786 resultados para Assisted Fracture


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrically assisted bicycles (EAB) are flourishing in cities throughout the world and capitalize on ecological and practical advantages, helping in the fight against pollution, CO2 emissions and traffic jam. Human power is necessary to activate the electrical support, so that it equals to a moderate intensity physical activity (> 3 MET), or a vigorous one on hilly courses (>6 MET). The ecological benefits are obvious and transportation departments tend to support citizens who purchase one. EAB offer increased mobility at speeds of 15 to 25 km/h depending on hills and fitness of the rider, but could cause more accidents. EAB is linked to a real physical activity beneficial for health, but potentially more dangerous than a traditional bicycle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Changes in bone mineral density and bone strength following treatment with zoledronic acid (ZOL) were measured by quantitative computed analysis (QCT) or dual-energy X-ray absorptiometry (DXA). ZOL treatment increased spine and hip BMD vs placebo, assessed by QCT and DXA. Changes in trabecular bone resulted in increased bone strength. INTRODUCTION: To investigate bone mineral density (BMD) changes in trabecular and cortical bone, estimated by quantitative computed analysis (QCT) or dual-energy X-ray absorptiometry (DXA), and whether zoledronic acid 5 mg (ZOL) affects bone strength. METHODS: In 233 women from a randomized, controlled trial of once-yearly ZOL, lumbar spine, total hip, femoral neck, and trochanter were assessed by DXA and QCT (baseline, Month 36). Mean percentage changes from baseline and between-treatment differences (ZOL vs placebo, t-test) were evaluated. RESULTS: Mean between-treatment differences for lumbar spine BMD were significant by DXA (7.0%, p < 0.01) and QCT (5.7%, p < 0.0001). Between-treatment differences were significant for trabecular spine (p = 0.0017) [non-parametric test], trabecular trochanter (10.7%, p < 0.0001), total hip (10.8%, p < 0.0001), and compressive strength indices at femoral neck (8.6%, p = 0.0001), and trochanter (14.1%, p < 0.0001). CONCLUSIONS: Once-yearly ZOL increased hip and spine BMD vs placebo, assessed by QCT vs DXA. Changes in trabecular bone resulted in increased indices of compressive strength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To assess the incremental cost-effectiveness ratio (ICER) and incremental cost-utility ratio (ICUR) of risedronate compared to no intervention in postmenopausal osteoporotic women in a Swiss perspective. METHODS: A previously validated Markov model was populated with epidemiological and cost data specific to Switzerland and published utility values, and run on a population of 1,000 women of 70 years with established osteoporosis and previous vertebral fracture, treated over 5 years with risedronate 35 mg weekly or no intervention (base case), and five cohorts (according to age at therapy start) with eight risk factor distributions and three lengths of residual effects. RESULTS: In the base case population, the ICER of averting a hip fracture and the ICUR per quality-adjusted life year gained were both dominant. In the presence of a previous vertebral fracture, the ICUR was below euro45,000 (pound30,000) in all the scenarios. For all osteoporotic women>or=70 years of age with at least one risk factor, the ICUR was below euro45,000 or the intervention may even be cost saving. Age at the start of therapy and the fracture risk profile had a significant impact on results. CONCLUSION: Assuming a 2-year residual effect, that ICUR of risedronate in women with postmenopausal osteoporosis is below accepted thresholds from the age of 65 and even cost saving above the age of 70 with at least one risk factor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Between January 1996 and July 2003, 93 consecutive patients operated on with a diagnosis of olecranon fractures were identified from our trauma unit files. Fourteen transolecranon fracture-dislocations were found after a retrospective X-radiographic evaluation. Eight patients were women and six were men, with a mean age of 54 years. There were 4 noncomminuted olecranon fractures, treated with K-wires and single tension-band wiring. The remaining 10 fractures were complex fractures, treated in 3 cases with multiple K-wires and single tension-band wiring, in 2 by use of one-third tubular plates, in 1 with a 3.5-mm dynamic compression plate, and in the remaining 4 with 3.5-mm reconstruction plates. Ligament repair was not performed in any case. Three patients needed reoperation because of early failure of primary fixation. Patients were reviewed at a mean follow-up of 3.6 years. Two reported difficulties in daily activities, none with any symptoms of elbow instability. According to the Broberg and Morrey score, 4 patients had excellent results, 6 had good results, 2 had fair results, and 2 had poor results. Four patients showed signs of degenerative arthritis on the radiographs obtained at follow-up. We conclude that transolecranon fracture-dislocation is an underreported and misdiagnosed injury. Various fixation techniques can restore the anatomic relationships and contour of the trochlear notch; the imperative goal is to obtain a good stable primary fixation and allow early active mobilization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

After foot and/or ankle fracture, the restoration of optimal gait symmetry is one of the criteria of recovery. Orthotic insoles and orthopaedic shoes improve gait symmetry and regularity by controlling joint motion and improving alignment. The aim of the present study was to assess the effect of prescription footwear on gait quality by using accelerometers attached to the lower back. Sixteen adult patients with persistent disability after ankle and/or foot fractures performed two 30-s walking trials with and without prescription footwear (insoles and stabilizing shoes). Sixteen control subjects were also tested for comparison. The autocorrelation function was computed from the acceleration signal and the first two dominant periods were assessed (d1 and d2). Two parameters were used: (1) Stride Regularity (SR) which expresses the similarity between strides over time (d2), and (2) Stride Symmetry (SS) a ratio (d1/d2) which expresses the left/right similarity of gait independently of repeatability in the successive movements of each limb. In control subjects, SR and SS were 0.86+/-0.05 (correlation coefficient) and 81+/-10%, respectively. In the patient group, the effect of footwear was significant (SR: 0.88+/-0.06 vs. 0.90+/-0.05, SS: 38+/-23% vs. 46+/-27%). Pain was also significantly reduced (-34%). By using a rapid and low-cost method, we objectively quantified gait quality improvement after footwear intervention, concomitant to pain reduction. Substantial inter-patient variability in the footwear outcome was observed. In conclusion, we believe that trunk accelerometry can be a useful tool in the field of gait rehabilitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: This study is a single-institution validation of video-assisted thoracoscopic (VATS) resection of a small solitary pulmonary nodule (SPN) previously localized by a CT-guided hook-wire system in a consecutive series of 45 patients. METHODS: The records of all patients undergoing VATS resection for SPN preoperatively localized by CT-guided a hook-wire system from January 2002 to December 2004 were assessed with respect to failure to localize the lesion by the hook-wire system, conversion thoracotomy rate, duration of operation, postoperative complications, and histology of SPN. RESULTS: Forty-five patients underwent 49 VATS resections, with simultaneous bilateral SPN resection performed in 4. Preoperative CT-guided hook-wire localization failed in two patients (4%). Conversion thoracotomy was necessary in two patients (4%) because it was not possible to resect the lesion by a VATS approach. The average operative time was 50 min. Postoperative complications occurred in 3 patients (6%), one hemothorax and two pneumonia. The mean hospital stay was 5 days (range: 2-18 days). Histological assessment revealed inflammatory disease in 17 patients (38%), metastasis in 17 (38%), non-small-cell lung cancer (NSCLC) in 4 (9%), lymphoma in 3 (6%), interstitial fibrosis in 2 (4%), histiocytoma in one (2%), and hamartoma in one (2%). CONCLUSIONS: Histological analysis of resected SPN revealed unexpected malignant disease in more than 50% of the patients indicating that histological clarification of SPN seems warranted. Video-assisted thoracoscopic resection of SPN previously localized by a CT-guided hook-wire system is related to a low conversion thoracotomy rate, a short operation time, and few postoperative complications, and it is well suited for the clarification of SPN.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a high‐resolution electron microscopy study of the microstructure of boron nitride thin films grown on silicon (100) by radio‐frequency plasma‐assisted chemical vapor deposition using B2H6 (1% in H2) and NH3 gases. Well‐adhered boron nitride films grown on the grounded electrode show a highly oriented hexagonal structure with the c‐axis parallel to the substrate surface throughout the film, without any interfacial amorphous layer. We ascribed this textured growth to an etching effect of atomic hydrogen present in the gas discharge. In contrast, films grown on the powered electrode, with compressive stress induced by ion bombardment, show a multilayered structure as observed by other authors, composed of an amorphous layer, a hexagonal layer with the c‐axis parallel to the substrate surface and another layer oriented at random

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The substrate tuning technique was applied to a radio frequency magnetron sputtering system to obtain a variable substrate bias without an additional source. The dependence of the substrate bias on the value of the external impedance was studied for different values of chamber pressure, gas composition and rf input power. A qualitative explanation of the results is given, based on a simple model, and the role of the stray capacitance is clearly disclosed. Langmuir probe measurements show that this system allows independent control of the ion flux and the ion energy bombarding the growing film. For an argon flow rate of 2.8 sccm and a radio frequency power of 300 W (intermediate values of the range studied) the ion flux incident on the substrate was 1.3 X 1020-m-2-s-1. The maximum ion energy available in these conditions can be varied in the range 30-150 eV. As a practical application of the technique, BN thin films were deposited under different ion bombardment conditions. An ion energy threshold of about 80 eV was found, below which only the hexagonal phase was present in the films, while for higher energies both hexagonal and cubic phase were present. A cubic content of about 60% was found for an ion energy of 120 V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This case-control study assessed whether the trabecular bone score (TBS), determined from gray-level analysis of DXA images, might be of any diagnostic value, either alone or combined with bone mineral density (BMD), in the assessment of vertebral fracture risk among postmenopausal women with osteopenia. Of 243 postmenopausal Caucasian women, 50-80 years old, with BMD T-scores between -1.0 and -2.5, we identified 81 with osteoporosis-related vertebral fractures and compared them with 162 age-matched controls without fractures. Primary outcomes were BMD and TBS. For BMD, each incremental decrease in BMD was associated with an OR = 1.54 (95% CI = 1.17-2.03), and the AUC was 0.614 (0.550-0.676). For TBS, corresponding values were 2.53 (1.82-3.53) and 0.721 (0.660-0.777). The difference in the AUC for TBS vs. BMD was statistically significant (p = 0.020). The OR for (TBS + BMD) was 2.54 (1.86-3.47) and the AUC 0.732 (0.672-0.787). In conclusion, the TBS warrants a closer look to see whether it may be of clinical usefulness in the determination of fracture risk in postmenopausal osteopenic women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé : Introduction : L'objectif de cette étude était d'une part d'évaluer les caractéristiques histologiques des fragments cellulaires rétiniens attachés à la limitante interne après vitrectomie et pelage d'une membrane epirétinienne, et d'autre part de mettre en évidence des différences histologiques entre les cas opérés avec ou sans l'aide d'ICG dilué dans du glucose 5%. Méthodes Nous avons examiné rétrospectivement l'histologie de 88 spécimens de membranes épimaculaires contenant la limitante interne de la rétine, qui ont été enlevés chirurgicalement entre 1995 et 2003. L'analyse histologique a centré principalement l'attention sur la présence et les caractéristiques des fragments cellulaires rétiniens attachés à la limitante interne. L'analyse statistique a comparé les résultats entre le groupe I (chirurgie conventionnelle sans l'aide de l'ICG) et le groupe II (chirurgie à l'aide de l'ICG). Résultats Soixante et onze patients ont eu une vitrectomie sans l'aide de l'ICG (groupe I) et 17 avec l'aide de l'ICG (groupe II). Le nombre de débris de cellules de Müller à la surface rétinienne de la limitante interne était plus important dans le groupe I (sans ICG) que dans le groupe II (avec ICG) (40.8% versus 11.8% ; p = 0.024). Des larges fragments cellulaires rétiniens attachés à la limitante interne ont été plus fréquemment observés dans le groupe I (sans ICG) que dans le groupe II (avec ICG) (63.4% versus 23.5%; p= 0.003). Dans cinq (7%) cas du groupe I, de gros éléments cellulaires rétiniens ont été mis en évidence (des axones neuraux ou des vaisseaux sanguins). De tels éléments n'ont pas été retrouvés dans les spécimens du groupe II (avec ICG). Conclusions L'utilisation de l'ICG dilué dans du glucose 5% pour faciliter le pelage d'une membrane épimaculaire et notamment l'ablation de la limitante interne de la rétine semble diminuer de manière significative le nombre et la taille des débris des cellules de Muller adhérents à la face rétinienne de la membrane limitante interne de la rétine. Cette observation suggère que l'utilisation per-opératoire d'ICG dilué dans du glucose 5% facilite l'ablation de la limitante interne pendant la chirurgie de la membrane epirétinienne en diminuant l'adhérence de la limitante interne à la rétine.