958 resultados para Electricity generation performance test
Resumo:
C.E.R.A., a continuous erythropoietin receptor activator, is a new third-generation erythropoiesis-stimulating agent (ESA) that has recently been linked with abuse in endurance sports. In order to combat this new form of doping, we examined an enzyme-linked immunosorbent assay (ELISA) designed to detect the presence of C.E.R.A. in serum samples. The performance of the assay was evaluated using a pilot excretion study that involved six subjects receiving C.E.R.A. Validation data demonstrated an excellent reproducibility and ensured the applicability of the assay for anti-doping purposes. To maximize the chances of detecting the drug in serum samples, we propose the use of this specific ELISA test as a high-throughput screening method, combined with a classic isoelectric focusing test as a confirmatory assay. This strategy should make C.E.R.A. abuse relatively easy to detect, thereby preventing the future use of this drug as a doping agent.
Resumo:
Cannula design is of prime importance for venous drainage during cardiopulmonary bypass (CPB). To evaluate cannulas intended for CPB, an in vitro circuit was set up with silicone tubing between the test cannula encased in a movable preload reservoir and another static reservoir. The pressure-drop (DeltaP) value (P-drainage - P-preload) was measured using Millar pressure transducers. Flow rate (Q) was measured using an ultrasound flowmeter. Data display and data recording were controlled using a LabView application, custom made particularly for our experiments. Our results demonstrated that DeltaP, Q, and cannula resistance (DeltaP/Q) values were significantly decreased when the cannula diameter was increased for Smart and Medtronic cannulas. Smartcanula showed 36% and 43% less resistance compared to Medtronic venous and Medtronic femoral cannulas, respectively. The cannula shape (straight- or curved-tips) did not affect the DLP cannula resistance. Out of five cannulas tested, the Smartcanula outperforms the other commercially available cannulas. The mean (DeltaP/Q) values were 3.3 +/- 0.08, 4.07 +/- 0.08, 5.58 +/- 0.10, 5.74 +/- 0.15, and 6.45 +/- 0.15 for Smart, Medtronic, Edwards, Sarns, and Gambro cannulas, respectively (two-way ANOVA, p < 0.0001). In conclusion, the present assay allows discrimination between different forms of cannula with high or low lumen resistance.
Resumo:
We compared the diagnostic performance characteristics of newly developed method, the rapid dipstick test, which provides colorimetric determination by developing antibody to the lactate dehydrogenase enzyme of parasites, with conventional standard thick-blood film examination. For the rapid test, OptiMAL commercial kits were used. The results were also evaluated with clinical findings from patients. The parasites were determined by microscopic examination of thick-blood films from 81 patients with vivax malaria from southeastern Anatolia, Turkey. The OptiMAL test results were found to be negative in five patients who were diagnosed clinically and through thick-film testing as having vivax malaria. There was no false positivity observed with the OptiMAL test. We concluded that this rapid malaria test has a lower level of sensitivity than the classical thick-blood-film test for malaria, but that these methods have equal specificity.
Resumo:
Paracoccidioidomycosis is diagnosed from the direct observation of the causative agent, but serology can facilitate and decrease the time required for diagnosis. The objective of this study was to determine the influence of serum sample inactivation on the performance of the latex agglutination test (LAT) for detecting antibodies against Paracoccidioides brasiliensis. The sensitivity of LAT from inactivated or non-inactivated samples was 73% and 83%, respectively and the LAT selectivity was 79% and 90%, respectively. The LAT evaluated here was no more specific than the double-immunodiffusion assay. We suggest the investigation of other methods for improving the LAT, such as the use of deglycosylated antigen.
Resumo:
Executive Summary Electricity is crucial for modern societies, thus it is important to understand the behaviour of electricity markets in order to be prepared to face the consequences of policy changes. The Swiss electricity market is now in a transition stage from a public monopoly to a liberalised market and it is undergoing an "emergent" liberalisation - i.e. liberalisation taking place without proper regulation. The withdrawal of nuclear capacity is also being debated. These two possible changes directly affect the mechanisms for capacity expansion. Thus, in this thesis we concentrate on understanding the dynamics of capacity expansion in the Swiss electricity market. A conceptual model to help understand the dynamics of capacity expansion in the Swiss electricity market is developed an explained in the first essay. We identify a potential risk of imports dependence. In the second essay a System Dynamics model, based on the conceptual model, is developed to evaluate the consequences of three scenarios: a nuclear phase-out, the implementation of a policy for avoiding imports dependence, and the combination of both. We conclude that the Swiss market is not well prepared to face unexpected changes of supply and demand, and we identify a risk of imports dependence, mainly in the case of a nuclear phase-out. The third essay focus on the opportunity cost of hydro-storage power generation, one of the main generation sources in Switzerland. We use and extended version of our model to test different policies for assigning an opportunity cost to hydro-storage power generation. We conclude that the preferred policies are different for different market participants and depend on market structure.
Resumo:
BACKGROUND: In many countries, primary care physicians determine whether or not older drivers are fit to drive. Little, however, is known regarding the effects of cognitive decline on driving performance and the means to detect it. This study explores to what extent the trail making test (TMT) can provide indications to clinicians about their older patients' on-road driving performance in the context of cognitive decline. METHODS: This translational study was nested within a cohort study and an exploratory psychophysics study. The target population of interest was constituted of older drivers in the absence of important cognitive or physical disorders. We therefore recruited and tested 404 home-dwelling drivers, aged 70 years or more and in possession of valid drivers' licenses, who volunteered to participate in a driving refresher course. Forty-five drivers also agreed to undergo further testing at our lab. On-road driving performance was evaluated by instructors during a 45 minute validated open-road circuit. Drivers were classified as either being excellent, good, moderate, or poor depending on their score on a standardized evaluation of on-road driving performance. RESULTS: The area under the receiver operator curve for detecting poorly performing drivers was 0.668 (CI95% 0.558 to 0.778) for the TMT-A, and 0.662 (CI95% 0.542 to 0.783) for the TMT-B. TMT was related to contrast sensitivity, motion direction, orientation discrimination, working memory, verbal fluency, and literacy. Older patients with a TMT-A ≥ 54 seconds or a TMT-B ≥ 150 seconds have a threefold (CI95% 1.3 to 7.0) increased risk of performing poorly during the on-road evaluation. TMT had a sensitivity of 63.6%, a specificity of 64.9%, a positive predictive value of 9.5%, and a negative predictive value of 96.9%. CONCLUSION: In screening settings, the TMT would have clinicians uselessly consider driving cessation in nine drivers out of ten. Given the important negative impact this could have on older drivers, this study confirms the TMT not to be specific enough for clinicians to justify driving cessation without complementary investigations on driving behaviors.
Resumo:
Education and diagnostic tests capable of early detection represent our most effective means of preventing transmission of human immunodeficiency virus (HIV). The importance of early detection is underlined by studies demonstrating increased life expectancy following early initiation of antiviral treatment. The Elecsys(®) HIV combi PT assay is a fourth-generation antigen-antibody combination assay developed to allow earlier detection of seroconversion, and to have increased sensitivity and improved specificity. We aimed to determine how early the assay could detect infection compared with existing assays; whether all HIV variants could be detected; and the assay's specificity using samples from blood donors, routine specimens, and patients with potential cross-reacting factors. Samples were identified as positive by the Elecsys(®) assay 4.9 days after a positive polymerase chain reaction result (as determined by the panel supplier), which was earlier than the 5.3-7.1 days observed with comparators. The analytical sensitivity of the Elecsys(®) HIV combi PT assay for the HIV-1 p24 antigen was 1.05 IU/mL, which compares favorably with the comparator assays. In addition, the Elecsys(®) assay identified all screened HIV subtypes and displayed greater sensitivity to HIV-2 homologous antigen and antibodies to HIV-1 E and O and HIV-2 than the other assays. Overall, the specificity of the Elecsys(®) assay was 99.88 % using samples from blood donors and 99.81 % when analyzing unselected samples. Potential cross-reacting factors did not interfere with assay performance. The Elecsys(®) HIV combi PT assay is a sensitive and specific assay that has been granted the CE mark according to Directive 2009/886/EC.
Resumo:
Selostus: Kasvatushäkin ympäristön vaikutus hopeakettujen käyttäytymiseen
Resumo:
Currently, no standard mix design procedure is available for CIR-emulsion in Iowa. The CIR-foam mix design process developed during the previous phase is applied for CIR-emulsion mixtures with varying emulsified asphalt contents. Dynamic modulus test, dynamic creep test, static creep test and raveling test were conducted to evaluate the short- and long-term performance of CIR-emulsion mixtures at various testing temperatures and loading conditions. A potential benefit of this research is a better understanding of CIR-emulsion material properties in comparison with those of CIR-foam material that would allow for the selection of the most appropriate CIR technology and the type and amount of the optimum stabilization material. Dynamic modulus, flow number and flow time of CIR-emulsion mixtures using CSS-h were generally higher than those of HFMS-2p. Flow number and flow time of CIR-emulsion using RAP materials from Story County was higher than those from Clayton County. Flow number and flow time of CIR-emulsion with 0.5% emulsified asphalt was higher than CIR-emulsion with 1.0% or 1.5%. Raveling loss of CIR-emulsion with 1.5% emulsified was significantly less than those with 0.5% and 1.0%. Test results in terms of dynamic modulus, flow number, flow time and raveling loss of CIR-foam mixtures are generally better than those of CIR-emulsion mixtures. Given the limited RAP sources used for this study, it is recommended that the CIR-emulsion mix design procedure should be validated against several RAP sources and emulsion types.
Resumo:
Currently, no standard mix design procedure is available for CIR-emulsion in Iowa. The CIR-foam mix design process developed during the previous phase is applied for CIR-emulsion mixtures with varying emulsified asphalt contents. Dynamic modulus test, dynamic creep test, static creep test and raveling test were conducted to evaluate the short- and long-term performance of CIR-emulsion mixtures at various testing temperatures and loading conditions. A potential benefit of this research is a better understanding of CIR-emulsion material properties in comparison with those of CIR-foam material that would allow for the selection of the most appropriate CIR technology and the type and amount of the optimum stabilization material. Dynamic modulus, flow number and flow time of CIR-emulsion mixtures using CSS- 1h were generally higher than those of HFMS-2p. Flow number and flow time of CIR-emulsion using RAP materials from Story County was higher than those from Clayton County. Flow number and flow time of CIR-emulsion with 0.5% emulsified asphalt was higher than CIR-emulsion with 1.0% or 1.5%. Raveling loss of CIR-emulsion with 1.5% emulsified was significantly less than those with 0.5% and 1.0%. Test results in terms of dynamic modulus, flow number, flow time and raveling loss of CIR-foam mixtures are generally better than those of CIR-emulsion mixtures. Given the limited RAP sources used for this study, it is recommended that the CIR-emulsion mix design procedure should be validated against several RAP sources and emulsion types.
Resumo:
This report addresses the field testing and analysis of those results to establish the behavior of the original Clive Road Bridge that carried highway traffic over Interstate 80 (I-80) in the northwest region of Des Moines, Iowa. The bridge was load tested in 1959, shortly after its construction and in 1993, just prior to its demolition. This report presents some of the results from both field tests, finite element predictions of the behavior of aluminum bridge girders, and load distribution studies.
Resumo:
The main objective of the Thesis is the description of the electricity distribution networks in Saint-Petersburg area and Stockholm as well. Main similarity and differences in the construction and technicalperformance are presented in the study. Present and future development and investment into the electricity distribution network of OJSC Lenenergo are viewed. The Thesis presents the overview of the power industry reform in Russia. The current state of the electricity distribution sector is described. The study views the participation of the foreign investor "Fortum Power and Heat Oy" inthe development and management of the OJSC Lenenergo. Benchmark comparison of the prices and tangible assets of the main electricity distribution companies in Saint-Petersburg and Stockholm areas is done.
Resumo:
BACKGROUND: The Richalet hypoxia sensitivity test (RT), which quantifies the cardiorespiratory response to acute hypoxia during exercise at an intensity corresponding to a heart rate of ~130 bpm in normoxia, can predict susceptibility of altitude sickness. Its ability to predict exercise performance in hypoxia is unknown. OBJECTIVES: Investigate: (1) whether cerebral blood flow (CBF) and cerebral tissue oxygenation (O2Hb; oxygenated hemoglobin, HHb; deoxygenated hemoglobin) responses during RT predict time-trial cycling (TT) performance in severe hypoxia; (2) if subjects with blunted cardiorespiratory responses during RT show greater impairment of TT performance in severe hypoxia. STUDY DESIGN: Thirteen men [27 ± 7 years (mean ± SD), Wmax: 385 ± 30 W] were evaluated with RT and the results related to two 15 km TT, in normoxia and severe hypoxia (FIO2 = 0.11). RESULTS: During RT, mean middle cerebral artery blood velocity (MCAv: index of CBF) was unaltered with hypoxia at rest (p > 0.05), while it was increased during normoxic (+22 ± 12 %, p < 0.05) and hypoxic exercise (+33 ± 17 %, p < 0.05). Resting hypoxia lowered cerebral O2Hb by 2.2 ± 1.2 μmol (p < 0.05 vs. resting normoxia); hypoxic exercise further lowered it to -7.6 ± 3.1 μmol below baseline (p < 0.05). Cerebral HHb, increased by 3.5 ± 1.8 μmol in resting hypoxia (p < 0.05), and further to 8.5 ± 2.9 μmol in hypoxic exercise (p < 0.05). Changes in CBF and cerebral tissue oxygenation during RT did not correlate with TT performance loss (R = 0.4, p > 0.05 and R = 0.5, p > 0.05, respectively), while tissue oxygenation and SaO2 changes during TT did (R = -0.76, p < 0.05). Significant correlations were observed between SaO2, MCAv and HHb during RT (R = -0.77, -0.76 and 0.84 respectively, p < 0.05 in all cases). CONCLUSIONS: CBF and cerebral tissue oxygenation changes during RT do not predict performance impairment in hypoxia. Since the changes in SaO2 and brain HHb during the TT correlated with performance impairment, the hypothesis that brain oxygenation plays a limiting role for global exercise in conditions of severe hypoxia remains to be tested further.
Resumo:
In distributed energy production, permanent magnet synchronous generators (PMSG) are often connected to the grid via frequency converters, such as voltage source line converters. The price of the converter may constitute a large part of the costs of a generating set. Some of the permanent magnet synchronous generators with converters and traditional separately excited synchronous generators couldbe replaced by direct-on-line (DOL) non-controlled PMSGs. Small directly networkconnected generators are likely to have large markets in the area of distributed electric energy generation. Typical prime movers could be windmills, watermills and internal combustion engines. DOL PMSGs could also be applied in island networks, such as ships and oil platforms. Also various back-up power generating systems could be carried out with DOL PMSGs. The benefits would be a lower priceof the generating set and the robustness and easy use of the system. The performance of DOL PMSGs is analyzed. The electricity distribution companies have regulations that constrain the design of the generators being connected to the grid. The general guidelines and recommendations are applied in the analysis. By analyzing the results produced by the simulation model for the permanent magnet machine, the guidelines for efficient damper winding parameters for DOL PMSGs are presented. The simulation model is used to simulate grid connections and load transients. The damper winding parameters are calculated by the finite element method (FEM) and determined from experimental measurements. Three-dimensional finite element analysis (3D FEA) is carried out. The results from the simulation model and 3D FEA are compared with practical measurements from two prototype axial flux permanent magnet generators provided with damper windings. The dimensioning of the damper winding parameters is case specific. The damper winding should be dimensioned based on the moment of inertia of the generating set. It is shown that the damper winding has optimal values to reach synchronous operation in the shortest period of time after transient operation. With optimal dimensioning, interferenceon the grid is minimized.
Resumo:
Electricity is a strategic service in modern societies. Thus, it is extremely important for governments to be able to guarantee an affordable and reliable supply, which depends to a great extent on an adequate expansion of the generation and transmission capacities. Cross- border integration of electricity markets creates new challenges for the regulators, since the evolution of the market is now influenced by the characteristics and policies of neighbouring countries. There is still no agreement on why and how regions should integrate their electricity markets. The aim of this thesis is to improve the understanding of integrated electricity markets and how their behaviour depends on the prevailing characteristics of the national markets and the policies implemented in each country. We developed a simulation model to analyse under what circumstances integration is desirable. This model is used to study three cases of interconnection between two countries. Several policies regarding interconnection expansion and operation, combined with different generation capacity adequacy mechanisms, are evaluated. The thesis is composed of three papers. The first paper presents a detailed description of the model and an analysis of the case of Colombia and Ecuador. It shows that market coupling can bring important benefits, but the relative size of the countries can lead to import dependency issues in the smaller country. The second paper compares the case of Colombia and Ecuador with the case of Great Britain and France. These countries are significantly different in terms of electricity sources, hydro- storage capacity, complementarity and demand growth. We show that complementarity is essential in order to obtain benefits from integration, while higher demand growth and hydro- storage capacity can lead to counterintuitive outcomes, thus complicating policy design. In the third paper, an extended version of the model presented in the first paper is used to analyse the case of Finland and its interconnection with Russia. Different trading arrangements are considered. We conclude that unless interconnection capacity is expanded, the current trading arrangement, where a single trader owns the transmission rights and limits the flow during peak hours, is beneficial for Finland. In case of interconnection expansion, market coupling would be preferable. We also show that the costs of maintaining a strategic reserve in Finland are justified in order to limit import dependency, while still reaping the benefits of interconnection. In general, we conclude that electricity market integration can bring benefits if the right policies are implemented. However, a large interconnection capacity is only desirable if the countries exhibit significant complementarity and trust each other. The outcomes of policies aimed at guaranteeing security of supply at a national level can be quite counterintuitive due to the interactions between neighbouring countries and their effects on interconnection and generation investments. Thus, it is important for regulators to understand these interactions and coordinate their decisions in order to take advantage of the interconnection without putting security of supply at risk. But it must be taken into account that even when integration brings benefits to the region, some market participants lose and might try to hinder the integration process. -- Dans les sociétés modernes, l'électricité est un service stratégique. Il est donc extrêmement important pour les gouvernements de pouvoir garantir la sécurité d'approvisionnement à des prix abordables. Ceci dépend en grande mesure d'une expansion adéquate des capacités de génération et de transmission. L'intégration des marchés électriques pose des nouveaux défis pour les régulateurs, puisque l'évolution du marché est maintenant influencée par les caractéristiques et les politiques des pays voisins. Il n'est pas encore claire pourquoi ni comment les marches électriques devraient s'intégrer. L'objectif de cette thèse est d'améliorer la compréhension des marchés intégrés d'électricité et de leur comportement en fonction des caractéristiques et politiques de chaque pays. Un modèle de simulation est proposé pour étudier les conditions dans lesquelles l'intégration est désirable. Ce modèle est utilisé pour étudier trois cas d'interconnexion entre deux pays. Plusieurs politiques concernant l'expansion et l'opération de l'interconnexion, combinées avec différents mécanismes de rémunération de la capacité, sont évalués. Cette thèse est compose de trois articles. Le premier présente une description détaillée du modèle et une analyse du cas de la Colombie et de l'Equateur. Il montre que le couplage de marchés peut amener des bénéfices importants ; cependant, la différence de taille entre pays peut créer des soucis de dépendance aux importations pour le pays le plus petit. Le second papier compare le cas de la Colombie et l'Equateur avec le cas de la Grande Bretagne et de la France. Ces pays sont très différents en termes de ressources, taille des réservoirs d'accumulation pour l'hydro, complémentarité et croissance de la demande. Nos résultats montrent que la complémentarité joue un rôle essentiel dans l'obtention des bénéfices potentiels de l'intégration, alors qu'un taux élevé de croissance de la demande, ainsi qu'une grande capacité de stockage, mènent à des résultats contre-intuitifs, ce qui complique les décisions des régulateurs. Dans le troisième article, une extension du modèle présenté dans le premier article est utilisée pour analyser le cas de la Finlande et de la Russie. Différentes règles pour les échanges internationaux d'électricité sont considérées. Nos résultats indiquent qu'à un faible niveau d'interconnexion, la situation actuelle, où un marchand unique possède les droits de transmission et limite le flux pendant les heures de pointe, est bénéfique pour la Finlande. Cependant, en cas d'expansion de la capacité d'interconnexion, «market coupling» est préférable. préférable. Dans tous les cas, la Finlande a intérêt à garder une réserve stratégique, car même si cette politique entraine des coûts, elle lui permet de profiter des avantages de l'intégration tout en limitant ca dépendance envers les importations. En général, nous concluons que si les politiques adéquates sont implémentées, l'intégration des marchés électriques peut amener des bénéfices. Cependant, une grande capacité d'interconnexion n'est désirable que si les pays ont une complémentarité importante et il existe une confiance mutuelle. Les résultats des politiques qui cherchent à préserver la sécurité d'approvisionnement au niveau national peuvent être très contre-intuitifs, étant données les interactions entre les pays voisins et leurs effets sur les investissements en génération et en interconnexion. Il est donc très important pour les régulateurs de comprendre ces interactions et de coordonner décisions à fin de pouvoir profiter de l'interconnexion sans mettre en danger la sécurité d'approvisionnement. Mais il faut être conscients que même quand l'intégration amène de bénéfices pour la région, certains participants au marché sont perdants et pourraient essayer de bloquer le processus d'intégration.