693 resultados para Endoscopic ampullectomy
Resumo:
Objectives The objective of this article is to describe the development of an anatomically accurate simulator in order to aid the training of a perinatal team in the insertion and removal of a fetal endoscopic tracheal occlusion (FETO) balloon in the management of prenatally diagnosed congenital diaphragmatic hernia. Methods An experienced perinatal team collaborated with a medical sculptor to design a fetal model for the FETO procedure. Measurements derived from 28-week fetal magnetic resonance imaging were used in the development of an anatomically precise simulated airway within a silicone rubber preterm fetal model. Clinician feedback was then used to guide multiple iterations of the model with serial improvements in the anatomic accuracy of the simulator airway. Results An appropriately sized preterm fetal mannequin with a high-fidelity airway was developed. The team used this model to develop surgical skills with balloon insertion, and removal, and to prepare the team for an integrated response to unanticipated delivery with the FETO balloon still in situ. Conclusions This fetal mannequin aided in the ability of a fetal therapy unit to offer the FETO procedure at their center for the first time. This model may be of benefit to other perinatal centers planning to offer this procedure.
Resumo:
Endoscopy constitutes an important investigation in the presence of a gastro-oesophageal reflux. The primary intention is to exclude the possibility of an organic pathology, for example cancer, which has not been demonstrated by other investigative procedures. Accordingly it must provide a detailed exploration of the whole superior digestive tract, from the mouth to the duodenum. Secondly, endoscopy must establish the consequence of the reflux on the mucosa of the lower oesophagus both by a macroscopic and a detailed microscopic description. Peptic lesions are classified according to 4 degrees of severity. The difficulty in evaluating the very early lesions (1st degree) and the advanced stages (4th degree) necessitates systematic biopsies of the lesions. The erythroplasic type of carcinoma in situ can present the same endoscopic changes as a 1st degree peptic lesion, whereas the exclusion of an adenocarcinoma constitutes the major preoccupation at the time of endoscopy of a 4th degree oesophagitis.
Resumo:
The practice of sedation, including monitoring practice for digestive endoscopy, continues to evolve throughout the world. In many countries, including Switzerland, there is a trend towards increased utilization of sedation during both routine and advanced endoscopic procedures. Sedation improves patient satisfaction with endoscopy and also improves the quality of the examination. In addition, a trend can be observed towards an increasing use of propofol as the preferred sedative drug. Here we review the latest published data from surveys describing sedation and monitoring practice in different countries and compare them with our own data from successive nationwide surveys among Swiss gastroenterologists over a period of 20 years. This development between these socioeconomically very similar Western industrialized countries, however, shows some unique and surprising differences. In Germany and Switzerland, propofol use has become increasingly widespread, in Switzerland even to the extent that during the last few years propofol has overtaken benzodiazepine sedation, with an absolute majority of Swiss gastroenterologists using it without the assistance of an anesthesiologist. In addition, the change in Switzerland reflects a successful generalization of nonanesthesiologist-administered propofol (NAAP) sedation from the hospital setting to private practice.
Resumo:
OBJECTIVE: To correlate the postoperative voice outcome to preoperative glottic involvement, following partial cricotracheal resection (PCTR) in children. The glottic involvement was analysed based on the extent of subglottic stenosis (SGS) in the endoscopic image and functional dynamic assessment using flexible endoscopy. METHODS: We conducted an interobserver study in which two ENT surgeons, blinded to one another's interpretation, independently rated the extent of SGS based on the endoscopic image along with the dynamic functional airway assessment, of 108 children who underwent PCTR for grade III or IV stenosis. Based on the observation, the glottic involvement was rated into 4 categories: Evaluation of the voice was based on a parent/patient proxy questionnaire sent in 2008 to assess the current functional status of the patient's voice. RESULTS: Among the 77 patients available for long-term outcome with a minimum 1-year follow-up, 31 patients had isolated SGS free from vocal cords (group A) and 30 had SGS reaching the under surface of vocal cords with partial or no impairment of abduction of vocal cords (group B). Twelve patients belonged to group C with posterior glottic stenosis and/or vocal cord fusion (without cricoarytenoid ankylosis) and 4 patients had transglottic stenosis and or/bilateral cricoarytenoid ankylosis (group D). The long-term voice outcome following PCTR as perceived by the parent or patient was normal in 18% (14 of 77 patients) and the remaining 63 patients demonstrated mild to severe dysphonia. Patients belonging to group A and B exhibited either normal voice or mild dysphonia. Patients in group C demonstrated dysphonia, which was moderate in severity in the majority (83%). All patients in group D with transglottic stenosis and/or CAA showed severe dysphonia. CONCLUSION: Children with associated glottic involvement are at high risk for poor voice outcome following PCTR. The severity of dysphonia was found to be proportional to the preoperative glottic involvement. Preoperative rating of the extent of glottic involvement based on endoscopic image and dynamic assessment was found to be useful in prognosticating the voice outcome.
Resumo:
Eosinophilic esophagitis is a recent diagnosis, of growing interest and prevalence. It has to be considered by every physician when facing any adult or pediatric case of dysphagia, food impaction, and symptoms of GERD (gastroesophageal reflux disease) resistant to proton-pump inhibitor treatment. The diagnosis is made by combining clinical symptoms and endoscopic signs, supported by biopsies of the mucosa, which should show more than 15 eosinophils per high power field. The etiology seems to be of allergic origin, and a full immuno-allergic testing should be made. Recommendations for the treatment are to calm down the inflammatory process by proton-pump inhibitors, and to give topical steroids, keeping the systemic treatment for acute severe cases. In cases of esophageal stenoses, dilations can be undertaken, but with a high risk of recurrence.
Resumo:
BACKGROUND: The aim of our study was to assess the feasibility of minimally invasive digestive anastomosis using a modular flexible magnetic anastomotic device made up of a set of two flexible chains of magnetic elements. The assembly possesses a non-deployed linear configuration which allows it to be introduced through a dedicated small-sized applicator into the bowel where it takes the deployed form. A centering suture allows the mating between the two parts to be controlled in order to include the viscerotomy between the two magnetic rings and the connected viscera. METHODS AND PROCEDURES: Eight pigs were involved in a 2-week survival experimental study. In five colorectal anastomoses, the proximal device was inserted by a percutaneous endoscopic technique, and the colon was divided below the magnet. The distal magnet was delivered transanally to connect with the proximal magnet. In three jejunojejunostomies, the first magnetic chain was injected in its linear configuration through a small enterotomy. Once delivered, the device self-assembled into a ring shape. A second magnet was injected more distally through the same port. The centering sutures were tied together extracorporeally and, using a knot pusher, magnets were connected. Ex vivo strain testing to determine the compression force delivered by the magnetic device, burst pressure of the anastomosis, and histology were performed. RESULTS: Mean operative time including endoscopy was 69.2 ± 21.9 min, and average time to full patency was 5 days for colorectal anastomosis. Operative times for jejunojejunostomies were 125, 80, and 35 min, respectively. The postoperative period was uneventful. Burst pressure of all anastomoses was ≥ 110 mmHg. Mean strain force to detach the devices was 6.1 ± 0.98 and 12.88 ± 1.34 N in colorectal and jejunojejunal connections, respectively. Pathology showed a mild-to-moderate inflammation score. CONCLUSIONS: The modular magnetic system showed enormous potential to create minimally invasive digestive anastomoses, and may represent an alternative to stapled anastomoses, being easy to deliver, effective, and low cost.
Resumo:
BACKGROUND: Prospective data describing the appropriateness of use of colonoscopy based on detailed panel-based clinical criteria are not available. METHODS: In a cohort of 553 consecutive patients referred for colonoscopy to two university-based Swiss outpatient clinics, the percentage of patients who underwent colonoscopy for appropriate, equivocal, and inappropriate indications and the relationship between appropriateness of use and the presence of relevant endoscopic lesions was prospectively assessed. This assessment was based on criteria of the American Society for Gastrointestinal Endoscopy and explicit American and Swiss criteria developed in 1994 by a formal panel process using the RAND/UCLA appropriateness method. RESULTS: The procedures were rated appropriate or equivocal in 72.2% by criteria of the American Society for Gastrointestinal Endoscopy, in 68.5% by explicit American criteria, and in 74.4% by explicit Swiss criteria (not statistically significant, NS). Inappropriate use (overuse) of colonoscopy was found in 27.8%, 31.5%, and 25.6%, respectively (NS). The proportion of appropriate procedures was higher with increasing age. Almost all reasons for using colonoscopy could be assessed by the two explicit criteria sets, whereas 28.4% of reasons for using colonoscopy could not be evaluated by the criteria of the American Society for Gastrointestinal Endoscopy (p < 0.0001). The probability of finding a relevant endoscopic lesion was distinctly higher in the procedures rated appropriate or equivocal than in procedures judged inappropriate. CONCLUSIONS: The rate of inappropriate use of colonoscopy is substantial in Switzerland. Explicit criteria allow assessment of almost all indications encountered in clinical practice. In this study, all sets of appropriateness criteria significantly enhanced the probability of finding a relevant endoscopic lesion during colonoscopy.
Resumo:
BACKGROUND: Gastroesophageal reflux and progressive esophageal dilatation can develop after gastric banding (GB). HYPOTHESIS: Gastric banding may interfere with esophageal motility, enhance reflux, or promote esophageal dilatation. DESIGN: Before-after trial in patients undergoing GB. SETTING: University teaching hospital. PATIENTS AND METHODS: Between January 1999 and August 2002, 43 patients undergoing laparoscopic GB for morbid obesity underwent upper gastrointestinal endoscopy, 24-hour pH monitoring, and stationary esophageal manometry before GB and between 6 and 18 months postoperatively. MAIN OUTCOME MEASURES: Reflux symptoms, endoscopic esophagitis, pressures measured at manometry, esophageal acid exposure. RESULTS: There was no difference in the prevalence of reflux symptoms or esophagitis before and after GB. The lower esophageal sphincter was unaffected by surgery, but contractions in the lower esophagus weakened after GB, in correlation with preoperative values. There was a trend toward more postoperative nonspecific motility disorders. Esophageal acid exposure tended to decrease after GB, with fewer reflux episodes. A few patients developed massive postoperative reflux. There was no clear correlation between preoperative testing and postoperative esophageal acid exposure, although patients with abnormal preoperative acid exposure tended to maintain high values after GB. CONCLUSIONS: Postoperative esophageal dysmotility and gastroesophageal reflux are not uncommon after GB. Preoperative testing should be done routinely. Low amplitude of contraction in the lower esophagus and increased esophageal acid exposure should be regarded as contraindications to GB. Patients with such findings should be offered an alternative procedure, such as Roux-en-Y gastric bypass.
Resumo:
NFAT transcription factors control T-cell activation and function. Specifically, the transcription factor NFATc2 affects the regulation of cell differentiation and growth and plays a critical role in the development of colonic inflammation. Here, we used an experimental model of colitis-associated colorectal carcinoma to investigate the contribution of NFATc2 to the promotion of colonic tumors. Compared with wild-type animals that readily presented with multiple colon tumors, NFATc2-deficient mice were protected from tumor development. This observed decrease in colonic tumor progression was associated with reduced endoscopic inflammation, increased apoptosis of lamina propria T lymphocytes, and significantly reduced levels of the critical proinflammatory cytokines interleukin (IL)-21 and IL-6. Administration of hyper IL-6 abrogated protection from tumor progression in NFATc2-knockout mice and restored tumor incidence to control levels. Taken together, our findings highlight a pivotal role for NFATc2 in the establishment of inflammation-associated colorectal tumors mediated by control of IL-6 expression. Cancer Res; 72(17); 4340-50. ©2012 AACR.
Resumo:
Stents have a long history in traditional valve surgery as both, porcine biological valves as well as pericardial valves are mounted on stents prior to implantation. Recently stent-mounted biological devices have been compressed up to the point, where they can be passed through a catheter. Various routes can be distinguished for implantation: open access, the trans-vascular route in antegrade or retrograde fashion, as well as direct trans-apical or trans-atrial access. Direct access has the potentialforvideo-endoscopic valve replacement. In theory, as well as in the experimental setting, valved stents have been implanted in tricuspid and caval position respectively, as well as in pulmonary, mitral and aortic locations. The largest clinical experience has been achieved in pulmonary position whereas current efforts target the aortic position.
Resumo:
Meningitis due to Streptococcus pneumoniae is a rare complication of trans-sphenoidal surgery. We present the case of a patient who developed pneumococcal meningitis with associated bacteraemia after elective endoscopic trans-sphenoidal resection of a pituitary macro-adenoma. After initial treatment with ceftriaxone and dexamethasone, the patient made a good recovery and dexamethasone was discontinued. Two days later the patient's condition deteriorated rapidly, presenting focal and diffuse neurological deficits. Cerebral MRI revealed widespread punctate ischaemic-type lesions affecting both anterior and posterior vascular territories bilaterally and involving features consistent with cerebral vasculitis. Antibiotic treatment was broadened to include meropenem and dexamethasone was restarted, but the patient remained in a comatose state and died 14 days later. Steroid treatment may play a dual role in this poorly characterised infectious complication of trans-sphenoidal pituitary surgery. This possibility is discussed and the options for prophylaxis are reviewed.
Resumo:
BACKGROUND & AIMS: Standardized instruments are needed to assess the activity of eosinophilic esophagitis (EoE) and to provide end points for clinical trials and observational studies. We aimed to develop and validate a patient-reported outcome (PRO) instrument and score, based on items that could account for variations in patient assessments of disease severity. We also evaluated relationships between patient assessment of disease severity and EoE-associated endoscopic, histologic, and laboratory findings. METHODS: We collected information from 186 patients with EoE in Switzerland and the United States (69.4% male; median age, 43 y) via surveys (n = 135), focus groups (n = 27), and semistructured interviews (n = 24). Items were generated for the instruments to assess biologic activity based on physician input. Linear regression was used to quantify the extent to which variations in patient-reported disease characteristics could account for variations in patient assessment of EoE severity. The PRO instrument was used prospectively in 153 adult patients with EoE (72.5% male; median age, 38 y), and validated in an independent group of 120 patients with EoE (60.8% male; median age, 40.5 y). RESULTS: Seven PRO factors that are used to assess characteristics of dysphagia, behavioral adaptations to living with dysphagia, and pain while swallowing accounted for 67% of the variation in patient assessment of disease severity. Based on statistical consideration and patient input, a 7-day recall period was selected. Highly active EoE, based on endoscopic and histologic findings, was associated with an increase in patient-assessed disease severity. In the validation study, the mean difference between patient assessment of EoE severity (range, 0-10) and PRO score (range, 0-8.52) was 0.15. CONCLUSIONS: We developed and validated an EoE scoring system based on 7 PRO items that assess symptoms over a 7-day recall period. Clinicaltrials.gov number: NCT00939263.
Resumo:
Objective: To implement a carotid sparing protocol using helical Tomotherapy(HT) in T1N0 squamous-cell laryngeal carcinoma.Materials/Methods: Between July and August 2010, 7 men with stage T1N0 laryngeal carcinoma were included in this study. Age ranged from 47-74 years. Staging included endoscopic examination, CT-scan and MRI when indicated.Planned irradiation dose was 70 Gy in 35 fractions over 7 weeks. A simple treatment planning algorithm for carotidsparing was used: maximum point dose to the carotids 35 Gy, to the spinal cord 30 Gy, and 100% PTV volume to becovered with 95% of the prescribed dose. Carotid volume of interest extended to 1 cm above and below of the PTV.Doses to the carotid arteries, critical organs, and planned target volume (PTV) with our standard laryngealirradiation protocol was compared. Daily megavoltage scans were obtained before each fraction. When necessary, thePlanned Adaptive? software (TomoTherapy Inc., Madison, WI) was used to evaluate the need for a re-planning,which has never been indicated. Dose data were extracted using the VelocityAI software (Atlanta, GA), and datanormalization and dosevolume histogram (DVH) interpolation were realized using the Igor Pro software (Portland,OR).Results: A significant (p < 0.05) carotid dose sparing compared to our standard protocol with an average maximum point dose of 38.3 Gy (standard devaition [SD] 4.05 Gy), average mean dose of 18.59 Gy (SD 0.83 Gy) was achieved.In all patients, 95% of the carotid volume received less than 28.4 Gy (SD 0.98 Gy). The average maximum point doseto the spinal cord was 25.8 Gy (SD 3.24 Gy). PTV was fully covered with more than 95% of the prescribed dose forall patients with an average maximum point dose of 74.1 Gy and the absolute maximum dose in a single patient of75.2 Gy. To date, the clinical outcomes have been excellent. Three patients (42%) developed stage 1 mucositis that was conservatively managed, and all the patients presented a mild to moderate dysphonia. All adverse effectsresolved spontaneously in the month following the end of treatment. Early local control rate is 100% considering a 4-5months post treatment follow-up.Conclusions: HT allows a clinically significant decrease of carotid irradiation dose compared tostandard irradiation protocols with an acceptable spinal cord dose tradeoff. Moreover, this technique allows the PTV to be homogenously covered with a curative irradiation dose. Daily control imaging brings added security marginsespecially when working with high dose gradients. Further investigations and follow-up are underway to better evaluatethe late clinical outcomes especially the local control rate, late laryngeal and vascular toxicity, and expected potentialimpact on cerebrovascular events.
Resumo:
Urinary incontinence can be treated by endoscopic injection of bulking agents, however, no optimal therapeutic effect has been achieved upon this treatment yet. In the present study, the development of a injectable poly(acrylonitrile) hydrogel paste is described, and its efficacy and histological behavior, once injected into the submucosal space of the minipig bladder, are evaluated. A device was developed to mix poly(acrylonitrile) hydrogel powder with glycerin, used as carrier, prior to injection into the submucosal space of the bladder. Several paste deposits, depending on the size of the bladder, were injected per animal. The implants were harvested at days 7, 14, 21, 28, 84 and 168 and analyzed morphologically and by histology. The persistence of the implants was demonstrated. However, at later time points the implants were split up and surrounded by granulomatous tissue, which was gradually replaced by histiocytes and adipocytes. Transitory focal urothelial metaplasia was observed only at day 7 and moderate foreign body reaction was detected predominantly between the second and fifth week. This study demonstrated the feasibility to develop an injectable paste of poly(acrylonitrile) hydrogel thought to provide the expected bulking effect, necessary for the treatment of urinary incontinence.
Resumo:
Airway stenting is a common endoscopic procedure that is used to treat a variety of central airway lesions. Obstructions or fistulas involving the carina or nearby tracheobronchial structures require the use of specially designed stents, commonly referred to as Y-stents. Conventional methods of endobronchial Y-stent delivery are all characterized by a blind and apneic period during the procedure that carries the risk of stent misplacement or ventilation/oxygenation problems or both. Using combined suspension laryngoscopy, flexible bronchoscopy, and jet ventilation, we describe a technique that makes challenging bronchoscopic interventions--such as self-expandable Y-shaped airway stent delivery--easy, precise, and safe.