Intravenous immunoglobulin (IVIg) is widely used to treat autoimmune diseases. Several mutually nonexclusive mechanisms are proposed to explain the beneficial effects of IVIg in patients (1, 2). Lately, Ravetch and colleagues (3) demonstrate that anti-inflammatory activity of IVIg is mediated mainly by antibodies that contain terminal _2,6-sialic acid linkages at the Asn297-linked glycan of Fc region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the programming an FPGA (Field Programmable Gate Array) to emulate the dynamics of DC machines. FPGA allows high speed real time simulation with high precision. The described design includes block diagram representation of DC machine, which contain all arithmetic and logical operations. The real time simulation of the machine in FPGA is controlled by user interfaces they are Keypad interface, LCD display on-line and digital to analog converter. This approach provides emulation of electrical machine by changing the parameters. Separately Exited DC machine implemented and experimental results are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method of ion extraction from plasmas is reported in which the interference of field lines due to the extraction system in the plasma region is avoided by proper shaping of the extractor electrode and is supported by field plots.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The bentiromide test was evaluated using plasma p-aminobenzoic acid as an indirect test of pancreatic insufficiency in young children between 2 months and 4 years of age. To determine the optimal test method, the following were examined: (a) the best dose of bentiromide (15 mg/kg or 30 mg/kg); (b) the optimal sampling time for plasma p-aminobenzoic acid, and; (c) the effect of coadministration of a liquid meal. Sixty-nine children (1.6 ± 1.0 years) were studied, including 34 controls with normal fat absorption and 35 patients (34 with cystic fibrosis) with fat maldigestion due to pancreatic insufficiency. Control and pancreatic insufficient subjects were studied in three age-matched groups: (a) low-dose bentiromide (15 mg/kg) with clear fluids; (b) high-dose bentiromide (30 mg/kg) with clear fluids, and; (c) high-dose bentiromide with a liquid meal. Plasma p-aminobenzoic acid was determined at 0, 30, 60, and 90 minutes then hourly for 6 hours. The dose effect of bentiromide with clear liquids was evaluated. High-dose bentiromide best discriminated control and pancreatic insufficient subjects, due to a higher peak plasma p-aminobenzoic acid level in controls, but poor sensitivity and specificity remained. High-dose bentiromide with a liquid meal produced a delayed increase in plasma p-aminobenzoic acid in the control subjects probably caused by retarded gastric emptying. However, in the pancreatic insufficient subjects, use of a liquid meal resulted in significantly lower plasma p-aminobenzoic acid levels at all time points; plasma p-aminobenzoic acid at 2 and 3 hours completely discriminated between control and pancreatic insufficient patients. Evaluation of the data by area under the time-concentration curve failed to improve test results. In conclusion, the bentiromide test is a simple, clinically useful means of detecting pancreatic insufficiency in young children, but a higher dose administered with a liquid meal is recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thyristor forced commutated AC/DC convertors are useful for improving the power factor and waveform of AC-side line current. These are controlled through pulse-width modulation schemes for best performance. However, the 3-phase versions impose restrictions on the PWM strategies that can be implemented for excellent harmonic rejection. This paper presents new PWM control strategies for the 3-phase converters and compares them along with the conventional 4-pulse PWM strategy for harmonic elimination. Finally, two new PWM strategies are shown to be the best, for which oscillograms are presented from actual implementation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electric field in certain electrostatic devices can be modeled by a grounded plate electrode affected by a corona discharge generated by a series of parallel wires connected to a DC high-voltage supply. The system of differential equations that describe the behaviour (i.e., charging and motion) of the conductive particle in such an electric field has been numerically solved, using several simplifying assumptions. Thus, it was possible to investigate the effect of various electrical and mechanical factors on the trajectories of conductive particles. This model has been employed to study the behaviour of coalparticles in fly-ash corona separators.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A recently developed radioimmunoassay (RIA) for measuring insulin-like growth factor (IGF-I) in a variety of fish species was used to investigate the correlation between growth rate and circulating IGF-I concentrations of barramundi (Lates calcarifer), Atlantic salmon (Salmo salar) and Southern Bluefin tuna (Thunnus maccoyii). Plasma IGF-I concentration significantly increased with increasing ration size in barramundi and IGF-I concentration was positively correlated to growth rates obtained in Atlantic salmon (r2=0.67) and barramundi (r2=0.65) when fed a variety of diet formulations. IGF-I was also positively correlated to protein concentration (r2=0.59). This evidence suggested that measuring IGF-I concentration may provide a useful tool for monitoring fish growth rate and also as a method to rapidly assess different aquaculture diets. However, no such correlation was demonstrated in the tuna study probably due to seasonal cooling of sea surface temperature shortly before blood was sampled. Thus, some recommendations for the design and sampling strategy of nutritional trials where IGF-I concentrations are measured are discussed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Correlations between liveweight gains and temperament during feedlotting (Voisinet et al., 1997) may be an indication that cattle of different temperament suffer different degrees of stress. This paper describes the effect of grouping into feedlot pens, cattle of good, poor and mixed (some good and some poor) temperament on blood parameters that are indicators of stress (Bennett et al., 1989). Animal production for a consuming world : proceedings of 9th Congress of the Asian-Australasian Association of Animal Production Societies [AAAP] and 23rd Biennial Conference of the Australian Society of Animal Production [ASAP] and 17th Annual Symposium of the University of Sydney, Dairy Research Foundation, [DRF]. 2-7 July 2000, Sydney, Australia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-thermal plasma (NTP) has been introduced over the last few years as a promising after- treatment system for nitrogen oxides and particulate matter removal from diesel exhaust. NTP technology has not been commercialised as yet, due to its high rate of energy consumption. Therefore, it is important to seek out new methods to improve NTP performance. Residence time is a crucial parameter in engine exhaust emissions treatment. In this paper, different electrode shapes are analysed and the corresponding residence time and NOx removal efficiency are studied. An axisymmetric laminar model is used for obtaining residence time distribution numerically using FLUENT software. If the mean residence time in a NTP plasma reactor increases, there will be a corresponding increase in the reaction time and consequently the pollutant removal efficiency increases. Three different screw thread electrodes and a rod electrode are examined. The results show the advantage of screw thread electrodes in comparison with the rod electrode. Furthermore, between the screw thread electrodes, the electrode with the thread width of 1 mm has the highest NOx removal due to higher residence time and a greater number of micro-discharges. The results show that the residence time of the screw thread electrode with a thread width of 1 mm is 21% more than for the rod electrode.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Common mode voltage (CMV) variations in PWM inverter-fed drives generate unwanted shaft and bearing current resulting in early motor failure. Multilevel inverters reduce this problem to some extent, with higher number of levels. But the complexity of the power circuit increases with an increase in the number of inverter voltage levels. In this paper a five-level inverter structure is proposed for open-end winding induction motor (IM) drives, by cascading only two conventional two-level and three-level inverters, with the elimination of the common mode voltage over the entire modulation range. The DC link power supply requirement is also optimized by means of DC link capacitor voltage balancing, with PWM control., using only inverter switching state redundancies. The proposed power circuit gives a simple power bits structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bull sperm plasma and outer acrosomal membranes have been isolated by discontinuous sucrose density gradient centrifugation and Ca2+-ATPase activity has been determined for both the membranes. Pyrene excimer fluorescence and diphenylhexatriene fluorescence polarization studies show that the lipid phase of the sperm plasma membranes is more fluid than the lipids of the outer acrosomal membranes. Approximately, a three fold increase in the cholesterol content has been found in the outer acrosomal membranes as compared to that in the plasma membranes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

previous termBull spermnext term heads and tails have been separated by proteolytic digestion (trypsin) and previous termplasma membranesnext term have been isolated, using discontinuous sucrose density gradient centrifugation. previous termPlasma membranenext term bound Ca2+-ATPase is shown to be associated mostly with the tail previous termmembranes.next term Pyrene excimer fluorescence and diphenylhexatriene fluorescence polarization experiments indicate a more fluid lipid phase in the tail region. Differences in surface charge distribution have been found, using 1-anilinonaphthalene-8-sulfonate and Tb3+ as fluorescent probes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The properties of Alfven surface waves along a cylindrical plasma column surrounded by vacuum or by another plasma medium are discussed. Both symmetric (m=0) and asymmetric (m=+or-1) modes are found to be dispersive in nature. The interfacial symmetric modes propagate in a certain frequency window ( omega A1, omega As), where omega As is the Alfven surface wave frequency along the interface of two semi-infinite media; when nu A1> nu A2 these modes propagate as backward waves and when nu A1< nu A2 as forward waves. The asymmetric modes change from backward to forward waves at a critical wave number kTr approximately=1.59/a when nu A1< nu A2 or vice versa when nu A1> nu A2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Isolating, purifying, and identifying proteins in complex biological matrices is often difficult, time consuming, and unreliable. Herein we describe a rapid screening technique for proteins in biological matrices that combines selective protein isolation with direct surface enhanced Raman spectroscopy (SERS) detection. Magnetic core gold nanoparticles were synthesised, characterised, and subsequently functionalized with recombinant human erythropoietin (rHuEPO)-specific antibody. The functionalized nanoparticles were used to capture rHuEPO from horse blood plasma within 15 minutes. The selective binding between the protein and the functionalized nanoparticles was monitored by SERS. The purified protein was then released from the nanoparticles’ surface and directly spectroscopically identified on a commercial nanopillar SERS substrate. ELISA independently confirmed the SERS identification and quantified the released rHuEPO. Finally, the direct SERS detection of the extracted protein was successfully demonstrated for in-field screening by a handheld Raman spectrometer within 1 minute sample measurement time.