, those with and without hip pain. METHODS: A total 222 patients were evaluated between March 2007 and April 2009; 122 complained of groin pain, and 100 had no symptoms. The individuals in both groups underwent radiographic examinations of the hip using the following views: anteroposterior, Lequesne false profile, Dunn, Dunn 45º, and Ducroquet. RESULTS: A total of 1110 radiographs were evaluated. Female patients were prevalent in both groups (52% symptomatic, 58% asymptomatic). There were statistically significant differences between the groups in age (p<0.0001), weight (p = 0.002) and BMI (p = 0.006). The positive findings in the group with groin pain consisted of the presence of a bump on the femoral head in the anteroposterior view (p<0.0001) or in the Dunn 45º view (p = 0.008). The difference in the a angle in the anteroposterior, Dunn, Dunn 45º, and Ducroquet views for all of the cases studied was p,0.0001. The joint space measurement differed significantly between groups in the Lequesne view (p = 0.007). The Lequesne anteversion angle (ρ) and the femoral offset measurement also differed significantly (p = 0.005 and p = 0.0001, respectively). CONCLUSIONS: We conclude that the best views for diagnosing a femoroacetabular impingement are the anteroposterior pelvic orthostatic, the Dunn 45º, and the Ducroquet views. The following findings correlated with hip pain: a decrease in the femoral offset, an increase in the α angle, an increase in the Lequesne ρ angle, a decrease in the CE angle of Wiberg, a thinner articular space and the presence of a bump on the femoral head-neck transition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research aimed for an extended knowledge and understanding of young people in stigmatized areas and their construction of group identity. With a focus on Roma youths in Konik, Montenegro, and their involvement in hip-hop we wanted to explore what this culture meant to them in relation to their context. An ethnographic approach was used in collecting the empirical data through observations, interpreting music lyrics and conducting qualitative semi-structured interviews. Five young Roma boys from Konik, all involved in hip-hop, were interviewed. Theoretical perspectives on identity, youth culture and stigmatization were central. In addition, Bourdieu’s theory regarding cultural capital was emphasized and connected to youths and hip-hop. The empirical material showed that involvement in hip-hop provided the Roma youths with a group identity that they referred to in positive terms. Contextual factors of stigmatization excluded the Roma group from the majority population and the engagement in hip-hop created a possibility for the youths to be someone. The cultural capital gained through hip-hop was not used to verify and legitimate an authentic Roma identity. It was rather a way for them to create boundaries towards the negative elements in their community.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The barred spiral galaxy M83 (NGC5236) has been observed in the 12CO J=1–0 and J=2–1 millimetre lines with the Swedish-ESO Submillimetre Telescope (SEST). The sizes of the CO maps are 100×100, and they cover the entire optical disk. The CO emission is strongly peaked toward the nucleus. The molecular spiral arms are clearly resolved and can be traced for about 360º. The total molecular gas mass is comparable to the total Hi mass, but H2 dominates in the optical disk. Iso-velocity maps show the signature of an inclined, rotating disk, but also the effects of streaming motions along the spiral arms. The dynamical mass is determined and compared to the gas mass. The pattern speed is determined from the residual velocity pattern, and the locations of various resonances are discussed. The molecular gas velocity dispersion is determined, and a trend of decreasing dispersion with increasing galactocentric radius is found. A total gas (H2+Hi+He) mass surface density map is presented, and compared to the critical density for star formation of an isothermal gaseous disk. The star formation rate (SFR) in the disk is estimated using data from various star formation tracers. The different SFR estimates agree well when corrections for extinctions, based on the total gas mass map, are made. The radial SFR distribution shows features that can be associated with kinematic resonances. We also find an increased star formation efficiency in the spiral arms. Different Schmidt laws are fitted to the data. The star formation properties of the nuclear region, based on high angular resolution HST data, are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to evaluate the extent of stability achieved during surgery. Some of these are in-vitro protocols while other tools are coinceived for the post-operative assessment of prosthesis migration relative to the host bone. In vitro protocols reported in the literature are not exportable to the operating room. Anyway most of them show a good overall accuracy. The RSA, EBRA and the radiographic analysis are currently used to check the healing process of the implanted femur at different follow-ups, evaluating implant migration, occurance of bone resorption or osteolysis at the interface. These methods are important for follow up and clinical study but do not assist the surgeon during implantation. At the time I started my Ph.D Study in Bioengineering, only one study had been undertaken to measure stability intra-operatively. No follow-up was presented to describe further results obtained with that device. In this scenario, it was believed that an instrument that could measure intra-operatively the stability achieved by an implanted stem would consistently improve the rate of success. This instrument should be accurate and should give to the surgeon during implantation a quick answer concerning the stability of the implanted stem. With this aim, an intra-operative device was designed, developed and validated. The device is meant to help the surgeon to decide how much to press-fit the implant. It is essentially made of a torsional load cell, able to measure the extent of torque applied by the surgeon to test primary stability, an angular sensor that measure the relative angular displacement between stem and femur, a rigid connector that enable connecting the device to the stem, and all the electronics for signals conditioning. The device was successfully validated in-vitro, showing a good overall accuracy in discriminating stable from unstable implants. Repeatability tests showed that the device was reliable. A calibration procedure was then performed in order to convert the angular readout into a linear displacement measurement, which is an information clinically relevant and simple to read in real-time by the surgeon. The second study reported in my thesis, concerns the evaluation of the possibility to have predictive information regarding the primary stability of a cementless stem, by measuring the micromotion of the last rasp used by the surgeon to prepare the femoral canal. This information would be really useful to the surgeon, who could check prior to the implantation process if the planned stem size can achieve a sufficient degree of primary stability, under optimal press fitting conditions. An intra-operative tool was developed to this aim. It was derived from a previously validated device, which was adapted for the specific purpose. The device is able to measure the relative micromotion between the femur and the rasp, when a torsional load is applied. An in-vitro protocol was developed and validated on both composite and cadaveric specimens. High correlation was observed between one of the parameters extracted form the acquisitions made on the rasp and the stability of the corresponding stem, when optimally press-fitted by the surgeon. After tuning in-vitro the protocol as in a closed loop, verification was made on two hip patients, confirming the results obtained in-vitro and highlighting the independence of the rasp indicator from the bone quality, anatomy and preserving conditions of the tested specimens, and from the sharpening of the rasp blades. The third study is related to an approach that have been recently explored in the orthopaedic community, but that was already in use in other scientific fields. It is based on the vibration analysis technique. This method has been successfully used to investigate the mechanical properties of the bone and its application to evaluate the extent of fixation of dental implants has been explored, even if its validity in this field is still under discussion. Several studies have been published recently on the stability assessment of hip implants by vibration analysis. The aim of the reported study was to develop and validate a prototype device based on the vibration analysis technique to measure intra-operatively the extent of implant stability. The expected advantages of a vibration-based device are easier clinical use, smaller dimensions and minor overall cost with respect to other devices based on direct micromotion measurement. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The fourth study concerns the application of the device based on the vibration analysis technique to several cases, considering both composite and cadaveric specimens. Different degrees of bone quality were tested, as well as different femur anatomies and several levels of press-fitting were considered. The aim of the study was to verify if it is possible to discriminate between stable and quasi-stable implants, because this is the most challenging detection for the surgeon in the operation room. Moreover, it was possible to validate the measurement protocol by comparing the results of the acquisitions made with the vibration-based tool to two reference measurements made by means of a validated technique, and a validated device. The results highlighted that the most sensitive parameter to stability is the shift in resonance frequency of the stem-bone system, showing high correlation with residual micromotion on all the tested specimens. Thus, it seems possible to discriminate between many levels of stability, from the grossly loosened implant, through the quasi-stable implants, to the definitely stable one. Finally, an additional study was performed on a different type of hip prosthesis, which has recently gained great interest thus becoming fairly popular in some countries in the last few years: the hip resurfacing prosthesis. The study was motivated by the following rationale: although bone-prosthesis micromotion is known to influence the stability of total hip replacement, its effect on the outcome of resurfacing implants has not been investigated in-vitro yet, but only clinically. Thus the work was aimed at verifying if it was possible to apply to the resurfacing prosthesis one of the intraoperative devices just validated for the measurement of the micromotion in the resurfacing implants. To do that, a preliminary study was performed in order to evaluate the extent of migration and the typical elastic movement for an epiphyseal prosthesis. An in-vitro procedure was developed to measure micromotions of resurfacing implants. This included a set of in-vitro loading scenarios that covers the range of directions covered by hip resultant forces in the most typical motor-tasks. The applicability of the protocol was assessed on two different commercial designs and on different head sizes. The repeatability and reproducibility were excellent (comparable to the best previously published protocols for standard cemented hip stems). Results showed that the procedure is accurate enough to detect micromotions of the order of few microns. The protocol proposed was thus completely validated. The results of the study demonstrated that the application of an intra-operative device to the resurfacing implants is not necessary, as the typical micromovement associated to this type of prosthesis could be considered negligible and thus not critical for the stabilization process. Concluding, four intra-operative tools have been developed and fully validated during these three years of research activity. The use in the clinical setting was tested for one of the devices, which could be used right now by the surgeon to evaluate the degree of stability achieved through the press-fitting procedure. The tool adapted to be used on the rasp was a good predictor of the stability of the stem. Thus it could be useful for the surgeon while checking if the pre-operative planning was correct. The device based on the vibration technique showed great accuracy, small dimensions, and thus has a great potential to become an instrument appreciated by the surgeon. It still need a clinical evaluation, and must be industrialized as well. The in-vitro tool worked very well, and can be applied for assessing resurfacing implants pre-clinically.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. The surgical treatment of dysfunctional hips is a severe condition for the patient and a costly therapy for the public health. Hip resurfacing techniques seem to hold the promise of various advantages over traditional THR, with particular attention to young and active patients. Although the lesson provided in the past by many branches of engineering is that success in designing competitive products can be achieved only by predicting the possible scenario of failure, to date the understanding of the implant quality is poorly pre-clinically addressed. Thus revision is the only delayed and reliable end point for assessment. The aim of the present work was to model the musculoskeletal system so as to develop a protocol for predicting failure of hip resurfacing prosthesis. Methods. Preliminary studies validated the technique for the generation of subject specific finite element (FE) models of long bones from Computed Thomography data. The proposed protocol consisted in the numerical analysis of the prosthesis biomechanics by deterministic and statistic studies so as to assess the risk of biomechanical failure on the different operative conditions the implant might face in a population of interest during various activities of daily living. Physiological conditions were defined including the variability of the anatomy, bone densitometry, surgery uncertainties and published boundary conditions at the hip. The protocol was tested by analysing a successful design on the market and a new prototype of a resurfacing prosthesis. Results. The intrinsic accuracy of models on bone stress predictions (RMSE < 10%) was aligned to the current state of the art in this field. The accuracy of prediction on the bone-prosthesis contact mechanics was also excellent (< 0.001 mm). The sensitivity of models prediction to uncertainties on modelling parameter was found below 8.4%. The analysis of the successful design resulted in a very good agreement with published retrospective studies. The geometry optimisation of the new prototype lead to a final design with a low risk of failure. The statistical analysis confirmed the minimal risk of the optimised design over the entire population of interest. The performances of the optimised design showed a significant improvement with respect to the first prototype (+35%). Limitations. On the authors opinion the major limitation of this study is on boundary conditions. The muscular forces and the hip joint reaction were derived from the few data available in the literature, which can be considered significant but hardly representative of the entire variability of boundary conditions the implant might face over the patients population. This moved the focus of the research on modelling the musculoskeletal system; the ongoing activity is to develop subject-specific musculoskeletal models of the lower limb from medical images. Conclusions. The developed protocol was able to accurately predict known clinical outcomes when applied to a well-established device and, to support the design optimisation phase providing important information on critical characteristics of the patients when applied to a new prosthesis. The presented approach does have a relevant generality that would allow the extension of the protocol to a large set of orthopaedic scenarios with minor changes. Hence, a failure mode analysis criterion can be considered a suitable tool in developing new orthopaedic devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Curved mountain belts have always fascinated geologists and geophysicists because of their peculiar structural setting and geodynamic mechanisms of formation. The need of studying orogenic bends arises from the numerous questions to which geologists and geophysicists have tried to answer to during the last two decades, such as: what are the mechanisms governing orogenic bends formation? Why do they form? Do they develop in particular geological conditions? And if so, what are the most favorable conditions? What are their relationships with the deformational history of the belt? Why is the shape of arcuate orogens in many parts of the Earth so different? What are the factors controlling the shape of orogenic bends? Paleomagnetism demonstrated to be one of the most effective techniques in order to document the deformation of a curved belt through the determination of vertical axis rotations. In fact, the pattern of rotations within a curved belt can reveal the occurrence of a bending, and its timing. Nevertheless, paleomagnetic data alone are not sufficient to constrain the tectonic evolution of a curved belt. Usually, structural analysis integrates paleomagnetic data, in defining the kinematics of a belt through kinematic indicators on brittle fault planes (i.e., slickensides, mineral fibers growth, SC-structures). My research program has been focused on the study of curved mountain belts through paleomagnetism, in order to define their kinematics, timing, and mechanisms of formation. Structural analysis, performed only in some regions, supported and integrated paleomagnetic data. In particular, three arcuate orogenic systems have been investigated: the Western Alpine Arc (NW Italy), the Bolivian Orocline (Central Andes, NW Argentina), and the Patagonian Orocline (Tierra del Fuego, southern Argentina). The bending of the Western Alpine Arc has been investigated so far using different approaches, though few based on reliable paleomagnetic data. Results from our paleomagnetic study carried out in the Tertiary Piedmont Basin, located on top of Alpine nappes, indicate that the Western Alpine Arc is a primary bend that has been subsequently tightened by further ~50° during Aquitanian-Serravallian times (23-12 Ma). This mid-Miocene oroclinal bending, superimposing onto a pre-existing Eocene nonrotational arc, is the result of a composite geodynamic mechanism, where slab rollback, mantle flows, and rotating thrust emplacement are intimately linked. Relying on our paleomagnetic and structural evidence, the Bolivian Orocline can be considered as a progressive bend, whose formation has been driven by the along-strike gradient of crustal shortening. The documented clockwise rotations up to 45° are compatible with a secondary-bending type mechanism occurring after Eocene-Oligocene times (30-40 Ma), and their nature is probably related to the widespread shearing taking place between zones of differential shortening. Since ~15 Ma ago, the activity of N-S left-lateral strike-slip faults in the Eastern Cordillera at the border with the Altiplano-Puna plateau induced up to ~40° counterclockwise rotations along the fault zone, locally annulling the regional clockwise rotation. We proposed that mid-Miocene strike-slip activity developed in response of a compressive stress (related to body forces) at the plateau margins, caused by the progressive lateral (southward) growth of the Altiplano-Puna plateau, laterally spreading from the overthickened crustal region of the salient apex. The growth of plateaux by lateral spreading seems to be a mechanism common to other major plateaux in the Earth (i.e., Tibetan plateau). Results from the Patagonian Orocline represent the first reliable constraint to the timing of bending in the southern tip of South America. They indicate that the Patagonian Orocline did not undergo any significant rotation since early Eocene times (~50 Ma), implying that it may be considered either a primary bend, or an orocline formed during the late Cretaceous-early Eocene deformation phase. This result has important implications on the opening of the Drake Passage at ~32 Ma, since it is definitely not related to the formation of the Patagonian orocline, but the sole consequence of the Scotia plate spreading. Finally, relying on the results and implications from the study of the Western Alpine Arc, the Bolivian Orocline, and the Patagonian Orocline, general conclusions on curved mountain belt formation have been inferred.