943 resultados para COHERENCE TOMOGRAPHY


Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCCIÓN: El Edema Macular (EM) es la principal causa de perdida de agudeza visual en pacientes con Oclusión Venosa Retiniana (OVR); luego del tratamiento, algunos pacientes persisten con mala agudeza visual. OBJETIVO: Realizar una Revisión Sistemática de la Literatura (RSL), para identificar la evidencia existente sobre factores tomográficos que predicen el resultado visual en pacientes con EM secundario a OVR. FUENTE DE LA INFORMACIÓN: PUBMED, MEDLINE, EMBASE, LILACS, COCHRANE, literatura gris. SELECCIÓN DE LOS ESTUDIOS: Ensayos Clínicos Controlados (ECC) y estudios observacionales analíticos. EXTRACCIÓN Y SÍNTESIS DE LOS DATOS: Dos investigadores seleccionaron los artículos de forma independiente. Se realizó una síntesis cualitativa de la información siguiendo las recomendaciones de la declaración PRISMA 2009. MEDIDAS Y DESENLACE PRINCIPAL: Grosor Retiniano Central (GRC), integridad de Banda Elipsoide e Integridad de Membrana Limitante Externa (MLE), determinados por SD OCT. El desenlace principal es la Agudeza Visual Mejor Corregida (AVMC) a los 6, 12,18 y/o 24 meses. RESULTADOS: Se identificaron 872 abstract y se incluyeron 8 artículos en el análisis cualitativo. Seis estudios evaluaron el GRC sin encontrar asociación con resultado visual final. Solo 2 estudios evaluaron y encontraron asociación estadísticamente significativa de la integridad de la MLE con el desenlace visual, Kang, H 2012 (r2 0,51 p 0,000), Rodriguez, F 2014 (p< 0,001). La integridad de la BE fue asociada a pronostico visual en 4 de 5 estudios que evaluaron esta variable, con resultados estadísticamente significativos. La AVMC de base también se asocio con desenlace visual en 4 de 5 estudios que la evaluaron. El mejor modelo que predice el resultado funcional según el estudio de Kang, H 2012 fue: Integridad de MLE, integridad de BE y AVMC de base (R2 0,671 p 0,000), a los 12 meses de seguimiento. CONCLUSION: La evidencia actual sugiere que la integridad de la BE y la MLE son predictores del resultados funcional en pacientes con EM secundario a OVR después de 6 o mas meses de seguimiento. Es necesario la realización de estudios controlados para llegar a resultados mas concluyentes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim The aim of my Ph.D. was to implement a diffusion tensor tractography (DTT) pipeline to reconstruct cranial nerve I (olfactory) to study COVID-19 patients, and anterior optic pathway (AOP, including optic nerve, chiasm, and optic tract) to study patients with sellar/parasellar tumors, and with Leber’s Hereditary Optic Neuropathy (LHON). Methods We recruited 23 patients with olfactory dysfunction after COVID-19 infection (mean age 37±14 years, 12 females); 27 patients with sellar/parasellar tumors displacing the optic chiasm eligible for endonasal endoscopic surgery (mean age 53. ±16.4 years, 13 female) and 6 LHON patients (mutation 11778/MT-ND4, mean age 24.9±15.7 years). Sex- and age-matched healthy control were also recruited. In LHON patients, optical coherence tomography (OCT) was performed. Acquisitions were performed on a clinical high field 3-T MRI scanner, using a multi-shell HARDI (High Angular Resolution Diffusion Imaging) sequence (b-values 0-300-1000-2000 s/mm2, 64 maximum gradient directions, 2mm3 isotropic voxel). DTT was performed with a multi-tissue spherical deconvolution approach and mean diffusivity (MD) DTT metrics were compared with healthy controls using an unpaired t-test. Correlations of DTT metrics with clinical data were sought by regression analysis. Results In all 23 hypo/anosmic patients with previous COVID-19 infection the CN I was successfully reconstructed with no DTT metrics alterations, thus suggesting the pathogenetic role of central olfactory cortical system dysfunction. In all 27 patients with sellar/parasellar tumors the AOP was reconstructed, and in 11/13 (84.7%) undergoing endonasal endoscopic surgery the anatomical fidelity of the reconstruction was confirmed; a significant decrease in MD within the chiasma (p<0.0001) was also found. In LHON patients a reduction of MD in the AOP was significantly associated with OCT parameters (p=0.036). Conclusions Multi-shell HARDI diffusion-weighted MRI followed by multi-tissue spherical deconvolution for the DTT reconstruction of the CN I and AOP has been implemented, and its utility demonstrated in clinical practice.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: To investigate the use of intravascular optical coherence tomography (IVOCT) for carotid artery stenting (CAS) procedures in patients with atherosclerotic stenosis. Examine possible markers that might identify the onset of new cerebral ischemic lesions on MRI. Specifically, attention was drawn to the morphological features of the used dual layer stent, which could be underestimated during traditional CAS procedures. Secondary goals are to compare the safety and efficacy of different CAS techniques and the accuracy of the vessel analysis software’s on pre-operative CTA examination used to quantify ICA stenosis with the gold standard IVOCT. Material and Methods: Ten patients underwent CAS procedure with flow-arrest technique and IVOCT evaluations prior to and following stent deployment, while five matched patients underwent CAS procedure with distal embolic protection device (EPD) technique. All patients underwent 24-hours 3T MRI examination to check for ischemic lesions; all patients were treated with the same dual-layer stent. Results: Patients with new ischemic lesions demonstrated peculiar stent configuration in the distal end, and a strong Spearman’s rank order correlation was found among the volume of new DWI lesions and the stent configuration in its distal end (Rs: 0.81; p <0.001). No statistically significant differences were observed in the total burden of new ischemic lesions for each technique. The vessel analysis software's on CTA comparison demonstrated a higher diagnostic accuracy in the degree of ICA stenosis compared to the gold standard of IVOCT of the specialized software (ROC curve = 0.63; p = 0.06) compared to the general software (ROC curve = 0.57, p = 0.31). Conclusions: Study’s results support the use of IVOCT to allow recognition of potential features that can predict the onset of new cerebral ischemic lesions. Additionally, IVOCT made it possible to evaluate specialized software's increased accuracy in the pre-operative evaluation of ICA atherosclerotic stenosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To evaluate the severity of airway pathologies, quantitative dimensioning of airways is of utmost importance. Endoscopic vision gives a projective image and thus no true scaling information can be directly deduced from it. In this article, an approach based on an interferometric setup, a low-coherence laser source and a standard rigid endoscope is presented, and applied to hollow samples measurements. More generally, the use of the low-coherence interferometric setup detailed here could be extended to any other endoscopy-related field of interest, e.g., gastroscopy, arthroscopy and other medical or industrial applications where tri-dimensional topology is required. The setup design with a multiple fibers illumination system is presented. Demonstration of the method ability to operate on biological samples is assessed through measurements on ex vivo pig bronchi.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article reports a relaxation study in an oriented system containing spin 3/2 nuclei using quantum state tomography (QST). The use of QST allowed evaluating the time evolution of all density matrix elements starting from several initial states. Using an appropriated treatment based on the Redfield theory, the relaxation rate of each density matrix element was measured and the reduced spectral densities that describe the system relaxation were determined. All the experimental data could be well described assuming pure quadrupolar relaxation and reduced spectral densities corresponding to a superposition of slow and fast motions. The data were also analyzed in the context of Quantum Information Processing, where the coherence loss of each qubit of the system was determined using the partial trace operation. (C) 2008 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Brain electric mechanisms of temporary, functional binding between brain regions are studied using computation of scalp EEG coherence and phase locking, sensitive to time differences of few milliseconds. However, such results if computed from scalp data are ambiguous since electric sources are spatially oriented. Non-ambiguous results can be obtained using calculated time series of strength of intracerebral model sources. This is illustrated applying LORETA modeling to EEG during resting and meditation. During meditation, time series of LORETA model sources revealed a tendency to decreased left-right intracerebral coherence in the delta band, and to increased anterior-posterior intracerebral coherence in the theta band. An alternate conceptualization of functional binding is based on the observation that brain electric activity is discontinuous, i.e., that it occurs in chunks of up to about 100 ms duration that are detectable as quasi-stable scalp field configurations of brain electric activity, called microstates. Their functional significance is illustrated in spontaneous and event-related paradigms, where microstates associated with imagery- versus abstract-type mentation, or while reading positive versus negative emotion words showed clearly different regions of cortical activation in LORETA tomography. These data support the concept that complete brain functions of higher order such as a momentary thought might be incorporated in temporal chunks of processing in the range of tens to about 100 ms as quasi-stable brain states; during these time windows, subprocesses would be accepted as members of the ongoing chunk of processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article aimed at comparing the accuracy of linear measurement tools of different commercial software packages. Eight fully edentulous dry mandibles were selected for this study. Incisor, canine, premolar, first molar and second molar regions were selected. Cone beam computed tomography (CBCT) images were obtained with i-CAT Next Generation. Linear bone measurements were performed by one observer on the cross-sectional images using three different software packages: XoranCat®, OnDemand3D® and KDIS3D®, all able to assess DICOM images. In addition, 25% of the sample was reevaluated for the purpose of reproducibility. The mandibles were sectioned to obtain the gold standard for each region. Intraclass coefficients (ICC) were calculated to examine the agreement between the two periods of evaluation; the one-way analysis of variance performed with the post-hoc Dunnett test was used to compare each of the software-derived measurements with the gold standard. The ICC values were excellent for all software packages. The least difference between the software-derived measurements and the gold standard was obtained with the OnDemand3D and KDIS3D (-0.11 and -0.14 mm, respectively), and the greatest, with the XoranCAT (+0.25 mm). However, there was no statistical significant difference between the measurements obtained with the different software packages and the gold standard (p> 0.05). In conclusion, linear bone measurements were not influenced by the software package used to reconstruct the image from CBCT DICOM data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of technological routes to convert lignocellulosic biomass to liquid fuels requires an in-depth understanding of the cell wall architecture of substrates. Essential pretreatment processes are conducted to reduce biomass recalcitrance and usually increase the reactive surface area. Quantitative three-dimensional information about both bulk and surface structural features of substrates needs to be obtained to expand our knowledge of substrates. In this work, phase-contrast tomography (PCT) was used to gather information about the structure of a model lignocellulosic biomass (piassava fibers). The three-dimensional cellular organization of piassava fibers was characterized by PCT using synchrotron radiation. This technique enabled important physical features that describe the substrate piassava fibers to be visualized and quantified. The external surface area of a fiber and internal surface area of the pores in a fiber could be determined separately. More than 96% of the overall surface area available to enzymes was in the bulk substrate. The pore surface area and length exhibited a positive linear relationship, where the slope of this relationship depended on the plant tissue. We demonstrated that PCT is a powerful tool for the three-dimensional characterization of the cell wall features related to biomass recalcitrance. Original and relevant quantitative information about the structural features of the analyzed material were obtained. The data obtained by PCT can be used to improve processing routes to efficiently convert biomass feedstock into sugars.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chest radiography (CXR) is inferior to Thin-section computed tomography in the detection of asbestos related interstitial and pleural abnormalities. It remains unclear, however, whether these limitations are large enough to impair CXR´s ability in detecting the expected reduction in the frequency of these asbestos-related abnormalities (ARA) as exposure decreases. Clinical evaluation, CXR, Thin-section CT and spirometry were obtained in 1418 miners and millers who were exposed to progressively lower airborne concentrations of asbestos. They were separated into four groups according to the type, period and measurements of exposure and/or procedures for controlling exposure: Group I (1940-1966/tremolite and chrysotile, without measurements of exposure and procedures for controlling exposure); Group II (1967-1976/chrysotile only, without measurements of exposure and procedures for controlling exposure); Group III (1977-1980/chrysotile only, initiated measurements of exposure and procedures for controlling exposure) and Group IV (after 1981/chrysotile only, implemented measurements of exposure and a comprehensive procedures for controlling exposure). In all groups, CXR suggested more frequently interstitial abnormalities and less frequently pleural plaques than observed on Thin-section CT (p<0.050). The odds for asbestosis in groups of decreasing exposure diminished to greater extent at Thin-section CT than on CXR. Lung function was reduced in subjects who had pleural plaques evident only on Thin-section CT (p<0.050). In a longitudinal evaluation of 301 subjects without interstitial and pleural abnormalities on CXR and Thin-section CT in a previous evaluation, only Thin-section CT indicated that these ARA reduced as exposure decreased. CXR compared to Thin-section CT was associated with false-positives for interstitial abnormalities and false-negatives for pleural plaques, regardless of the intensity of asbestos exposure. Also, CXR led to a substantial misinformation of the effects of the progressively lower asbestos concentrations in the occurrence of asbestos-related diseases in miners and millers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the sensitivity and specificity of machine learning classifiers (MLCs) for glaucoma diagnosis using Spectral Domain OCT (SD-OCT) and standard automated perimetry (SAP). METHODS: Observational cross-sectional study. Sixty two glaucoma patients and 48 healthy individuals were included. All patients underwent a complete ophthalmologic examination, achromatic standard automated perimetry (SAP) and retinal nerve fiber layer (RNFL) imaging with SD-OCT (Cirrus HD-OCT; Carl Zeiss Meditec Inc., Dublin, California). Receiver operating characteristic (ROC) curves were obtained for all SD-OCT parameters and global indices of SAP. Subsequently, the following MLCs were tested using parameters from the SD-OCT and SAP: Bagging (BAG), Naive-Bayes (NB), Multilayer Perceptron (MLP), Radial Basis Function (RBF), Random Forest (RAN), Ensemble Selection (ENS), Classification Tree (CTREE), Ada Boost M1(ADA),Support Vector Machine Linear (SVML) and Support Vector Machine Gaussian (SVMG). Areas under the receiver operating characteristic curves (aROC) obtained for isolated SAP and OCT parameters were compared with MLCs using OCT+SAP data. RESULTS: Combining OCT and SAP data, MLCs' aROCs varied from 0.777(CTREE) to 0.946 (RAN).The best OCT+SAP aROC obtained with RAN (0.946) was significantly larger the best single OCT parameter (p<0.05), but was not significantly different from the aROC obtained with the best single SAP parameter (p=0.19). CONCLUSION: Machine learning classifiers trained on OCT and SAP data can successfully discriminate between healthy and glaucomatous eyes. The combination of OCT and SAP measurements improved the diagnostic accuracy compared with OCT data alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of the success of endodontic treatment has been often discussed based on outcome obtained by periapical radiography. The aim of this study was to verify the influence of intracanal post on apical periodontitis detected by cone-beam computed tomography (CBCT). A consecutive sample of 1020 images (periapical radiographs and CBCT scans) taken from 619 patients (245 men; mean age, 50.1 years) between February 2008 and September 2009 were used in this study. Presence and intracanal post length (short, medium and long) were associated with apical periodontitis (AP). Chi-square test was used for statistical analyses. Significance level was set at p<0.01. The kappa value was used to assess examiner variability. From a total of 591 intracanal posts, AP was observed in 15.06%, 18.78% and 7.95% using periapical radiographs, into the different lengths, short, medium and long, respectively (p=0.466). Considering the same posts length it was verified AP in 24.20%, 26.40% and 11.84% observed by CBCT scans, respectively (p=0.154). From a total of 1,020 teeth used in this study, AP was detected in 397 (38.92%) by periapical radiography and in 614 (60.19%) by CBCT scans (p<0.001). The distribution of intracanal posts in different dental groups showed higher prevalence in maxillary anterior teeth (54.79%). Intracanal posts lengths did not influenced AP. AP was detected more frequently when CBCT method was used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes and discusses a method to determine root curvature radius by using cone-beam computed tomography (CBCT). The severity of root canal curvature is essential to select instrument and instrumentation technique. The diagnosis and planning of root canal treatment have traditionally been made based on periapical radiography. However, the higher accuracy of CBCT images to identify anatomic and pathologic alterations compared to panoramic and periapical radiographs has been shown to reduce the incidence of false-negative results. In high-resolution images, the measurement of root curvature radius can be obtained by circumcenter. Based on 3 mathematical points determined with the working tools of Planimp® software, it is possible to calculate root curvature radius in both apical and coronal directions. The CBCT-aided method for determination of root curvature radius presented in this article is easy to perform, reproducible and allows a more reliable and predictable endodontic planning, which reflects directly on a more efficacious preparation of curved root canals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional radiography has shown limitation in acquiring image of the ATM region, thus, computed tomography (CT) scanning has been the best option to the present date for diagnosis, surgical planning and treatment of bone lesions, owing to its specific properties. OBJECTIVE: The aim of the study was to evaluate images of simulated bone lesions at the head of the mandible by multislice CT. MATERIAL AND METHODS: Spherical lesions were made with dental spherical drills (sizes 1, 3, and 6) and were evaluated by using multislice CT (64 rows), by two observers in two different occasions, deploying two protocols: axial, coronal, and sagittal images, and parasagittal images for pole visualization (anterior, lateral, posterior, medial and superior). Acquired images were then compared with those lesions in the dry mandible (gold standard) to evaluate the specificity and sensibility of both protocols. Statistical methods included: Kappa statistics, validity test and chi-square test. Results demonstrated the advantage of associating axial, coronal, and sagittal slices with parasagittal slices for lesion detection at the head of the mandible. RESULTS: There was no statistically significant difference between the types of protocols regarding a particular localization of lesions at the poles. CONCLUSIONS: Protocols for the assessment of the head of the mandible were established to improve the visualization of alterations of each of the poles of the mandible's head. The anterior and posterior poles were better visualized in lateral-medial planes while lateral, medial and superior poles were better visualized in the anterior-posterior plane.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are many studies that compare the accuracy of multislice (MSCT) and cone beam (CBCT) computed tomography for evaluations in the maxillofacial region. However, further studies comparing both acquisition techniques for the evaluation of simulated mandibular bone lesions are needed. The aim of this study was to compare the accuracy of MSCT and CBCT in the diagnosis of simulated mandibular bone lesions by means of cross sectional images and axial/MPR slices. Lesions with different dimensions, shape and locularity were produced in 15 dry mandibles. The images were obtained following the cross sectional and axial/MPR (Multiplanar Reconstruction) imaging protocols and were interpreted independently. CBCT and MSCT showed similar results in depicting the percentage of cortical bone involvement, with great sensitivity and specificity (p < 0.005). There were no significant intra- or inter-examiner differences between axial/MPR images and cross sectional images with regard to sensitivity and specificity. CBCT showed results similar to those of MSCT for the identification of the number of simulated bone lesions. Cross sectional slices and axial/MPR images presented high accuracy, proving useful for bone lesion diagnosis.