957 resultados para GENESIS (Computer system)


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The effective activity of the pectoralis major and deltoideus anterior muscles in horizontal flyer exercises with external loads of 25, 50, 75 and 100% of the maximum load was studied in 11 male volunteers. The electromyographic analysis was done by using MEDI-TRACE-200 surface electrodes connected to a biological signal acquisition mode coupled to a PC/AT computer. The electromyographic signals were processed and the values obtained were normalized through maximum voluntary isometric contraction. It was statistically observed that in all types and loads of this exercise, the muscles presented significant differences in the concentric and eccentric phases. In the concentric phase, when different loads were compared, the muscles were more active with 75 and 100% of the maximum load, while in the eccentric phase, higher activity was observed with 100% of the maximum load. By analyzing each load effect in the concentric phase, it was verified that the muscles on the left side were more active than those on the right side with 25, 75 and 100% of the maximum load.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Improper use of pesticides can lead to significant environmental impacts such as, contamination of environmental compartments, being the aquatic compartments the most vulnerable. In this context, the spatialization of pesticides concentrations estimative in groundwater provides important insights for decision making in managing and monitoring pesticides use. This study aimed to spatialize estimatives of groundwater contamination by Tebuthiuron, from different irrigation depths in the Rio Pardo basin, Pardinho-SP, Brazil. The simulations were performed using the ARAquá computer system, considering 0mm, 200 mm and 400 mm annual irrigation depths. Geostatistical techniques were used to obtain the spatial distribution of the simulated estimative. Tebuthiuron maps estimating concentration in groundwater were obtained by Kriging interpolation method, and indicated the areas with high potential for groundwater contamination. Considering all the simulations, it was concluded that there was no risk of groundwater contamination by Tebuthiuron in the study area.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Color vision consists of the discrimination of objects based on their spectral composition. Among primates, the majority of Platyrrhini monkeys are estimated to have polymorphic and sex-linked dichromacy. The objective of this study was to compare the results produced by different equipment and software for the assessment of tri- and dichromatic conditions in one male and two female Cebus apella. Three experiments were programmed. In Experiment 1, verifying the trichromatic condition of one female subject and dichromatic condition of the remainder of the subjects was possible using an adapted version of the Cambridge Colour Test. Experiment 2 confirmed the results of Experiment 1 using a different array of stimuli of the same test. Experiment 3, which produced results similar to Experiment 2, consisted of a test developed for a standard computer system using stimuli with color properties similar to the ones used in the previous experiment. Favorable conditions for the assessment of color vision in Platyrrhini can be built with low-cost equipment and software. Once data have been gathered with additional subjects and new stimulus arrangements have been tested and confirmed, the procedure can be used for the evaluation of other Platyrrhini species for which behavioral color discrimination data are currently lacking.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Vibration monitoring requires acceleration transducers capable of providing data with high precision. Accelerometers are the most frequently used vibration transducers. Their calibration plays an important role in measuring vibrations and is a key component in ensuring the integrity of the vibration measurement. For managing secondary calibration data of accelerometers, a database computer system was implemented. The implementation of this software has been an important step forward in providing a wide range of analysis and display tools. This paper reviews the main concepts involving accelerometer secondary calibration and describes the tool developed and the methods used in its development. (C) 2013 Academie des sciences. Published by Elsevier Masson SAS. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This monograph aims to study the problem of thinning, also known by Image Skeletonization, to explore their applications in areas such as, Biometrics, Medicine, Engineering and Cartography. The algorithms of thinning can be classi ed into two major groups: iterative algorithms and non-iterative algorithms. Iterative are sub-divided into sequential algorithms and parallel algorithms. In order to develop a computer system able to extract the skeleton of an image, were studied, analyzed and implemented di erent algorithms for this problem, precisely those of Stentiford, Zhang Suen, and Holt

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The study analyzed contours of the thoracic region of patients undergoing radiotherapy of breast tumors in Hospital Manuel de Abreu of Bauru (institution 1) and the Hospital da Faculdade de Medicina of Botucatu (Institution 2). Were prepared isodose curves corresponding to the contours of the patient, which were presented for radiotherapists doctors both hospital services that enabled the choice of the curve isodose that provides the best distribution of radiation dose in the irradiated volume. Some boundaries were digitized in one institution and sent for preparation of isodose lines in the institution 2, both curves plotted in each of the institutions and for the same contour, were compared, showing that the methodology of Curves of distance is feasible and reliable, while optimizing the routine procedures regarding the handling of isodose plans provided by different radiation equipment. It compares the calculation of the exposure time determined using the isodose curve selected by calculating the value obtained considering the PDP at the point of the middle line of separation between the internal and external fields, the difference between the two methods for determining exposure time was around 2.4%. A study on the angle of the radiation beam at the input field (region breast-air) was conducted showing that, once known a tangent angle of the input beam, one can estimate the angle of the wedge filter used in some procedures for uniformity of dose within the irradiated volume compensation and the lack of tissue in the treatment volume. A comparative study between the isodose curves produced manually with the curves obtained in a two-dimensional computer system, the computer system showed that provides further information regarding the dose gradient within the irradiated volume, in addition to reducing the time spent in preparing the curves isodose

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Agronegócio e Desenvolvimento - Tupã

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To investigate the facial symmetry of high and low dose methotrexate (MTX) treated rats submitted to experimentally displaced mandibular condyle fracture through the recording of cephalometric measurements. METHODS: One hundred male Wistar rats underwent surgery using an experimental model of right condylar fracture. Animals were divided into four groups: A - saline solution (1mL/week); B - dexamethasone (DEX) (0,15mg/Kg); C - MTX low dose (3 mg/Kg/week); D - MTX high dose (30 mg/Kg). Animals were sacrificed at 1, 7, 15, 30 and 90 days postoperatively (n=5). Body weight was recorded. Specimens were submitted to axial radiographic incidence, and cephalometric mensurations were made using a computer system. Linear measurements of skull and mandible, as well as angular measurements of mandibular deviation were taken. Data were subjected to statistical analyses among the groups, periods of sacrifice and between the sides in each group (alpha=0.05). RESULTS: Animals regained body weight over time, except in group D. There was reduction in the mandibular length and also changes in the maxilla as well as progressive deviation in the mandible in relation to the skull basis in group D. CONCLUSION: Treatment with high dose methotrexate had deleterious effect on facial symmetry of rats submitted to experimentally displaced condylar process fracture.