938 resultados para Balão térmico


Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the emergence of new technologies, has grown the need to use new materials, and this has intensified research on the collection and use of materials from renewable sources, is to reduce production costs and / or environmental impact. In this context, it was found that the sheath coconut straw, can be utilized as raw material for the production of a eco-composite that can be used as a thermal and acoustic insulator. After selected from the coconut sheaths were subjected to treatment with aqueous 2 % sodium hydroxide (NaOH). The composite study was produced with the sheath and coconut natural latex, with coconut sheath percentage in the proportions 15%, 25% and 35% of the total compound volume. Physical, thermal and acoustic properties of the composites were analyzed in order to obtain data on the use of viability as thermoacoustic insulation. The CP15 composites, CP25 and CP35 showed thermal conductivity 0.188 W/m.K, 0.155 W/m.K and 0.150 W/m.K, respectively. It can be applied as thermal insulation in hot systems to 200 ° C. The CP35 composite was more efficient as a thermal and acoustic insulation, providing 20% noise reduction, 31% and 34% for frequencies of 1 kHz, 2 kHz and 4 kHz, respectively. The analyzes were based on ABNT, ASTM, UL. Based on these results, it can be concluded that the eco-composite produced the hem of coconut can be used as thermal and acoustic insulation. Thus, it gives a more noble end to this material, which most often is burned or disposed of improperly in the environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Squamous cell carcinoma of oral tongue shows high rates of morbidity and mortality in the population, therefore, great efforts are being made to classify morphological changes and identify biomarkers that have prognostic value and that are able to group patients in individualized therapeutic options. From this perspective, there is the heat shock factor 1 (HSF1), which is a heat shock factor transcription protein (HSPs) that allows the cancer to deal with stressors associated with malignancy, acting differently in tumor progression. This research aimed to perform a clinico-pathological analysis of 70 cases of oral tongue squamous cell carcinoma (OTSCC) and immunohistochemical study of the expression of HSF1 protein in OTSCC, comparing it with 30 specimens of normal oral mucosa (NOM), and correlating this immunostaining with clinico-pathological aspects of OTSCC. To analyze the association between immunoexpression of HSF1 and clinicophatoloical aspects, the cases were categorized in minor and major overexpression, based in the median immunostaining score. Regarding the cases of OTSCC, 57.1% showed clinical stage III or IV, 82.9% were graded as high grade according to Bryne (1998) and 47.1% as high risk of malignancy according to Brandwein-Gensler et al., (2005). A disease free survival rate of 47.84% and overall survival rate of 68.20% was observed in the analyzed cases, and the high degree of malignancy according to Bryne’s system (1998) (p=0.05), tumor size T3 or T4 (p=0.04), local recurrence (p=0.02), and perineural invasion (p=0.02) determined negative impacts in survival time. We observed also a statistically significant result (p<0.01) when comparing the immunoreactivity of HSF1 between NOM and OTSCC. This significantly increased expression of HSF1 in cases of OTSCC suggests that this protein acts, indeed, in the pathogenesis of this disease. However, there were no statistically significant associations between this overexpression and the clinico-pathological parameters analyzed. This finding may reflect the influence of epigenetic events on HSF1 gene or a possible stability of this protein expression throughout disease progression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Squamous cell carcinoma of oral tongue shows high rates of morbidity and mortality in the population, therefore, great efforts are being made to classify morphological changes and identify biomarkers that have prognostic value and that are able to group patients in individualized therapeutic options. From this perspective, there is the heat shock factor 1 (HSF1), which is a heat shock factor transcription protein (HSPs) that allows the cancer to deal with stressors associated with malignancy, acting differently in tumor progression. This research aimed to perform a clinico-pathological analysis of 70 cases of oral tongue squamous cell carcinoma (OTSCC) and immunohistochemical study of the expression of HSF1 protein in OTSCC, comparing it with 30 specimens of normal oral mucosa (NOM), and correlating this immunostaining with clinico-pathological aspects of OTSCC. To analyze the association between immunoexpression of HSF1 and clinicophatoloical aspects, the cases were categorized in minor and major overexpression, based in the median immunostaining score. Regarding the cases of OTSCC, 57.1% showed clinical stage III or IV, 82.9% were graded as high grade according to Bryne (1998) and 47.1% as high risk of malignancy according to Brandwein-Gensler et al., (2005). A disease free survival rate of 47.84% and overall survival rate of 68.20% was observed in the analyzed cases, and the high degree of malignancy according to Bryne’s system (1998) (p=0.05), tumor size T3 or T4 (p=0.04), local recurrence (p=0.02), and perineural invasion (p=0.02) determined negative impacts in survival time. We observed also a statistically significant result (p<0.01) when comparing the immunoreactivity of HSF1 between NOM and OTSCC. This significantly increased expression of HSF1 in cases of OTSCC suggests that this protein acts, indeed, in the pathogenesis of this disease. However, there were no statistically significant associations between this overexpression and the clinico-pathological parameters analyzed. This finding may reflect the influence of epigenetic events on HSF1 gene or a possible stability of this protein expression throughout disease progression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Compete aos agentes que concebem os edifícios, bem como aos legisladores e aos promotores, dotá-los com o máximo possível de tecnologias passivas que permitam ao utilizador economizar, sem no entanto perder conforto nem salubridade. O presente estudo consiste num trabalho de revisão bibliográfica e de investigação experimental com vista à avaliação do comportamento dinâmico de paredes de alvenaria de tijolo térmico. Aferiu-se o desempenho térmico deste tipo de paredes e a viabilidade da sua utilização essencialmente numa perspetiva da redução dos consumos energéticos e de garantia do conforto térmico e salubridade nos edifícios. Os tijolos térmicos estão cada vez mais a ser introduzidos na construção devido ainda à simplicidade na construção e a possível eliminação/redução do material isolante. Neste trabalho construiu-se uma célula de teste com paredes constituídas por este tipo de tijolo, o Bloco ThermoPrélis, cedido pela empresa PRELIS Lda. Assim, mediu-se o desempenho térmico do mesmo em condições reais, em períodos nas estações de primavera e do verão. Os resultados experimentais mostram claramente as vantagens da construção com este tipo de tijolo, que apresenta um atraso térmico de 7 a 8 horas e um amortecimento da amplitude térmica no ambiente interior bastante significativo, tirando partido do mecanismo físico associado à inércia térmica. Em termos de custos, a construção com tijolo térmico apresenta vantagens, quando comparado com a construção típica em parede dupla com isolamento térmico na caixa-de-ar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El Ecosistema de Afloramiento Peruano (EAP) es una de las zonas marinas con mayor productividad pesquera en el mundo y por su ubicación geográfica, es afectada por procesos físicos remotos, principalmente por la variabilidad climática interanual proveniente del océano Pacifico Ecuatorial, cuya señal dominante es El Niño y la Oscilación Sur (ENOS). Con el fin de evaluar los efectos de ENOS frente al Perú, se desarrolló el Índice Térmico Costero Peruano (ITCP) que representa el 87,7% de la variación total de las anomalías de la temperatura superficial del mar del EAP. Se analizó el periodo 1982-2014, detectándose 12 periodos con condiciones cálidas y 16 con condiciones frías. El ITCP tuvo una tendencia lineal, un componente de bajas frecuencias y un componente de ruido, con 1,5%, 94,5 % y 4 % de contribución a la varianza total, respectivamente. El ITCP presenta ventajas respecto a otros índices climáticos de la costa peruana, porque comprende el área representativa del Ecosistema de Afloramiento Peruano y porque captura la señal del afloramiento costero así como de los efectos térmicos de El Niño y La Niña.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[ES] Se presenta una aplicación que utiliza información de varios sensores satelitales a diferentes escalas para hacer el seguimiento de la evolución espacio-temporal de 8 ejemplares juveniles de tortuga boba (Caretta caretta) que fueron equipados con trasmisores ARGOS en las Islas Canarias entre 1999 y 2000. Consiste en una base de datos multisensor y multiescala que se fusiona con los datos de posicionamiento y buceos para producir conjuntos multiparamétricos que pueden analizarse desde el punto de vista ecofisiológico. Del uso de la aplicación se infiere información interesante sobre el comportamiento migratorio de estos reptiles en la región macaronésica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays, evaluation methods to measure thermal performance of buildings have been developed in order to improve thermal comfort in buildings and reduce the use of energy with active cooling and heating systems. However, in developed countries, the criteria used in rating systems to asses the thermal and energy performance of buildings have demonstrated some limitations when applied to naturally ventilated building in tropical climates. The present research has as its main objective to propose a method to evaluate the thermal performance of low-rise residential buildings in warm humid climates, through computational simulation. The method was developed in order to conceive a suitable rating system for the athermal performance assessment of such buildings using as criteria the indoor air temperature and a thermal comfort adaptive model. The research made use of the software VisualDOE 4.1 in two simulations runs of a base case modeled for two basic types of occupancies: living room and bedroom. In the first simulation run, sensitive analyses were made to identify the variables with the higher impact over the cases´ thermal performance. Besides that, the results also allowed the formulation of design recommendations to warm humid climates toward an improvement on the thermal performance of residential building in similar situations. The results of the second simulation run was used to identify the named Thermal Performance Spectrum (TPS) of both occupancies types, which reflect the variations on the thermal performance considering the local climate, building typology, chosen construction material and studied occupancies. This analysis generates an index named IDTR Thermal Performance Resultant Index, which was configured as a thermal performance rating system. It correlates the thermal performance with the number of hours that the indoor air temperature was on each of the six thermal comfort bands pre-defined that received weights to measure the discomfort intensity. The use of this rating system showed to be appropriated when used in one of the simulated cases, presenting advantages in relation to other evaluation methods and becoming a tool for the understanding of building thermal behavior

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present research concerns about outdoor s thermal comfort conditions in hot-humid climate cities, understanding that life quality is a result of the urban object s type built for the human being in an environment with specific climate and morphological characteristics. It is presented as object of study the correlation between the neighborhood Renascença II s microclimate in São Luis /MA-Brazil, hot-humid climate city, and its urban morphological changes. As well as the thermal comfort s satisfaction level of its outdoor users. The research has as general goal to diagnosis the way these transformations caused by the urbanization influence the Renascença II s microclimate, identifying critical spots of the studied area, in order to contribute with land use recommendations based on bioclimatic architecture concepts and supply bases to urban design decisions adequate to the São Luis climate. It is presented as theoretical bases the urban climate, its concepts and elements. After that, the thermal comfort conditioners and its prediction models of thermal comfort sensation in outdoor are presented. The predictive models are presented along with bioclimatic assessment methods. Finally the use of bioclimatic assessment as an effective tool to identify places that need changes or preservation in order to seek environment quality. The applied methodology was based on the studies of Katzschner (1997), complemented by Oliveira s (1988) and Bustos Romero s (2001) studies that suggest an analysis and evaluation of maps of topography, buildings floors, land use, green areas and land covering, in order to overlap their characteristics and identify climate variable s measurements points; then a quantitative analysis of the climate variables (air temperature and humidity, wind speed and direction) of the chosen points takes place. It was perceived that Renaissance II has no permanence areas as squares or parks, its outdoor has little vegetation and presets high land impermeability and built density levels. The majority of the people interviewed said that was comfortable in a range of air temperature between 27,28ºC and 30,71ºC. The elaboration of a neighborhood master plan is important, which defines strategies for improvement of the life quality of its inhabitants

Relevância:

20.00% 20.00%

Publicador:

Resumo:

No panorama energético atual, medidas de desenvolvimento sustentável têm uma preponderância cada vez mais significativa e, sendo os edifícios responsáveis por 40% da energia consumida na EU, enquadra-se o desafio de integrar medidas de eficiência energética nos novos edifícios desde a fase de conceção. Sendo que este setor se encontra em contínua expansão, a redução dos consumos passará largamente pela otimização do comportamento térmico dos edifícios e dos sistemas energéticos que os equipam. No presente trabalho estudou-se o papel da inércia térmica na redução das necessidades de energia para climatização de edifícios com o objetivo de identificar estratégias destinadas ao melhoramento do comportamento térmico e desempenho energético de edifícios construídos com recurso à técnica construtiva LSF, caracterizados por uma fraca inércia térmica quando comparados com edifícios em tudo semelhantes mas construídos recorrendo a tecnologias convencionais sem esquecer as questões relacionadas com a respetiva viabilidade económica. Com resultado geral destaca-se desde logo a importância do local onde é mais benéfico adicionar massa térmica (paredes exteriores, cobertura, paredes interiores), assim como a necessidade de utilização de um material com elevada densidade energética e baixo custo. A análise comparativa dos diferentes modelos de edifício simulados com recurso ao software DesignBuilder/EnergyPlus, foi realizada recorrendo a uma metodologia em que cada modelo construtivo é avaliado considerando quatro níveis de isolamento térmico e duas condições de cargas térmicas internas. A análise energética e económica foi realizada tendo como referência um período de 20 anos. O custo das soluções construtivas foi maioritariamente obtido através da ferramenta computacional Gerador de Preços, da Cype, SA©, tendo-se considerado um consumo energético anual constante e igual às necessidades de climatização anuais, assim como taxas de atualização de capital e de inflação do custo da energia constantes. De uma forma geral conclui-se que edifícios do tipo LSF melhorados através da adição criteriosa de massa térmica em determinados elementos construtivos, apresentam necessidades de climatização anuais na maioria dos casos estudados, inferiores àquelas verificadas em edifícios convencionais com inércia térmica média/forte. Conclui-se, também, que o método construtivo LSF se apresenta mais eficaz em termos energéticos e económicos quando comparado com soluções semelhantes construídas com recurso a um método convencional. Na secção seguinte são identificadas as principais conclusões deste trabalho.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This Masters Degree dissertation seeks to make a comparative study of internal air temperature data, simulated through the thermal computer application DesignBuilder 1.2, and data registered in loco through HOBO® Temp Data Logger, in a Social Housing Prototype (HIS), located at the Central Campus of the Federal University of Rio Grande do Norte UFRN. The prototype was designed and built seeking strategies of thermal comfort recommended for the local climate where the study was carried out, and built with panels of cellular concrete by Construtora DoisA, a collaborator of research project REPESC Rede de Pesquisa em Eficiência Energética de Sistemas Construtivos (Research Network on Energy Efficiency of Construction Systems), an integral part of Habitare program. The methodology employed carefully examined the problem, reviewed the bibliography, analyzing the major aspects related to computer simulations for thermal performance of buildings, such as climate characterization of the region under study and users thermal comfort demands. The DesignBuilder 1.2 computer application was used as a simulation tool, and theoretical alterations were carried out in the prototype, then they were compared with the parameters of thermal comfort adopted, based on the area s current technical literature. Analyses of the comparative studies were performed through graphical outputs for a better understanding of air temperature amplitudes and thermal comfort conditions. The data used for the characterization of external air temperature were obtained from the Test Reference Year (TRY), defined for the study area (Natal-RN). Thus the author also performed comparative studies for TRY data registered in the years 2006, 2007 and 2008, at weather station Davis Precision Station, located at the Instituto Nacional de Pesquisas Espaciais INPE-CRN (National Institute of Space Research), in a neighboring area of UFRN s Central Campus. The conclusions observed from the comparative studies performed among computer simulations, and the local records obtained from the studied prototype, point out that the simulations performed in naturally ventilated buildings is quite a complex task, due to the applications limitations, mainly owed to the complexity of air flow phenomena, the influence of comfort conditions in the surrounding areas and climate records. Lastly, regarding the use of the application DesignBuilder 1.2 in the present study, one may conclude that it is a good tool for computer simulations. However, it needs some adjustments to improve reliability in its use. There is a need for continued research, considering the dedication of users to the prototype, as well as the thermal charges of the equipment, in order to check sensitivity

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The assessment of building thermal performance is often carried out using HVAC energy consumption data, when available, or thermal comfort variables measurements, for free-running buildings. Both types of data can be determined by monitoring or computer simulation. The assessment based on thermal comfort variables is the most complex because it depends on the determination of the thermal comfort zone. For these reasons, this master thesis explores methods of building thermal performance assessment using variables of thermal comfort simulated by DesignBuilder software. The main objective is to contribute to the development of methods to support architectural decisions during the design process, and energy and sustainable rating systems. The research method consists on selecting thermal comfort methods, modeling them in electronic sheets with output charts developed to optimize the analyses, which are used to assess the simulation results of low cost house configurations. The house models consist in a base case, which are already built, and changes in thermal transmittance, absorptance, and shading. The simulation results are assessed using each thermal comfort method, to identify the sensitivity of them. The final results show the limitations of the methods, the importance of a method that considers thermal radiance and wind speed, and the contribution of the chart proposed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to compare the thermal performance of tiles made from recycled material (waste packaging cardboard with aluminized film) with the tiles of fiber and bitumen, fiber cement and red ceramic with the aim of verifying the suitability of tile to be used in hot and humid climate of low latitude. The samples were selected according to the availability from Natal - RN market, as they are sold to the consumers. The methodology was based on studies that used experimental apparatus composed of thermal chambers heated by banks of incandescent bulbs, to analyze the thermal performance of materials. The tiles in the study were submitted to analysis of thermal performance, thermophysical properties and absorptance, using chambers of thermal performance, measuring the thermophysical properties and portable spectrometer, respectively. Comparative analysis of thermal performance between two samples of the recycled material with dimple sizes and different amounts of aluminum were made, in order to verify, if these characteristics had some interference on the thermal performance of them; the results showed no significant performance differences between the samples. The data obtained in chambers of thermal performance and confirmed by statistical analysis, showed, that the tile of recycled material have similar thermal performance to the tile of fiber cement. In addition to these tests was carried out the automatic monitoring of a building covered with tiles of recycled material, to verify its thermal performance in a real situation. The results showed that recycled shingles must be used with technical criteria similar to those used for fiber cement tiles, with regard to the heat gain into the building. Within these criteria should be taken into account local characteristics, especially in regions with hot and humid climate, and its use must be associated, according to the literature, to elements of thermal insulation and use of passive techniques such as vented attics, ceilings and right foot higher