958 resultados para Cooling ponds


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A detailed ecological, micro-structural and skeletal Sr/Ca study of a 3.42 m thick Goniopora reef profile from an emerged Holocene reef terrace at the northern South China Sea reveals at least nine abrupt massive Goniopora stress and mortality events occurred in winter during the 7.0-7.5 thousand calendar years before present (cal. ka BP) (within the Holocene climatic optimum). Whilst calculated Sr/Ca-SST (sea surface temperature) maxima during this period are comparable to those in the 1990s, Sr/Ca-SST minima are significantly lower, probably due to stronger winter monsoons. Such generally cooler winters, superimposed by further exceptional winter cooling on inter-annual to decadal scales, may have caused stress and mortality of the corals about every 50 years. Sea level rose by similar to 3.42 m during this period, with present sea-level reached at similar to 7.3 ka BP and a sea-level highstand of at least similar to 1.8 m occurred at similar to 7.0 ka. The results show that it took about 20-25 years for a killed Goniopora coral reef to recover. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe an implementation of quantum error correction that operates continuously in time and requires no active interventions such as measurements or gates. The mechanism for carrying away the entropy introduced by errors is a cooling procedure. We evaluate the effectiveness of the scheme by simulation, and remark on its connections to some recently proposed error prevention procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability to track large numbers of individuals and families is a key determinant of the power and precision of breeding programs, including the capacity to quantify interactions between genotypes and their environment. Until recently, most family based selective breeding programs for shrimp, and other highly fecund aquaculture species, have been restricted by the number of animals that can be physically tagged and individually selected. Advances in the development of molecular markers, such as microsatellite loci, are now providing the means to track large numbers of individuals and families in commercial production systems. In this study microsatellites, coupled with DNA parentage analyses, were used to determine the relative performance of 22 families of R japonicus reared in commercial production ponds. In the experimental design 6000 post-larvae from each of 22 families, whose maternal parents had been genotyped at 8 microsatellite loci, were stocked into each of four I ha ponds. After 6 months the ponds were harvested and a total of 6000 individuals were randomly weighed from each pond. Mean wet weight of the shrimp from one pond was significantly lower than that of the other three ponds demonstrating a possible pond effect on growth rate. The representation of families in the top 10% of each pond's weight distribution was then determined by randomly genotyping up to 300 individuals from this upper weight class. Parentage analyses based on individual genotypic data demonstrated that some families were over-represented in the top 10% in all ponds, while others were under-represented due to slower growth rates. The results also revealed some weak, but significant, male genotype x environment (G x E) interactions in the expression of shrimp growth for some families. This indicates that G x E effects may need to be factored into future R japonicus selective breeding programs. This study demonstrated the utility of DNA parentage analyses for tracking individual family performance in communally stocked shrimp pond populations and, its application to examining G x E effects on trait expression under commercial culture conditions. Crown Copyright (c) 2005 Published by Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using modifications to the Rappaz-Drezet-Gremaud hot tearing model, and using empirical equations developed for grain size and dendrite arm spacing (DAS) on the addition of grain refiner for a range of cooling rates, the effect of grain refinement and cooling rate on hot tearing susceptibility has been analysed. It was found that grain refinement decreased the grain size and made the grain morphology more globular. Therefore refining the grain size of an equiaxed dendritic grain decreased the hot tearing susceptibility. However, when the alloy was grain refined such that globular grain morphologies where obtained, further grain refinement increased the hot tearing susceptibility. Increasing the cooling decreased the grain size and made the grain morphology more dendritic and therefore increased the likelihood of hot tearing. The effect was particularly strong for equiaxed dendritic grain morphologies; hence grain refinement is increasingly important at high cooling rates to obtain more globular grain morphologies to reduce the hot tearing susceptibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eighteen Angus steers exposed to high heat load conditions were used to assess the effectiveness of four spray cooling systems, on reducing the effects of heat load, the impact on microclimate and water usage. The steers were housed in groups of nine in a fully enclosed shed and were exposed to high heat load conditions for four days. The cooling systems used were water applied via a hose, via overhead sprinklers, via sprinklers at leg height and via misters. The water used was approximately 31 oC and contained 3% NaCl. Fans were used to ensure adequate air movement over the cattle. The animal parameters measured were feed intake, respiration rate, panting score and behaviour. Climatic factors were ambient temperature and wet bulb temperature. Ammonia levels were also measured. The hose, overhead sprinklers and misting were successful in reducing heat load on the cattle. The leg wetting system did not work because the dominant cattle blocked access to the sprinklers. The misting system used the most water (5483 L) and the hose the least (845 L). The application of water had minor impacts on wet bulb temperature, but resulted in significant reductions in dry bulb temperatures.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article I synthesise research and theory that advance our understanding of creativity and innovation implementation in groups at work. It is suggested that creativity occurs primarily at the early stages of innovation processes with innovation implementation later. The influences of task characteristics, group knowledge diversity and skill, external demands, integrating group processes and intragroup safety are explored. Creativity, it is proposed, is hindered whereas perceived threat, uncertainty or other high levels of demands aid the implementation of innovation. Diversity of knowledge and skills is a powerful predictor of innovation, but integrating group processes and competencies are needed to enable the fruits of this diversity to be harvested. The implications for theory and practice are also explored.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work, the more important parameters of the heat pump system and of solar assisted heat pump systems were analysed in a quantitative way. Ideal and real Rankine cycles applied to the heat pump, with and without subcooling and superheating were studied using practical recommended values for their thermodynamics parameters. Comparative characteristics of refrigerants here analysed looking for their applicability in heat pumps for domestic heating and their effect in the performance of the system. Curves for the variation of the coefficient of performance as a function of condensing and evaporating temperatures were prepared for R12. Air, water and earth as low-grade heat sources and basic heat pump design factors for integrated heat pumps and thermal stores and for solar assisted heat pump-series, parallel and dual-systems were studied. The analysis of the relative performance of these systems demonstrated that the dual system presents advantages in domestic applications. An account of energy requirements for space and hater heating in the domestic sector in the O.K. is presented. The expected primary energy savings by using heat pumps to provide for the heating demand of the domestic sector was found to be of the order of 7%. The availability of solar energy in the U.K. climatic conditions and the characteristics of the solar radiation here studied. Tables and graphical representations in order to calculate the incident solar radiation over a tilted roof were prepared and are given in this study in section IV. In order to analyse and calculate the heating load for the system, new mathematical and graphical relations were developed in section V. A domestic space and water heating system is described and studied. It comprises three main components: a solar radiation absorber, the normal roof of a house, a split heat pump and a thermal store. A mathematical study of the heat exchange characteristics in the roof structure was done. This permits to evaluate the energy collected by the roof acting as a radiation absorber and its efficiency. An indication of the relative contributions from the three low-grade sources: ambient air, solar boost and heat loss from the house to the roof space during operation is given in section VI, together with the average seasonal performance and the energy saving for a prototype system tested at the University of Aston. The seasonal performance as found to be 2.6 and the energy savings by using the system studied 61%. A new store configuration to reduce wasted heat losses is also discussed in section VI.