908 resultados para Building Environmental Assessment
Resumo:
Until recently, there has been little investigation concerning the poor indoor air quality (IAQ) in classrooms. Despite the evidence that the educational building systems in many of the UK institutions have significant defects that may degrade IAQ, systematic assessments of IAQ measurements has been rarely undertaken. When undertaking IAQ measurement, there is a difficult task of representing and characterizing the environment parameters. Although technologies exist to measure these parameters, direct measurements especially in a naturally ventilated spaces are often difficult. This paper presents a methodology for developing a method to characterize indoor environment flow parameters as well as the Carbon Dioxide (CO2) concentrations. Thus, CO2 concentration level can be influenced by the differences in the selection of sampling points and heights. However, because this research focuses on natural ventilation in classrooms, air exchange is provided mainly by air infiltration. It is hoped that the methodology developed and evaluated in this research can effectively simplify the process of estimating the parameters for a systematic assessment of IAQ measurements in a naturally ventilated classrooms.
Resumo:
This paper identifies the indicators of energy efficiency assessment in residential building in China through a wide literature review. Indicators are derived from three main sources: 1) The existing building assessment methods; 2)The existing Chinese standards and technology codes in building energy efficiency; 3)Academia research. As a result, we proposed an indicator list by refining the indicators in the above sources. Identified indicators are weighted by the group analytic hierarchy process (AHP) method. Group AHP method is implemented following key steps: Step 1: Experienced experts are selected to form a group; Step 2: A survey is implemented to collect the individual judgments on the importance of indicators in the group; Step 3: Members’ judgments are synthesized to the group judgments; Step 4: Indicators are weighted by AHP on the group judgments; Step 5: Investigation of consistency estimation shows that the consistency of the judgment matrix is accepted. We believe that the weighted indicators in this paper will provide important references to building energy efficiency assessment.
Resumo:
Hourly data (1994–2009) of surface ozone concentrations at eight monitoring sites have been investigated to assess target level and long–term objective exceedances and their trends. The European Union (EU) ozone target value for human health (60 ppb–maximum daily 8–hour running mean) has been exceeded for a number of years for almost all sites but never exceeded the set limit of 25 exceedances in one year. Second highest annual hourly and 4th highest annual 8–hourly mean ozone concentrations have shown a statistically significant negative trend for in–land sites of Cork–Glashaboy, Monaghan and Lough Navar and no significant trend for the Mace Head site. Peak afternoon ozone concentrations averaged over a three year period from 2007 to 2009 have been found to be lower than corresponding values over a three–year period from 1996 to 1998 for two sites: Cork–Glashaboy and Lough Navar sites. The EU long–term objective value of AOT40 (Accumulated Ozone Exposure over a threshold of 40 ppb) for protection of vegetation (3 ppm–hour, calculated from May to July) has been exceeded, on an individual year basis, for two sites: Mace Head and Valentia. The critical level for the protection of forest (10 ppm–hour from April to September) has not been exceeded for any site except at Valentia in the year 2003. AOT40–Vegetation shows a significant negative trend for a 3–year running average at Cork–Glashaboy (–0.13±0.02 ppm–hour per year), at Lough Navar (–0.05±0.02 ppm–hour per year) and at Monaghan (–0.03±0.03 ppm–hour per year–not statistically significant) sites. No statistically significant trend was observed for the coastal site of Mace head. Overall, with the exception of the Mace Head and Monaghan sites, ozone measurement records at Irish sites show a downward negative trend in peak values that affect human health and vegetation.
Resumo:
The present food shortages in the Horn of Africa and the West African Sahel are affecting 31 million people. Such continuing and future crises require that people in the region adapt to an increasing and potentially irreversible global sustainability challenge. Given this situation and that short-term weather and seasonal climate forecasting have limited skill for West Africa, the Rainwatch project illustrates the value of near real-time monitoring and improved communication for the unfavourable 2011 West African monsoon, the resulting severe drought-induced humanitarian impacts continuing into 2012, and their exacerbation by flooding in 2012. Rainwatch is now coupled with a boundary organization (Africa Climate Exchange, AfClix) with the aim of integrating the expertise and actions of relevant institutions, agencies and stakeholders to broker ground-based dialogue to promote resilience in the face of recurring crisis.
Resumo:
The sustainable intelligent building is a building that has the best combination of environmental, social, economic and technical values. And its sustainability assessment is related with system engineering methods and multi-criteria decision-making. Therefore firstly, the wireless monitoring system of sustainable parameters for intelligent buildings is achieved; secondly, the indicators and key issues based on the “whole life circle” for sustainability of intelligent buildings are researched; thirdly, the sustainable assessment model identified on the structure entropy and fuzzy analytic hierarchy process is proposed.
Resumo:
It is necessary to minimize the environmental impact and utilize natural resources in a sustainable and efficient manner in the early design stage of developing an environmentally-conscious design for a heating, ventilating and air-conditioning system. Energy supply options play a significant role in the total environmental load of heating, ventilating and air-conditioning systems. To assess the environmental impact of different energy options, a new method based on Emergy Analysis is proposed. Emergy Accounting, was first developed and widely used in the area of ecological engineering, but this is the first time it has been used in building service engineering. The environmental impacts due to the energy options are divided into four categories under the Emergy Framework: the depletion of natural resources, the greenhouse effect (carbon dioxide equivalents), the chemical rain effect (sulphur dioxide equivalents), and anthropogenic heat release. The depletion of non-renewable natural resources is indicated by the Environmental Load Ratio, and the environmental carrying capacity is developed to represent the environmental service to dilute the pollutants and anthropogenic heat released. This Emergy evaluation method provides a new way to integrate different environmental impacts under the same framework and thus facilitates better system choices. A case study of six different kinds of energy options consisting of renewable and non-renewable energy was performed by using Emergy Theory, and thus their relative environmental impacts were compared. The results show that the method of electricity generation in energy sources, especially for electricity-powered systems, is the most important factor to determine their overall environmental performance. The direct-fired lithium-bromide absorption type consumes more non-renewable energy, and contributes more to the urban heat island effect compared with other options having the same electricity supply. Using Emergy Analysis, designers and clients can make better-informed, environmentally-conscious selections of heating, ventilating and air-conditioning systems.
Resumo:
The regimen of environmental flows (EF) must be included as terms of environmental demand in the management of water resources. Even though there are numerous methods for the computation of EF, the criteria applied at different steps in the calculation process are quite subjective whereas the results are fixed values that must be meet by water planners. This study presents a friendly-user tool for the assessment of the probability of compliance of a certain EF scenario with the natural regimen in a semiarid area in southern Spain. 250 replications of a 25-yr period of different hydrological variables (rainfall, minimum and maximum flows, ...) were obtained at the study site from the combination of Monte Carlo technique and local hydrological relationships. Several assumptions are made such as the independence of annual rainfall from year to year and the variability of occurrence of the meteorological agents, mainly precipitation as the main source of uncertainty. Inputs to the tool are easily selected from a first menu and comprise measured rainfall data, EF values and the hydrological relationships for at least a 20-yr period. The outputs are the probabilities of compliance of the different components of the EF for the study period. From this, local optimization can be applied to establish EF components with a certain level of compliance in the study period. Different options for graphic output and analysis of results are included in terms of graphs and tables in several formats. This methodology turned out to be a useful tool for the implementation of an uncertainty analysis within the scope of environmental flows in water management and allowed the simulation of the impacts of several water resource development scenarios in the study site.
Resumo:
Noise mapping has been used as an instrument for assessment of environmental noise, helping to support decision making on urban planning. In Brazil, urban noise is not yet recognized as a major environmental problem by the government. Besides, cities that have databases to drive acoustic simulations, making use of advanced noise mapping systems, are rare. This study sought an alternative method of noise mapping through the use of geoprocessing, which is feasible for the Brazilian reality and for other developing countries. The area chosen for the study was the central zone of the city of Sorocaba, located in So Paulo State, Brazil. The proposed method was effective in the spatial evaluation of equivalent sound pressure level. The results showed an urban area with high noise levels that exceed the legal standard, posing a threat to the welfare of the population.
Resumo:
Brazilian environmental impact assessment (EIA) had a relatively late birth and is still far from being operative by international standards. Currently, geological, economic, and social considerations are more highly valued. Nevertheless, EIA has become important in shaping governmental environmental policy. The state of São Paulo is responsible for 40% of all EIAs produced in Brazil, and the number of EIAs produced is proportional to state population density.
Resumo:
Includes bibliography
Resumo:
Includes bibliography
Resumo:
Includes bibliography