809 resultados para Dual gratings parallel matched


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent theory of physiology of language suggests a dual stream dorsal/ventral organization of speech perception. Using intra-cerebral Event-related potentials (ERPs) during pre-surgical assessment of twelve drug-resistant epileptic patients, we aimed to single out electrophysiological patterns during both lexical-semantic and phonological monitoring tasks involving ventral and dorsal regions respectively. Phonological information processing predominantly occurred in the left supra-marginal gyrus (dorsal stream) and lexico-semantic information occurred in anterior/middle temporal and fusiform gyri (ventral stream). Similar latencies were identified in response to phonological and lexico-semantic tasks, suggesting parallel processing. Typical ERP components were strongly left lateralized since no evoked responses were recorded in homologous right structures. Finally, ERP patterns suggested the inferior frontal gyrus as the likely final common pathway of both dorsal and ventral streams. These results brought out detailed evidence of the spatial-temporal information processing in the dual pathways involved in speech perception.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Post-transplant lymphoproliferative disease (PTLD) is a life-threatening complication of immunosuppression following transplantation. Epstein-Barr virus (EBV) and gammopathy in serum are associated with PTLD, but these two parameters have not been evaluated in parallel for their association with PTLD. METHODS: We evaluated the incidence of EBV load positivity, gammopathy, and protein expression in sera from all PTLD patients diagnosed at our hospital during the past seven yr. Results were compared with those of a control group including matched transplanted patients who did not develop PTLD. RESULTS: Seven of 10 PTLD patients presented EBV(+) PTLD, for which five patients had detectable serum EBV DNA levels compared with none of 38 controls (RR between two groups =121, p < 0.0001). Five out of 10 patients had gammopathy at PTLD diagnosis compared with 5/38 controls (RR between two groups = 6.6, p = 0.022). Additionally, protein serum analysis by high-resolution two-dimensional gel electrophoresis and image examination failed to evidence specific abnormality in patients with PTLD compared with controls. CONCLUSIONS: Our results confirm an association between EBV in sera and gammopathy with PTLD, and highlight the high specificity of the former analysis. Whether a combination of both analyses will improve the clinical detection of PTLD remains to be evaluated in a larger prospective cohort study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method of making a multiple matched filter which allows the recognition of different characters in successive planes in simple conditions is proposed. The generation of the filter is based on recording on the same plate the Fourier transforms of the different patterns to be recognized, each of which is affected by different spherical phase factors because the patterns have been placed at different distances from the lens. This is proved by means of experiments with a triple filter which allows satisfactory recognition of three characters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peripheral assessment of bone density using photon absorptiometry techniques has been available for over 40 yr. The initial use of radio-isotopes as the photon source has been replaced by the use of X-ray technology. A wide variety of models of single- or dual-energy X-ray measurement tools have been made available for purchase, although not all are still commercially available. The Official Positions of the International Society for Clinical Densitometry (ISCD) have been developed following a systematic review of the literature by an ISCD task force and a subsequent Position Development Conference. These cover the technological diversity among peripheral dual-energy X-ray absorptiometry (pDXA) devices; define whether pDXA can be used for fracture risk assessment and/or to diagnose osteoporosis; examine whether pDXA can be used to initiate treatment and/or monitor treatment; provide recommendations for pDXA reporting; and review quality assurance and quality control necessary for effective use of pDXA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the sensitivity limits of a broadband gravitational-wave detector based on dual resonators such as nested spheres. We determine both the thermal and back-action noises when the resonators displacements are read out with an optomechanical sensor. We analyze the contributions of all mechanical modes, using a new method to deal with the force-displacement transfer functions in the intermediate frequency domain between the two gravitational-wave sensitive modes associated with each resonator. This method gives an accurate estimate of the mechanical response, together with an evaluation of the estimate error. We show that very high sensitivities can be reached on a wide frequency band for realistic parameters in the case of a dual-sphere detector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the concept of a sensitive and broadband resonant mass gravitational wave detector. A massive sphere is suspended inside a second hollow one. Short, high-finesse Fabry-Perot optical cavities read out the differential displacements of the two spheres as their quadrupole modes are excited. At cryogenic temperatures, one approaches the standard quantum limit for broadband operation with reasonable choices for the cavity finesses and the intracavity light power. A molybdenum detector, of overall size of 2 m, would reach spectral strain sensitivities of 2x10-23Hz-1/2 between 1000 and 3000 Hz.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Iowa Division of Criminal and Juvenile Justice Planning recently released a report summarizing its evaluation of the Dual Diagnosis Offender Program (DDOP) administered by the First Judicial District Department of Correctional Services.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Growth is a central process in paediatrics. Weight and height evaluation are therefore routine exams for every child but in some situation, particularly inflammatory bowel disease (IBD), a wider evaluation of nutritional status needs to be performed. Objectives: To assess the accuracy of bio-impedance analysis (BIA) compared to the gold standard dual energy X-ray absorptiometry (DEXA) in estimating percentage body fat (fat mass; FM) and lean body mass (fat free mass; FFM) in children with inflammatory bowel disease (IBD). To compare FM and FFM levels between patients with IBD and healthy controls. Methods: Twenty-nine healthy controls (12 females; mean age: 12.7 ± 1.9 years) and 21 patients (11 females; 14.3 ± 1.3 years) were recruited from August 2011 to October 2012 at our institution. BIA was performed in all children and DEXA in patients only. Concordance between BIA and DEXA was assessed using Lin's concordance correlation and the Bland-Altman method. Between-group comparisons were made using analysis of variance adjusting for age. Results: BIA-derived FM% showed a good concordance with DEXA-derived values, while BIA-derived FFM% tended to be slightly higher than DEXA-derived values (table). No differences were found between patients and controls regarding body mass index (mean ± SD: 19.3 ± 3.3 vs. 20.1 ± 2.8 kg/m2, respectively; age-adjusted P = 0.08) and FM% (boys: 25.3 ± 10.2 vs. 22.6 ± 7.1%, for patients and controls, respectively; P = 0.20; girls: 28.2 ± 5.7 vs. 26.4 ± 7.7%; P = 0.91). Also, no differences were found regarding FFM% in boys (74.9 ± 10.2 vs. 77.4 ± 7.1%; P = 0.22) and girls (71.8 ± 5.6 vs. 73.5 ± 7.7%; P = 0.85). Conclusion: BIA adequately assesses body composition (FM%) in children with IBD and could advantageously replace DEXA, which is more expensive and less available. No differences in body composition were found between children with IBD and healthy controls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Phosphopeptides tagging reactions by dinuclear zinc(II) complexes (1,3-bis[bis(2-pyridylmethyl)amino]-propan-2-olato dizinc(II)3+, called tag) were performed with a dual-channel microsprayer in electrospray ionization mass spectrometry. The reaction is first studied ex situ and analyzed with a commercial electrospray source. In situ reactions (i.e., inside the Taylor cone) were achieved with a dual-channel microsprayer both with the tag synthesized chemically before the experiments and with the tag electrogenerated by in situ oxidation of a zinc electrode, also used to apply the electrospray current. The device consists of a polyimide microchip with two microchannels (20 microm x 50 microm x 1 cm) etched on each side of the structure and connecting only at the tip of the microchip. We demonstrate here that mixing two solutions with different physicochemical properties inside the Taylor cone can be used to selectively tag target molecules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: Donor cytomegalovirus seropositivity was reported to improve leukemia outcomes in HLA-A2 identical hematopoietic cell transplant (HCT) recipients, due to a possible cross-reactivity of donor HLA-A2-restricted CMV-specific T cells with minor histocompatibility (H) antigen of recipient cells. This study analyzed the role of donor CMV serostatus and HLA-A2 status on leukemia outcomes in a large population of HLA-identical HCT recipients. DESIGN AND METHODS: Leukemia patients transplanted between 1992 and 2003 at the Fred Hutchinson Cancer Research Center were categorized as standard risk [leukemia first remission, chronic myeloid leukemia in chronic phase (CML-CP)] and high risk (advanced disease) patients. Time-to-event analysis was used to evaluate the risk of relapse and death associated with HLA-A2 status and donor CMV serostatus. RESULTS: In standard risk patients, acute leukemia (p<0.001) and sex mismatch (female to male, p=0.004)) independently increased the risk of death, while acute leukemia increased the risk of relapse (p<0.001). In high risk patients acute leukemia (p=0.01), recipient age > or = 40 (p=0.005) and herpes simplex virus (HSV) seropositivity (p<0.001) significantly increased the risk death; HSV seropositivity (p=0.006) increased the risk of relapse. Donor CMV serostatus had no significant effect on mortality or relapse in any HLA group. INTERPRETATION AND CONCLUSION: This epidemiological study did not confirm the previously reported effect of donor CMV serostatus on the outcomes of leukemia in HLA-A2-identical HCT recipients. Addressing the question of cross-reactivity of HLA-A2-restricted CMV-specific T cells with minor H antigens in a clinical study would require knowledge of the patient's minor H antigen genotype. However, because of the unbalanced distribution of HLA-A2-restricted minor H antigens in the population and their incomplete identification, this question might be more appropriately evaluated in in vitro experiments than in a clinical study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[cat] En aquest treball extenem les reformes lineals introduïdes per Pfähler (1984) al cas d’impostos duals. Estudiem l’efecte relatiu que els retalls lineals duals d’un impost dual tenen sobre la distribució de la desigualtat -es pot fer un estudi simètric per al cas d’augments d’impostos-. Tambe introduïm mesures del grau de progressivitat d’impostos duals i mostrem que estan connectades amb el criteri de dominació de Lorenz. Addicionalment, estudiem l’elasticitat de la càrrega fiscal de cadascuna de les reformes proposades. Finalment, gràcies a un model de microsimulació i una gran base de dades que conté informació sobre l’IRPF espanyol de l’any 2004, 1) comparem l’efecte que diferents reformes tindrien sobre l’impost dual espanyol i 2) estudiem quina redistribució de la riquesa va suposar la reforma dual de l’IRPF (Llei ’35/2006’) respecte l’anterior impost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To determine the clinical and electrophysiological characteristics of patients with paroxysmal palpitations and neck pounding during sinus rhythm. Methods Clinical, electrocardiographic, and electrophysiological characteristics of six patients with paroxysmal palpitations and neck pounding during sinus rhythm were studied in basal conditions and when symptomatic. Response to treatment was observed. Results Baseline ECGs were normal (four patients) or had first degree atrioventricular block with intermittent PR shortening. During symptoms, narrow QRS rhythms were seen without visible P waves (three patients) or with P waves partially hidden in the QRS complex (three patients). Dual atrioventricular nodal pathways were found in all five patients who had electrophysiological studies. In these patients the slow pathway conduction time was long enough (mean (SD), 425 (121)¿ms) for ventricular activation after slow pathway conduction during sinus rhythm to coincide with the next atrial depolarisation, causing neck pounding during exercise (four patients) or at rest (two patients). Tachycardia was not induced in any patient. Medical treatment aggravated symptoms in three patients. A pacemaker was successfully used in two. Conclusions Neck pounding during sinus rhythm is a clinical manifestation of dual atrioventricular nodal pathways. Medical treatment may aggravate symptoms but a pacemaker may offer definitive relief.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: To test the hypothesis that postural stability would be more affected during acute exposure in hypobaric (HH) than in normobaric (NH) hypoxia.¦METHODS: In separate trials, 12 subjects stood on a posturographic platform for two successive 25.6 sec tests in three conditions: eyes open (EO), eyes closed (EC), and verbal dual task (DT). Ambient pressure in O(2) was matched between HH and NH at 1700 and 3000 m, respectively.¦RESULTS: Compared to NH, the length of Centre of Pression trajectory in Y-axis was increased (p<0.05) in HH for EO at 1700 m, EC at 1700 and 3000 m, and for DT at 1700 m, whereas the variance of speed of CoP was decreased (p<0.05) in EO, EC, and DT at 1700 m. Compared to normobaric normoxia (NN; 400 m), the surface of CoP trajectory was increased (p<0.05) in HH in EO and EC at 3000 m.¦CONCLUSIONS: HH deteriorated postural stability in the antero-posterior plane, for the variance of speed and the surface of CoP in 3 conditions, whereas no difference was observed between NH and NN. These results suggest that hypobaria instead of hypoxia per se plays an important role to the altered balance classically reported in altitude.