957 resultados para Diagnostic Method For Fluid Dynamics Experiment
Resumo:
Dissertação para obtenção do Grau de Doutor em Engenharia Química, especialidade de Engenharia Bioquímica
Resumo:
SUMMARYThis study evaluated the applicability of kDNA-PCR as a prospective routine diagnosis method for American tegumentary leishmaniasis (ATL) in patients from the Instituto de Infectologia Emílio Ribas (IIER), a reference center for infectious diseases in São Paulo - SP, Brazil. The kDNA-PCR method detected Leishmania DNA in 87.5% (112/128) of the clinically suspected ATL patients, while the traditional methods demonstrated the following percentages of positivity: 62.8% (49/78) for the Montenegro skin test, 61.8% (47/76) for direct investigation, and 19.3% (22/114) for in vitro culture. The molecular method was able to confirm the disease in samples considered negative or inconclusive by traditional laboratory methods, contributing to the final clinical diagnosis and therapy of ATL in this hospital. Thus, we strongly recommend the inclusion of kDNA-PCR amplification as an alternative diagnostic method for ATL, suggesting a new algorithm routine to be followed to help the diagnosis and treatment of ATL in IIER.
Resumo:
In the latest years the wind energy sector experienced an exponential growth all over the world. What started as a deployment of onshore projects, soon moved to offshore and, more recently to the urban environment within the context of smart cities and renewable micro-generation. However, urban wind projects using micro turbines do not have enough profit margins to enable the setup of comprehensive and expensive measurement campaigns, a standard procedure for the deployment of large wind parks. To respond to the wind assessment needs of the future smart cities a new and simple methodology for urban wind resource assessment was developed. This methodology is based on the construction of a surface involving a built area in order to estimate the wind potential by treating it as very complex orography. This is a straightforward methodology that allows estimating the sustainable urban wind potential, being suitable to map the urban wind resource in large areas. The methodology was applied to a case study and the results enabled the wind potential assessment of a large urban area being consistent with experimental data obtained in the case study area, with maximum deviations of the order of 10% (mean wind speed) and 20% (power density).
Resumo:
A potentially renewable and sustainable source of energy is the chemical energy associated with solvation of salts. Mixing of two aqueous streams with different saline concentrations is spontaneous and releases energy. The global theoretically obtainable power from salinity gradient energy due to World’s rivers discharge into the oceans has been estimated to be within the range of 1.4-2.6 TW. Reverse electrodialysis (RED) is one of the emerging, membrane-based, technologies for harvesting the salinity gradient energy. A common RED stack is composed by alternately-arranged cation- and anion-exchange membranes, stacked between two electrodes. The compartments between the membranes are alternately fed with concentrated (e.g., sea water) and dilute (e.g., river water) saline solutions. Migration of the respective counter-ions through the membranes leads to ionic current between the electrodes, where an appropriate redox pair converts the chemical salinity gradient energy into electrical energy. Given the importance of the need for new sources of energy for power generation, the present study aims at better understanding and solving current challenges, associated with the RED stack design, fluid dynamics, ionic mass transfer and long-term RED stack performance with natural saline solutions as feedwaters. Chronopotentiometry was used to determinate diffusion boundary layer (DBL) thickness from diffusion relaxation data and the flow entrance effects on mass transfer were found to avail a power generation increase in RED stacks. Increasing the linear flow velocity also leads to a decrease of DBL thickness but on the cost of a higher pressure drop. Pressure drop inside RED stacks was successfully simulated by the developed mathematical model, in which contribution of several pressure drops, that until now have not been considered, was included. The effect of each pressure drop on the RED stack performance was identified and rationalized and guidelines for planning and/or optimization of RED stacks were derived. The design of new profiled membranes, with a chevron corrugation structure, was proposed using computational fluid dynamics (CFD) modeling. The performance of the suggested corrugation geometry was compared with the already existing ones, as well as with the use of conductive and non-conductive spacers. According to the estimations, use of chevron structures grants the highest net power density values, at the best compromise between the mass transfer coefficient and the pressure drop values. Finally, long-term experiments with natural waters were performed, during which fouling was experienced. For the first time, 2D fluorescence spectroscopy was used to monitor RED stack performance, with a dedicated focus on following fouling on ion-exchange membrane surfaces. To extract relevant information from fluorescence spectra, parallel factor analysis (PARAFAC) was performed. Moreover, the information obtained was then used to predict net power density, stack electric resistance and pressure drop by multivariate statistical models based on projection to latent structures (PLS) modeling. The use in such models of 2D fluorescence data, containing hidden, but extractable by PARAFAC, information about fouling on membrane surfaces, considerably improved the models fitting to the experimental data.
Resumo:
Introduction Polymerase chain reaction (PCR) may offer an alternative diagnostic option when clinical signs and symptoms suggest visceral leishmaniasis (VL) but microscopic scanning and serological tests provide negative results. PCR using urine is sensitive enough to diagnose human visceral leishmaniasis (VL). However, DNA quality is a crucial factor for successful amplification. Methods A comparative performance evaluation of DNA extraction methods from the urine of patients with VL using two commercially available extraction kits and two phenol-chloroform protocols was conducted to determine which method produces the highest quality DNA suitable for PCR amplification, as well as the most sensitive, fast and inexpensive method. All commercially available kits were able to shorten the duration of DNA extraction. Results With regard to detection limits, both phenol: chloroform extraction and the QIAamp DNA Mini Kit provided good results (0.1 pg of DNA) for the extraction of DNA from a parasite smaller than Leishmania (Leishmania) infantum (< 100fg of DNA). However, among 11 urine samples from subjects with VL, better performance was achieved with the phenol:chloroform method (8/11) relative to the QIAamp DNA Mini Kit (4/11), with a greater number of positive samples detected at a lower cost using PCR. Conclusion Our results demonstrate that phenol:chloroform with an ethanol precipitation prior to extraction is the most efficient method in terms of yield and cost, using urine as a non-invasive source of DNA and providing an alternative diagnostic method at a low cost.
Resumo:
INTRODUCTION : The tuberculin test is a diagnostic method for detecting latent tuberculosis (TB) infection, especially among disease contact cases. The objective of this study was to analyze the prevalence and evolution of Mycobacterium tuberculosis infection among TB contact cases. METHODS : A retrospective cohort study was performed in a reference center for TB. The study population consisted of 2,425 patients who underwent a tuberculin test from 2003 to 2010 and whose results indicated contact with individuals with TB. The data were collected from the registry book of the tuberculin tests, patient files and the Information System Records of Notification Grievance. To verify the evolution of TB, case records through September 2014 were consulted. Data were analyzed using the Statistical Package for the Social Sciences (SPSS). In all hypothesis tests, a significance level of 0.05 was used. RESULTS : From the studied sample, 435 (17.9%) contacts did not return for reading. Among the 1,990 contacts that completed the test, the prevalence of latent TB infection was 35.4%. Of these positive cases, 50.6% were referred to treatment; the dropout rate was 42.5%. Among all of the contacts, the TB prevalence was 1.8%, from which 13.2% abandoned treatment. CONCLUSIONS : The collected data indicate the need for more effective public policies to improve TB control, including administering tests that do not require a return visit for reading, enhancing contact tracing and encouraging actions that reinforce full treatment adherence.
Resumo:
Tese de Doutoramento - Leaders for Technical Industries (LTI) - MIT Portugal
Resumo:
Using different bacteriological (urease test, Gram staining and culture) and histological (Steiner staining and modified Giemsa staining) techniques, we searched for the presence of Helicobacter pylori in the gastric antrum of 200 dyspeptic Brazilian patients (106 females and 94 males aged 19 days to 81 years). The presence of bacteria was then correlated with the endoscopic and histological findings. H. pylori was present in 59.5 of the population studied. In Brazil, colonization occurs early, involving 37 of the dyspeptic population by 20 years of age. The presence of H. pylori in the gastric antrum was strongly associated with duodenal ulcer (P < 0.001) and a normal endoscopic examination did not exclude the possibility of colonization of the gastric antrum by H. pylori. The most sensitive test was the preformed urease test (89). We conclude that more than one diagnostic method should preferably be used for the detection of H. pylori and that the presence of H. pylori is closely correlated with active chronic gastritis (P < 0.001).
Resumo:
The ideal diagnostic method for schistosomiasis detection seems to be still far from available. Paucity of egg output in low prevalence situations, low levels of circulating antigens in individuals with low intensity of infection and inadequate specificity of antibody detection systems outline pieces of a puzzle that challenges scientific efforts. Estimated prevalence, financial resources and operational reality must be taken into account when deciding the diagnostic method to be used. A combination of a screening step, using a fast strip test for antibody detection with a parasitological ratification step such as Kato-Katz repeated stool examination may serve as a diagnostic approach for a previously untreated low level endemic area. However, when eradication is the aim, and high financial investment is available, re-treatment may be based on the association between multiple stool examination and circulating antigen detection. Ethical aspects as well as cost-benefit rates between treatment and diagnosis approaches lead to the conclusion that in spite of the recent advances in simple administered and relatively safe drugs, treatment should only be performed when supported by appropriated diagnosis
Resumo:
Recent technological advances in remote sensing have enabled investigation of the morphodynamics and hydrodynamics of large rivers. However, measuring topography and flow in these very large rivers is time consuming and thus often constrains the spatial resolution and reach-length scales that can be monitored. Similar constraints exist for computational fluid dynamics (CFD) studies of large rivers, requiring maximization of mesh-or grid-cell dimensions and implying a reduction in the representation of bedform-roughness elements that are of the order of a model grid cell or less, even if they are represented in available topographic data. These ``subgrid'' elements must be parameterized, and this paper applies and considers the impact of roughness-length treatments that include the effect of bed roughness due to ``unmeasured'' topography. CFD predictions were found to be sensitive to the roughness-length specification. Model optimization was based on acoustic Doppler current profiler measurements and estimates of the water surface slope for a variety of roughness lengths. This proved difficult as the metrics used to assess optimal model performance diverged due to the effects of large bedforms that are not well parameterized in roughness-length treatments. However, the general spatial flow patterns are effectively predicted by the model. Changes in roughness length were shown to have a major impact upon flow routing at the channel scale. The results also indicate an absence of secondary flow circulation cells in the reached studied, and suggest simpler two-dimensional models may have great utility in the investigation of flow within large rivers. Citation: Sandbach, S. D. et al. (2012), Application of a roughness-length representation to parameterize energy loss in 3-D numerical simulations of large rivers, Water Resour. Res., 48, W12501, doi: 10.1029/2011WR011284.
Resumo:
Projecte de recerca elaborat a partir d’una estada a la University of Groningen, Holanda, entre 2007 i 2009. La simulació directa de la turbulència (DNS) és una eina clau dins de la mecànica de fluids computacional. Per una banda permet conèixer millor la física de la turbulència i per l'altra els resultats obtinguts són claus per el desenvolupament dels models de turbulència. No obstant, el DNS no és una tècnica vàlida per a la gran majoria d'aplicacions industrials degut al elevats costos computacionals. Per tant, és necessari cert grau de modelització de la turbulència. En aquest context, s'han introduïts importants millores basades en la modelització del terme convectiu (no lineal) emprant symmetry-preserving regularizations. En tracta de modificar adequadament el terme convectiu a fi de reduir la producció d'escales més i més petites (vortex-stretching) tot mantenint tots els invariants de les equacions originals. Fins ara, aquest models s'han emprat amb èxit per nombres de Rayleigh (Ra) relativament elevats. En aquest punt, disposar de resultats DNS per a configuracions més complexes i nombres de Ra més elevats és clau. En aquest contexte, s'han dut a terme simulacions DNS en el supercomputador MareNostrum d'una Differentially Heated Cavity amb Ra=1e11 i Pr=0.71 durant el primer any dels dos que consta el projecte. A més a més, s'ha adaptat el codi a fi de poder simular el fluxe al voltant d'un cub sobre una pared amb Re=10000. Aquestes simulacions DNS són les més grans fetes fins ara per aquestes configuracions i la seva correcta modelització és un gran repte degut la complexitat dels fluxes. Aquestes noves simulacions DNS estan aportant nous coneixements a la física de la turbulència i aportant resultats indispensables per al progrés de les modelitzacións tipus symmetry-preserving regularization.
Resumo:
In México, the role of mammals in the transmission cycle of Trypanosoma cruzi is poorly known. In the State of Yucatán, an endemic area of Chagas disease, both Didelphis virginiana and D. marsupialis occur sympatrically. However, until now, only the former species had been found infected with T. cruzi. To evaluate the role of D. virginiana in a peridomestic transmission, nine periods of capture-recapture were performed around the village of Dzidzilché, Yucatán. The sex, age, reproductive status, location, and presence of infection with T. cruzi were recorded for each opossum. The chromosome morphology was used to identify the opossum species. T. cruzi was identified by the presence of pseudocysts of amastigotes in cardiac muscle fibers of Balb/c mice inoculated with strains isolated from opossums. However, xenodiagnosis was the best diagnostic method. Triatoma dimidiata, the vector, were collected in and around the opossums' nests, and human dwellings; and were checked for T. cruzi. From 102 blood samples of D. virginiana examined 55 (53.9%) were positive to T. cruzi, the only two D. marsupialis captured were negative. Significant differences were found between infection, and both sex and reproductive condition. Eight out of 14 triatomines collected in peridomestic nests (57.1%), and 32 of 197 captured inside houses (16.3%) were found infected, suggesting a peridomestic transmission. The statistically high abundance of infected opossums and triatomines during the dry season (March to May) suggested the existence of a seasonality in the peridomestic transmission of T. cruzi in Dzidzilché.
Resumo:
The socalled enteropathogenic Escherichia coli (EPEC) O serogroups include typical and atypical EPEC, enterohaemorrragic E. coli, enterotoxigenic E. coli, and enteroaggregative E. coli. The aim of this article is to review the composition of each O serogroup and the major serotypes, clones, and additional virulence characteristics of each of these diarrheageniccategories. Their adherence patterns and genetic relationships are also presented. The review is based on the study of 805 strains of serogroups O26, O55, O86, O111, O114, O119, O125, O126, O1127, O128, and O142 most of which isolated in São Paulo from children with diarrhea between 1970 and 1990. Since some O serogroups include more than one diarrheageniccategory O serogrouping only should be abandoned as a diagnostic method. However serotyping is a reliable method for those serotypes that correspond to clones.
Resumo:
La dinàmica de fluids computacional (CFD) és una eina que serveix per analitzar mitjançantcomputadors diferents problemes que involucren fluxos de fluids. Els programes de CFD usen expressions matemàtiques no lineals que defineixen les equacions fonamentals de fluxos i transport de calor en fluids. Aquestes es resolen amb complexos algoritmes iteratius. Actualment aquesta eina és una part fonamental en els procés de disseny en moltes empreses relacionades amb la dinàmica de fluids. Les simulacions que es realitzen ambaquests programes s’ha demostrat que són fiables i que estalvien temps i diners, ja que eviten haver de realitzar els costosos processos d’assaig-error. En el projecte s’utilitza el programa de CFD Ansys CFX 11.0 per simular una agitació bifàsica composta per aigua i aire a temperatura ambient. Els objectius són determinar els paràmetres òptims de simulació que permetin recrear aquesta agitació, per posteriorment dissenyar un nou impulsor
Resumo:
El projecte pretén estudiar i quantificar les restriccions creades al fluid en circular pelsconductes d’admissió i escapament de la culata del motor del vehicle Àliga. L’estudi consta de quatre etapes: estudi de les restriccions actuals dels sistemes d’admissió i escapament; anàlisi dels resultats de la culata de sèrie i proposta de millores aplicables al model real; càlcul de les restriccions creades pels models millorats, i finalment, estudi comparatiu dels resultats obtinguts, interpretant els resultats dels principals paràmetres a analitzar