918 resultados para High-speed digital imaging


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To evaluate the influence of JPEG quality factors 100, 80 and 60 on the reproducibility of identification of cephalometric points on images of lateral cephalograms, compared with the Digital Imaging and Communications in Medicine (DICOM) format. Methods: The sample was composed of 30 images of digital lateral cephalograms obtained from 30 individuals (15 males and 15 females) on a phosphor plate system in DICOM format. The images were converted to JPEG with quality factors 100, 80 and 60 with the aid of software, adding up to 90 images. The 120 images (DICOM, JPEG 100, 80 and 60) were blinded and 12 cephalometric points were identified on each image by three calibrated orthodontists, using the x-y coordinate system, on a cephalometric software. Results: The results revealed that identification of cephalometric points was highly reproducible, except for the point Orbitale (Or) on the x-axis. The different file formats did not present a statistically significant difference. Conclusions: JPEG images of lateral cephalograms with quality factors 100, 80 and 60 did not present alterations in the reproducibility of identification of cephalometric points compared with the DICOM format. Good reproducibility was achieved for the 12 points, except for point Or on the x-axis. Dentomaxillofacial Radiology (2009) 38, 393-400. doi: 10.1259/dmfr/40996636

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lentiviral vectors pseudotyped with vesicular stomatitis virus glycoprotein (VSV-G) are emerging as the vectors of choice for in vitro and in vivo gene therapy studies. However, the current method for harvesting lentivectors relies upon ultracentrifugation at 50 000 g for 2 h. At this ultra-high speed, rotors currently in use generally have small volume capacity. Therefore, preparations of large volumes of high-titre vectors are time-consuming and laborious to perform. In the present study, viral vector supernatant harvests from vector-producing cells (VPCs) were pre-treated with various amounts of poly-L-lysine (PLL) and concentrated by low speed centrifugation. Optimal conditions were established when 0.005% of PLL (w/v) was added to vector supernatant harvests, followed by incubation for 30 min and centrifugation at 10 000 g for 2 h at 4 degreesC. Direct comparison with ultracentrifugation demonstrated that the new method consistently produced larger volumes (6 ml) of high-titre viral vector at 1 x 10(8) transduction unit (TU)/ml (from about 3000 ml of supernatant) in one round of concentration. Electron microscopic analysis showed that PLL/viral vector formed complexes, which probably facilitated easy precipitation at low-speed concentration (10 000 g), a speed which does not usually precipitate viral particles efficiently. Transfection of several cell lines in vitro and transduction in vivo in the liver with the lentivector/PLL complexes demonstrated efficient gene transfer without any significant signs of toxicity. These results suggest that the new method provides a convenient means for harvesting large volumes of high-titre lentivectors, facilitate gene therapy experiments in large animal or human gene therapy trials, in which large amounts of lentiviral vectors are a prerequisite.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O presente trabalho consiste na implementação em hardware de unidades funcionais dedicadas e optimizadas, para a realização das operações de codificação e descodificação, definidas na norma de codificação com perda Joint Photographic Experts Group (JPEG), ITU-T T.81 ISO/IEC 10918-1. Realiza-se um estudo sobre esta norma de forma a caracterizar os seus principais blocos funcionais. A finalidade deste estudo foca-se na pesquisa e na proposta de optimizações, de forma a minimizar o hardware necessário para a realização de cada bloco, de modo a que o sistema realizado obtenha taxas de compressão elevadas, minimizando a distorção obtida. A redução de hardware de cada sistema, codificador e descodificador, é conseguida à custa da manipulação das equações dos blocos Forward Discrete Cosine Transform (FDCT) e Quantificação (Q) e dos blocos Forward Discrete Cosine Transform (IDCT) e Quantificação Inversa (IQ). Com as conclusões retiradas do estudo e através da análise de estruturas conhecidas, descreveu-se cada bloco em Very-High-Speed Integrated Circuits (VHSIC) Hardware Description Language (VHDL) e fez-se a sua síntese em Field Programmable Gate Array (FPGA). Cada sistema implementado recorre à execução de cada bloco em paralelo de forma a optimizar a codificação/descodificação. Assim, para o sistema codificador, será realizada a operação da FDCT e Quantificação sobre duas matrizes diferentes e em simultâneo. O mesmo sucede para o sistema descodificador, composto pelos blocos Quantificação Inversa e IDCT. A validação de cada bloco sintetizado é executada com recurso a vectores de teste obtidos através do estudo efectuado. Após a integração de cada bloco, verificou-se que, para imagens greyscale de referência com resolução de 256 linhas por 256 colunas, é necessário 820,5 μs para a codificação de uma imagem e 830,5 μs para a descodificação da mesma. Considerando uma frequência de trabalho de 100 MHz, processam-se aproximadamente 1200 imagens por segundo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Developments in digital detector technologies have been taking place and new digital technologies are available for clinical practice. This chapter is intended to give a technical state-of-the-art overview about computed radiography (CR) and digital radiography (DR) detectors. CR systems use storage-phosphor image plates with a separate image readout process and DR technology converts X-rays into electrical charges by means of a readout process using TFT arrays. Digital detectors offer several advantages when compared to analogue detectors. The knowledge about digital detector technology for use in plain radiograph examinations is thus a fundamental topic to be acquired by radiology professionals and students. In this chapter an overview of digital radiography systems (both CR and DR) currently available for clinical practice is provided.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The characterization of physical properties of digital imaging systems requires the determination and measurement of detectors’ physical performance. Those measures such as modulation transfer function (MTF), noise power spectra (NPS), and detective quantum efficiency (DQE) provide objective evaluations of digital detectors’ performance. To provide an MTF, NPS, and DQE calculation from raw-data images it is necessary to implement a method that is undertaken by two major steps: (1) image acquisition and (2) quantitative measure determination method. In this chapter a comprehensive description about a method to provide the measure of performance of digital radiography detectors is provided.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This chapter addresses technical issues concerning digital technologies. Radiological equipment and technique are briefly introduced together with a discussion about requirements and advantages of digital technologies. Digital technologies offer several advantages when compared to conventional analogical systems, or screen–film (SF) systems. While in clinical practice the practitioners should be aware of technical factors such as image acquisition, management of patient dose, and diagnostic image quality. Thus, digital technologies require an up-to-date scientific knowledge concerning their use in projection radiography. In this chapter, technical considerations concerning digital technologies are provided.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The assessment of patient dose has gained increased attention, still being an issue of concern that arises from the use of digital systems. The development of digital technology offers the possibility for a reduction of radiation dose around 50% without loss in image quality when compared to a conventional screen–film system. Digital systems give an equivalent or superior diagnostic performance and also several other advantages, but the risk of overexposure with no adverse effect on image quality could be present. This chapter refers to the management of patient dose and provides an explanation of dose-related concepts. In this chapter, exposure influence in dose and image representation and the effects of radiation exposure are also discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Digital radiography detectors—based on different technological solutions—are currently available for clinical applications and widespread in clinical practice. Computed radiography (CR) and digital radiology systems have been available for clinical applications and the trend over the last few years has become digital. Radiology departments have been changing from traditional screen–film technology to digital technology. This chapter is intended to give the reader a practical understanding about the key aspects concerning digital systems, related to the performance of different technologies, image quality, and dose and patient safety/protection. The discussion around an optimization framework for digital systems is provided.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Once in a digital form, a radiographic image may be processed in several ways in order to turn the visualization an act of improved diagnostic value. Practitioners should be aware that, depending on each clinical context, digital image processing techniques are available to help to unveil visual information that is, in fact, carried by the bare digital radiograph and may be otherwise neglected. The range of visual enhancement procedures includes simple techniques that deal with the usual brightness and contrast manipulation up to much more elaborate multi-scale processing that provides customized control over the emphasis given to the relevant finer anatomical details. This chapter is intended to give the reader a practical understanding of image enhancement techniques that might be helpful to improve the visual quality of the digital radiographs and thus to contribute to a more reliable and assertive reporting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Plain radiography still accounts for the vast majority of imaging studies that are performed at multiple clinical instances. Digital detectors are now prominent in many imaging facilities and they are the main driving force towards filmless environments. There has been a working paradigm shift due to the functional separation of acquisition, visualization, and storage with deep impact in the imaging workflows. Moreover with direct digital detectors images are made available almost immediately. Digital radiology is now completely integrated in Picture Archiving and Communication System (PACS) environments governed by the Digital Imaging and Communications in Medicine (DICOM) standard. In this chapter a brief overview of PACS architectures and components is presented together with a necessarily brief account of the DICOM standard. Special focus is given to the DICOM digital radiology objects and how specific attributes may now be used to improve and increase the metadata repository associated with image data. Regular scrutiny of the metadata repository may serve as a valuable tool for improved, cost-effective, and multidimensional quality control procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we present the results of mammography quality control tests related to the work with Portuguese mammography equipment, either in conventional or in digital mammography computed radiography, showing the main differences in the tested equipments. Quality control in mammography is a very special area of quality control in radiology, which demands relatively high knowledge on physics. Digital imaging is changing the standards of the radiographic imaging. Regarding mammography, this is yet a controversial issue owing to some limitations of the digital detectors, like the resolution for instance. A complete set of results regarding radiation protection of the patients submitted to mammography diagnosis is presented. A discussion of the quality image parameters and its interpretation in conventional and digital mammography is presented. In conclusion, we present a sample of results that can be considered as characteristics of mammography equipment in Portugal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trabalho de Projeto para obtenção do grau de Mestre em Engenharia de Eletrónica e Telecomunicações

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dependability is a critical factor in computer systems, requiring high quality validation & verification procedures in the development stage. At the same time, digital devices are getting smaller and access to their internal signals and registers is increasingly complex, requiring innovative debugging methodologies. To address this issue, most recent microprocessors include an on-chip debug (OCD) infrastructure to facilitate common debugging operations. This paper proposes an enhanced OCD infrastructure with the objective of supporting the verification of fault-tolerant mechanisms through fault injection campaigns. This upgraded on-chip debug and fault injection (OCD-FI) infrastructure provides an efficient fault injection mechanism with improved capabilities and dynamic behavior. Preliminary results show that this solution provides flexibility in terms of fault triggering and allows high speed real-time fault injection in memory elements

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tendo em conta a popularidade que as comunicações Wi-Fi têm na atualidade em vários dispositivos como computadores portáteis, telemóveis ou tablets, sendo estes utilizados praticamente por qualquer pessoa, surgiu a ideia de utilizar esta tecnologia de baixo custo e isenta de licenciamento num cenário de comunicações marítimas. Neste contexto, esta permite fornecer o acesso à Internet em banda larga a grupos de embarcações, que atualmente recorrem a tecnologias de elevado custo (satélite) e/ou de banda estreita (rádios VHF). Com o acesso em banda larga, os proprietários poderão utilizar aplicações informáticas de interesse à atividade de negócio ou de lazer, até então só disponíveis junto à costa onde existe cobertura celular. Nesta tese pretende-se fazer um estudo teórico e prático sobre o alcance e respetivo desempenho de comunicações de banda larga em ambiente marítimo, utilizando parte da gama de frequências dos 5,8 GHz, isenta de licença, e a norma IEEE 802.11n. Para se utilizar equipamento produzido em massa a operar nessa gama, existem duas normas disponíveis, a IEEE 802.11a e a IEEE 802.11n. Optou-se pelo IEEE 802.11n pois os esquemas de codificação ao nível físico permitem débitos mais elevados e MIMO. Para a realização dos testes experimentais, foi necessário elaborar um protótipo de comunicação ponto a ponto, constituído por dois nós de comunicação. Um deles foi instalado numa embarcação de pesca em colaboração com a Associação Propeixe e o outro no Edifício Transparente, no Porto, em colaboração com a entidade gestora do edifício e a Associação Porto Digital. Tanto quanto se conhece é o primeiro teste de comunicações Wi-Fi realizado nestas condições a nível mundial. Os objetivos do trabalho foram atingidos. Foi possível estabelecer comunicações Wi-Fi na banda dos 5,8 GHz até cerca de 7 km com débito médio mínimo de 1 Mbit/s. O ambiente de testes desenvolvido e os resultados obtidos servirão de base para futuros trabalhos de investigação na área das comunicações marítimas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics