994 resultados para Comparison principle
Resumo:
Standard Monte Carlo (sMC) simulation models have been widely used in AEC industry research to address system uncertainties. Although the benefits of probabilistic simulation analyses over deterministic methods are well documented, the sMC simulation technique is quite sensitive to the probability distributions of the input variables. This phenomenon becomes highly pronounced when the region of interest within the joint probability distribution (a function of the input variables) is small. In such cases, the standard Monte Carlo approach is often impractical from a computational standpoint. In this paper, a comparative analysis of standard Monte Carlo simulation to Markov Chain Monte Carlo with subset simulation (MCMC/ss) is presented. The MCMC/ss technique constitutes a more complex simulation method (relative to sMC), wherein a structured sampling algorithm is employed in place of completely randomized sampling. Consequently, gains in computational efficiency can be made. The two simulation methods are compared via theoretical case studies.
Resumo:
Purpose The repair, maintenance, minor alteration and addition (RMAA) sector has been expanding in many developed cities. Safety problems of the RMAA sector have attracted the attention of many governments. This study has the objectives of comparing the level of safety climate of workers, supervisors and managers in the RMAA sector; and explaining/ predicting the impact of safety climate on injury occurrence of workers, supervisors and managers. Design/methodology/approach A questionnaire survey was administered to RMAA contracting companies in Hong Kong. Findings When comparing the safety climate perception of workers, supervisors and managers in the RMAA sector, the supervisors group had the lowest mean safety climate score. Results showed that a positive workforce safety attitude and acceptance of safety rules and regulations reduced the workers’ likelihood of having injuries. A reasonable production schedule led to a lower probability of supervisors being injured. Management commitment and effective safety management reduced the probability of managers being injured. Originality/value This study revealed variations of safety climate at the different levels in the organizational hierarchy and their varying influence on safety performance of the RMAA sector. Safety of RMAA works could be improved by promulgating specific safety measures at the different hierarchy levels.
Resumo:
Blast mats that can be retrofitted to the floor of military vehicles are considered to reduce the risk of injury from under‐vehicle explosions. Anthropometric test devices (ATDs) are validated for use only in the seated position. The aim of this study was to use a traumatic injury simulator fitted with 3 different blast mats in order to assess the ability of 2 ATD designs to evaluate the protective capacity of the mats in 2 occupant postures under 2 severities. Tests were performed for each combination of mat design, ATD, severity and posture using an antivehicle under‐belly injury simulator. The differences between mitigation systems were larger under the H‐III compared to the MiL‐Lx. There was little difference in how the 2 ATDs and how posture ranked the mitigation systems. Results from this study suggest that conclusions obtained by testing in the seated position can be extrapolated to the standing. However, the different percentage reductions observed in the 2 ATDs suggests different levels of protection. It is therefore unclear which ATD should be used to assess such mitigation systems. A correlation between cadavers and ATDs on the protection offered by blast mats is required in order to elucidate this issue.
Resumo:
Purpose. To quantify the molecular lipid composition of patient-matched tear and meibum samples and compare tear and meibum lipid molecular profiles. Methods. Lipids were extracted from tears and meibum by bi-phasic methods using 10:3 tertbutyl methyl ether:methanol, washed with aqueous ammonium acetate, and analyzed by chipbased nanoelectrospray ionization tandem mass spectrometry. Targeted precursor ion and neutral loss scans identified individual molecular lipids and quantification was obtained by comparison to internal standards in each lipid class. Results. Two hundred and thirty-six lipid species were identified and quantified from nine lipid classes comprised of cholesterol esters, wax esters, (O-acyl)-x-hydroxy fatty acids, triacylglycerols, phosphatidylcholine, lysophosphatidylcholine, phosphatidylethanolamine, sphingomyelin, and phosphatidylserine. With the exception of phospholipids, lipid molecular profiles were strikingly similar between tears and meibum. Conclusions. Comparisons between tears and meibum indicate that meibum is likely to supply the majority of lipids in the tear film lipid layer. However, the observed higher mole ratio of phospholipid in tears shows that analysis of meibum alone does not provide a complete understanding of the tear film lipid composition.
Resumo:
Background Most studies examining determinants of rising rates of caesarean section have examined patterns in documented reasons for caesarean over time in a single location. Further insights could be gleaned from cross-cultural research that examines practice patterns in locations with disparate rates of caesarean section at a single time point. Methods We compared both rates of and main reason for pre-labour and intrapartum caesarean between England and Queensland, Australia, using data from retrospective cross-sectional surveys of women who had recently given birth in England (n = 5,250) and Queensland (n = 3,467). Results Women in Queensland were more likely to have had a caesarean birth (36.2%) than women in England (25.1% of births; OR = 1.44, 95% CI = 1.28-1.61), after adjustment for obstetric characteristics. Between-country differences were found for rates of pre-labour caesarean (21.2% vs. 12.2%) but not for intrapartum caesarean or assisted vaginal birth. Compared to women in England, women in Queensland with a history of caesarean were more likely to have had a pre-labour caesarean and more likely to have had an intrapartum caesarean, due only to a previous caesarean. Among women with no previous caesarean, Queensland women were more likely than women in England to have had a caesarean due to suspected disproportion and failure to progress in labour. Conclusions The higher rates of caesarean birth in Queensland are largely attributable to higher rates of caesarean for women with a previous caesarean, and for the main reason of having had a previous caesarean. Variation between countries may be accounted for by the absence of a single, comprehensive clinical guideline for caesarean section in Queensland. Keywords: Caesarean section; Childbirth; Pregnancy; Cross-cultural comparison; Vaginal birth after caesarean; Previous caesarean section; Patient-reported data; Quality improvement
Resumo:
Objectives: Concentrations of troponin measured with high sensitivity troponin assays are raised in a number of emergency department (ED) patients; however many are not diagnosed with acute myocardial infarction (AMI). Clinical comparisons between the early use (2 h after presentation) of high sensitivity cardiac troponin T (hs-cTnT) and I (hs-cTnI) assays for the diagnosis of AMI have not been reported. Design and methods: Early (0 h and 2 h) hs-cTnT and hs-cTnI assay results in 1571 ED patients with potential acute coronary syndrome (ACS) without ST elevation on electrocardiograph (ECG) were evaluated. The primary outcome was diagnosis of index MI adjudicated by cardiologists using the local cTnI assay results taken ≥6 h after presentation, ECGs and clinical information. Stored samples were later analysed with hs-cTnT and hs-cTnI assays. Results: The ROC analysis for AMI (204 patients; 13.0%) for hs-cTnT and hs-cTnI after 2 h was 0.95 (95% CI: 0.94–0.97) and 0.98 (95% CI: 0.97–0.99) respectively. The sensitivity, specificity, PLR, and NLR of hs-cTnT and hs-cTnI for AMI after 2 h were 94.1% (95% CI: 90.0–96.6) and 95.6% (95% CI: 91.8–97.7), 79.0% (95% CI: 76.8–81.1) and 92.5% (95% CI: 90.9–93.7), 4.48 (95% CI: 4.02–5.00) and 12.86 (95% CI: 10.51–15.31), and 0.07 (95% CI: 0.04–0.13) and 0.05 (95% CI:0.03–0.09) respectively. Conclusions: Exclusion of AMI 2 h after presentation in emergency patients with possible ACS can be achieved using hs-cTnT or hs-cTnI assays. Significant differences in specificity of these assays are relevant and if using the hs-cTnT assay, further clinical assessment in a larger proportion of patients would be required.
Accelerometer data reduction : a comparison of four reduction algorithms on select outcome variables
Resumo:
Purpose Accelerometers are recognized as a valid and objective tool to assess free-living physical activity. Despite the widespread use of accelerometers, there is no standardized way to process and summarize data from them, which limits our ability to compare results across studies. This paper a) reviews decision rules researchers have used in the past, b) compares the impact of using different decision rules on a common data set, and c) identifies issues to consider for accelerometer data reduction. Methods The methods sections of studies published in 2003 and 2004 were reviewed to determine what decision rules previous researchers have used to identify wearing period, minimal wear requirement for a valid day, spurious data, number of days used to calculate the outcome variables, and extract bouts of moderate to vigorous physical activity (MVPA). For this study, four data reduction algorithms that employ different decision rules were used to analyze the same data set. Results The review showed that among studies that reported their decision rules, much variability was observed. Overall, the analyses suggested that using different algorithms impacted several important outcome variables. The most stringent algorithm yielded significantly lower wearing time, the lowest activity counts per minute and counts per day, and fewer minutes of MVPA per day. An exploratory sensitivity analysis revealed that the most stringent inclusion criterion had an impact on sample size and wearing time, which in turn affected many outcome variables. Conclusions These findings suggest that the decision rules employed to process accelerometer data have a significant impact on important outcome variables. Until guidelines are developed, it will remain difficult to compare findings across studies
Resumo:
OBJECTIVES: To compare the classification accuracy of previously published RT3 accelerometer cut-points for youth using energy expenditure, measured via portable indirect calorimetry, as a criterion measure. DESIGN: Cross-sectional cross-validation study. METHODS: 100 children (mean age 11.2±2.8 years, 61% male) completed 12 standardized activities trials (3 sedentary, 5 lifestyle and 4 ambulatory) while wearing an RT3 accelerometer. V˙O2 was measured concurrently using the Oxycon Mobile portable calorimeter. Cut-points by Vanhelst (VH), Rowlands (RW), Chu (CH), Kavouras (KV) and the RT3 manufacturer (RT3M) were used to classify PA intensity as sedentary (SED), light (LPA), moderate (MPA) or vigorous (VPA). Classification accuracy was evaluated using the area under the Receiver Operating Characteristic curve (ROC-AUC) and weighted Kappa (κ). RESULTS: For moderate-to-vigorous PA (MVPA), VH, KV and RW exhibited excellent accuracy classification (ROC-AUC≥0.90), while the CH and RT3M exhibited good classification accuracy (ROC-AUC>0.80). Classification accuracy for LPA was fair to poor (ROC-AUC<0.76). For SED, VH exhibited excellent classification accuracy (ROC-AUC>0.90), while RW, CH, and RT3M exhibited good classification accuracy (ROC-AUC>0.80). Kappa statistics ranged from 0.67 (VH) to 0.55 (CH). CONCLUSIONS: All cut-points provided acceptable classification accuracy for SED and MVPA, but limited accuracy for LPA. On the basis of classification accuracy over all four levels of intensity, the use of the VH cut-points is recommended.
Resumo:
Finite element models of bones can be created by deriving geometry from anx-ray CT scan. Material properties such as the elastic modulus can then be applied using either a single or set of homogeneous values, or individual elements can have local values mapped onto them. Values for the elastic modulus can be derived from the CT density values using an elasticityversus density relationship. Many elasticity–density relationships have been reported in the literature for human bone. However, while ovine in vivo models are common in orthopaedic research, no work has been done to date on creating FE models of ovine bones. To create these models and apply relevant material properties, an ovine elasticity-density relationship needs to be determined. Using fresh frozen ovine tibias the apparent density of regions of interest was determined from a clinical CT scan. The bones were the sectioned into cuboid samples of cortical bone from the regions of interest. Ultrasound was used to determine the elastic modulus in each of three directions – longitudinally, radially and tangentially. Samples then underwent traditional compression testing in each direction. The relationships between apparent density and both ultrasound, and compression modulus in each directionwere determined. Ultrasound testing was found to be a highly repeatable non-destructive method of calculating the elastic modulus, particularly suited to samples of this size. The elasticity-density relationships determined in the longitudinal direction were very similar between the compression and ultrasound data over the density range examined.A clear difference was seen in the elastic modulus between the longitudinal and transverse directions of the bone samples, and a transverse elasticity-density relationship is also reported.
Resumo:
Background Accelerometers have become one of the most common methods of measuring physical activity (PA). Thus, validity of accelerometer data reduction approaches remains an important research area. Yet, few studies directly compare data reduction approaches and other PA measures in free-living samples. Objective To compare PA estimates provided by 3 accelerometer data reduction approaches, steps, and 2 self-reported estimates: Crouter's 2-regression model, Crouter's refined 2-regression model, the weighted cut-point method adopted in the National Health and Nutrition Examination Survey (NHANES; 2003-2004 and 2005-2006 cycles), steps, IPAQ, and 7-day PA recall. Methods A worksite sample (N = 87) completed online-surveys and wore ActiGraph GT1M accelerometers and pedometers (SW-200) during waking hours for 7 consecutive days. Daily time spent in sedentary, light, moderate, and vigorous intensity activity and percentage of participants meeting PA recommendations were calculated and compared. Results Crouter's 2-regression (161.8 +/- 52.3 minutes/day) and refined 2-regression (137.6 +/- 40.3 minutes/day) models provided significantly higher estimates of moderate and vigorous PA and proportions of those meeting PA recommendations (91% and 92%, respectively) as compared with the NHANES weighted cut-point method (39.5 +/- 20.2 minutes/day, 18%). Differences between other measures were also significant. Conclusions When comparing 3 accelerometer cut-point methods, steps, and self-report measures, estimates of PA participation vary substantially.
Resumo:
In this study, we evaluated agreement among three generations of ActiGraph (TM) accelerometers in children and adolescents. Twenty-nine participants (mean age = 14.2 +/- 3.0 years) completed two laboratory-based activity sessions, each lasting 60 min. During each session, participants concurrently wore three different models of the ActiGraph (TM) accelerometers (GT1M, GT3X, GT3X+). Agreement among the three models for vertical axis counts, vector magnitude counts, and time spent in moderate-to-vigorous physical exercise (MVPA) was evaluated by calculating intraclass correlation coefficients and Bland-Altman plots. The intraclass correlation coefficient for total vertical axis counts, total vector magnitude counts, and estimated MVPA was 0.994 (95% CI = 0.989-0.996), 0.981 (95% CI = 0.969-0.989), and 0.996 (95% CI = 0.989-0.998), respectively. Inter-monitor differences for total vertical axis and vector magnitude counts ranged from 0.3% to 1.5%, while inter-monitor differences for estimated MVPA were equal to or close to zero. On the basis of these findings, we conclude that there is strong agreement between the GT1M, GT3X, and GT3X+ activity monitors, thus making it acceptable for researchers and practitioners to use different ActiGraph (TM) models within a given study.
Resumo:
The absence of comparative validity studies has prevented researchers from reaching consensus regarding the application of intensity-related accelerometer cut points for children and adolescents. PURPOSE This study aimed to evaluate the classification accuracy of five sets of independently developed ActiGraph cut points using energy expenditure, measured by indirect calorimetry, as a criterion reference standard. METHODS A total of 206 participants between the ages of 5 and 15 yr completed 12 standardized activity trials. Trials consisted of sedentary activities (lying down, writing, computer game), lifestyle activities (sweeping, laundry, throw and catch, aerobics, basketball), and ambulatory activities (comfortable walk, brisk walk, brisk treadmill walk, running). During each trial, participants wore an ActiGraph GT1M, and VO 2 was measured breath-by-breath using the Oxycon Mobile portable metabolic system. Physical activity intensity was estimated using five independently developed cut points: Freedson/Trost (FT), Puyau (PU), Treuth (TR), Mattocks (MT), and Evenson (EV). Classification accuracy was evaluated via weighted κ statistics and area under the receiver operating characteristic curve (ROC-AUC). RESULTS Across all four intensity levels, the EV (κ = 0.68) and FT (κ = 0.66) cut points exhibited significantly better agreement than TR (κ = 0.62), MT (κ = 0.54), and PU (κ = 0.36). The EV and FT cut points exhibited significantly better classification accuracy for moderate-to vigorous-intensity physical activity (ROC-AUC = 0.90) than TR, PU, or MT cut points (ROC-AUC = 0.77-0.85). Only the EV cut points provided acceptable classification accuracy for all four levels of physical activity intensity and performed well among children of all ages. The widely applied sedentary cut point of 100 counts per minute exhibited excellent classification accuracy (ROC-AUC = 0.90). CONCLUSIONS On the basis of these findings, we recommend that researchers use the EV ActiGraph cut points to estimate time spent in sedentary, light-, moderate-, and vigorous-intensity activity in children and adolescents. Copyright © 2011 by the American College of Sports Medicine.
Resumo:
We construct a two-scale mathematical model for modern, high-rate LiFePO4cathodes. We attempt to validate against experimental data using two forms of the phase-field model developed recently to represent the concentration of Li+ in nano-sized LiFePO4crystals. We also compare this with the shrinking-core based model we developed previously. Validating against high-rate experimental data, in which electronic and electrolytic resistances have been reduced is an excellent test of the validity of the crystal-scale model used to represent the phase-change that may occur in LiFePO4material. We obtain poor fits with the shrinking-core based model, even with fitting based on “effective” parameter values. Surprisingly, using the more sophisticated phase-field models on the crystal-scale results in poorer fits, though a significant parameter regime could not be investigated due to numerical difficulties. Separate to the fits obtained, using phase-field based models embedded in a two-scale cathodic model results in “many-particle” effects consistent with those reported recently.
Resumo:
Objective The present study aimed to develop accelerometer cut points to classify physical activities (PA) by intensity in preschoolers and to investigate discrepancies in PA levels when applying various accelerometer cut points. Methods To calibrate the accelerometer, 18 preschoolers (5.8 +/- 0.4 years) performed eleven structured activities and one free play session while wearing a GT1M ActiGraph accelerometer using 15 s epochs. The structured activities were chosen based on the direct observation system Children's Activity Rating Scale (CARS) while the criterion measure of PA intensity during free play was provided using a second-by-second observation protocol (modified CARS). Receiver Operating Characteristic (ROC) curve analyses were used to determine the accelerometer cut points. To examine the classification differences, accelerometer data of four consecutive days from 114 preschoolers (5.5 +/- 0.3 years) were classified by intensity according to previously published and the newly developed accelerometer cut points. Differences in predicted PA levels were evaluated using repeated measures ANOVA and Chi Square test. Results Cut points were identified at 373 counts/15 s for light (sensitivity: 86%; specificity: 91%; Area under ROC curve: 0.95), 585 counts/15 s for moderate (87%; 82%; 0.91) and 881 counts/15 s for vigorous PA (88%; 91%; 0.94). Further, applying various accelerometer cut points to the same data resulted in statistically and biologically significant differences in PA. Conclusions Accelerometer cut points were developed with good discriminatory power for differentiating between PA levels in preschoolers and the choice of accelerometer cut points can result in large discrepancies.
Resumo:
Objective To compare the level of agreement in results obtained from four physical activity (PA) measurement instruments that are in use in Australia and around the world. Methods 1,280 randomly selected participants answered two sets of PA questions by telephone. 428 answered the Active Australia (AA) and National Health Surveys, 427 answered the AA and CDC Behavioural Risk Factor Surveillance System surveys (BRFSS), and 425 answered the AA survey and the short International Physical Activity Questionnaire (IPAQ). Results Among the three pairs of survey items, the difference in mean total PA time was lowest when the AA and NHS items were asked (difference=24) (SE:17) minutes, compared with 144 (SE:21) mins for AA/BRFSS and 406 (SE:27) mins for AA/IPAQ). Correspondingly, prevalence estimates for 'sufficiently active' were similar for AA and NHS (56% and 55% respectively), but about 10% higher when BRFSS data were used, and about 26% higher when the IPAQ items were used, compared with estimates from the AA survey. Conclusions The findings clearly demonstrate that there are large differences in reported PA times and hence in prevalence estimates of 'sufficient activity' from these four measures. Implications It is important to consistently use the same survey for population monitoring purposes. As the AA survey has now been used three times in national surveys, its continued use for population surveys is recommended so that trend data ever a longer period of time can be established.