867 resultados para HIGH-PERFORMANCE LIQUID
Resumo:
We present a system for keyword search on Cantonese conversational telephony audio, collected for the IARPA Babel program, that achieves good performance by combining postings lists produced by diverse speech recognition systems from three different research groups. We describe the keyword search task, the data on which the work was done, four different speech recognition systems, and our approach to system combination for keyword search. We show that the combination of four systems outperforms the best single system by 7%, achieving an actual term-weighted value of 0.517. © 2013 IEEE.
Resumo:
This paper describes first some of the recent performance checks on the high performance fibre-reinforced cementitious composite CARDIFRC and then its application to the retrofitting of damaged concrete beams. It is shown that an even distribution of fibres throughout the bulk of the material is crucial to its excellent fatigue performance and to the reduction in the autogenous shrinkage strains. The distribution of fibres in beams, cylinders and strips is examined using computerised tomography imaging and traditional image analysis. Thin strips of CARDIFRC are used to retrofit damaged concrete beams which are subjected to thermal cycling. It is shown that neither the load carrying capacity of the retrofitted beams nor the bond between retrofit strips and concrete deteriorates with thermal cycling. The load carrying capacity of retrofitted beams is predicted with a model based on fracture mechanics, and the predictions are shown to be in good agreement with test data. © 2006 Elsevier Ltd. All rights reserved.
Resumo:
A gate-modulated nanowire oxide photosensor is fabricated by electron-beam lithography and conventional dry etch processing.. The device characteristics are good, including endurance of up to 10(6) test cycles, and gate-pulse excitation is used to remove persistent photoconductivity. The viability of nanowire oxide phototransistors for high speed and high resolution applications is demonstrated, thus potentially expanding the scope of exploitation of touch-free interactive displays.
Resumo:
Microcystins (MCs) comprise a family of more than 80 related cyclic hepatotoxic heptapeptides. Oxidation of MCs causes cleavage of the chemically unique C-20 beta-amino acid (2S, 3S, 8S, 9S)-3-amino-9-methoxy-2,6,8-trimethyl-10-phenyldeca-4,6-dienoic acid (Adda) amino to form 2-methyl-3-methoxy-4-phenylbutanoic acid (MMPB), which has been exploited to enable analysis of the entire family. In the present study, the reaction conditions (e.g. concentration of the reactants. temperature and pH) used in the production of MMPB by oxidation of cyanobacterial samples with permanganate-periodate were optimized through a series of well-controlled batch experiments. The oxidation product (MMPB) was then directly analyzed by high-performance liquid chromatography with diode array detection. The results of this study provided insight into the influence of reaction conditions on the yield of MMPB. Specifically, the optimal conditions, including a high dose of permanganate (>= 50 mM) in saturated periodate solution at ambient temperature under alkaline conditions (pH similar to 9) over 1-4 h were proposed, as indicated by a MMPB yield of greater than 85%. The technique developed here was applied to determine the total concentration of MCs in cyanobacterial bloom samples, and indicated that the MMPB technique was a highly sensitive and accurate method of quantifying total MCs. Additionally, these results will aid in development of a highly effective analytical method for detection of MMPB as an oxidation product for evaluation of total MCs in a wide range of environmental sample matrices, including natural waters, soils (sediments) and animal tissues. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
The development is described of a computer-controlled bowing machine that can bow a string with a range of gestures that match or exceed the capabilities of a human violinist. Example measurements of string vibration under controlled bowing conditions are shown, including a Schelleng diagram and a set of Guettler diagrams, for the open D string of a cello. For some results a rosin-coated rod was used in place of a conventional bow, to provide quantitative data for comparison with theoretical predictions. The results show qualitative consistency with the predictions of Schelleng and Guettler, but details are revealed that go beyond the limitations of existing models. © S. Hirzel Verlag · EAA.
Resumo:
A high performance ferroelectric non-volatile memory device based on a top-gate ZnO nanowire (NW) transistor fabricated on a glass substrate is demonstrated. The ZnO NW channel was spin-coated with a poly (vinylidenefluoride-co-trifluoroethylene) (P(VDF-TrFE)) layer acting as a top-gate dielectric without buffer layer. Electrical conductance modulation and memory hysteresis are achieved by a gate electric field induced reversible electrical polarization switching of the P(VDF-TrFE) thin film. Furthermore, the fabricated device exhibits a memory window of ∼16.5 V, a high drain current on/off ratio of ∼105, a gate leakage current below ∼300 pA, and excellent retention characteristics for over 104 s. © 2014 AIP Publishing LLC.
Resumo:
A sensitive and selective liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous quantitative determination of microcystin-LR (MC-LR) and its glutathione conjugate (MC-LR-GSH) in fish tissues. The analytes were extracted from fish liver and kidney using 0.01 M EDTA-Na-2-5% acetic acid, followed by a solid-phase extraction (SPE) on Oasis HLB and silica cartridges. High-performance liquid chromatography (HPLC) with electrospray ionization mass spectrometry, operating in selected reaction monitoring (SRM) mode, was used to quantify MC-LR and its glutathione conjugate in fish liver and kidney. Recoveries of analytes were assessed at three concentrations (0.2, 1.0, and 5 mu g g(-1) dry weight [DW]) and ranged from 91 to 103% for MC-LR, and from 65.0 to 75.7% for MC-LR-GSH. The assay was linear within the range from 0.02 to 5.0 mu g g(-1) DW, with a limit of quantification (LOQ) of 0.02 mu g g(-1) DW. The limit of detection (LOD) of the method was 0.007 mu g g(-1) DW in both fish liver and kidney. The overall precision was determined on three different days. The values for within- and between-day precision in liver and kidney were within 15%. This method was applied to the identification and quantification of MC-LR and its glutathione conjugate in liver and kidney of fish with acute exposure of MC-LR. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
© 2014 AIP Publishing LLC. We report bilayer-graphene field effect transistors operating as Terahertz (THz) broadband photodetectors based on plasma-waves excitation. By employing wide-gate geometries or buried gate configurations, we achieve a responsivity ∼1.2 V/W (1.3 mA/W) and a noise equivalent power ∼2 × 10-9 W/√Hz in the 0.29-0.38 THz range, in photovoltage and photocurrent mode. The potential of this technology for scalability to higher frequencies and the development of flexible devices makes our approach competitive for a future generation of THz detection systems.
Resumo:
Uncooled directly-modulated 1.3μm VCSELs are shown to exhibit dynamic range, linearity and noise performance required for wireless LAN applications. A multimode fiber based WLAN 802.11b system shows performances comparable to systems with state-of-the-art DFB lasers. © 2005 Optical Society of America.
Resumo:
Uncooled directly-modulated 1.3μm VCSELs are shown to exhibit dynamic range, linearity and noise performance required for wireless LAN applications. A multimode fiber based WLAN 802.11b system shows performances comparable to systems with state-of-the-art DFB lasers. © 2005 Optical Society of America.
Resumo:
We experimentally show that a hybrid-integrated Mach-Zehnder switch with a high performance gate profile allows retiming of optical signals with an accuracy of 500-700fs even if the input timing jitter is increased to 3ps. © 2004 Optical Society of America.