894 resultados para Computer-Aided Engineering (CAD, CAE) and design
Resumo:
Nowadays, in Ubiquitous computing scenarios users more and more require to exploit online contents and services by means of any device at hand, no matter their physical location, and by personalizing and tailoring content and service access to their own requirements. The coordinated provisioning of content tailored to user context and preferences, and the support for mobile multimodal and multichannel interactions are of paramount importance in providing users with a truly effective Ubiquitous support. However, so far the intrinsic heterogeneity and the lack of an integrated approach led to several either too vertical, or practically unusable proposals, thus resulting in poor and non-versatile support platforms for Ubiquitous computing. This work investigates and promotes design principles to help cope with these ever-changing and inherently dynamic scenarios. By following the outlined principles, we have designed and implemented a middleware support platform to support the provisioning of Ubiquitous mobile services and contents. To prove the viability of our approach, we have realized and stressed on top of our support platform a number of different, extremely complex and heterogeneous content and service provisioning scenarios. The encouraging results obtained are pushing our research work further, in order to provide a dynamic platform that is able to not only dynamically support novel Ubiquitous applicative scenarios by tailoring extremely diverse services and contents to heterogeneous user needs, but is also able to reconfigure and adapt itself in order to provide a truly optimized and tailored support for Ubiquitous service provisioning.
Resumo:
Der Einsatz von Penningfallen in der Massenspektrometrie hat zu einem einmaligen Genauigkeitssprung geführt. Dadurch wurden Massenwerte verschiedenster Atome zu wichtigen Eingangsparametern bei immer mehr physikalischen Fragestellungen. Die Massenspektrometrie mit Hilfe von Penningfallen basiert auf der Bestimmung der freien Zyklotronfrequenz eines Ions in einem homogenen Magnetfeld νc=qB/(2πm). Sie wird mit Flugzeitmethode (TOF-ICR) bestimmt, wobei eine relative Massenungenauigkeit δm/m von wenigen 10^-9 bei Nukliden mit Lebensdauern von <500 ms erreicht wird. Dies wurde durch die im Rahmen dieser Arbeit erstmals in der Penningfallen-Massenspektrometrie eingesetzten Ramsey-Methode möglich. Dabei werden zeitlich separierte, oszillierenden Feldern zur resonanten Ionenanregung genutzt, um die Frequenzmessung durch die Flugzeitmethode zu verbessern. Damit wurden am Penningfallenmassenspektrometer ISOLTRAP an ISOLDE/CERN die Massen der Nuklide 26,27Al und 38,39Ca bestimmt. Alle Massen wurden in die „Atomic Mass Evaluation“ eingebettet. Die Massenwerte von 26Al und 38Ca dienten insbesondere zu Tests des Standardmodells. Um mit Massenwerten fundamentale Symmetrien oder die Quantenelektrodynamik (QED) in extremen Feldern zu testen wurde ein neues Penningfallenprojekt (PENTATRAP) für hochpräzise Massenmessungen an hochgeladenen Ionen konzipiert. In dieser Doktorarbeit wurde vornehmlich die Entwicklung der Penningfallen betrieben. Eine Neuerung bei Penningfallenexperimenten ist dabei die permanente Beobachtung des Magnetfeldes B und seiner zeitlichen Fluktuationen durch so genannte „Monitorfallen“.
Resumo:
Reliable electronic systems, namely a set of reliable electronic devices connected to each other and working correctly together for the same functionality, represent an essential ingredient for the large-scale commercial implementation of any technological advancement. Microelectronics technologies and new powerful integrated circuits provide noticeable improvements in performance and cost-effectiveness, and allow introducing electronic systems in increasingly diversified contexts. On the other hand, opening of new fields of application leads to new, unexplored reliability issues. The development of semiconductor device and electrical models (such as the well known SPICE models) able to describe the electrical behavior of devices and circuits, is a useful means to simulate and analyze the functionality of new electronic architectures and new technologies. Moreover, it represents an effective way to point out the reliability issues due to the employment of advanced electronic systems in new application contexts. In this thesis modeling and design of both advanced reliable circuits for general-purpose applications and devices for energy efficiency are considered. More in details, the following activities have been carried out: first, reliability issues in terms of security of standard communication protocols in wireless sensor networks are discussed. A new communication protocol is introduced, allows increasing the network security. Second, a novel scheme for the on-die measurement of either clock jitter or process parameter variations is proposed. The developed scheme can be used for an evaluation of both jitter and process parameter variations at low costs. Then, reliability issues in the field of “energy scavenging systems” have been analyzed. An accurate analysis and modeling of the effects of faults affecting circuit for energy harvesting from mechanical vibrations is performed. Finally, the problem of modeling the electrical and thermal behavior of photovoltaic (PV) cells under hot-spot condition is addressed with the development of an electrical and thermal model.
Resumo:
This study is focused on radio-frequency inductively coupled thermal plasma (ICP) synthesis of nanoparticles, combining experimental and modelling approaches towards process optimization and industrial scale-up, in the framework of the FP7-NMP SIMBA European project (Scaling-up of ICP technology for continuous production of Metallic nanopowders for Battery Applications). First the state of the art of nanoparticle production through conventional and plasma routes is summarized, then results for the characterization of the plasma source and on the investigation of the nanoparticle synthesis phenomenon, aiming at highlighting fundamental process parameters while adopting a design oriented modelling approach, are presented. In particular, an energy balance of the torch and of the reaction chamber, employing a calorimetric method, is presented, while results for three- and two-dimensional modelling of an ICP system are compared with calorimetric and enthalpy probe measurements to validate the temperature field predicted by the model and used to characterize the ICP system under powder-free conditions. Moreover, results from the modeling of critical phases of ICP synthesis process, such as precursor evaporation, vapour conversion in nanoparticles and nanoparticle growth, are presented, with the aim of providing useful insights both for the design and optimization of the process and on the underlying physical phenomena. Indeed, precursor evaporation, one of the phases holding the highest impact on industrial feasibility of the process, is discussed; by employing models to describe particle trajectories and thermal histories, adapted from the ones originally developed for other plasma technologies or applications, such as DC non-transferred arc torches and powder spherodization, the evaporation of micro-sized Si solid precursor in a laboratory scale ICP system is investigated. Finally, a discussion on the role of thermo-fluid dynamic fields on nano-particle formation is presented, as well as a study on the effect of the reaction chamber geometry on produced nanoparticle characteristics and process yield.
Resumo:
In recent years, the use of Reverse Engineering systems has got a considerable interest for a wide number of applications. Therefore, many research activities are focused on accuracy and precision of the acquired data and post processing phase improvements. In this context, this PhD Thesis deals with the definition of two novel methods for data post processing and data fusion between physical and geometrical information. In particular a technique has been defined for error definition in 3D points’ coordinates acquired by an optical triangulation laser scanner, with the aim to identify adequate correction arrays to apply under different acquisition parameters and operative conditions. Systematic error in data acquired is thus compensated, in order to increase accuracy value. Moreover, the definition of a 3D thermogram is examined. Object geometrical information and its thermal properties, coming from a thermographic inspection, are combined in order to have a temperature value for each recognizable point. Data acquired by an optical triangulation laser scanner are also used to normalize temperature values and make thermal data independent from thermal-camera point of view.
Resumo:
A two-dimensional model to analyze the distribution of magnetic fields in the airgap of a PM electrical machines is studied. A numerical algorithm for non-linear magnetic analysis of multiphase surface-mounted PM machines with semi-closed slots is developed, based on the equivalent magnetic circuit method. By using a modular structure geometry, whose the basic element can be duplicated, it allows to design whatever typology of windings distribution. In comparison to a FEA, permits a reduction in computing time and to directly changing the values of the parameters in a user interface, without re-designing the model. Output torque and radial forces acting on the moving part of the machine can be calculated. In addition, an analytical model for radial forces calculation in multiphase bearingless Surface-Mounted Permanent Magnet Synchronous Motors (SPMSM) is presented. It allows to predict amplitude and direction of the force, depending on the values of torque current, of levitation current and of rotor position. It is based on the space vectors method, letting the analysis of the machine also during transients. The calculations are conducted by developing the analytical functions in Fourier series, taking all the possible interactions between stator and rotor mmf harmonic components into account and allowing to analyze the effects of electrical and geometrical quantities of the machine, being parametrized. The model is implemented in the design of a control system for bearingless machines, as an accurate electromagnetic model integrated in a three-dimensional mechanical model, where one end of the motor shaft is constrained to simulate the presence of a mechanical bearing, while the other is free, only supported by the radial forces developed in the interactions between magnetic fields, to realize a bearingless system with three degrees of freedom. The complete model represents the design of the experimental system to be realized in the laboratory.
Resumo:
In questo elaborato si affrontano problematiche cliniche legate ai traumi gravi della cute in cui è necessario intervenire chirurgicamente per ripristinare una situazione normale: si approfondisce lo studio della fisiologia del tessuto, la classificazione dei gradi delle ustioni della pelle, la guarigione delle ferite e la meccanica della cute. Il trapianto di tessuto autologo costituisce la soluzione più efficace e con minori complicazioni. Tuttavia il paziente potrebbe non presentare una superficie di cute disponibile sufficientemente estesa, per cui si ricorre ad altri metodi. In primo luogo, si effettuano degli allotrapianti di tessuto di donatore cadavere prelevati secondo le normative vigenti e conservati attraverso le varie tecniche, il cui sviluppo ha consentito una durata di conservazione maggiore; mentre la glicerolizzazione abbatte al 100% il rischio di trasmissione di patologie e lo sviluppo di microorganismi, la crioconservazione preserva la vitalità del tessuto. La chirurgia utilizzata per queste operazioni si avvale di tecnologie innovative come la Tecnologia a Pressione Negativa. Un'alternativa necessaria per sopperire all'ingente richiesta di tessuto di donatore sono i sostituti cutanei, che presentano un grande potenziale per il futuro. Per eliminare totalmente il rischio di rigetto sarebbe necessario personalizzare il costrutto utilizzando cellule autologhe, ma la ricerca è stata rallentata da minori investimenti da parte dell'industria biomedica, che si è maggiormente focalizzata sulla realizzazione di prodotti utilizzabili da un più ampio raggio di pazienti. Per queste ragioni, l'ingegneria tissutale della cute ha trovato più ampio campo di applicazione nel sistema dei test in vitro. A tale scopo sono stati creati dei protocolli certificati per testare la corrosività, la irritabilità e la vitalità del tessuto cutaneo, quali EpiDerm, EpiSkin e SkinEthic che si avvalgono dell'uso del metodo MMT e della spettrofotometria, che è diventata un supporto fondamentale per le scienze biologiche.
Resumo:
The first part of this thesis has focused on the construction of a twelve-phase asynchronous machine for More Electric Aircraft (MEA) applications. In fact, the aerospace world has found in electrification the way to improve the efficiency, reliability and maintainability of an aircraft. This idea leads to the aircraft a new management and distribution of electrical services. In this way is possible to remove or to reduce the hydraulic, mechanical and pneumatic systems inside the aircraft. The second part of this dissertation is dedicated on the enhancement of the control range of matrix converters (MCs) operating with non-unity input power factor and, at the same time, on the reduction of the switching power losses. The analysis leads to the determination in closed form of a modulation strategy that features a control range, in terms of output voltage and input power factor, that is greater than that of the traditional strategies under the same operating conditions, and a reduction in the switching power losses.
Resumo:
Cerebral vasospasm after aneurysmal subarachnoid hemorrhage (aSAH) is a frequent but unpredictable complication associated with poor outcome. Current vasospasm therapies are suboptimal; new therapies are needed. Clazosentan, an endothelin receptor antagonist, has shown promise in phase 2 studies, and two randomized, double-blind, placebo-controlled phase 3 trials (CONSCIOUS-2 and CONSCIOUS-3) are underway to further investigate its impact on vasospasm-related outcome after aSAH. Here, we describe the design of these studies, which was challenging with respect to defining endpoints and standardizing endpoint interpretation and patient care. Main inclusion criteria are: age 18-75 years; SAH due to ruptured saccular aneurysm secured by surgical clipping (CONSCIOUS-2) or endovascular coiling (CONSCIOUS-3); substantial subarachnoid clot; and World Federation of Neurosurgical Societies grades I-IV prior to aneurysm-securing procedure. In CONSCIOUS-2, patients are randomized 2:1 to clazosentan (5 mg/h) or placebo. In CONSCIOUS-3, patients are randomized 1:1:1 to clazosentan 5, 15 mg/h, or placebo. Treatment is initiated within 56 h of aSAH and continued until 14 days after aSAH. Primary endpoint is a composite of mortality and vasospasm-related morbidity within 6 weeks of aSAH (all-cause mortality, vasospasm-related new cerebral infarction, vasospasm-related delayed ischemic neurological deficit, neurological signs or symptoms in the presence of angiographic vasospasm leading to rescue therapy initiation). Main secondary endpoint is extended Glasgow Outcome Scale at week 12. A critical events committee assesses all data centrally to ensure consistency in interpretation, and patient management guidelines are used to standardize care. Results are expected at the end of 2010 and 2011 for CONSCIOUS-2 and CONSCIOUS-3, respectively.
Resumo:
Background Several studies have shown an association of cryptogenic stroke and embolism with patent foramen ovale (PFO), but the question how to prevent further events in such patients is unresolved. Options include antithrombotic treatment with warfarin or antiplatelet agents or surgical or endovascular closure of the PFO. The PC-Trial was set up to compare endovascular closure and best medical treatment for prevention of recurrent events. Methods The PC-Trial is a randomized clinical trial comparing the efficacy of percutaneous closure of the PFO using the Amplatzer PFO occluder with best medical treatment in patients with cryptogenic embolism, i.e. mostly cryptogenic stroke. Warfarin for 6 months followed by antiplatelet agents is recommended as medical treatment. Randomization is stratified according to patients age (<45 versus ≥45 years), presence of atrial septal aneurysm (ASA yes or no) and number of embolic events before randomization (one versus more than one event). Primary endpoints are death, nonfatal stroke and peripheral embolism. Discussion patients were randomized in 29 centers of Europe, Canada, and Australia. Randomization started February 2000. Enrollment of 414 patients was completed in February 2009. All patients will be followed-up longitudinally. Follow-up is maintained until the last enrolled patient is beyond 2.5 years of follow-up (expected in 2011).
Resumo:
Compared with bare metal stents (BMS), early generation drug-eluting stents (DES) reduce the risk of revascularisation in patients with ST-elevation myocardial infarction (STEMI) at the expense of an increased risk of very late stent thrombosis (ST). Durable polymer coatings for controlled drug release have been identified as a potential trigger for these late adverse events and this has led to the development of newer generation DES with durable and biodegradable polymer surface coatings with improved biocompatibility. In a recent all-comers trial, biolimus-eluting stents with a biodegradable polymer surface coating were found to reduce the risk of very late ST by 80% compared with sirolimus-eluting stents with durable polymer, which also translated into a lower risk of cardiac death and myocardial infarction (MI) beyond one year.