942 resultados para FAILURE ANALYSIS


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Partial-thickness tears of the supraspinatus tendon frequently occur at its insertion on the greater tubercule of the humerus, causing pain and reduced strength and range of motion. The goal of this work was to quantify the loss of loading capacity due to tendon tears at the insertion area. A finite element model of the supraspinatus tendon was developed using in vivo magnetic resonance images data. The tendon was represented by an anisotropic hyperelastic constitutive law identified with experimental measurements. A failure criterion was proposed and calibrated with experimental data. A partial-thickness tear was gradually increased, starting from the deep articular-sided fibres. For different values of tendon tear thickness, the tendon was mechanically loaded up to failure. The numerical model predicted a loss in loading capacity of the tendon as the tear thickness progressed. Tendon failure was more likely when the tendon tear exceeded 20%. The predictions of the model were consistent with experimental studies. Partial-thickness tears below 40% tear are sufficiently stable to persist physiotherapeutic exercises. Above 60% tear surgery should be considered to restore shoulder strength.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND & AIMS: The prognostic value of the different causes of renal failure in cirrhosis is not well established. This study investigated the predictive value of the cause of renal failure in cirrhosis. METHODS: Five hundred sixty-two consecutive patients with cirrhosis and renal failure (as defined by serum creatinine 1.5 mg/dL on 2 successive determinations within 48 hours) hospitalized over a 6-year period in a single institution were included in a prospective study. The cause of renal failure was classified into 4 groups: renal failure associated with bacterial infections, renal failure associated with volume depletion, hepatorenal syndrome (HRS), and parenchymal nephropathy. The primary end point was survival at 3 months. RESULTS: Four hundred sixty-three patients (82.4%) had renal failure that could be classified in 1 of 4 groups. The most frequent was renal failure associated with infections (213 cases; 46%), followed by hypovolemia-associated renal failure (149; 32%), HRS (60; 13%), and parenchymal nephropathy (41; 9%). The remaining patients had a combination of causes or miscellaneous conditions. Prognosis was markedly different according to cause of renal failure, 3-month probability of survival being 73% for parenchymal nephropathy, 46% for hypovolemia-associated renal failure, 31% for renal failure associated with infections, and 15% for HRS (P .0005). In a multivariate analysis adjusted for potentially confounding variables, cause of renal failure was independently associated with prognosis, together with MELD score, serum sodium, and hepatic encephalopathy at time of diagnosis of renal failure. CONCLUSIONS: A simple classification of patients with cirrhosis according to cause of renal failure is useful in assessment of prognosis and may help in decision making in liver transplantation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis concentrates on developing a practical local approach methodology based on micro mechanical models for the analysis of ductile fracture of welded joints. Two major problems involved in the local approach, namely the dilational constitutive relation reflecting the softening behaviour of material, and the failure criterion associated with the constitutive equation, have been studied in detail. Firstly, considerable efforts were made on the numerical integration and computer implementation for the non trivial dilational Gurson Tvergaard model. Considering the weaknesses of the widely used Euler forward integration algorithms, a family of generalized mid point algorithms is proposed for the Gurson Tvergaard model. Correspondingly, based on the decomposition of stresses into hydrostatic and deviatoric parts, an explicit seven parameter expression for the consistent tangent moduli of the algorithms is presented. This explicit formula avoids any matrix inversion during numerical iteration and thus greatly facilitates the computer implementation of the algorithms and increase the efficiency of the code. The accuracy of the proposed algorithms and other conventional algorithms has been assessed in a systematic manner in order to highlight the best algorithm for this study. The accurate and efficient performance of present finite element implementation of the proposed algorithms has been demonstrated by various numerical examples. It has been found that the true mid point algorithm (a = 0.5) is the most accurate one when the deviatoric strain increment is radial to the yield surface and it is very important to use the consistent tangent moduli in the Newton iteration procedure. Secondly, an assessment of the consistency of current local failure criteria for ductile fracture, the critical void growth criterion, the constant critical void volume fraction criterion and Thomason's plastic limit load failure criterion, has been made. Significant differences in the predictions of ductility by the three criteria were found. By assuming the void grows spherically and using the void volume fraction from the Gurson Tvergaard model to calculate the current void matrix geometry, Thomason's failure criterion has been modified and a new failure criterion for the Gurson Tvergaard model is presented. Comparison with Koplik and Needleman's finite element results shows that the new failure criterion is fairly accurate indeed. A novel feature of the new failure criterion is that a mechanism for void coalescence is incorporated into the constitutive model. Hence the material failure is a natural result of the development of macroscopic plastic flow and the microscopic internal necking mechanism. By the new failure criterion, the critical void volume fraction is not a material constant and the initial void volume fraction and/or void nucleation parameters essentially control the material failure. This feature is very desirable and makes the numerical calibration of void nucleation parameters(s) possible and physically sound. Thirdly, a local approach methodology based on the above two major contributions has been built up in ABAQUS via the user material subroutine UMAT and applied to welded T joints. By using the void nucleation parameters calibrated from simple smooth and notched specimens, it was found that the fracture behaviour of the welded T joints can be well predicted using present methodology. This application has shown how the damage parameters of both base material and heat affected zone (HAZ) material can be obtained in a step by step manner and how useful and capable the local approach methodology is in the analysis of fracture behaviour and crack development as well as structural integrity assessment of practical problems where non homogeneous materials are involved. Finally, a procedure for the possible engineering application of the present methodology is suggested and discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Due to functional requirement of a structural detail brackets with and without scallop are frequently used in bridges, decks, ships and offshore structure. Scallops are designed to serve as passage way for fluids, to reduce weld length and plate distortions. Moreover, scallops are used to avoid intersection of two or more welds for the fact that there is the presence of inventible inherent initial crack except for full penetrated weld and the formation of multi-axial stress state at the weld intersection. Welding all around the scallop corner increase the possibility of brittle fracture even for the case the bracket is not loaded by primary load. Avoiding of scallop will establish an initial crack in the corner if bracket is welded by fillet welds. If the two weld run pass had crossed, this would have given a 3D residual stress situation. Therefore the presences and absence of scallop necessitates the 3D FEA fatigue resistance of both types of brackets using effective notch stress approach ( ). FEMAP 10.1 with NX NASTRAN was used for the 3D FEA. The first and main objective of this research was to investigate and compare the fatigue resistance of brackets with and without scallop. The secondary goal was the fatigue design of scallops in case they cannot be avoided for some reason. The fatigue resistance for both types of brackets was determined based on approach using 1 mm fictitiously rounded radius based on IIW recommendation. Identical geometrical, boundary and loading conditions were used for the determination and comparison of fatigue resistance of both types of brackets using linear 3D FEA. Moreover the size effect of bracket length was also studied using 2D SHELL element FEA. In the case of brackets with scallop the flange plate weld toe at the corner of the scallop was found to exhibit the highest and made the flange plate weld toe critical for fatigue failure. Whereas weld root and weld toe at the weld intersections were the highly stressed location for brackets without scallop. Thus weld toe for brackets with scallop, and weld root and weld toe for brackets without scallop were found to be the critical area for fatigue failure. Employing identical parameters on both types of brackets, brackets without scallop had the highest except for full penetrated weld. Furthermore the fatigue resistance of brackets without scallop was highly affected by the lack of weld penetration length and it was found out that decreased as the weld penetration was increased. Despite the fact that the very presence of scallop reduces the stiffness and also same time induce stress concentration, based on the 3D FEA it is worth concluding that using scallop provided better fatigue resistance when both types of brackets were fillet welded. However brackets without scallop had the highest fatigue resistance when full penetration weld was used. This thesis also showed that weld toe for brackets with scallop was the only highly stressed area unlike brackets without scallop in which both weld toe and weld root were the critical locations for fatigue failure when different types of boundary conditions were used. Weld throat thickness, plate thickness, scallop radius, lack of weld penetration length, boundary condition and weld quality affected the fatigue resistance of both types of brackets. And as a result, bracket design procedure, especially welding quality and post weld treatment techniques significantly affect the fatigue resistance of both type of brackets.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Multilevel converters provide an attractive solution to bring the benefits of speed-controlled rotational movement to high-power applications. Therefore, multilevel inverters have attracted wide interest in both the academic community and in the industry for the past two decades. In this doctoral thesis, modulation methods suitable especially for series connected H-bridge multilevel inverters are discussed. A concept of duty cycle modulation is presented and its modification is proposed. These methods are compared with other well-known modulation schemes, such as space-vector pulse width modulation and carrier-based modulation schemes. The advantage of the modified duty-cycle modulation is its algorithmic simplicity. A similar mathematical formulation for the original duty cycle modulation is proposed. The modified duty cycle modulation is shown to produce well-formed phase-to-neutral voltages that have lower total harmonic distortion than the space-vector pulse width modulation and the duty cycle modulation. The space-vector-based solution and the duty cycle modulation, on the other hand, result in a better-quality line-to-line voltage and current waveform. The voltage of the DC links in the modules of the series-connected H-bridge inverter are shown to fluctuate while they are under load. The fluctuation causes inaccuracies in the voltage production, which may result in a failure of the flux estimator in the controller. An extension for upper-level modulation schemes, which changes the switching instants of the inverter so that the output voltage meets the reference voltage accurately regardless of the DC link voltages, is proposed. The method is shown to reduce the error to a very low level when a sufficient switching frequency is used. An appropriate way to organize the switching instants of the multilevel inverter is to make only one-level steps at a time. This causes restrictions on the dynamical features of the modulation schemes. The produced voltage vector cannot be rotated several tens of degrees in a single switching period without violating the above-mentioned one-level-step rule. The dynamical capabilities of multilevel inverters are analyzed in this doctoral thesis, and it is shown that the multilevel inverters are capable of operating even in dynamically demanding metal industry applications. In addition to the discussion on modulation schemes, an overvoltage in multilevel converter drives caused by cable reflection is addressed. The voltage reflection phenomenon in drives with long feeder cables causes premature insulation deterioration and also affects the commonmode voltage, which is one of the main reasons for bearing currents. Bearing currents, on the other hand, cause fluting in the bearings, which results in premature bearing failure. The reflection phenomenon is traditionally prevented by filtering, but in this thesis, a modulationbased filterless method to mitigate the overvoltage in multilevel drives is proposed. Moreover, the mitigation method can be implemented as an extension for upper-level modulation schemes. The method exploits the oscillations caused by two consecutive voltage edges so that the sum of the oscillations results in a mitigated peak of the overvoltage. The applicability of the method is verified by simulations together with experiments with a full-scale prototype.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Diabetes is a rapidly increasing worldwide problem which is characterised by defective metabolism of glucose that causes long-term dysfunction and failure of various organs. The most common complication of diabetes is diabetic retinopathy (DR), which is one of the primary causes of blindness and visual impairment in adults. The rapid increase of diabetes pushes the limits of the current DR screening capabilities for which the digital imaging of the eye fundus (retinal imaging), and automatic or semi-automatic image analysis algorithms provide a potential solution. In this work, the use of colour in the detection of diabetic retinopathy is statistically studied using a supervised algorithm based on one-class classification and Gaussian mixture model estimation. The presented algorithm distinguishes a certain diabetic lesion type from all other possible objects in eye fundus images by only estimating the probability density function of that certain lesion type. For the training and ground truth estimation, the algorithm combines manual annotations of several experts for which the best practices were experimentally selected. By assessing the algorithm’s performance while conducting experiments with the colour space selection, both illuminance and colour correction, and background class information, the use of colour in the detection of diabetic retinopathy was quantitatively evaluated. Another contribution of this work is the benchmarking framework for eye fundus image analysis algorithms needed for the development of the automatic DR detection algorithms. The benchmarking framework provides guidelines on how to construct a benchmarking database that comprises true patient images, ground truth, and an evaluation protocol. The evaluation is based on the standard receiver operating characteristics analysis and it follows the medical practice in the decision making providing protocols for image- and pixel-based evaluations. During the work, two public medical image databases with ground truth were published: DIARETDB0 and DIARETDB1. The framework, DR databases and the final algorithm, are made public in the web to set the baseline results for automatic detection of diabetic retinopathy. Although deviating from the general context of the thesis, a simple and effective optic disc localisation method is presented. The optic disc localisation is discussed, since normal eye fundus structures are fundamental in the characterisation of DR.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the results of subcostal incisional hernia repair using polypropylene mesh, the technical aspects of musculo-aponeurotic reconstruction, routine fixation of supra-aponeurotic mesh and follow-up for five years.METHODS: We conducted a retrospective study that assessed 24 patients undergoing subcostal incisional hernia repair with use of polypropylene mesh; 15 patients (62.5%) were female; ages ranged from 33 to 82, and 79.1% had comorbidities.RESULTS: Early complications: three cases (12.5%) of wound infection, three cases (12.5%) of seroma, one case (4.1%) of hematoma; and one case (4.1%) of wound dehiscence. Late complications occurred in one case (4.1%) of hernia recurrence attributed to technical failure in the fixation of the mesh and in one case (4.1%) of chronic pain. There were no cases of exposure or rejection of the mesh.CONCLUSION: The subcostal incisional hernia, though not very relevant, requires adequate surgical treatment. Its surgical correction involves rebuilding the muscle-aponeurotic defect, supra-aponeurotic fixation of polypropylene mesh, with less complexity and lower rates of complications and recurrences.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Modern machine structures are often fabricated by welding. From a fatigue point of view, the structural details and especially, the welded details are the most prone to fatigue damage and failure. Design against fatigue requires information on the fatigue resistance of a structure’s critical details and the stress loads that act on each detail. Even though, dynamic simulation of flexible bodies is already current method for analyzing structures, obtaining the stress history of a structural detail during dynamic simulation is a challenging task; especially when the detail has a complex geometry. In particular, analyzing the stress history of every structural detail within a single finite element model can be overwhelming since the amount of nodal degrees of freedom needed in the model may require an impractical amount of computational effort. The purpose of computer simulation is to reduce amount of prototypes and speed up the product development process. Also, to take operator influence into account, real time models, i.e. simplified and computationally efficient models are required. This in turn, requires stress computation to be efficient if it will be performed during dynamic simulation. The research looks back at the theoretical background of multibody dynamic simulation and finite element method to find suitable parts to form a new approach for efficient stress calculation. This study proposes that, the problem of stress calculation during dynamic simulation can be greatly simplified by using a combination of floating frame of reference formulation with modal superposition and a sub-modeling approach. In practice, the proposed approach can be used to efficiently generate the relevant fatigue assessment stress history for a structural detail during or after dynamic simulation. In this work numerical examples are presented to demonstrate the proposed approach in practice. The results show that approach is applicable and can be used as proposed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Transportation of fluids is one of the most common and energy intensive processes in the industrial and HVAC sectors. Pumping systems are frequently subject to engineering malpractice when dimensioned, which can lead to poor operational efficiency. Moreover, pump monitoring requires dedicated measuring equipment, which imply costly investments. Inefficient pump operation and improper maintenance can increase energy costs substantially and even lead to pump failure. A centrifugal pump is commonly driven by an induction motor. Driving the induction motor with a frequency converter can diminish energy consumption in pump drives and provide better control of a process. In addition, induction machine signals can also be estimated by modern frequency converters, dispensing with the use of sensors. If the estimates are accurate enough, a pump can be modelled and integrated into the frequency converter control scheme. This can open the possibility of joint motor and pump monitoring and diagnostics, thereby allowing the detection of reliability-reducing operating states that can lead to additional maintenance costs. The goal of this work is to study the accuracy of rotational speed, torque and shaft power estimates calculated by a frequency converter. Laboratory tests were performed in order to observe estimate behaviour in both steady-state and transient operation. An induction machine driven by a vector-controlled frequency converter, coupled with another induction machine acting as load was used in the tests. The estimated quantities were obtained through the frequency converter’s Trend Recorder software. A high-precision, HBM T12 torque-speed transducer was used to measure the actual values of the aforementioned variables. The effect of the flux optimization energy saving feature on the estimate quality was also studied. A processing function was developed in MATLAB for comparison of the obtained data. The obtained results confirm the suitability of this particular converter to provide accurate enough estimates for pumping applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The most common reason for a low-voltage induction motor breakdown is a bearing failure. Along with the increasing popularity of modern frequency converters, bearing failures have become the most important motor fault type. Conditions in which bearing currents are likely to occur are generated as a side effect of fast du/dt switching transients. Once present, different types of bearing currents can accelerate the mechanical wear of bearings by causing deformation of metal parts in the bearing and degradation of the lubricating oil properties.The bearing current phenomena are well known, and several bearing current measurement and mitigation methods have been proposed. Nevertheless, in order to develop more feasible methods to measure and mitigate bearing currents, better knowledge of the phenomena is required. When mechanical wear is caused by bearing currents, the resulting aging impact has to be monitored and dealt with. Moreover, because of the stepwise aging mechanism, periodically executed condition monitoring measurements have been found ineffective. Thus, there is a need for feasible bearing current measurement methods that can be applied in parallel with the normal operation of series production drive systems. In order to reach the objectives of feasibility and applicability, nonintrusive measurement methods are preferred. In this doctoral dissertation, the characteristics and conditions of bearings that are related to the occurrence of different kinds of bearing currents are studied. Further, the study introduces some nonintrusive radio-frequency-signal-based approaches to detect and measure parameters that are associated with the accelerated bearing wear caused by bearing currents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Helicobacter pylori (HP) infection is endemic worldwide. The proposed treatment is expensive and there are few reports regarding reinfection rates in Brazil. The aim of this study was to compare the eradication rates obtained with two therapeutic options and to evaluate reinfection one year after treatment. This was a prospective randomized trial with 55 patients. Thirty-nine patients had active duodenal ulcer (DU) and 16 non-ulcer dyspepsia (NUD), and all tested positive for HP. Diagnosis was based on at least two positive tests: ultrarapid urease test, histology and/or culture. Patients were randomized to two groups: group OMC treated with 40 mg omeprazole (once a day), 500 mg metronidazole and 250 mg clarithromycin (twice daily) for 7 days, or group NA treated with 300 mg nizatidine (once a day) and 1000 mg amoxicillin (twice daily) for 14 days. Those patients in whom HP was eradicated were followed up for one year to evaluate reinfection. Twenty-five patients were randomized for OMC and 30 for NA. HP eradication occurred in 20/25 patients (80%) treated with OMC and 13/30 (43%) treated with NA (P = 0.01). After reallocation because of initial treatment failure, the overall eradication rate was 44/51 patients (86%). After an average follow-up of one year, we evaluated 34 patients (23 with DU and 11 with NUD). Reinfection occurred in 3/34 patients (7.6%). We conclude that OMC is effective for HP eradication, and that NA should not be used. Reinfection occurs in 7.6% of the patients in the first year after eradication.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Several studies show the ability of macrophages to remove particles injected into the bloodstream. This function seems to be increased in the presence of acute renal failure. The objective of the present study was to assess the phagocytic function of the main organs (spleen, liver and lung) of the mononuclear phagocytic system in renal and postrenal failures. Fifteen rats (250-350 g) were divided into three groups (N = 5): group I - control; group II - ligature of both ureters, and group III - bilateral nephrectomy. On the third postoperative day, all animals received an iv injection of 1 ml/kg 99mTc sulfur colloid. Blood samples were collected for the assessment of plasma urea, creatinine, sodium, and potassium concentrations and arterial gasometry. Samples of liver, spleen, lung and blood clots were obtained and radioactivity was measured. Samples of liver, spleen, lung and kidney were prepared for routine histopathological analysis. Plasma urea, creatinine and potassium concentrations in groups II and III were higher than in group I (P<0.05). Plasma sodium concentrations in groups II and III were lower than in group I (P<0.05). Compensated metabolic acidosis was observed in the presence of postrenal failure. Group II animals showed a lower level of radioactivity in the spleen (0.98) and lung (2.63), and a higher level in the liver (105.51) than control. Group III animals showed a lower level of radioactivity in the spleen (11.94) and a higher level in the liver (61.80), lung (11.30) and blood clot (5.13) than control. In groups II and III liver steatosis and bronchopneumonia were observed. Renal and postrenal failures seem to interfere with blood clearance by the mononuclear phagocytic system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the aim of investigating the presence of latent inflammatory process in the lungs of patients with Crohn's disease, 15 patients with Crohn's disease were evaluated by spirometry, the methacholine challenge test, induced sputum, and skin tests for inhaled antigens. Serum IgE, erythrocyte sedimentation rate and hematocrit were also determined. The patients were compared with 20 healthy controls by the Mann-Whitney and Fisher exact tests. Their respiratory physical examination was normal. None had a personal or family history of clinical atopy. None had a previous history of pulmonary disease, smoking or toxic bronchopulmonary exposure. None had sinusitis, migraine, diabetes mellitus, or cardiac failure. Four (26.6%) of the patients with Crohn's disease had a positive methacholine challenge test whereas none of the 20 controls had a positive methacholine test (P = 0.026, Fisher exact test). Patients with Crohn's disease had a higher level of lymphocytes in induced sputum than controls (mean 14.59%, range 3.2-50 vs 5.46%, 0-26.92%, respectively; P = 0.011, Mann-Whitney test). Patients with Crohn's disease and a positive methacholine challenge test had an even higher percentage of lymphocytes in induced sputum compared with patients with Crohn's disease and a negative methacholine test (mean 24.88%, range 12.87-50 vs 10.48%, 3.2-21.69%; P = 0.047, Mann-Whitney test). The simultaneous findings of bronchopulmonary lymphocytosis and bronchial hyperresponsiveness in patients with Crohn's disease were not reported up to now. These results suggest that patients with Crohn's disease present a subclinical inflammatory process despite the absence of pulmonary symptoms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of the present study was to assess the incidence, risk factors and outcome of patients who develop acute renal failure (ARF) in intensive care units. In this prospective observational study, 221 patients with a 48-h minimum stay, 18-year-old minimum age and absence of overt acute or chronic renal failure were included. Exclusion criteria were organ donors and renal transplantation patients. ARF was defined as a creatinine level above 1.5 mg/dL. Statistics were performed using Pearsons' chi2 test, Student t-test, and Wilcoxon test. Multivariate analysis was run using all variables with P < 0.1 in the univariate analysis. ARF developed in 19.0% of the patients, with 76.19% resulting in death. Main risk factors (univariate analysis) were: higher intra-operative hydration and bleeding, higher death risk by APACHE II score, logist organ dysfunction system on the first day, mechanical ventilation, shock due to systemic inflammatory response syndrome (SIRS)/sepsis, noradrenaline use, and plasma creatinine and urea levels on admission. Heart rate on admission (OR = 1.023 (1.002-1.044)), male gender (OR = 4.275 (1.340-13642)), shock due to SIRS/sepsis (OR = 8.590 (2.710-27.229)), higher intra-operative hydration (OR = 1.002 (1.000-1004)), and plasma urea on admission (OR = 1.012 (0.980-1044)) remained significant (multivariate analysis). The mortality risk factors (univariate analysis) were shock due to SIRS/sepsis, mechanical ventilation, blood stream infection, potassium and bicarbonate levels. Only potassium levels remained significant (P = 0.037). In conclusion, ARF has a high incidence, morbidity and mortality when it occurs in intensive care unit. There is a very close association with hemodynamic status and multiple organ dysfunction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pregnancy loss can be caused by several factors involved in human reproduction. Although up to 50% of cases remain unexplained, it has been postulated that the major cause of failed pregnancy is an error of embryo implantation. Transmembrane mucin-1 (MUC-1) is a glycoprotein expressed on the endometrial cell surface which acts as a barrier to implantation. The gene that codes for this molecule is composed of a polymorphic tandem repeat of 60 nucleotides. Our objective was to determine if MUC-1 genetic polymorphism is associated with implantation failure in patients with a history of recurrent abortion. The study was conducted on 10 women aged 25 to 35 years with no history of successful pregnancy and with a diagnosis of infertility. The control group consisted of 32 patients aged 25 to 35 years who had delivered at least two full-term live children and who had no history of abortions or fetal losses. MUC-1 amplicons were obtained by PCR and observed on agarose and polyacrylamide gel after electrophoresis. Statistical analysis showed no significant difference in the number of MUC-1 variable number of tandem repeats between these groups (P > 0.05). Our results suggest that there is no effect of the polymorphic MUC-1 sequence on the implantation failure. However, the data do not exclude MUC-1 relevance during embryo implantation. The process is related to several associated factors such as the mechanisms of gene expression in the uterus, specific MUC-1 post-translational modifications and appropriate interactions with other molecules during embryo implantation.