990 resultados para Body suport device


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several boson subsystems may be involved in electrosorption phenomena. To accommodate this possibility, the one-boson formalism described in Parts I–III is extended to this case. The hierarchy in the superoperator scheme, the evaluation of operator averages for closure and several special cases are indicated. As an illustration, some calculations are presented to indicate the trends of many-body corrections in chemisorption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A blunt-nosed hypersonic missile mounted with a forward-facing cavity is a good alternative to reduce the stagnation heating rates. The effects of a forward-racing cavity on heat transfer and aerodynamic coefficients are addressed in this paper. Tests were carried out in hypersonic shock tunnel HST2, at a hypersonic Mach number of 8 using a 41 deg apex-angle blunt cone. The aerodynamic forces on the test model with and without a forward-facing cavity at various angles of attack are measured by using an internally mountable accelerometer force balance system. Heat flux measurements have been carried out on the test model with and without a forward-facing cavity of the entire surface at zero degree angle of attack with platinum sensors. A numerical simulation was also carried out using the computational fluid dynamics code (CFX-Ansys 5.7). An important result of this study is that the smaller cavity diameter has the highest lift-to-drag ratio, whereas the medium cavity has the highest heat flux reduction. Theshock structure around the test model has also been visualized using the Schlieren flow visualization technique. The visualized shock structure and the measured aerodynamic forces on the missile-shaped body with cavity configurations agree well with the axisymmetric numerical simulations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose A retrospective planning study comparing volumetric arc therapy (VMAT) and stereotactic body radiotherapy (SBRT) treatment plans for non-small cell lung cancer (NSCLC). Methods and materials Five randomly selected early stage lung cancer patients were included in the study. For each patient, four plans were created: the SBRT plan and three VMAT plans using different optimisation methodologies. A total of 20 different plans were evaluated. The dose parameters of dose conformity results and the target dose constraints results were compared for these plans. Results The mean planning target volume (PTV) for all the plans (SBRT and VMAT) was 18·3 cm3, with a range from 15·6 to 20·1 cm3. The maximum dose tolerance to 1 cc of all the plans was within 140% (84 Gy) of the prescribed dose, and 95% of the PTV of all the plans received 100% of the prescribed dose (60 Gy). In all the plans, 99% of the PTV received a dose >90% of the prescribed dose, and the mean dose in all the plans ranged from 67 to 72 Gy. The planning target dose conformity for the SBRT and the VMAT (0°, 15° collimator single arc plans and dual arc) plans showed the tightness of the prescription isodose conformity to the target. Conclusions SBRT and VMAT are radiotherapy approaches that increase doses to small tumour targets without increasing doses to the organs at risk. Although VMAT offers an alternative to SBRT for NSCLC and the potential advantage of VMAT is the reduced treatment times over SBRT, the statistical results show that there was no significant difference between the SBRT and VMAT optimised plans in terms of dose conformity and organ-at-risk sparing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We discuss micro ring resonator based optical logic gates using Kerr-type nonlinearity. Resonant wavelength selectivity is one key factor in achieving the desired gate. Based on basic gates like AND gate, OR gate etc. We proceed to propose a 3-bit binary adder circuit.Due to the presence of more than a single wavelength, the system gets complicated as we increase the number of components in the circuit. Hence it has been observed that for efficient designing and functioning of digital circuits in optical domain, we need a device which can give single wavelength output, filtering out all other wavelengths and at the same time preserve the digital characteristics of the output. We propose such filter-preserver device based on micro ring resonator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of head-mounted displays (HMDs) can produce both positive and negative experiences. In an effort increase positive experiences and avoid negative ones, researchers have identified a number of variables that may cause sickness and eyestrain, although the exact nature of the relationship to HMDs may vary, depending on the tasks and the environments. Other non-sickness-related aspects of HMDs, such as users opinions and future decisions associated with task enjoyment and interest, have attracted little attention in the research community. In this thesis, user experiences associated with the use of monocular and bi-ocular HMDs were studied. These include eyestrain and sickness caused by current HMDs, the advantages and disadvantages of adjustable HMDs, HMDs as accessories for small multimedia devices, and the impact of individual characteristics and evaluated experiences on reported outcomes and opinions. The results indicate that today s commercial HMDs do not induce serious sickness or eyestrain. Reported adverse symptoms have some influence on HMD-related opinions, but the nature of the impact depends on the tasks and the devices used. As an accessory to handheld devices and as a personal viewing device, HMDs may increase use duration and enable users to perform tasks not suitable for small screens. Well-designed and functional, adjustable HMDs, especially monocular HMDs, increase viewing comfort and usability, which in turn may have a positive effect on product-related satisfaction. The role of individual characteristics in understanding HMD-related experiences has not changed significantly. Explaining other HMD-related experiences, especially forward-looking interests, also requires understanding more stable individual traits and motivations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To monitor the seasonal body composition alterations in 18 lightweight rowers (six females, 12 males) across a rowing season incorporating preseason, early competition, competition, and postseason. METHODS Subject age was 23.1 (SD 4.5) years, height 170.8 (5.6) cm (female, 23.5 (3.5) years, 180.5 (2.7) cm (male). Body weight, fat mass, and fat-free mass (FFM) were assessed using dual energy x ray absorptiometry (DXA-L Lunar) and skinfold techniques. Weight control techniques were documented before major regattas by a questionnaire. RESULTS Female body weight was reduced from 61.3 (2.9) to 57.0 (1.1) kg (5.9%), while male body weight was reduced from 75.6 (3.1) to 69.8 (1.6) kg (7.8%) preseason to competition season respectively. These body weight reductions were mirrored by a significant reduction in fat mass as indicated by the sum of skinfolds [female seven sites: 80.9 (8.1) to 68.2 (11.8) mm; male eight sites: 54.2 (8.7) to 41.8 (4.8) mm], percentage body fat [female 22.1 (1.0) to 19.7 (2.4)%; male 10.0 (0.9) to 7.8 (0.8)%], and total fat [female 12.5 (5.2) to 10.9 (1.4) kg; male 7.3 (1.9) to 5.6 (1.8) kg] (DXA). In contrast, no changes were observed in FFM despite a season of intensive rowing training. Seasonal body weight control was achieved through reduced total energy and dietary fat intakes. Acute body weight reductions were achieved by exercise in 73.3% of participants, food restriction in 71.4%, and fluid restrictions in 62.9%. CONCLUSIONS Seasonal body weight alterations in lightweight rowers are in response to a significant reduction in fat mass. However, the weight restrictions appear to be limiting an increase in FFM which could be beneficial to rowing performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The short duration of the Doppler signal and noise content in it necessitate a validation scheme to be incorporated in the electronic processor used for frequency measurement, There are several different validation schemes that can be employed in period timing devices. A detailed study of the influence of these validation schemes on the measured frequency has been reported here. These studies were carried out by using a combination of a fast A/D converter and computer. Doppler bursts obtained from an air flow were digitised and stored on magnetic discs. Suitable computer programs were then used to simulate the performance of period timing devices with different validation schemes and the frequency of the stored bursts were evaluated. It is found that best results are obtained when the validation scheme enables frequency measurement to be made over a large number of cycles within the burst.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ms Breathless is a 59-year-old lady living with chronic obstructive pulmonary disease (COPD) for several years now, and quit smoking over 20 years ago. She sometimes experiences symptoms of breathlessness, and an unrelenting productive cough, particularly when she comes in contact with dusty places, second-hand smoke, or when her allergies and hay fever play up. Apart from these triggers, her symptoms are well maintained with her inhalers glycopyrronium bromide (Seebri) and indacaterol (Onbrez), and she has been using them for about nine months. Ms Breathless is otherwise healthy, and not taking any other medicines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Use of socket prostheses Currently, for individuals with limb loss, the conventional method of attaching a prosthetic limb relies on a socket that fits over the residual limb. However, there are a number of issues concerning the use of a socket (e.g., blisters, irritation, and discomfort) that result in dissatisfaction with socket prostheses, and these lead ultimately a significant decrease in quality of life. Bone-anchored prosthesis Alternatively, the concept of attaching artificial limbs directly to the skeletal system has been developed (bone anchored prostheses), as it alleviates many of the issues surrounding the conventional socket interface.Bone anchored prostheses rely on two critical components: the implant, and the percutaneous abutment or adapter, which forms the connection for the external prosthetic system (Figure 1). To date, an implant that screws into the long bone of the residual limb has been the most common intervention. However, more recently, press-fit implants have been introduced and their use is increasing. Several other devices are currently at various stages of development, particularly in Europe and the United States. Benefits of bone-anchored prostheses Several key studies have demonstrated that bone-anchored prostheses have major clinical benefits when compared to socket prostheses (e.g., quality of life, prosthetic use, body image, hip range of motion, sitting comfort, ease of donning and doffing, osseoperception (proprioception), walking ability) and acceptable safety, in terms of implant stability and infection. Additionally, this method of attachment allows amputees to participate in a wide range of daily activities for a substantially longer duration. Overall, the system has demonstrated a significant enhancement to quality of life. Challenges of direct skeletal attachment However, due to the direct skeletal attachment, serious injury and damage can occur through excessive loading events such as during a fall (e.g., component damage, peri-prosthetic fracture, hip dislocation, and femoral head fracture). These incidents are costly (e.g., replacement of components) and could require further surgical interventions. Currently, these risks are limiting the acceptance of bone-anchored technology and the substantial improvement to quality of life that this treatment offers. An in-depth investigation into these risks highlighted a clear need to re-design and improve the componentry in the system (Figure 2), to improve the overall safety during excessive loading events. Aim and purposes The ultimate aim of this doctoral research is to improve the loading safety of bone-anchored prostheses, to reduce the incidence of injury and damage through the design of load restricting components, enabling individuals fitted with the system to partake in everyday activities, with increased security and self-assurance. The safety component will be designed to release or ‘fail’ external to the limb, in a way that protects the internal bone-implant interface, thus removing the need for restorative surgery and potential damage to the bone. This requires detailed knowledge of the loads typically experienced by the limb and an understanding of potential overload situations that might occur. Hence, a comprehensive review of the loading literature surrounding bone anchored prostheses will be conducted as part of this project, with the potential for additional experimental studies of the loads during normal activities to fill in gaps in the literature. This information will be pivotal in determining the specifications for the properties of the safety component, and the bone-implant system. The project will follow the Stanford Biodesign process for the development of the safety component.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The unsteady laminar compressible three-dimensional stagnation-point boundary-layer flow with variable properties has been studied when the velocity of the incident stream, mass transfer and wall temperature vary arbitrarily with time. The second-order unsteady boundary-layer equations for all the effects have been derived by using the method of matched asymptotic expansions. Both nodal and saddle point flows as well as cold and hot wall cases have been considered. The partial differential equations governing the flow have been solved numerically using an implicit finite-difference scheme. Computations have been carried out for an accelerating stream, a decelerating stream and a fluctuating stream. The results indicate that the unsteady free stream velocity distributions, the nature of the stagnation point, the mass transfer, the wall temperature and the variation of the density-viscosity product across the boundary significantly affect the skin friction and heat transfer. The variation of the wall temperature with time strongly affects the heat transfer whereas its effect is comparatively less on skin friction. Suction increases the skin friction and heat transfer but injection does the opposite. The skin friction in the x direction due to the combined effects of first- and second-order boundary layers is less than the skin-friction in the x direction due to the first-order boundary layers for all the parameters. The overall skin friction in the z direction and heat transfer are more or less than the first-order boundary layers depending upon the values of the various parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Forage budgeting, land condition monitoring and maintaining ground cover residuals are critical management practices for the long term sustainability of the northern grazing industry. The aim of this project is to do a preliminary investigation into industry need, feasibility and willingness to adopt a simple to use hand-held hardware device and compatible, integrated software applications that can be used in the paddock by producers, to assist in land condition monitoring and forage budgeting for better Grazing Land Management and to assist with compliance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Body fat distribution is a heritable trait and a well-established predictor of adverse metabolic outcomes, independent of overall adiposity. To increase our understanding of the genetic basis of body fat distribution and its molecular links to cardiometabolic traits, here we conduct genome-wide association meta-analyses of traits related to waist and hip circumferences in up to 224,459 individuals. We identify 49 loci (33 new) associated with waist-to-hip ratio adjusted for body mass index (BMI), and an additional 19 loci newly associated with related waist and hip circumference measures (P < 5 × 10−8). In total, 20 of the 49 waist-to-hip ratio adjusted for BMI loci show significant sexual dimorphism, 19 of which display a stronger effect in women. The identified loci were enriched for genes expressed in adipose tissue and for putative regulatory elements in adipocytes. Pathway analyses implicated adipogenesis, angiogenesis, transcriptional regulation and insulin resistance as processes affecting fat distribution, providing insight into potential pathophysiological mechanisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obesity is heritable and predisposes to many diseases. To understand the genetic basis of obesity better, here we conduct a genome-wide association study and Metabochip meta-analysis of body mass index (BMI), a measure commonly used to define obesity and assess adiposity, in up to 339,224 individuals. This analysis identifies 97 BMI-associated loci (P < 5 × 10−8), 56 of which are novel. Five loci demonstrate clear evidence of several independent association signals, and many loci have significant effects on other metabolic phenotypes. The 97 loci account for ~2.7% of BMI variation, and genome-wide estimates suggest that common variation accounts for >20% of BMI variation. Pathway analyses provide strong support for a role of the central nervous system in obesity susceptibility and implicate new genes and pathways, including those related to synaptic function, glutamate signalling, insulin secretion/action, energy metabolism, lipid biology and adipogenesis.