993 resultados para Efficiency Tests


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gradually smart grids and smart meters are closer to the home consumers. Several countries has developed studies focused in the impacts arising from the introduction of these technologies and one of the main advantages are related to energy efficiency, observed through the awareness of the population on behalf of a more efficient consumption. These benefits are felt directly by consumers through the savings on electricity bills and also by the concessionaires through the minimization of losses in transmission and distribution, system stability, smaller loading during peak hours, among others. In this article two projects that demonstrate the potential energy savings through smart meters and smart grids are presented. The first performed in Korea, focusing on the installation of smart meters and the impact of use of user interfaces. The second performed in Portugal, focusing on the control of loads in a residence with distributed generation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study is to standardize the technical variables for preparation and storage of Plasmodium falciparum and of antigen components extracted with the amphoteric detergent Zwittergent. P. falciparum obtained from in vitro culture was stored at different temperatures and for different periods of time. For each variable, antigen components of the parasite were extracted in the presence or absence of protease inhibitors and submitted or not to later dialysis. Products were stored for 15, 30 and 60 days at different temperatures and immunological activity of each extract was determined by SDS-PAGE and ELISA using positive or negative standard sera for the presence of IgG directed to blood stage antigens of P. falciparum. Antigen extracts obtained from parasites stored at -20oC up to 10 days or at -70oC for 2 months presented the best results, showing well-defined bands on SDS-PAGE and Western blots and presenting absorbance values in ELISA that permitted safe differentiation between positive and negative sera.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We compared the indirect immunofluorescence assay (IFA) with Western blot (Wb) as a confirmatory method to detect antibodies anti retrovirus (HIV-1 and HTLV-I/II). Positive and negative HIV-1 and HTLV-I/II serum samples from different risk populations were studied. Sensitivity, specificity, positive, negative predictive and kappa index values were assayed, to assess the IFA efficiency versus Wb. The following cell lines were used as a source of viral antigens: H9 ( HTLV-III b); MT-2 and MT-4 (persistently infected with HTLV-I) and MO-T (persistently infected with HTLV-II). Sensitivity and specificity rates for HIV-1 were 96.80% and 98.60% respectively, while predictive positive and negative values were 99.50% and 92.00% respectively. No differences were found in HIV IFA performance between the various populations studied. As for IFA HTLV system, the sensitivity and specificity values were 97.91% and 100% respectively with positive and negative predictive values of 100% and 97.92%. Moreover, the sensitivity of the IFA for HTLV-I/II proved to be higher when the samples were tested simultaneously against both antigens (HTLV-I-MT-2 and HTLV-II-MO-T). The overall IFA efficiency for HIV-1 and HTLV-I/II-MT-2 antibody detection probed to be very satisfactory with an excellent correlation with Wb (Kappa indexes 0.93 and 0.98 respectively). These results confirmed that the IFA is a sensitive and specific alternative method for the confirmatory diagnosis of HIV-1 and HTLV-I/II infection in populations at different levels of risk to acquire the infection and suggest that IFA could be included in the serologic diagnostic algorithm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Screening blood donations for anti-HCV antibodies and alanine aminotransferase (ALT) serum levels generally prevents the transmission of hepatitis C virus (HCV) by transfusion. The aim of the present study was to evaluate the efficiency of the enzyme immunoassay (EIA) screening policy in identifying potentially infectious blood donors capable to transmit hepatitis C through blood transfusion. We have used a reverse transcriptase (RT)-nested polymerase chain reaction (PCR) to investigate the presence of HCV-RNA in blood donors. The prevalence of HCV-RNA positive individuals was compared with the recombinant immunoblot assay (RIBA-2) results in order to assess the usefulness of both tests as confirmatory assays. Both tests results were also compared with the EIA-2 OD/C ratio (optical densities of the samples divided by the cut off value). ALT results were expressed as the ALT quotient (qALT), calculated dividing the ALT value of the samples by the maximum normal value (53UI/l) for the method. Donors (n=178) were divided into five groups according to their EIA anti-HCV status and qALT: group A (EIA > or = 3, ALT<1), group B (EIA > or = 3, ALT>1), group C (1<=EIA<3, ALT<1), group D (1<=EIA<3, ALT>1) and group E (EIA<=0.7). HCV sequences were detected by RT-nested PCR, using primers for the most conserved region of viral genome. RIBA-2 was applied to the same samples. In group A (n=6), all samples were positive by RT-nested PCR and RIBA-2. Among 124 samples in group B, 120 (96.8%) were RIBA-2 positive and 4 (3.2%) were RIBA-2 indeterminate but were seropositive for antigen c22.3. In group B, 109 (87.9%) of the RIBA-2 positive samples were also RT-nested PCR positive, as well as were all RIBA-2 indeterminate samples. In group C, all samples (n=9) were RT-nested PCR negative: 4 (44.4%) were also RIBA-2 negative, 4 (44.4%) were RIBA-2 positive and 1 (11.1%) was RIBA-2 indeterminate. HCV-RNA was detected by RT-nested PCR in 3 (37.5%) out of 8 samples in group D. Only one of them was also RIBA-2 positive, all the others were RIBA-2 indeterminate. All of the group E samples (controls) were RT- nested PCR and RIBA-2 negative. Our study suggests a strong relation between anti-HCV EIA-2 ratio > or = 3 and detectable HCV-RNA by RT-nested PCR. We have also noted that blood donors with RIBA-2 indeterminate presented a high degree of detectable HCV-RNA using RT-nested PCR (75%), especially when the c22.3 band was detected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A manutenção, durante vários anos, traduziu-se num conceito paliativo de instalações e equipamentos, o que se veio a revelar como uma atitude negligente perante o Homem e o Ambiente. As preocupações ambientais estão na ordem do dia e têm sido muitas as vozes que se têm levantado para que o consumo de energia seja mais equilibrado e para que as emissões de CO2 diminuam de forma a preservar o Planeta. De acordo com a resolução do Conselho Europeu, em 2007 (1), foi apresentado um pacote de propostas que visam a sustentabilidade e estimulam a Eficiência Energética (EE), com o objectivo de reduzir os consumos energéticos dos edifícios, quer estes sejam novos ou reabilitados. Segundo a Direcção Geral de Energia e Geologia os edifícios são responsáveis por 60% dos consumos de energia eléctrica, consumo esse que pode ser reduzido em mais de 50%, através de medidas de EE, traduzindo-se numa redução de 400 milhões de toneladas de CO2 por ano. (2) Para além de medidas de EE, também as práticas de manutenção preventiva podem contribuir para a diminuição dos consumos energéticos e de emissões de CO2. Segundo o Institute for Building Efficiency práticas de manutenção preventiva em equipamentos de Aquecimento Ventilação e Ar Condicionado (AVAC) reduzem os consumos energéticos de 10 a 20% e, em contrapartida, a negligência na execução da manutenção pode aumentar os consumos energéticos de 30 a 60%. (3) Uma outra análise de valores a ter em conta, é a Intensidade Energética (IE). Leia-se IE como sendo o valor global da energia consumida num país a dividir pelo seu produto interno bruto. A contribuição do sector dos serviços para a IE nacional era de 17% no ano de 2005. (4) Se a estes dados acrescentarmos que 70% dessa energia é consumida por equipamentos AVAC (5) e que práticas de manutenção reduzem esses valores entre 10 a 20%, pode concluir-se que a redução de custos energéticos associada à manutenção preventiva é efectiva e significativa. Apresentando um cenário ideal e hipotético, se ao contributo do sector dos serviços, para a IE nacional, se isolar o valor referente a equipamentos de AVAC, obtem-se uma IE de aproximadamente 12%. Se adicionalmente se considerar uma taxa de redução, relativa à execução da manutenção, entre 10 e 20%, Portugal obteria uma IE, relativamente aos consumos energéticos em edificios de serviços, não de 17% mas sim entre 14,6% e 15,8%. Neste trabalho pretende-se comprovar que um plano de actividades de manutenção equilibrado, monitorizado, e gerido de forma eficaz e funcional, é uma ferramenta fundamental no cumprimento de objectivos e metas europeias traçadas, que se reúnem num objectivo comum de preservação do planeta. A adopção deste tipo de medidas contribuirá para a racionalização dos consumos energéticos e para o aumento da vida útil dos equipamentos, bem como para a melhoria do desempenho económico e financeiro das organizações, tal como se poderá ler mais à frente neste trabalho. Será também analisado um caso prático, verificando a eficácia das medidas tomadas durante as intervenções preventivas de manutenção, sendo que para isso será estudado o comportamento de um equipamento, antes e após a realização de tarefas de manutenção preventiva. Tentar-se-á, junto de gestores de edifícios, recolher a opinião que têm sobre a importância da manutenção. Ao longo de toda a pesquisa foi possível consolidar a hipótese formulada inicialmente no que concerne ao contributo da manutenção para a sustentabilidade, quer através da revisão da literatura, quer nos testes efectuados a equipamentos. Foi possível confirmar que um plano de manutenção ajustado, monitorizado e cumprido é uma ferramenta na diminuição dos consumos energéticos, aumento da vida útil de equipamentos e por sua vez na diminuição de emissões de CO2. Verificou-se também que o controlo de poluentes e ventilação adequada dos edifícios são uma ferramenta essencial para a qualidade do ar interior, parâmetros facilmente controlados nas actividades de manutenção. O contributo das opiniões recolhidas entre os gestores de edifícios, para este estudo, foi também bastante importante, uma vez que todos eles reconhecem o papel importante da manutenção, mas nem todos estão sensibilizados para o seu papel na sustentabilidade do planeta. Nesta dissertação é deixado um alerta: o crescimento da população mundial e a consequente utilização de recursos naturais que são finitos, não sendo controlado de uma forma sustentada, pode resultar na destruição de um planeta único. O papel negativo do Homem nas alterações climáticas é inequívoco e é necessário melhorar a sua relação com o Ambiente. Cada ser humano está inserido na sua comunidade e dentro dela tem a sua função, cabe a cada um exercer esta responsabilidade nas suas actividades do dia-a-dia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Astringency is an organoleptic property of beverages and food products resulting mainly from the interaction of salivary proteins with dietary polyphenols. It is of great importance to consumers, but the only effective way of measuring it involves trained sensorial panellists, providing subjective and expensive responses. Concurrent chemical evaluations try to screen food astringency, by means of polyphenol and protein precipitation procedures, but these are far from the real human astringency sensation where not all polyphenol–protein interactions lead to the occurrence of precipitate. Here, a novel chemical approach that tries to mimic protein–polyphenol interactions in the mouth is presented to evaluate astringency. A protein, acting as a salivary protein, is attached to a solid support to which the polyphenol binds (just as happens when drinking wine), with subsequent colour alteration that is fully independent from the occurrence of precipitate. Employing this simple concept, Bovine Serum Albumin (BSA) was selected as the model salivary protein and used to cover the surface of silica beads. Tannic Acid (TA), employed as the model polyphenol, was allowed to interact with the BSA on the silica support and its adsorption to the protein was detected by reaction with Fe(III) and subsequent colour development. Quantitative data of TA in the samples were extracted by colorimetric or reflectance studies over the solid materials. The analysis was done by taking a regular picture with a digital camera, opening the image file in common software and extracting the colour coordinates from HSL (Hue, Saturation, Lightness) and RGB (Red, Green, Blue) colour model systems; linear ranges were observed from 10.6 to 106.0 μmol L−1. The latter was based on the Kubelka–Munk response, showing a linear gain with concentrations from 0.3 to 10.5 μmol L−1. In either of these two approaches, semi-quantitative estimation of TA was enabled by direct eye comparison. The correlation between the levels of adsorbed TA and the astringency of beverages was tested by using the assay to check the astringency of wines and comparing these to the response of sensorial panellists. Results of the two methods correlated well. The proposed sensor has significant potential as a robust tool for the quantitative/semi-quantitative evaluation of astringency in wine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Skin testing remains an essential diagnostic tool in modern allergy practice. A signifi cant variability has been reported regarding technical procedures, interpretation of results and documentation. This review has the aim of consolidating methodological recommendations through a critical analysis on past and recent data. This will allow a better understanding on skin prick test (SPT) history; technique; (contra-) indications; interpretation of results; diagnostic pitfalls; adverse reactions; and variability factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the implementation of the Bologna Process several challenges have been posed to higher education institution, particularly in Portugal. One of the main implications is related to the change of the paradigm of a teacher centered education, to a paradigm that is student centered. This change implies the change of the way to assess courses in higher education institutions. Continuous and formative assessments emerged as the focus, catalyzed by electronic assessment, or e-assessment. This paper presents a case of the implementation of an e-assessment strategy, implemented in order to allow continuous, formative assessment in numerous mathematics classes using multiple-choice questions tests implement in Moodle open-source learning management system. The implementation can be considered a success.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the implementation of the Bologna Process several challenges have been posed to higher education institution, particularly in Portugal. One of the main implications is related to the change of the paradigm of a teacher centered education, to a paradigm that is student centered. This change implies the change of the way to assess courses in higher education institutions. Continuous and formative assessments emerged as the focus, catalyzed by electronic assessment, or e-assessment. This paper presents a case of the implementation of an e-assessment strategy, implemented in order to allow continuous, formative assessment in numerous mathematics classes using multiple-choice questions tests implement in Moodle open-source learning management system. The implementation can be considered a success.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diagnosis of American cutaneous leishmaniasis (ACL) is frequently based on clinical and epidemiological data associated with the results of laboratory tests. Some laboratory methods are currently being applied for the diagnosis of ACL, among them the indirect immunofluorescence reaction (IIFR), the Montenegro skin test (MST), histopathological examination, and the polymerase chain reaction (PCR). The performance of these methods varies in a considerable proportion of patients. After the standardization of an immunoenzymatic test (ELISA) for the detection of IgG in the serum of patients with ACL using a crude Leishmania braziliensis antigen, the results obtained were compared to those of other tests routinely used for the diagnosis. The tests revealed the following sensitivity, when analyzed separately: 85% for ELISA IgG, 81% for PCR, 64.4% for MST, 58.1% for IIFR, and 34% for the presence of parasites in the biopsy. ELISA was positive in 75% of patients with ACL presenting a negative MST, in 84.8% of ACL patients with negative skin or mucous biopsies for the presence of the parasite, and in 100% of cases with a negative PCR. Thus, ELISA presented a higher sensitivity than the other tests and was useful as a complementary method for the diagnosis of ACL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: A growing body of evidence shows the prognostic value of oxygen uptake efficiency slope (OUES), a cardiopulmonary exercise test (CPET) parameter derived from the logarithmic relationship between O(2) consumption (VO(2)) and minute ventilation (VE) in patients with chronic heart failure (CHF). OBJECTIVE: To evaluate the prognostic value of a new CPET parameter - peak oxygen uptake efficiency (POUE) - and to compare it with OUES in patients with CHF. METHODS: We prospectively studied 206 consecutive patients with stable CHF due to dilated cardiomyopathy - 153 male, aged 53.3±13.0 years, 35.4% of ischemic etiology, left ventricular ejection fraction 27.7±8.0%, 81.1% in sinus rhythm, 97.1% receiving ACE-Is or ARBs, 78.2% beta-blockers and 60.2% spironolactone - who performed a first maximal symptom-limited treadmill CPET, using the modified Bruce protocol. In 33% of patients an cardioverter-defibrillator (ICD) or cardiac resynchronization therapy device (CRT-D) was implanted during follow-up. Peak VO(2), percentage of predicted peak VO(2), VE/VCO(2) slope, OUES and POUE were analyzed. OUES was calculated using the formula VO(2) (l/min) = OUES (log(10)VE) + b. POUE was calculated as pVO(2) (l/min) / log(10)peakVE (l/min). Correlation coefficients between the studied parameters were obtained. The prognosis of each variable adjusted for age was evaluated through Cox proportional hazard models and R2 percent (R2%) and V index (V6) were used as measures of the predictive accuracy of events of each of these variables. Receiver operating characteristic (ROC) curves from logistic regression models were used to determine the cut-offs for OUES and POUE. RESULTS: pVO(2): 20.5±5.9; percentage of predicted peak VO(2): 68.6±18.2; VE/VCO(2) slope: 30.6±8.3; OUES: 1.85±0.61; POUE: 0.88±0.27. During a mean follow-up of 33.1±14.8 months, 45 (21.8%) patients died, 10 (4.9%) underwent urgent heart transplantation and in three patients (1.5%) a left ventricular assist device was implanted. All variables proved to be independent predictors of this combined event; however, VE/VCO2 slope was most strongly associated with events (HR 11.14). In this population, POUE was associated with a higher risk of events than OUES (HR 9.61 vs. 7.01), and was also a better predictor of events (R2: 28.91 vs. 22.37). CONCLUSION: POUE was more strongly associated with death, urgent heart transplantation and implantation of a left ventricular assist device and proved to be a better predictor of events than OUES. These results suggest that this new parameter can increase the prognostic value of CPET in patients with CHF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Testing problems in diagnosing human T-lymphotropic virus (HTLV) infection, mostly HTLV-II, have been documented in HIV/AIDS patients. Since December 1998, the Immunology Department of Instituto Adolfo Lutz (IAL) offers HTLV-I/II serology to Public Health Units that attend HTLV high-risk individuals. Two thousand, three hundred and twelve serum samples: 1,393 from AIDS Reference Centers (Group I), and 919 from HTLV out-patient clinics (Group II) were sent to IAL for HTLV-I/II antibodies detection. The majority of them were screened by two enzyme immunoassays (EIAs), and confirmed by Western Blot (WB 2.4, Genelabs). Seven different EIA kits were employed during the period, and according to WB results, the best performance was obtained by EIAs that contain HTLV-I and HTLV-II viral lysates and rgp21 as antigens. Neither 1st and 2nd, nor 3rd generation EIA kits were 100% sensitive in detecting truly HTLV-I/II reactive samples. HTLV-I and HTLV-II prevalence rates of 3.3% and 2.5% were detected in Group I, and of 9.6% and 3.6% in Group II, respectively. High percentages of HTLV-seroindeterminate WB sera were detected in both Groups. The algorithm testing to be employed in HTLV high-risk population from São Paulo, Brazil, needs the use of two EIA kits of different formats and compounds as screening, and because of high seroindeterminate WB, may be another confirmatory assay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Few studies have been performed in children withs uspected betalactam allergy.We aimed to assess the role of the drug provocation test(DPT)with betalactams in a paediatric setting and to study the association between allergy to betalactam antibiotics and other allergic diseases. Methods:We included all the patients under 15 years old who were consecutively referred to the Immunoallergy Department, Dona Estefânia Hospital,Portugal(January 2002 to April 2008)for a compatible history of allergic reaction to betalactam. All were submitted to a DPT.Children were proposed to performs kintests(ST)to betalactam antibiotics followed by DPT. If they decline ST,a DPT with the culprit drug was performed. Results: We studied 161 children,60%were boys,with a median age of 5years old at the time of the DPT.Thirty-three patients(20.5%)had an immediate reaction and 33(20.5%)a non-immediate reaction. These verity of there porte dreactions was low in most cases. Skin tests to betalactams were performed in 47 children and were positive in 8.DPT was positive inonlyone(3.4%)of the patients skin tested and in 11(13.4%)of those not skin tested. These verity of the DPT reaction was low.Asthma and food allergy were associated with a positive DPT in the later group. Conclusions: DPT seems a safe procedure even in the absence of ST in non-severe cases. This could be a practical optionin infants and pre-school children,where ST are painful and difficult to perform.Additional caution should be taken in children with asthma and food allergy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main serological marker for the diagnosis of recent toxoplasmosis is the specific IgM antibody, along with IgG antibodies of low avidity. However, in some patients these antibodies may persist long after the acute/recent phase, contributing to misdiagnosis in suspected cases of toxoplasmosis. In the present study, the diagnostic efficiency of ELISA was evaluated, with the use of peptides derived from T. gondii ESA antigens, named SAG-1, GRA-1 and GRA-7. In the assay referred to, we studied each of these peptides individually, as well as in four different combinations, as Multiple Antigen Peptides (MAP), aiming to establish a reliable profile for the acute/recent toxoplasmosis with only one patient serum sample. The diagnostic performance of the assay using MAP1, with the combination of SAG-1, GRA-1 and GRA-7 peptides, demonstrated better discrimination of the acute/recent phase from non acute/recent phase of toxoplasmosis. Our results show that IgM antibodies to MAP1 may be useful as a serological marker, enhancing the diagnostic efficiency of the assay for acute/recent phase of toxoplasmosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Azores archipelago is a zone with a vast cultural heritage, presenting a building stock mainly constructed in traditional stone masonry. It is known that this type of construction exhibits poor behaviour under seismic excitations; however it is extensively used in seismic prone areas, such as this case. The 9th of July of 1998 earthquake was the last seismic event in the islands, leaving many traditional stone constructions severely damaged or totally destroyed. This scenario led to an effort by the local government of improving the seismic resistance of these constructions, with the application of several reinforcement techniques. This work aims to study some of the most used reinforcement schemes after the 1998 earthquake, and to assess their effectiveness in the mitigation of the construction’s seismic vulnerability. A brief evaluation of the cost versus benefit of these retrofitting techniques is also made, seeking to identify those that are most suitable for each building typology. Thus, it was sought to analyze the case of real structures with different geometrical and physical characteristics, by establishing a comparison between the seismic performance of reinforced and non-reinforced structures. The first section contains the analysis of a total of six reinforcement scenarios for each building chosen. Using the recorded 1998 earthquake accelerograms, a linear time-history analysis was performed for each reinforcement scenario. A comparison was then established between the maximum displacements, inter-storey drift and maximum stress obtained, in order to evaluate the global seismic response of each reinforced structure. In the second part of the work, the examination of the performance obtained in the previous section, in relation to the cost of implementing each reinforcement technique, allowed to draw conclusions concerning the viability of implementing each reinforcement method, based on the book value of the buildings in study.