938 resultados para Comparison between methods of analysis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To investigate if tests used in the preoperative period of upper abdominal or thoracic surgeries are able to differentiate the patients that presented cardiopulmonary postoperative complications. METHODS: Seventy eight patients, 30 submitted to upper abdominal surgery and 48 to thoracic surgery were evaluated. Spirometry, respirometry, manovacuometry, six-minute walk test and stair-climbing test were performed. Complications from immediate postoperative to discharge from hospital were registered. RESULTS: The postoperative complications rate was 17% in upper abdominal surgery and 10% in thoracic surgery. In the univariate regression, the only variable that kept the correlation with postoperative complications in the upper abdominal surgery was maximal expiratory pressure. In thoracic surgery, the maximal voluntary ventilation, six-minute walk test and time in stair-climbing test presented correlation with postoperative complications. After multiple regression only stair-climbing test continued as an important risk predictor in thoracic surgery. CONCLUSION: The respiratory pressure could differentiate patients with complications in upper abdominal surgery, whereas in thoracic surgery, only spirometric values and exercise tests could differentiate them.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this meta-analysis was to investigate the influence of meiotic spindle visualization in human oocytes on intracytoplasmic sperm injection (ICSI) outcomes. Search strategies included on-line Surveys of databases (MEDLINE, em BASE, Science Citation Index, Cochrane Controlled Trials Register and Ovid). The fixed effect was used for odds ratio. Ten trials fulfilled the inclusion criteria comparing in-vitro and clinical ICSI outcomes with or without visualization of meiotic spindle in fresh and in-vivo matured oocytes. According to the meta-analysis, the results showed statistically significant higher fertilization rate (P < 0.0001) when the meiotic spindle was viewed than when it was not. Moreover, the percentage of pro-nuclear-stage embyros with good morphology (P = 0.003), cleavage rate (P < 0.0001), percentage of day-3 top-quality embryos (P = 0.003) and percentage of embryos that reached the blastocyst stage (P < 0.0001) were statistically significantly better among, embryos derived from oocytes in which meiotic spindle was viewed compared with those in which meiotic spindle was not observed. However, these differences were not observed in the clinical pregnancy or implantation rates. This observation has clinical relevance mainly in countries where there is a legal limit on the number of oocytes to be fertilized. However, additional controlled trials are needed to further confirm these results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Verificar se os testes: Volume Expiratório Forçado no 1º segundo (VEF1), Teste de Caminhada de 6 minutos (TC6) e Teste de Escada (TE) se alteram proporcionalmente ao pulmão funcionante ressecado. MÉTODOS: Foram incluídos pacientes candidatos a toracotomia para ressecção pulmonar. No pré-operatório (pré) e no mínimo três meses após a cirurgia (pós), realizaram espirometria, TC6 e TE. O TE foi realizado em escada com 12,16m de altura. O tempo para subir todos os degraus o mais rápido possível foi chamado tempo de escada (tTE). Os cálculos dos valores dos testes preditos para o pós-operatório (ppo) foram realizados conforme o número de segmentos funcionantes perdidos. Os valores pré, ppo e pós foram comparados entre si para cada teste. Estatística: foi utilizada a análise de variância para medidas repetidas (ANOVA), com significância de 5%. RESULTADOS: Foram estudados 40 pacientes. A ressecção pulmonar variou desde o ganho de dois segmentos funcionantes até a perda de 9. Os valores pré, ppo e pós foram respectivamente: VEF1 -pré = 2,6±0,8L, ppo = 2,3±0,8L, pós = 2,3±0,8L (VEF1pré > VEF1ppo = VEF1pós), TC6-pré = 604±63m, ppo = 529±103m, pós = 599±74m (TC6pré = TC6pós > TC6ppo), tTE-pré = 32,9±7,6s, ppo = 37,8±12,1s, pós = 33,7±8,5s (tTEpré = tTEpós < tTEppo). CONCLUSÃO: Nas ressecções pulmonares, este grupo de pacientes perdeu função pulmonar medida através da espirometria, mas não perdeu a capacidade de exercício, medida através dos testes de escada e caminhada.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The tissue microarray (TMA) technique allows multiple tissue samples in a single block. Commercial adhesive tape is used to avoid the loss of tissue samples during the immunostaining process. Few reports exist in the literature comparing the use of these adhesive tapes to other adhesive techniques. The objective of this study was to compare loss of sections adhered to slides using commercial adhesive tapes versus using silanized only slides. TMA was constructed with varying tissues using a fixed-base device (Beecher Instruments), placing 108 cylinders of 1 mm diameter in duplicate, spaced 1.2 mm apart. Section of 4 mu m were cut from the TMA block and adhered to 30 silanized slides and 30 commercial glass slides using adhesive tape, according to manufacturer's recommendations. Vimentin immunoexpression was evaluated by immunohistochemistry. Antigenic recovery was realized in citrate buffer using a microwave oven. Cylinder loss in the immunohistochemical process was quantified and expressed as: total (>80%), almost complete (75-79%), or partial (50-74%). The commercial adhesive tape group presented lesser total loss (1.1 versus 6.4%), almost complete loss (2.2 versus 3.5%), and partial loss (2.1 versus 3.8%) than the silanized slide group (ANOVA, P < 0.05). The sum of total and almost complete losses in the silanized slide group was 9.9%, greater than the losses in slides using commercial adhesive tapes (3.3%) and less than reported and considered acceptable in the literature (10-30%). In conclusion, the use of silanized only slides presents very satisfactory results, requires less training, and reduces costs significantly, thus justifying their use in research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To compare intermittent mandatory ventilation (IMV) with synchronized intermittent mandatory ventilation plus pressure support (SIMV+PS) in terms of time on mechanical ventilation, duration of weaning and length of stay in a pediatric intensive care unit (PICU).Methods: This was a randomized clinical trial that enrolled children aged 28 days to 4 years who were admitted to a PICU between October of 2005 and June of 2007 and put on mechanical ventilation (MV) for more than 48 hours. These patients were allocated to one of two groups by drawing lots: IMV group (IMVG; n = 35) and SIMV+PS group (SIMVG; n = 35). Children were excluded if they had undergone tracheotomy or had chronic respiratory diseases. Data on oxygenation and ventilation were recorded at admission and at the start of weaning.Results: There were no statistical differences between the groups in terms of age, sex, indication for MV, PRISM score, Comfort scale, use of sedatives or ventilation and oxygenation parameters. The median time on MV was 5 days for both groups (p = 0.120). There were also no statistical differences between the two groups for duration of weaning [IMVG: 1 day (1-6) vs. SIMVG: 1 day (1-6); p = 0.262] or length of hospital stay [IMVG: 8 days (2-22) vs. SIMVG: 6 days (3-20); p = 0.113].Conclusion: Among the children studied here, there was no statistically significant difference between IMV and SIMV+ PS in terms of time on MV, duration of weaning or time spent in the PICU.ClinicalTrials.govID: NCT00549809.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two series of alkanediyl-a,w-bis (dimethylalkylammonium bromide (n-2-n and n-6-n; n=8, 10,12, and 16) have been synthesized and their micelles properties studied in aqueous solution using pyrene, pyrenecarboxaldehyde (PCA) and 1,8 anilinonaphtalene sulfonic acid sodium salt (ANS) as fluorescent probes. The micelles from these surfactants have been characterized on the basis of the information provided by micelle-solubilized fluorescent probes. The obtained results indicated that the surfactant concentration at which a marked decrease in l max parameter of pyrenecarboxaldehyde (PCA) occurs corresponds to the CMC determined by conductimetric measurements. Changes in the emission spectra of ANS and PCA observed in the submicellar range for both surfactants series (n-2-n and n-6-n) were interpreted as formation of pre-aggregates. It was found that the dimeric surfactants with long spacer (s= 6) form more hydrated aggregates when compared with those formed by the n-2-n and CnTAB surfactants series. This was attributed to a more difficult packing of n-6-n surfactant molecules to form micelles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work we compared the estimates of the parameters of ARCH models using a complete Bayesian method and an empirical Bayesian method in which we adopted a non-informative prior distribution and informative prior distribution, respectively. We also considered a reparameterization of those models in order to map the space of the parameters into real space. This procedure permits choosing prior normal distributions for the transformed parameters. The posterior summaries were obtained using Monte Carlo Markov chain methods (MCMC). The methodology was evaluated by considering the Telebras series from the Brazilian financial market. The results show that the two methods are able to adjust ARCH models with different numbers of parameters. The empirical Bayesian method provided a more parsimonious model to the data and better adjustment than the complete Bayesian method.