970 resultados para Blood sugar monitoring.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Thus far, the correlation of noninvasive markers with endoscopic activity in ulcerative colitis (UC) according to the modified Baron Index is unknown. We aimed to evaluate the correlation between endoscopic activity and fecal calprotectin (FC), C-reactive protein (CRP), blood leukocytes, and the Lichtiger Index (clinical score). Methods: UC patients undergoing complete colonoscopy were prospectively enrolled and scored clinically and endoscopically in an independent fashion. Fecal and blood samples were analyzed in UC patients and controls. Results: We enrolled 228 UC patients and 52 controls. Endoscopic disease activity correlated best with FC (Spearman's rank correlation coefficient r = 0.821), followed by the Lichtiger Index (r = 0.682), CRP (r = 0.556), and leukocytes (r = 0.401). FC was the only marker discriminating between different grades of endoscopic activity (grade 0, 20}11 mg/g; grade 1, 44}34 mg/g; grade 2, 111}74 mg/g; grade 3, 330}332 mg/g; grade 4, 659}319 mg/g; P = 0.0018 for discriminating grade 0 vs. 1 and P < 0.001 for discriminating all other grades). FC had the highest overall accuracy (91%) to detect endoscopically active disease (modified Baron Index _2), followed by the Lichtiger Index of _4 (77%), CRP larger than 5 mg/L (69%) and blood leukocytosis (58%). Conclusions: FC better correlated with the endoscopic disease activity than clinical activity, CRP, and blood leukocytes. The strong correlation with endoscopic disease activity suggests that FC represents a useful biomarker for noninvasive monitoring of disease activity in UC patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rapport de synthèse : Hypoglycémies nocturnes chez les patients diabétiques de type 1 : que pouvons-nous apprendre de la mesure de la glycémie en continu ? But : les hypoglycémies nocturnes sont une complication majeure du traitement des patients diabétiques de type 1; des autocontrôles de la glycémie capillaire sont donc recommandés pour les détecter. Cependant, la majorité des hypoglycémies nocturnes ne sont pas décelées par un autocontrôle glycémique durant la nuit. La mesure de la glycémie en continu (CGMS) est une alternative intéressante. Les buts de cette étude rétrospective étaient d'évaluer la véritable incidence des hypoglycémies nocturnes chez des patients diabétiques de type 1, la meilleure période pour effectuer un autocontrôle permettant de prédire une hypoglycémie nocturne, la relation entre les hyperglycémies matinales et les hypoglycémies nocturnes (phénomène de Somogyi) ainsi que l'utilité du CGMS pour réduire les hypoglycémies nocturnes. Méthode : quatre-vingt-huit patients diabétiques de type 1 qui avaient bénéficié d'un CGMS ont été inclus. Les indications au CGMS, les hypoglycémies nocturnes et diurnes ainsi que la corrélation entre les hypoglycémies nocturnes et les hyperglycémies matinales durant le CGMS ont été enregistrées. L'efficacité du CGMS pour réduire les hypoglycémies nocturnes a été évaluée six à neuf mois après. Résultats : la prévalence des hypoglycémies nocturnes était de 67% (32% non suspectées). La sensibilité d'une hypoglycémie à prédire une hypoglycémie nocturne était de 37% (OR = 2,37, P = 0,001) lorsqu'elle survient au coucher (22-24 h) et de 43% lorsqu'elle survient à 3 h (OR = 4,60, P < 0,001). Les hypoglycémies nocturnes n'étaient pas associées à des hyperglycémies matinales, mais à des hypoglycémies matinales (OR = 3.95, P < 0.001). Six à neuf mois après le CGMS, les suspicions cliniques d'hypoglycémies nocturnes ont diminué de 60% à 14% (P < 0.001). Abstract : Aim. - In type 1 diabetic patients (TIDM), nocturnal hypoglycaemias (Nlï) are a serious complication of T1DM treatment; self-monitoring of blood glucose (SMBG) is recommended to detect them. However, the majority of NH remains undetected on an occasional SMBG done during the night. An alternative strategy is the Continuous glucose monitoring (CGMS), which retrospectively shows the glycaemic profile. The aims of this retrospective study were to evaluate the true incidence of NH in TiDM, the bèst SMBG time to predict NH, the relationship between morning hyperglycaemia and N$ (Somogyi phenomenon) and the utility of CGMS to reduce NH. Methods. -Eighty-eight T1DM who underwent a CGMS exam were included. Indications for CGMS evaluarion, hypoglycaemias and correlation with morning hyperglycaemias were recorded. The efficiency of CGMS to reduce the suspected NH was evaluated after 6-9 months. Results. -The prevalence of NH was 67% (32% of them unsuspected). A measured hypoglycaemia at bedtime (22-24 h) had a sensitivity of 37% to detect NH (OR = 2.37, P = 0.001), while a single measure <_ 4 mmol/l at 3-hour had a sensitivity of 43% (OR = 4.60, P < 0.001). NH were not associated with morning hyperglycaemias but with morning hypoglycaemias (OR = 3.95, P < 0.001). After 6-9 months, suspicions of NH decreased from 60 to 14% (P < 0.001). Conclusion. - NH were highly prevalent and often undetected. SMBG at bedtime, which detected hypoglycaemia had sensitivity almost equal to that of 3-hour and should be preferred because it is easier to perform. Somogyi phenomenon was not observed. CGMS is useful to reduce the risk of NH in 75% of patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: An important goal of neurocritical care is the management of secondary brain injury (SBI), that is pathological events occurring after primary insult that add further burden to outcome. Brain oedema, cerebral ischemia, energy dysfunction, seizures and systemic insults are the main components of SBI. We here review recent data showing the clinical utility of brain multimodality monitoring (BMM) for the management of SBI. RECENT FINDINGS: Despite being recommended by international guidelines, standard intracranial pressure (ICP) monitoring may be insufficient to detect all episodes of SBI. ICP monitoring, combined with brain oxygen (PbtO(2)), cerebral microdialysis and regional cerebral blood flow, might help to target therapy (e.g. management of cerebral perfusion pressure, blood transfusion, glucose control) to patient-specific pathophysiology. Physiological parameters derived from BMM, including PbtO(2) and microdialysis lactate/pyruvate ratio, correlate with outcome and have recently been incorporated into neurocritical care guidelines. Advanced intracranial devices can be complemented by quantitative electroencephalography to monitor changes of brain function and nonconvulsive seizures. SUMMARY: BMM offers an on-line comprehensive scrutiny of the injured brain and is increasingly used for the management of SBI. Integration of monitored data using new informatics tools may help optimize therapy of brain-injured patients and quality of care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Pre-existing psychological factors can strongly influence coping with type 1 diabetes mellitus and interfere with self-monitoring. Psychiatric disorders seem to be positively associated with poor metabolic control. We present a case of extreme compulsive blood testing due to obsessive fear of hypoglycemia in an adolescent with type 1 diabetes mellitus. Case report: Type 1 diabetes mellitus (anti GAD-antibodies 2624 U/l, norm < 9.5) was diagnosed in a boy aged 14.3 years [170 cm (+ 0.93 SDS), weight 50.5 kg (+ 0.05 SDS)]. Laboratory work-up showed no evidence for other autoimmune disease. Family and past medical history were unremarkable. Growth and developmental milestones were normal. Insulin-analog based basal-bolus regime was initiated, associated to standard diabetic education. Routine psychological evaluation performed at the onset of diabetes revealed intermittent anxiety and obsessivecompulsive traits. Accordingly, a close psychiatric follow-up was initiated for the patient and his family. An adequate metabolic control (HbA1c drop from >14 to 8%) was achieved within 3 months, attributed to residual -cell function. In the following 6 months, HbA1c rose unexpectedly despite seemingly adequate adaptations of insulin doses. Obsessive fear of hypoglycemia leading to a severe compulsive behavior developed progressively with as many as 68 glycemia measurements per day (mean over 1 week). The patient reported that he could not bear leaving home with glycemia < 15 mmol/l, ending up with school eviction and severe intra-familial conflict. Despite intensive psychiatric outpatient support, HbA1c rose rapidly to >14% with glycemia-testing reaching peaks of 120 tests/day. The situation could only be discontinued through psychiatric hospitalization with intensive behavioral training. As a result, adequate metabolic balance was restored (HbA1c value: 7.1 %) with acceptable 10-15 daily glycemia measurements. Discussion: The association of overt psychiatric disorders to type 1 diabetes mellitus is very rare in the pediatric age group. It can lead to a pathological behavior with uncontrolled diabetes. Such exceptional situations require long-term admissions with specialized psychiatric care. Slow acceptation of a "less is better" principle in glycemia testing and amelioration of metabolic control are difficult to achieve.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An assay for the simultaneous analysis of pharmaceutical compounds and their metabolites from micro-whole blood samples (i.e. 5 microL) was developed using an on-line dried blood spot (on-line DBS) device coupled with hydrophilic interaction/reversed-phase (HILIC/RP) LC/MS/MS. Filter paper is directly integrated to the LC device using a homemade inox desorption cell. Without any sample pretreatment, analytes are desorbed from the paper towards an automated system of valves linking a zwitterionic-HILIC column to an RP C18 column. In the same run, the polar fraction is separated by the zwitterionic-HILIC column while the non-polar fraction is eluted on the RP C18. Both fractions are detected by IT-MS operating in full scan mode for the survey scan and in product ion mode for the dependant scan using an ESI source. The procedure was evaluated by the simultaneous qualitative analysis of four probes and their relative phase I and II metabolites spiked in whole blood. In addition, the method was successfully applied to the in vivo monitoring of buprenorphine metabolism after the administration of an intraperitoneal injection of 30 mg/kg on adult female Wistar rat.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Five selective serotonin reuptake inhibitors (SSRIs) have been introduced recently: citalopram, fluoxetine, fluvoxamine, paroxetine and sertraline. Although no therapeutic window has been defined for SSRIs, in contrast to tricyclic antidepressants, analytical methods for therapeutic drug monitoring of SSRIs are useful in several instances. SSRIs differ widely in their chemical structure and in their metabolism. The fact that some of them have N-demethylated metabolites, which are also SSRIs, requires that methods be available which allow therapeutic drug monitoring of the parent compounds and of these active metabolites. most procedures are based on prepurification of the SSRIs by liquid-liquid extraction before they are submitted to separation by chromatographic procedures (high-performance liquid chromatography, gas chromatography, thin layer chromatography) and detection by various detectors (UV, fluorescence, electrochemical detector, nitrogen-phosphorus detector, mass spectrometry). This literature review shows that most methods allow quantitative determination of SSRIs in plasma, in the lower ng/ml range, and that they are, therefore, suitable for therapeutic drug monitoring purposes of this category of drugs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present work describes a fast gas chromatography/negative-ion chemical ionization tandem mass spectrometric assay (Fast GC/NICI-MS/MS) for analysis of tetrahydrocannabinol (THC), 11-hydroxy-tetrahydrocannabinol (THC-OH) and 11-nor-9-carboxy-tetrahydrocannabinol (THC-COOH) in whole blood. The cannabinoids were extracted from 500 microL of whole blood by a simple liquid-liquid extraction (LLE) and then derivatized by using trifluoroacetic anhydride (TFAA) and hexafluoro-2-propanol (HFIP) as fluorinated agents. Mass spectrometric detection of the analytes was performed in the selected reaction-monitoring mode on a triple quadrupole instrument after negative-ion chemical ionization. The assay was found to be linear in the concentration range of 0.5-20 ng/mL for THC and THC-OH, and of 2.5-100 ng/mL for THC-COOH. Repeatability and intermediate precision were found less than 12% for all concentrations tested. Under standard chromatographic conditions, the run cycle time would have been 15 min. By using fast conditions of separation, the assay analysis time has been reduced to 5 min, without compromising the chromatographic resolution. Finally, a simple approach for estimating the uncertainty measurement is presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a viscometric affinity biosensor that can potentially allow continuous multi-analyte monitoring in biological fluids like blood or plasma. The sensing principle is based on the detection of viscosity changes of a polymeric solution which has a selective affinity for the analyte of interest. The chemico-mechanical sensor incorporates an actuating piezoelectric diaphragm, a sensing piezoelectric diaphragm and a flow-resisting microchannel for viscosity detection. A free-standing Anodic Alumina Oxide (AAO) porous nano-membrane is used as selective interface. A glucose-sensitive sensor was fabricated and extensively assessed in buffer solution. The sensor reversibility, stability and sensitivity were excellent during at least 65 hours. Results showed also a good degree of stability for a long term measurement (25 days). The sensor behaviour was furthermore tested in fetal bovine serum (FBS). The obtained results for glucose sensing are very promising, indicating that the developed sensor is a candidate for continuous monitoring in biological fluids. Sensitive solutions for ionized calcium and pH are currently under development and should allow multi-analyte sensing in the near future.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: As imatinib pharmacokinetics are highly variable, plasma levels differ largely between patients under the same dosage. Retrospective studies in chronic myeloid leukemia (CML) patients showed significant correlations between low levels and suboptimal response, and between high levels and poor tolerability. Monitoring of plasma levels is thus increasingly advised, targeting trough concentrations of 1000 μg/L and above. Objectives: Our study was launched to assess the clinical usefulness of systematic imatinib TDM in CML patients. The present preliminary evaluation questions the appropriateness of dosage adjustment following plasma level measurement to reach the recommended trough level, while allowing an interval of 4-24 h after last drug intake for blood sampling. Methods: Initial blood samples from the first 9 patients in the intervention arm were obtained 4-25 h after last dose. Trough levels in 7 patients were predicted to be significantly away from the target (6 <750 μg/L, and 1 >1500 μg/L with poor tolerance), based on a Bayesian approach using a population pharmacokinetic model. Individual dosage adjustments were taken up in 5 patients, who had a control measurement 1-4 weeks after dosage change. Predicted trough levels were confronted to anterior model-based extrapolations. Results: Before dosage adjustment, observed concentrations extrapolated at trough ranged from 359 to 1832 μg/L (median 710; mean 804, CV 53%) in the 9 patients. After dosage adjustment they were expected to target between 720 and 1090 μg/L (median 878; mean 872, CV 13%). Observed levels of the 5 recheck measurements extrapolated at trough actually ranged from 710 to 1069 μg/L (median 1015; mean 950, CV 16%) and had absolute differences of 21 to 241 μg/L to the model-based predictions (median 175; mean 157, CV 52%). Differences between observed and predicted trough levels were larger when intervals between last drug intake and sampling were very short (~4 h). Conclusion: These preliminary results suggest that TDM of imatinib using a Bayesian interpretation is able to bring trough levels closer to 1000 μg/L (with CV decreasing from 53% to 16%). While this may simplify blood collection in daily practice, as samples do not have to be drawn exactly at trough, the largest possible interval to last drug intake yet remains preferable. This encourages the evaluation of the clinical benefit of a routine TDM intervention in CML patients, which the randomized Swiss I-COME study aims to.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: In acute respiratory failure, arterial blood gas analysis (ABG) is used to diagnose hypercapnia. Once non-invasive ventilation (NIV) is initiated, ABG should at least be repeated within 1 h to assess PaCO2 response to treatment in order to help detect NIV failure. The main aim of this study was to assess whether measuring end-tidal CO2 (EtCO2) with a dedicated naso-buccal sensor during NIV could predict PaCO2 variation and/or PaCO2 absolute values. The additional aim was to assess whether active or passive prolonged expiratory maneuvers could improve the agreement between expiratory CO2 and PaCO2. METHODS: This is a prospective study in adult patients suffering from acute hypercapnic respiratory failure (PaCO2 ≥ 45 mmHg) treated with NIV. EtCO2 and expiratory CO2 values during active and passive expiratory maneuvers were measured using a dedicated naso-buccal sensor and compared to concomitant PaCO2 values. The agreement between two consecutive values of EtCO2 (delta EtCO2) and two consecutive values of PaCO2 (delta PaCO2) and between PaCO2 and concomitant expiratory CO2 values was assessed using the Bland and Altman method adjusted for the effects of repeated measurements. RESULTS: Fifty-four datasets from a population of 11 patients (8 COPD and 3 non-COPD patients), were included in the analysis. PaCO2 values ranged from 39 to 80 mmHg, and EtCO2 from 12 to 68 mmHg. In the observed agreement between delta EtCO2 and deltaPaCO2, bias was -0.3 mmHg, and limits of agreement were -17.8 and 17.2 mmHg. In agreement between PaCO2 and EtCO2, bias was 14.7 mmHg, and limits of agreement were -6.6 and 36.1 mmHg. Adding active and passive expiration maneuvers did not improve PaCO2 prediction. CONCLUSIONS: During NIV delivered for acute hypercapnic respiratory failure, measuring EtCO2 using a dedicating naso-buccal sensor was inaccurate to predict both PaCO2 and PaCO2 variations over time. Active and passive expiration maneuvers did not improve PaCO2 prediction. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01489150.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this work was to combine the advantages of the dried blood spot (DBS) sampling process with the highly sensitive and selective negative-ion chemical ionization tandem mass spectrometry (NICI-MS-MS) to analyze for recent antidepressants including fluoxetine, norfluoxetine, reboxetine, and paroxetine from micro whole blood samples (i.e., 10 microL). Before analysis, DBS samples were punched out, and antidepressants were simultaneously extracted and derivatized in a single step by use of pentafluoropropionic acid anhydride and 0.02% triethylamine in butyl chloride for 30 min at 60 degrees C under ultrasonication. Derivatives were then separated on a gas chromatograph coupled with a triple-quadrupole mass spectrometer operating in negative selected reaction monitoring mode for a total run time of 5 min. To establish the validity of the method, trueness, precision, and selectivity were determined on the basis of the guidelines of the "Société Française des Sciences et des Techniques Pharmaceutiques" (SFSTP). The assay was found to be linear in the concentration ranges 1 to 500 ng mL(-1) for fluoxetine and norfluoxetine and 20 to 500 ng mL(-1) for reboxetine and paroxetine. Despite the small sampling volume, the limit of detection was estimated at 20 pg mL(-1) for all the analytes. The stability of DBS was also evaluated at -20 degrees C, 4 degrees C, 25 degrees C, and 40 degrees C for up to 30 days. Furthermore, the method was successfully applied to a pharmacokinetic investigation performed on a healthy volunteer after oral administration of a single 40-mg dose of fluoxetine. Thus, this validated DBS method combines an extractive-derivative single step with a fast and sensitive GC-NICI-MS-MS technique. Using microliter blood samples, this procedure offers a patient-friendly tool in many biomedical fields such as checking treatment adherence, therapeutic drug monitoring, toxicological analyses, or pharmacokinetic studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss-Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss-Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND & AIMS: Trace elements (TE) are involved in the immune and antioxidant defences which are of particular importance during critical illness. Determining plasma TE levels is costly. The present quality control study aimed at assessing the economic impact of a computer reminded blood sampling versus a risk guided on-demand monitoring of plasma concentrations of selenium, copper, and zinc. METHODS: Retrospective analysis of 2 cohorts of patients admitted during 6 months periods in 2006 and 2009 to the ICU of a University hospital. INCLUSION CRITERIA: to receive intravenous micronutrient supplements and/or to have a TE sampling during ICU stay. The TE samplings were triggered by computerized reminder in 2006 versus guided by nutritionists in 2009. RESULTS: During the 2 periods 636 patients met the inclusion criteria out of 2406 consecutive admissions, representing 29.7% and 24.9% respectively of the periods' admissions. The 2009 patients had higher SAPS2 scores (p = 0.02) and lower BMI compared to 2006 (p = 0.007). The number of laboratory determinations was drastically reduced in 2009, particularly during the first week, despite the higher severity of the cohort, resulting in à 55% cost reduction. CONCLUSIONS: The monitoring of TE concentrations guided by a nutritionist resulted in a reduction of the sampling frequency, and targeting on the sickest high risk patients, requiring a nutritional prescription adaptation. This control leads to cost reduction compared to an automated sampling prescription.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Adequate empirical antibiotic dose selection for critically ill burn patients is difficult due to extreme variability in drug pharmacokinetics. Therapeutic drug monitoring (TDM) may aid antibiotic prescription and implementation of initial empirical antimicrobial dosage recommendations. This study evaluated how gradual TDM introduction altered empirical dosages of meropenem and imipenem/cilastatin in our burn ICU. METHODS: Imipenem/cilastatin and meropenem use and daily empirical dosage at a five-bed burn ICU were analyzed retrospectively. Data for all burn admissions between 2001 and 2011 were extracted from the hospital's computerized information system. For each patient receiving a carbapenem, episodes of infection were reviewed and scored according to predefined criteria. Carbapenem trough serum levels were characterized. Prior to May 2007, TDM was available only by special request. Real-time carbapenem TDM was introduced in June 2007; it was initially available weekly and has been available 4 days a week since 2010. RESULTS: Of 365 patients, 229 (63%) received antibiotics (109 received carbapenems). Of 23 TDM determinations for imipenem/cilastatin, none exceeded the predefined upper limit and 11 (47.8%) were insufficient; the number of TDM requests was correlated with daily dose (r=0.7). Similar numbers of inappropriate meropenem trough levels (30.4%) were below and above the upper limit. Real-time TDM introduction increased the empirical dose of imipenem/cilastatin, but not meropenem. CONCLUSIONS: Real-time carbapenem TDM availability significantly altered the empirical daily dosage of imipenem/cilastatin at our burn ICU. Further studies are needed to evaluate the individual impact of TDM-based antibiotic adjustment on infection outcomes in these patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The variability observed in drug exposure has a direct impact on the overall response to drug. The largest part of variability between dose and drug response resides in the pharmacokinetic phase, i.e. in the dose-concentration relationship. Among possibilities offered to clinicians, Therapeutic Drug Monitoring (TDM; Monitoring of drug concentration measurements) is one of the useful tool to guide pharmacotherapy. TDM aims at optimizing treatments by individualizing dosage regimens based on blood drug concentration measurement. Bayesian calculations, relying on population pharmacokinetic approach, currently represent the gold standard TDM strategy. However, it requires expertise and computational assistance, thus limiting its large implementation in routine patient care. The overall objective of this thesis was to implement robust tools to provide Bayesian TDM to clinician in modern routine patient care. To that endeavour, aims were (i) to elaborate an efficient and ergonomic computer tool for Bayesian TDM: EzeCHieL (ii) to provide algorithms for drug concentration Bayesian forecasting and software validation, relying on population pharmacokinetics (iii) to address some relevant issues encountered in clinical practice with a focus on neonates and drug adherence. First, the current stage of the existing software was reviewed and allows establishing specifications for the development of EzeCHieL. Then, in close collaboration with software engineers a fully integrated software, EzeCHieL, has been elaborated. EzeCHieL provides population-based predictions and Bayesian forecasting and an easy-to-use interface. It enables to assess the expectedness of an observed concentration in a patient compared to the whole population (via percentiles), to assess the suitability of the predicted concentration relative to the targeted concentration and to provide dosing adjustment. It allows thus a priori and a posteriori Bayesian drug dosing individualization. Implementation of Bayesian methods requires drug disposition characterisation and variability quantification trough population approach. Population pharmacokinetic analyses have been performed and Bayesian estimators have been provided for candidate drugs in population of interest: anti-infectious drugs administered to neonates (gentamicin and imipenem). Developed models were implemented in EzeCHieL and also served as validation tool in comparing EzeCHieL concentration predictions against predictions from the reference software (NONMEM®). Models used need to be adequate and reliable. For instance, extrapolation is not possible from adults or children to neonates. Therefore, this work proposes models for neonates based on the developmental pharmacokinetics concept. Patients' adherence is also an important concern for drug models development and for a successful outcome of the pharmacotherapy. A last study attempts to assess impact of routine patient adherence measurement on models definition and TDM interpretation. In conclusion, our results offer solutions to assist clinicians in interpreting blood drug concentrations and to improve the appropriateness of drug dosing in routine clinical practice.