922 resultados para Flow Through Capillary Tubes
Resumo:
This work aims presenting the development of a model and computer simulation of a sucker rod pumping system. This system take into account the well geometry, the flow through the tubing, the dynamic behavior of the rod string and the use of a induction motor model. The rod string were modeled using concentrated parameters, allowing the use of ordinary differential equations systems to simulate it s behavior
Resumo:
O objetivo do presente estudo foi reportar a infecção por Trypanosoma sp. em tuviras (Gymnotus aff. inaequilabiatus) oriundas do Pantanal Sul-mato-grossense, Brasil. Dez peixes provenientes do rio Paraguai, Pantanal Sul-mato-grossense, foram avaliados quanto à presença de hemoflagelados. Tripomastigotas de Trypanosoma sp. foram observados nas extensões sanguíneas de três peixes (30% de prevalência), e algumas formas encontravam-se em divisão. Por meio do exame a fresco e da centrifugação do sangue em capilar de hematócrito como métodos para diagnóstico, a taxa de prevalência foi de 80%. Esse é o primeiro relato de Trypanosoma sp. em tuviras no Brasil.
Resumo:
Experiments were performed to study the effect of surface properties of a vertical channel heated by a source of thermal radiation to induce air flow through convection. Two channels (solar chimney prototype) were built with glass plates, forming a structure of truncated pyramidal geometry. We considered two surface finishes: transparent and opaque. Each stack was mounted on a base of thermal energy absorber with a central opening for passage of air, and subjected to heating by a radiant source comprises a bank of incandescent bulbs and were performed field tests. Thermocouples were fixed on the bases and on the walls of chimneys and then connected to a data acquisition system in computer. The air flow within the chimney, the speed and temperature were measured using a hot wire anemometer. Five experiments were performed for each stack in which convective flows were recorded with values ranging from 17 m³ / h and 22 m³ / h and air flow velocities ranging from 0.38 m / s and 0.56 m / s for the laboratory tests and air velocities between 0.6 m/s and 1.1m/s and convective airflows between 650 m³/h and 1150 m³/h for the field tests. The test data were compared to those obtained by semi-empirical equations, which are valid for air flow induced into channels and simulated data from 1st Thermodynamics equation. It was found that the chimney with transparent walls induced more intense convective flows than the chimney with matte finish. Based on the results obtained can be proposed for the implementation of prototype to exhaust fumes, mists, gases, vapors, mists and dusts in industrial environments, to help promote ventilation and air renewal in built environments and for drying materials, fruits and seeds
Resumo:
The piezoelectric quartz crystal resonators modified with oligonucleotide probes were used for detection of hepatitis C virus (HCV) in serum. The gold electrodes on either rough or smooth surface crystals were modified with a self-assembled monolayer of cystamine. After activation with glutaraldehyde, either avidin or streptavidin were immobilized and used for attachment of biotinylated DNA probes (four different sequences). Piezoelectric biosensors were used in a flow-through setup for direct monitoring of DNA resulting from the reverse transcriptase-linked polymerase chain reaction (RT-PCR) amplification of the original viral RNA. The samples of patients with hepatitis C were analyzed and the results were compared with the standard RT-PCR procedure (Amplicor test kit of Roche, microwell format with spectrophotometric evaluation). The piezoelectric hybridization assay was completed in 10 min and the same sensing surface was suitable for repeated use. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
The Tetraodontiformes order is composed for about 400 species of fish, distributed in ten families, with circuntropical distribution. The morphologic diversity of each family reflects in, part, the different levels of specialization. This group represents an ancestry after-Perciformes and constitutes the last branch of the diffusion of the Teleósteos, occupying a position of prominence. The phylogenetics relationships of the Tetraodontiformes exist diverse works examining and, in all, these families are recognized as groups brothers, being Diodontidae next to Tetraodontidae and Balistidae next to Monacanthidae. Although it possesss a representative number of species, the works involving of the families Balistidae and Monacanthidae are few exemplary, especially species of oceanic islands. In this work cytogenetic studies in five species had been analyzed Cantherhines macrocerus, Cantherhines pullus (Monacanthidae), Melichthys niger (Balistidae), Sphoeroides testudíneus (Tetraodontidae) and Chilomycterus antennatus (Diodontidae); through conventional coloration, Ag-NORs and C banding. Ahead of the different karyological trends of evolution presented by the Tetraodontiformes, the present work also searched to verify the relation existence enters the total size of the chromosomes with the amount of DNA in these groups of Tetraodontiformes. For such, they had been correlated the total size of the chromosomes of these species, with values of content of available DNA in literature. The cytogenetics analyses for the species C.macrocerusJ C.pullus (Monacanthidae) and M.niger (Balistidae), had disclosed 40 chromosomes, all acrocentrics. All possess only one pair of NORs and pericentromeric heterochromatin. For S.testudíneus the found dyploid number was equal 2n=46, with NF=78 (16m+18sm+8st+4a), while that for C.antennatus it possesss 2n=50, with NF=76 (4m+22st+24a). Both species possess simple NORs and pericentromeric heterochromatin blocks. In M.niger, the presence of positive marking (heterochromatin and NOR) in the secondary constriction in the second chromosomic pair suggesting the occurrence of a rearrangement, possibly a fusing involving these homologous ones, indicating that these events had been important for the establishment of the karyological history of this group. A maintenance of the chromosomic constancy found in the populations of C.macrocerus (Monacanthidae) and S.testudineus (Tetraodontidae) perhaps if must for the aiding of the gene flow through oceanic chains. These data contrast with the differentiated kinds of chromosomes of C.antennatus between the Northeast coast and Southeastern, suggesting that the ecological standards of each species, added to the conditions of the marine environment, can be responsible for the karyological delineation of each species. The found characteristics for the species C.macrocerus, C.pullus, M.niger, S.testudineus and C.antennatus add it the available data for other species of Tetraodontiformes. From the data gotten in the present study, it can be inferred that the DNA content possesss direct relation with the total length of the chromosomes
Resumo:
A procedure for calculation of refrigerant mass flow rate is implemented in the distributed numerical model to simulate the flow in finned-tube coil dry-expansion evaporators, usually found in refrigeration and air-conditioning systems. Two-phase refrigerant flow inside the tubes is assumed to be one-dimensional, unsteady, and homogeneous. In themodel the effects of refrigerant pressure drop and the moisture condensation from the air flowing over the external surface of the tubes are considered. The results obtained are the distributions of refrigerant velocity, temperature and void fraction, tube-wall temperature, air temperature, and absolute humidity. The finite volume method is used to discretize the governing equations. Additionally, given the operation conditions and the geometric parameters, the model allows the calculation of the refrigerant mass flow rate. The value of mass flow rate is computed using the process of parameter estimation with the minimization method of Levenberg-Marquardt minimization. In order to validate the developed model, the obtained results using HFC-134a as a refrigerant are compared with available data from the literature.
Uma abordagem para a verificação do comportamento excepcional a partir de regras de designe e testes
Resumo:
Checking the conformity between implementation and design rules in a system is an important activity to try to ensure that no degradation occurs between architectural patterns defined for the system and what is actually implemented in the source code. Especially in the case of systems which require a high level of reliability is important to define specific design rules for exceptional behavior. Such rules describe how exceptions should flow through the system by defining what elements are responsible for catching exceptions thrown by other system elements. However, current approaches to automatically check design rules do not provide suitable mechanisms to define and verify design rules related to the exception handling policy of applications. This paper proposes a practical approach to preserve the exceptional behavior of an application or family of applications, based on the definition and runtime automatic checking of design rules for exception handling of systems developed in Java or AspectJ. To support this approach was developed, in the context of this work, a tool called VITTAE (Verification and Information Tool to Analyze Exceptions) that extends the JUnit framework and allows automating test activities to exceptional design rules. We conducted a case study with the primary objective of evaluating the effectiveness of the proposed approach on a software product line. Besides this, an experiment was conducted that aimed to realize a comparative analysis between the proposed approach and an approach based on a tool called JUnitE, which also proposes to test the exception handling code using JUnit tests. The results showed how the exception handling design rules evolve along different versions of a system and that VITTAE can aid in the detection of defects in exception handling code
Resumo:
This paper describes the preparation of acid carboxymethylcellulose (CMCH), and the results of a study on the adsorption and preconcentration (using batch and flow-through column methods) of Cd(II), Cu(II), Cr(III), Fe(III), Ni(II) and Zn(II) in ethanol medium. The adsorption capacities for each metallic ion were (in mmol g(-1)) Cd(II) = 0.92; Cu(II) = 1.45; Cr(III) = 1.70; Fe(III) = 1.60; Ni(II) = 1.30; and Zn(II) = 1.10. By means of the flow-through method, a recovery of ca. 100% of the metallic ions adsorbed in a column packed with 2 g of CMCH was found when 5.0 mL of 1.0 mol L-1 hydrochloric acid were used as eluent. An enrichment factor of 20 (100 mt solution containing 50 mu g L-1 of the metallic ions, concentrated to 5.0 mt) was obtained by this preconcentration procedure. The sorption-desorption procedure applied allowed the development of a preconcentration and Flame AAS quantification method of metallic ions in fuel ethanol at trace levels.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Com a finalidade de quantificar o desempenho dos sistemas de debulhamento e limpeza da colhedora Penha CLM-350,, estudou-se as perdas percentuais era grão de milho, ocorridos na saída de palhas, bem como a porcentagem de impurezas, presente no milho ensacado. Tomando-se como 100% os grãos de milho colhidos pelo sistema espigador, determinou-se o valor percentual perdido pelos sistemas de debulhamento e limpeza, bem como a porcentagem de impurezas presente nos grãos de milho ensacado, nos diversos tratamentos estudados. O teor médio de umidade foi de 15,78% (b.u.). Os tratamentos correspondentes ao sistema de debulhamento e limpeza são as velocidades periféricas do debulhador ou as rotações do aspirador em faces da configuração geométrica da máquina. Os resultados obtidos foram estudados através da análise de variância, empregando-se os testes F, aos níveis de 1% e 5% de probabilidade e o teste Tukey, para a comparação estatística entre as médias. A análise estatística para verificar a influência da rotação do aspirador, era relação a porcentagem de grãos de milho perdidos na saída de palhas, mostrou diferenças altamente significativas, podendo-se admitir uma relação direta entre os dois parâmetros nas condições do ensaio. Com relação a rotação do aspirador e a porcentagem de impurezas, presentes nos grãos de milho ensacados, os testes das médias revelaram significância entre os tratamento D (1241,7 rpm) e E (820 rpm) sendo que este último apresentou a maior média. Uma análise mais acurada dos resultados sugere que a porcentagem de impurezas, estaria mais na dependência das relações de fluxo através da colhedora, do que propriamente do regime do aspirador.
Resumo:
Cm vistas a estudar o efeito do sistema de debulhamento na qualidade dos grãos de milho, realizou-se o presente trabalho, onde foram estudados os danos mecânicos sofridos pelos grãos, bem como os danos mecânicos invisíveis, evidenciados pelos testes de germinação. Nos diversos tratamentos estudados, determinou-se a porcentagem de umidade presente nos grãos de milho. Definiu-se a velocidade periférica do debulhador, pelo diâmetro (300 mm) do mesmo e as rotações, para os diversos tratamentos. O delineamento experimental foi de blocos ao acaso com 5 tratamentos e 6 repetições onde foram estudados os valores percentuais de grãos inteiros e quebrados, os teores de umidade correspondentes e os valores de germinação através da análise de variância. Empregou-se o teste F aos níveis de 1% e 5% de probabilidade e o teste Tukey para comparação entre as médias. da análise pode-se concluir que em relação ao teor de umidade dos grãos, os tratamentos não diferiram estatisticamente.
Resumo:
Este trabalho teve como objetivo analisar a metodologia para avaliação do impacto ambiental causado pelo uso de herbicidas no controle de macrófitas. O desenho e a construção dos mesocosmos são descritos em detalhes, como também a forma como foram inseridos lâminas para coleta e medida da comunidade perifítica e sedimento para avaliação da comunidade bentônica. O método utilizado foi o de fluxo contínuo, e vários parâmetros de qualidade de água foram medidos, além da determinação de resíduos na coluna d'água e no sedimento. A intenção de se utilizar um método de fluxo contínuo foi buscar uma situação mais próxima da realidade, a fim de que os resultados obtidos possam espelhar com maior exatidão os possíveis riscos provenientes do uso de substâncias químicas no controle das macrófitas. Alguns ajustes devem ser feitos nessa metodologia para melhor caracterização dos efluentes e calibração do sistema.
Resumo:
Air flow through packed beds was analyzed experimentally under conditions ranging from those that reinforce the effect of the wall on the void fraction to those that minimize it. The packing was spherical particles, with a tube-to-particle diameter ratio (D/dp) between 3 and 60. Air flow rates were maintained between 1.3 and 4.44 m3/min, and gas velocity was measured with a Pitot tube positioned above the bed exit. Measurements were made at various radial and angular coordinate values, allowing the distribution of air flow across the bed to be described in detail. Comparison of the experimentally observed radial profiles with those derived from published equations revealed that at high D/dp ratios the measured and calculated velocity profiles behaved similarly. At low ratios, oscillations in the velocity profiles agreed with those in the voidage profiles, signifying that treating the porous medium as a continuum medium is questionable in these cases.
Resumo:
The synthesis, characterization, and electrochemical study of the Zn(II)-Al(III) and Zn(II)-Cr(III) Layered Double Hydroxides (LDHs) containing 2-thiopenecarboxylate as the interlayer anions are described. The LDHs were prepared by the constant pH coprecipitation technique followed by hydrothermal treatment for 72 h. The materials were analyzed by PXRD, FT-IR, C-13 CP-MAS, EDX, TEM, and CV. The presence of the organic heterocyclic anions was confirmed by FT-IR and the related solid-state C-13 NMR data strongly suggested that these were dimerised during coprecipitation. Accordingly, the basal spacing found by the X-ray technique was similar to 15.3 Angstrom, a distance coincident with the formation of bilayers of the intercalated anions. The structural organization of all the new materials was greatly enhanced by hydrothermal treatment, as shown by PXRD. The improved organization of the bilayered structures had a strong influence in the electrochemical behaviour of clay-modified electrodes produced with these materials, such as the diminished resistance to the ionic flow through the LDHs films. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
Classical shell-and-tube heat exchangers are usually equipped with segmental baffles. These baffles serve two basic functions: (a) they provide tube supports, thereby preventing or reducing mechanical problems, such as sagging or vibration; (b) they direct the fluid flow over the tubes so as to introduce a cross-flow component, thereby increasing the heat transfer. Segmented baffles have several sources of performance loss, some due to various leakage flows and others caused by stagnation zones. A new concept of longitudinal flow heat exchanger - based on placing twisted tapes along the tube bundle subchannels - was developed to mitigate drawbacks of other types of tubular heat exchangers. In this paper, a numerical model has been implemented in order to simulate the thermal-hydraulic feature of tubular heat exchangers equipped either with segmental baffles or with subchannel twisted tapes. The tube bundle has been described by means of an equivalent porous medium type model, allowing a macroscopic description of the shell-side flow. The basic equations - continuity, momentum and energy - have been solved by using the finite volume method. Typical numerical results have been compared with experimental data, reaching a very good agreement. A comparative analysis of different types of heat exchangers has been carried out, revealing the satisfactory thermal-hydraulic efficiency level of the twisted tapes heat exchangers.