972 resultados para Constant pressure test
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The characterization of the hyperbolic power-time (P-tlim) relationship using a two-parameter model implies that exercise tolerance above the asymptote (Critical Power; CP), i.e. within the severe intensity domain, is determined by the curvature (W') of the relationship. The purposes of this study were (1) to test whether the amount of work above CP (W>CP) remains constant for varied work rate experiments of high volatility change and (2) to ascertain whether W' determines exercise tolerance within the severe intensity domain. Following estimation of CP (208 ± 19 W) and W' (21.4 ± 4.2 kJ), 14 male participants (age: 26 ± 3; peak [Formula: see text]: 3708 ± 389 ml.min-1) performed two experimental trials where the work rate was initially set to exhaust 70% of W' in 3 ('THREE') or 10 minutes ('TEN') before being subsequently dropped to CP plus 10 W. W>CP for TEN (104 ± 22% W') and W' were not significantly different (P>0.05) but lower than W>CP for THREE (119 ± 17% W', P<0.05). For both THREE (r = 0.71, P<0.01) and TEN (r = 0.64, P<0.01), a significant bivariate correlation was found between W' and tlim. W>CP and tlim can be greater than predicted by the P-tlim relationship when a decrement in the work rate of high-volatility is applied. Exercise tolerance can be enhanced through a change in work rate within the severe intensity domain. W>CP is not constant.
Resumo:
The aim of this study was to determine whether high blood pressure (HBP) is associated with sedentary behavior in young people even after controlling for potential confounders (gender, age, socioeconomic level, tobacco, alcohol, obesity and physical activity). In this epidemiological study, 1231 adolescents were evaluated. Blood pressure was measured with an oscillometric device and waist circumference with an inextensible tape. Sedentary behavior (watching television, computer use and playing video games) and physical activity were assessed by a questionnaire. We used mean and standard deviation to describe the statistical analysis, and the association between HBP and sedentary behavior was assessed by the chi-squared test. Binary logistic regression was used to observe the magnitude of association and cluster analyses (sedentary behavior and abdominal obesity; sedentary behavior and physical inactivity). HBP was associated with sedentary behaviors [odds ratio (OR) = 2.21, 95% confidence interval (CI) = 1.41-3.96], even after controlling for various confounders (OR = 1.68, CI = 1.03-2.75). In cluster analysis the combination of sedentary behavior and elevated abdominal obesity contributed significantly to an increased likelihood of having HBP (OR = 13.51, CI 7.21-23.97). Sedentary behavior was associated with HBP, and excess fat in the abdominal region contributed to the modulation of this association.
Resumo:
The aim of this study was to evaluate the effects of simulated pulpal pressure (SPP) on the variation of intrapulpal temperature (ΔT) and microtensile bond strength (μTBS) to dentin submitted to an adhesive technique using laser irradiation. One hundred sound human molars were randomly divided into two groups (n = 50), according to the presence or absence of SPP (15 cm H2O). Each group was divided into five subgroups (n = 10) according to Nd:YAG laser energy (60, 80, 100, 120, 140 mJ/pulse). The samples were sequentially treated with the following: 37 % phosphoric acid, adhesive (Scotchbond Universal), irradiation with Nd:YAG laser (60 s), and light curing (10 s). ΔT was evaluated during laser irradiation using a type K thermocouple. Next, a composite resin block was build up onto the irradiated area. After 48 h, samples were submitted to microtensile test (10 kgf load cell, 0.5 mm/min). Data were analyzed by two-way ANOVA and Tukey tests (p = 0.05). ANOVA revealed significant differences for ΔT and TBS in the presence of SPP. For ΔT, the highest mean (14.3 ± 3.23 °C)(A) was observed in 140 mJ and without SPP. For μTBS, the highest mean (33.4 ± 4.15 MPa)(A) was observed in 140 mJ and without SPP. SPP significantly reduced both ΔT and μTBS during adhesive procedures, lower laser energy parameters resulted in smaller ΔT, and the laser parameters did not influence the μTBS values.
Resumo:
Pós-graduação em Fisioterapia - FCT
Resumo:
Anaerobic efforts are commonly required through repeated sprint during efforts in many sports, making the anaerobic pathway a target of training. Nevertheless, to identify improvements on such energetic way it is necessary to assess anaerobic capacity or power, which is usually complex. For this purpose, authors have postulated the use of short running performances to anaerobic ability assessment. Thus, the aim of this study was to find a relationship between running performances on anaerobic power, anaerobic capacity or repeated sprint ability. Methods Thirteen military performed maximal running of 50 (P50), 100 (P100) and 300 (P300) m on track, beyond of running-based anaerobic sprint test (RAST; RSA and anaerobic power test), maximal anaerobic running test (MART; RSA and anaerobic capacity test) and the W′ from critical power model (anaerobic capacity test). Results By RAST variables, peak and average power (absolute and relative) and maximum velocity were significantly correlated with P50 (r = −0.68, p = 0.03 and −0.76, p = 0.01; −0.83, p < 0.01 and −0.83, p < 0.01; and −0.78, p < 0.01), respectively. The maximum intensity of MART was negatively and significantly correlated with P100 (r = −0.59) and W′ was not statistically correlated with any of the performances. Conclusion MART and W′ were not correlated with short running performances, having a weak performance predicting probably due to its longer duration in relation to assessed performances. Observing RAST outcomes, we postulated that such a protocol can be used during daily training as short running performance predictor.
Resumo:
Background: Walking speed seems to be related to aerobic capacity, lower limb strength, and functional mobility, however it is not clear whether there is a direct relationship between improvement in muscle strength and gait performance in early postmenopausal women. Objective: To evaluate the effect of muscle strengthening exercises on the performance of the 6-minute walk test in women within 5 years of menopause. Methods: The women were randomized into control group (n=31), which performed no exercise, and exercise group (n=27), which performed muscle strengthening exercises. The exercises were performed twice a week for 3 months. The exercise protocol consisted of warm-up, stretching, and strengthening of the quadriceps, hamstring, calf, tibialis anterior, gluteus maximus, and abdominal muscles, followed by relaxation. Muscular strength training started with 60% of 1MR (2 series of 10-15 repetitions), reaching 85% until the end of the 3-month period (4 series of 6 repetitions each). Results: The between-group comparisons pre- and post-intervention did not show any difference in distance walked, heart rate or blood pressure (p>0.05), but showed differences in muscle strength post-intervention, with the exercise group showing greater strength (p<0.05). In the within-group comparison, there were differences in final heart rate and quadriceps and hamstring strength pre- and post-intervention in the exercise group (p<0.05). Conclusion: The results suggest that muscle strengthening of the lower limbs did not improve performance in the 6-minute walk test in this population of postmenopausal women. Trial registration ACTRN12609001053213.
Resumo:
Background: Arterial hypertension is an important risk factor for Lower-Limb Occlusive Arterial Disease (LLOAD). However, the correlation between blood pressure and pulse pressure (PP) with LLOAD severity and functional impairment resulting from this disease is not well established in the Brazilian population. Objective: To verify whether there is a correlation between blood pressure, PP, LLOAD severity and functional capacity in patients with symptomatic LLOAD. Methods: A total of 65 patients (62.2 + 8.1 years, 56.9% males) were evaluated. They were divided into two groups: normal (A) and high (B) blood pressure. LLOAD severity was assessed using the ankle-brachial index (ABI) and functional capacity by the total and pain-free walking distance at the 6-minute walking test (6MWT). Results: Group A consisted of 17 (26.1%) patients. The systolic (SBP), diastolic blood pressure (DBP), and PP were, respectively, 125.4 +/- 11.7, 74.5 +/- 9.1 and 50.9 +/- 10.0 mmHg in group A and 160.7 +/- 19.6, 90.0 +/- 12.2 and 70.7 +/- 20.2 mmHg in group B. The ABI was significantly lower in group B (0.66 +/- 0.12 vs. 0.57 +/- 0.13, p < 0.05). SBP and PP correlated with LLOAD severity and the distances walked at the 6MWT. Patients with PP > 40 mmHg walked shorter distances. Conclusion: SBP and PP significantly correlated with the distances walked in the 6MWT, suggesting they are clinical markers of functional capacity impairment in patients with symptomatic LLOAD. (Arq Bras Cardiol 2012; 98(2): 161-166)
Resumo:
Objective: To investigate the use of nasal intermittent positive pressure ventilation (NIPPV) in level three neonatal intensive care units (NICU) in northeastern Brazil. Methods: This observational cross-sectional survey was conducted from March 2009 to January 2010 in all level three NICUs in northeastern Brazil that are registered in the Brazilian Registry of Health Establishments (Cadastro Nacional de Estabelecimentos de Saude, CNES) of the Ministry of Health. Questionnaires about the use of NIPPV were sent to the NICU directors in each institution. Statistical analysis was conducted using the software Epi-Info 6.04 and double data entry. A chi-square test was used to compare variables, and the level of statistical significance was set at p <= 0.05. Results: This study identified 93 level three NICUs in northeastern Brazil registered in CNES, and 87% answered the study questionnaire. Most classified themselves as private institutions (30.7%); 98.7% used NIPPV; 92.8 % adapted mechanical ventilators for NIPPV and used short binasal prongs as the interface (94.2%). Only 17.3% of the units had a protocol for the use of NIPPV. Mean positive inspiratory pressure and positive end-expiratory pressure were 20.0 cmH(2)O (standard deviation [SD]: 4.47) and 5.0 cmH(2)O (SD: 0.84). Conclusion: NICUs in northeastern Brazil use nasal intermittent positive pressure ventilation, but indications and ventilation settings are not the same in the different institutions.
Resumo:
Background. Acute normovolemic hemodilution (ANH) is an alternative to blood transfusion in surgeries involving blood loss. This experimental study was designed to evaluate whether pulse pressure variation (PPV) would be an adequate tool for monitoring changes in preload during ANH, as assessed by transesophageal echocardiography. Methods. Twenty-one anesthetized and mechanically ventilated pigs were randomized into three groups: CTL (control), HES (hemodilution with 6% hydroxyethyl starch at a 1:1 ratio) or NS (hemodilution with saline 0.9% at a 3:1 ratio). Hemodilution was performed in animals of groups NS and HES in two stages, with target hematocrits 22% and 15%, achieved at 30-minute intervals. After two hours, 50% of the blood volume withdrawn was transfused and animals were monitored for another hour. Statistical analysis was based on ANOVA for repeated measures followed by multiple comparison test (P<0.05). Pearson's correlations were performed between changes in left ventricular end-diastolic volume (LVEDV) and PPV, central venous pressure (CVP) and pulmonary artery occlusion pressure (PAOP). Results. Group NS received a significantly greater amount of fluids during ANH (NS, 900 +/- 168 mL vs. HES, 200 +/- 50 mL, P<0.05) and presented greater urine output (NS, 2643 +/- 1097mL vs. HES, 641 +/- 338mL, P<0.001). Significant decreases in LVEDV were observed in group NS from completion of ANH until transfusion. In group HES, only increases in LVEDV were observed, at the end of ANH and at transfusion. Such changes in LVEDV (Delta LVEDV) were better reflected by changes in PPV (Delta PPV, R=-0.62) than changes in CVP (Delta CVP R=0.32) or in PAOP (Delta PAOP, R=0.42, respectively). Conclusion. Changes in preload during ANH were detected by changes in PPV. Delta PPV was superior to Delta PAOP and Delta CVP to this end. (Minerva Anestesiol 2012;78:426-33)
Resumo:
We propose an alternative, nonsingular, cosmic scenario based on gravitationally induced particle production. The model is an attempt to evade the coincidence and cosmological constant problems of the standard model (Lambda CDM) and also to connect the early and late time accelerating stages of the Universe. Our space-time emerges from a pure initial de Sitter stage thereby providing a natural solution to the horizon problem. Subsequently, due to an instability provoked by the production of massless particles, the Universe evolves smoothly to the standard radiation dominated era thereby ending the production of radiation as required by the conformal invariance. Next, the radiation becomes subdominant with the Universe entering in the cold dark matter dominated era. Finally, the negative pressure associated with the creation of cold dark matter (CCDM model) particles accelerates the expansion and drives the Universe to a final de Sitter stage. The late time cosmic expansion history of the CCDM model is exactly like in the standard Lambda CDM model; however, there is no dark energy. The model evolves between two limiting (early and late time) de Sitter regimes. All the stages are also discussed in terms of a scalar field description. This complete scenario is fully determined by two extreme energy densities, or equivalently, the associated de Sitter Hubble scales connected by rho(I)/rho(f) = (H-I/H-f)(2) similar to 10(122), a result that has no correlation with the cosmological constant problem. We also study the linear growth of matter perturbations at the final accelerating stage. It is found that the CCDM growth index can be written as a function of the Lambda growth index, gamma(Lambda) similar or equal to 6/11. In this framework, we also compare the observed growth rate of clustering with that predicted by the current CCDM model. Performing a chi(2) statistical test we show that the CCDM model provides growth rates that match sufficiently well with the observed growth rate of structure.
Resumo:
Background: Non-adherence to treatment has been identified as the main cause of uncontrolled blood pressure (BP), and may represent a greater risk in older individuals. Objective: The aim of this study was to evaluate and compare the rate of adherence to hypertension treatment using different methods, to estimate the BP control rate, and to observe if there is an association between BP control and adherence. Methods: Treatment adherence was evaluated in older patients with hypertension, followed by the public primary health care, through four methods, including the Morisky-Green test (reference), the Attitude regarding the Medication Intake questionnaire (AMI), an evaluation of adherence by the nurse in the office (Nurse Adherence Evaluation - NAE), and at home (Home Adherence Evaluation - HAE). Salt intake was estimated by 24-hour sodium urinary excretion. BP control was assessed by the awake ambulatory blood pressure monitoring. Results: Concordance between the Morisky-Green test and AMI (Kappa=0.27) or NAE (Kappa=0.05) was poor. There was a moderate concordance between the Morisky-Green test and HAE. Eighty percent had controlled BP, including 42% with white-coat effect. The group with lower salt excretion informed to avoid salt intake more times (p<0.001) and had better medication adherence (p<0.001) than the higher salt excretion group. Conclusion: The evaluated tests did not show a good concordance to the Morisky-Green test. Adherence to hypertension treatment was low; however, there was a high rate of BP control when subjects with the white-coat effect were included in the analysis. (Arq Bras Cardiol 2012;99(1):636-641)
Resumo:
The objective of this paper is to show the dependence relationship between the crystallographic orientations upon brittle-to-ductile transition during diamond turning of monocrystalline silicon. Cutting tests were performed using a -5 degrees rake angle round nose diamond tool at different machining scales. At the micrometre level, the feedrate was kept constant at 2.5 micrometres per revolution (mu m/r), and the depth of cut was varied from 1 to 5 mu m. At the submicrometre level, the depth of cut was kept constant at 500 nm and the feedrate varied from 5 to 10 mu m/r. At the micrometre level, the uncut shoulder generated with an interrupted cutting test procedure provided a quantitative measurement of the ductile-to-brittle transition. Results show that the critical chip thickness in silicon for ductile material removal reaches a maximum of 285 nm in the [100] direction and a minimum of 115 nm in the [110] direction, when the depth of cut was 5 mu m. It was found that when a submicrometre depth of cut was applied, microcracks were revealed in the [110] direction, which is the softer direction in silicon. Micro Raman spectroscopy was used to estimate surface residual stress after machining. Compressive residual stress in the range 142 MPa and smooth damage free surface finish was probed in the [100] direction for a depth of cut of 5 mu m, whereas residual stresses in the range 350 MPa and brittle damage was probed in the [110] direction for a depth of cut of 500 nm.
Resumo:
Background: Exercise training (ET) can reduce blood pressure (BP) and prevent functional disability. However, the effects of low volumes of training have been poorly studied, especially in elderly hypertensive patients. Objectives: To investigate the effects of a multi-component ET program (aerobic training, strength, flexibility, and balance) on BP, physical fitness, and functional ability of elderly hypertensive patients. Methods: Thirty-six elderly hypertensive patients with optimal clinical treatment underwent a multi-component ET program: two 60-minute sessions a week for 12 weeks at a Basic Health Unit. Results: Compared to pre-training values, systolic and diastolic BP were reduced by 3.6% and 1.2%, respectively (p < 0.001), body mass index was reduced by 1.1% (p < 0.001), and peripheral blood glucose was reduced by 2.5% (p= 0.002). There were improvements in all physical fitness domains: muscle strength (chair-stand test and elbow flexor test; p < 0.001), static balance test (unipedal stance test; p < 0.029), aerobic capacity (stationary gait test; p < 0.001), except for flexibility (sit and reach test). Moreover, there was a reduction in the time required to perform two functional ability tests: "put on sock" and "sit down, stand up, and move around the house" (p < 0.001). Conclusions: Lower volumes of ET improved BP, metabolic parameters, and physical fitness and reflected in the functional ability of elderly hypertensive patients. Trial Registration RBR-2xgjh3.
Resumo:
Background: Pulmonary hypertension is associated with a worse prognosis after cardiac transplantation. The pulmonary hypertension reversibility test with sodium nitroprusside (SNP) is associated with a high rate of systemic arterial hypotension, ventricular dysfunction of the transplanted graft and high rates of disqualification from transplantation. Objective: This study was aimed at comparing the effects of sildenafil (SIL) and SNP on hemodynamic, neurohormonal and echocardiographic variables during the pulmonary reversibility test. Methods: The patients underwent simultaneously right cardiac catheterization, echocardiography, BNP measurement, and venous blood gas analysis before and after receiving either SNP (1 - 2 mu g/kg/min) or SIL (100 mg, single dose). Results: Both drugs reduced pulmonary hypertension, but SNP caused a significant systemic hypotension (mean blood pressure - MBP: 85.2 vs. 69.8 mm Hg; p < 0.001). Both drugs reduced cardiac dimensions and improved left cardiac function (SNP: 23.5 vs. 24.8%, p = 0.02; SIL: 23.8 vs. 26%, p < 0.001) and right cardiac function (SIL: 6.57 +/- 2.08 vs. 8.11 +/- 1.81 cm/s, p = 0.002; SNP: 6.64 +/- 1.51 vs. 7.72 +/- 1.44 cm/s, p = 0.003), measured through left ventricular ejection fraction and tissue Doppler, respectively. Sildenafil, contrary to SNP, improved venous oxygen saturation, measured on venous blood gas analysis. Conclusion: Sildenafil and SNP are vasodilators that significantly reduce pulmonary hypertension and cardiac geometry, in addition to improving biventricular function. Sodium nitroprusside, contrary to SIL, was associated with systemic arterial hypotension and worsening of venous oxygen saturation. (Arq Bras Cardiol 2012;99(3):848-856)