946 resultados para Corrugated waveguide


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The excitation of surface plasmon-polariton (SPP) waveguide modes in subwavelength dielectric ridges deposited on a thin gold film has been characterized and optimized at telecommunication wavelengths. The experimental data on the electromagnetic mode structure obtained using scanning near-field optical microscopy have been directly compared to full vectorial three-dimensional finite element method simulations. Two excitation geometries have been investigated where SPPs are excited outside or inside the dielectric tapered region adjoint to the waveguide. The dependence of the efficiency of the SPP guided mode excitation on the taper opening angle has been measured and modeled. Single-mode guiding and strong lateral mode confinement of dielectric-loaded SPP waveguide modes have been characterized with the near-field measurements and compared to the effective-index method model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Marine dinoflagellates of the genera Alexandrium are well known producers of the potent neurotoxic paralytic shellfish toxins that can enter the food web and ultimately present a serious risk to public health in addition to causing huge economic losses. Direct coastal monitoring of Alexandrium spp. can provide early warning of potential shellfish contamination and risks to consumers and so a rapid, sensitive, portable and easy-to-use assay has been developed for this purpose using an innovative planar waveguide device. The disposable planar waveguide is comprised of a transparent substrate onto which an array of toxin-protein conjugates is deposited, assembled in a cartridge allowing the introduction of sample, and detection reagents. The competitive assay format uses a high affinity antibody to paralytic shellfish toxins with a detection signal generated via a fluorescently labelled secondary antibody. The waveguide cartridge is analysed by a simple reader device and results are displayed on a laptop computer. Assay speed has been optimised to enable measurement within 15 min. A rapid, portable sample preparation technique was developed for Alexandrium spp. in seawater to ensure analysis was completed within a short period of time. The assay was validated and the LOD and CCß were determined as 12 pg/mL and 20 pg/mL respectively with an intra-assay CV of 11.3% at the CCß and an average recovery of 106%. The highly innovative assay was proven to accurately detect toxin presence in algae sampled from the US and European waters at an unprecedented cell density of 10 cells/L. © 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study details the development of a fully validated, rapid and portable sensor based method for the on-site analysis of microcystins in freshwater samples. The process employs a novel lysis method for the mechanical lysis of cyanobacterial cells, with glass beads and a handheld frother in only 10min. The assay utilises an innovative planar waveguide device that, via an evanescent wave excites fluorescent probes, for amplification of signal in a competitive immunoassay, using an anti-microcystin monoclonal with cross-reactivity against the most common, and toxic variants. Validation of the assay showed the limit of detection (LOD) to be 0.78ngmL and the CCß to be 1ngmL. Robustness of the assay was demonstrated by intra- and inter-assay testing. Intra-assay analysis had % C.V.s between 8 and 26% and recoveries between 73 and 101%, with inter-assay analysis demonstrating % C.V.s between 5 and 14% and recoveries between 78 and 91%. Comparison with LC-MS/MS showed a high correlation (R=0.9954) between the calculated concentrations of 5 different Microcystis aeruginosa cultures for total microcystin content. Total microcystin content was ascertained by the individual measurement of free and cell-bound microcystins. Free microcystins can be measured to 1ngmL, and with a 10-fold concentration step in the intracellular microcystin protocol (which brings the sample within the range of the calibration curve), intracellular pools may be determined to 0.1ngmL. This allows the determination of microcystins at and below the World Health Organisation (WHO) guideline value of 1µgL. This sensor represents a major advancement in portable analysis capabilities and has the potential for numerous other applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presented is a design methodology which permits the application of distributed coupled resonator bandpass filter principles to form wideband small-aperture evanescent-mode waveguide antenna designs. This approach permits matching of the complex antenna aperture admittance of an evanescent-mode open-ended waveguide to a real impedance generator, and thereby to a coaxial feed probe. A simulated reflection coefficient of < - 10 dB was obtained over a bandwidth of 20%, from 2.0-2.45 GHz, in a 2.58 GHz cutoff waveguide. Dielectric-filled propagating waveguide and air-filled evanescent-mode waveguide sections are used to form the resonators/coupling elements of the antenna's coupled resonator matching sections. Simulated realised gain variation from 3.4-5.0 dBi is observed across the bandwidth. The antenna's maximum aperture dimension is < 0.47 wavelength at the upper operating frequency and so it is suitable for use in a wide angle scanning phased array.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A phenomenology of distributed passive intermodulation generation in coplanar waveguide transmission line is presented. The theoretical analysis is based upon the generalised nonlinear transmission line model, which accounts for the coupling of two propagating modes. The case of weak substrate nonlinearity is considered and the model is given qualitative verification through the mapping of passive intermodulation products generated in coplanar waveguide fabricated on a commercial laminate. Implications for future research are discussed. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a technique, using the Imaginary Smith Chart, for determining the admittance of obstacles introduced into evanescent waveguide. The admittance of an inductive iris, capacitive iris, capacitive post, variable width strip and length of evanescent waveuide are investigated. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a simple method of forming a switchable radar cross-section (RCS) in evanescent waveguide.Here, the antenna can be selected to be matched to free space, or to act as an almost perfect reflector of incident energy via a single SPST switch located at the antenna aperture. With the aperture switch open, the antenna is matched over a measured bandwidth of 17.5%, from 2.35 to 2.8 GHz, for reflection coefficient <-10 dB, in 2.725 GHz cutoff waveguide. With the aperture switch closed, a minimum reflection coefficient of -2.5 dB across the bandwidth is observed, proving that the antenna has the capacity to be made RCS reconfigurable. © 2012 Wiley Periodicals, Inc. Microwave Opt Technol Lett 54:1849–1851, 2012; View this article online at wileyonlinelibrary.com. DOI 10.1002/mop.26981

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a novel antenna matching technique that uses the Imaginary Smith Chart to permit wideband matching of an evanescent open-ended waveguide antenna using a dielectric sheet air-spaced from the aperture. The fabricated antenna design is demonstrated to have a measured bandwidth of 24%, from 2.13–2.7 GHz, for reflection coefficient $qquad{<} -!!10~{rm dB}$ , with 2.725 GHz waveguide cutoff. The antenna's maximum aperture dimension is ${< 0.5}lambda_{0}$ at the upper frequency in the bandwidth and so it is suitable for use in a wide angle scanning phased array

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pressure and velocity field in a one-dimensional acoustic waveguide can be sensed in a non-intrusive manner using spatially distributed microphones. Experimental characterization with sensor arrangements of this type has many applications in measurement and control. This paper presents a method for measuring the acoustic variables in a duct under fluctuating propagation conditions with specific focus on in-system calibration and tracking of the system parameters of a three-microphone measurement configuration. The tractability of the non-linear optimization problem that results from taking a parametric approach is investigated alongside the influence of extraneous measurement noise on the parameter estimates. The validity and accuracy of the method are experimentally assessed in terms of the ability of the calibrated system to separate the propagating waves under controlled conditions. The tracking performance is tested through measurements with a time-varying mean flow, including an experiment conducted under propagation conditions similar to those in a wind instrument during playing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel multiplex microarray has been developed for the detection of five groups of harmful algal and cyanobacterial toxins found in marine, brackish, and freshwater environments including domoic acid (DA), okadaic acid (OA, and analogues), saxitoxin (STX, and analogues), cylindrospermopsin (CYN) and microcystins (MC, and analogues). The sensitivity and specificity were determined and feasibility to be used as a screening tool investigated. Results for algal/cyanobacterial cultures (n = 12) and seawater samples (n = 33) were compared to conventional analytical methods, such as high performance liquid chromatography (HPLC) and liquid chromatography tandem mass spectrometry (LC-MS/MS). Detection limits for the 15 min assay were 0.37, 0.44, 0.05, 0.08, and 0.40 ng/mL for DA, OA, STX, CYN, and MC, respectively. The correlation of data obtained from the microarray compared to conventional analysis for the 12 cultures was r(2) = 0.83. Analysis of seawater samples showed that 82, 82, 70, 82, and 12% of samples were positive (>IC20) compared to 67, 55, 36, 0, and 0% for DA, OA, STX, CYN, and MC, respectively, for conventional analytical methods. The discrepancies in results can be attributed to the enhanced sensitivity and cross-reactivity profiles of the antibodies in the MBio microarray. The feasibility of the microarray as a rapid, easy to use, and highly sensitive screening tool has been illustrated for the five-plex detection of biotoxins. The research demonstrates an early warning screening assay to support national monitoring agencies by providing a faster and more accurate means of identifying and quantifying harmful toxins in water samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dual/triband evanescent waveguide antenna elementis presented. The antenna operates in the 740–790, 1.9–2.2, and2.5–2.7 GHz frequency bands. It measures 55 3 27.5 3 53 mm3andoccupies a small volume making it attractive for miniaturized applica-tions