1000 resultados para Aquecimento por microondas
Resumo:
Epoxy based nanocomposites with 1 wt % and 3 wt % of nanographite were processed by high shear mixing. The nanographite was obtained by chemical (acid intercalation), thermal (microwave expansion) and mechanical (ultrasonic exfoliation) treatments. The mechanical, electrical and thermal behavior of the nanocomposites was determined and evaluated as a function of the percentage of reinforcement. According to the experimental results, the electrical conductivity of epoxy was not altered by the addition of nanographite in the contents evaluated. However, based on the mechanical tests, nanocomposites with addition of 1 wt.% and 3 wt.% of nanographite showed increase in tensile strength of 16,62 % and 3,20 %, respectively, compared to the neat polymer. The smaller increase in mechanical strength of the nanocomposite with 3 wt.% of nanographite was related to the formation of agglomerates. The addition of 1 wt.% and 3 wt.% of nanographite also resulted in a decrease of 6,25 % and 17,60 %, respectively, in the relative density of the material. Thus, the specific strength of the nanocomposites was approximately 33,33 % greater when compared to the neat polymer. The addition of 1 wt.% and 3 wt.% of nanographite in the material increased the mean values of thermal conductivity in 28,33 % and 132,62 %, respectively, combined with a reduction of 26,11 % and 49,80 % in volumetric thermal capacity, respectively. In summary, it has been determined that an addition of nanographite of the order of 1 wt.% and 3 wt.% produced notable elevations in specific strength and thermal conductivity of epoxy
Resumo:
Heating rate is one of the main variables that determine a fire cycle. In industrial processes that use high temperatures, greater fire great can reduce the cost of production and increase productivity. The use of faster and more efficient fire cycles has been little investigated by the structural ceramic industry in Brazil. However, one of the possibilities that aims at modernizing the sector is the use of roller kilns and the inclusion of natural gas as fuel. Thus, the purpose of this study is to investigate the effect of heating rate on the technological properties of structural ceramic products. Clay raw materials from the main ceramic industries in the state of Rio Grande do Norte were characterized. Some of the raw materials characterized were formulated to obtain the best physical and mechanical properties. Next, raw materials and formulations were selected to study the influence of heating rate on the final properties of the ceramic materials. The samples were shaped by pressing and extrusion and submitted to rates of 1 °C/min, 10 °C/min and 20 °C/min, with final temperatures of 850 °C, 950 °C and 1050 °C. Discontinuous cycles with rates of 10 °C/min or 15 °C/min up to 600 °C and a rate of 20 °C/min up to final temperature were also investigated. Technological properties were determined for all the samples and microstructural analysis was carried out under a number of fire conditions. Results indicate that faster and more efficient fire cycles than those currently in practice could be used, limiting only some clay doughs to certain fire conditions. The best results were obtained for the samples submitted to slow cycles up to 600 °C and fast fire sinterization up to 950 °C. This paper presents for the first time the use of a fast fire rate for raw materials and clay formulations and seeks to determine ideal dough and processing conditions for using shorter fire times, thus enabling the use of roller kilns and natural gas in structural ceramic industries
Resumo:
Electrical resistive heating (ERH) is a thermal method used to improve oil recovery. It can increase oil rate and oil recovery due to temperature increase caused by electrical current passage through oil zone. ERH has some advantage compared with well-known thermal methods such as continuous steam flood, presenting low-water production. This method can be applied to reservoirs with different characteristics and initial reservoir conditions. Commercial software was used to test several cases using a semi-synthetic homogeneous reservoir with some characteristics as found in northeast Brazilian basins. It was realized a sensitivity analysis of some reservoir parameters, such as: oil zone, aquifer presence, gas cap presence and oil saturation on oil recovery and energy consumption. Then it was tested several cases studying the electrical variables considered more important in the process, such as: voltage, electrical configurations and electrodes positions. Energy optimization by electrodes voltage levels changes and electrical settings modify the intensity and the electrical current distribution in oil zone and, consequently, their influences in reservoir temperature reached at some regions. Results show which reservoir parameters were significant in order to improve oil recovery and energy requirement in for each reservoir. Most significant parameters on oil recovery and electrical energy delivered were oil thickness, presence of aquifer, presence of gas cap, voltage, electrical configuration and electrodes positions. Factors such as: connate water, water salinity and relative permeability to water at irreducible oil saturation had low influence on oil recovery but had some influence in energy requirements. It was possible to optimize energy consumption and oil recovery by electrical variables. Energy requirements can decrease by changing electrodes voltages during the process. This application can be extended to heavy oil reservoirs of high depth, such as offshore fields, where nowadays it is not applicable any conventional thermal process such as steam flooding
Resumo:
This project describes a methodology optimization that would allow for a more efficient microwave assisted digestion process for petroleum samples. With the possible chance to vary various factors at once to see if any one factor was significant enough in the answers, experimental planning was used. Microwave assisted digestion allows, through the application of potency, an increasing number of collisions between the HNO3 and H2O2 molecules, favoring sample opening for complex matrixes. For this, a 24 factorial experimental planning was used, varying potency, time and the volumes for HNO3 65% and H2O2 30%. To achieve the desired answers, several elements were monitored (C, Cu, Cr, Fe, Ni, Zn and V) through Inductively coupled plasma atomic emission spectroscopy (ICP-OES). With this initial study it was noticed that the HNO3 was not a significant factor for any of the statistical studies for any of the analytes and the other 3 factors and their interactions showed statistical significance. A Box Behnken experimental planning was used taking in consideration 3 factors: H2O2 volume, time (min) and Potency (W), Nitric Acid kept at 4mL for a mass of 0,1g of petroleum. The results were extremely satisfying showing higher efficiency in the digestion process and taking in a responsibility between the answers for each analyte and the carbon monitoring was achieved in the following conditions: 7mL of H2O2, 700 Watts of potency and a reaction time of 7 minutes with 4mL de HNO3 for a mass of 0,1g of petroleum. The optimized digestion process was applied to four different petroleum samples and the analytes determined by ICP-OES
Resumo:
Antecedentes y objetivos: La hiperhidrosis primaria afecta el 2,8% de la población de Estados Unidos. Condición que impacta el desarrollo social de los individuos afectados, ocasionando fobia social. Existen opciones disponibles para el tratamiento de la hiperhidrosis incluyendo medicamentos tópico, sistémico, inyectable y quirúrgico. El objetivo de ésta revisión sistemática de la literatura es determinar la efectividad y seguridad de los dispositivos de emisión de microondas, radiofrecuencia no ablativa y sistema de ultrasonido microfocalizado para el tratamiento de la hiperhidrosis primaria. Materiales y métodos: Se realizó una revisión sistemática de la literatura de artículos obtenidos de bases de datos: Medline, Cochrane, Embase, Ovid y Scielo. Se incluyeron ensayos clínicos aleatorizados controlados, ensayos cuasiexperimentales desde el 2011; donde evaluaran el uso de estos dispositivos en el manejo de hiperhidrosis primaria. Resultados: Se seleccionaron 21 artículos en total. Se encontró que con los tres dispositivos se logra una reducción significativa a puntajes entre 1 y 2 de la escala de Severidad de la Hiperhidrosis; en 3 estudios se encontró mejoría en la calidad de vida; los eventos adversos fueron transitorios, siendo más frecuentes con el dispositivo de emisión de microondas. Conclusión: Primera revisión sistemática de la literatura sobre el efecto de estos tres dispositivos en el manejo de hiperhidrosis. Se espera aportar a la literatura existente una recomendación acerca de la efectividad y seguridad de estos dispositivos para que sea aplicado en los pacientes con diagnóstico de hiperhidrosis primaria.
Resumo:
An alternative proposal for floor heating system by means of electric resistance for both chick and piggy installation is presented in this work. Several formulations of rice husk and cement mortar boards were used. An electronic device controlled all board temperature. This system presented a good efficiency design. The conventional cement mortar mixed with rice husk showed a better performance.
Resumo:
Air quality in animal production environment has been refereed as an interesting point for studies in environmental control systems with the focus both to the animal health which live in total confinement, as to the workers. The objective of this research was to determine the variation on the aerial environmental quality in two types of broiler housing: conventional (Gc) and tunnel type (Gt). The total dust values in both houses offered adequate rearing conditions to the birds; however, regarding the inhale dust in the air was above the limits recommended for humans. Carbon monoxide concentration in the heating phase during the evaluated period was above the 10 ppm maximum recommended, and it was higher during the cold season in Gt house (30 ppm) when compared to the Gc house (18 ppm). Ammonia concentration peaks in the air were above the 20 ppm recommended from the 20th day of production in both houses and in daily average, for a period higher in Gt (4h30) when compared to Gt (2h45). Only traces of nitrate oxide and methane were found while carbonic dioxide gas concentration evaluated during daytime met the limits allowed for both birds and labor.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
This study evaluated the color stability, surface roughness and flexural strength of a microwave-polymerized acrylic resin after immersion in sodium hypochlorite (NaOCl), simulating 20 min of disinfection daily during 180 days. Forty disk-shaped (15 x 4 mm) and 40 rectangular (65 x 10 x 3 mm) specimens were prepared with a microwave-polymerized acrylic resin (Onda-Cryl). Specimens were immersed in either 0.5% NaOCl, 1% NaOCl, Clorox/Calgon and distilled water (control). Color measurements were determined by a portable colorimeter. Three parallel lines, separated by 1.0 mm, were registered on each specimen before and after immersion procedures to analyze the surface roughness. The flexural strength was measured using a 3-point bending test in a universal testing machine with a 50 kgf load cell and a crosshead speed of 1 mm/min. Data were analyzed statistically by ANOVA and Tukey's test (?=0.05). There was no statistically significant differences (p>0.05) among the solutions for color, surface roughness and flexural strength. It may be concluded that immersion in NaOCl solutions simulating short-term daily use during 180 days did not influence the color stability, surface roughness and flexural strength of a microwave-polymerized acrylic resin.
Resumo:
The present study evaluated the effect of repeated simulated microwave disinfection on physical and mechanical properties of Clássico, Onda-Cryl and QC-20 denture base acrylic resins. Aluminum patterns were included in metallic or plastic flasks with dental stone following the traditional packing method. The powder/liquid mixing ratio was established according to the manufacturer's instructions. After water-bath polymerization at 74ºC for 9 h, boiling water for 20 min or microwave energy at 900 W for 10 min, the specimens were deflasked after flask cooling and finished. Each specimen was immersed in 150 mL of distilled water and underwent 5 disinfection cycles in a microwave oven set at 650 W for 3 min. Non-disinfected and disinfected specimens were subjected to the following tets: Knoop hardness test was performed with 25 g load for 10 s, impact strength test was done using the Charpy system with 40 kpcm, and 3-point bending test (flexural strength) was performed at a crosshead speed of 0.5 mm/min until fracture. Data were analyzed statistically by ANOVA and Tukey's test (α= 0.05%). Repeated simulated microwave disinfections decreased the Knoop hardness of Clássico and Onda-Cryl resins and had no effect on the impact strength of QC-20. The flexural strength was similar for all tested resins.
Resumo:
This in vitro study evaluated the temperature of dentures after different microwave irradiation protocols. Two complete dentures (one maxillary and one mandibular denture) were irradiated separately 4 times for each of the following 5 protocols: dentures immersed in water (G1- 6 min, G2- 3 min); dentures kept dry (G3- 6 min); dentures placed in the steam sterilizer (G4- 6 min, G5- 3 min). The final temperature of the dentures was gauged in a thin and in a thick area of each denture with an infrared thermometer. All groups presented an increase in the resin base temperature. The thin areas of the dentures underwent greater heating than the thick areas. There was no significant difference (p>0.05) between the final mean temperatures of dentures immersed in water for 6 (G1) and 3 min (G2). However, the final mean temperatures recorded in G1 and G2 exceeded 71°C and were significantly higher (<0.001) than the final mean temperatures recorded in the other groups. It may be concluded that denture base resins subjected to microwave irradiation immersed in water may be exposed to deleterious temperatures.
Resumo:
OBJETIVO: A hipotermia é prejudicial no período perioperatório. Não há consenso sobre o melhor método de aquecimento ativo e nem sobre o melhor período para fazê-lo. Este estudo teve como objetivo primário verificar a eficácia de diferentes períodos de utilização da manta térmica à temperatura de 38°C, como método de prevenção da hipotermia intraoperatória. Como objetivo secundário avaliou-se os efeitos adversos do uso da manta térmica na temperatura de 38°C. MÉTODOS: Foram comparados quatro grupos de 15 pacientes submetidos a operações ortopédicas. No grupo controle (Gcont) os pacientes não utilizaram manta térmica, nos grupos pré (Gpré), intra (Gintra) e total (Gtotal), os pacientes utilizaram manta térmica a 38ºC, respectivamente, durante 30 minutos antes da indução anestésica, após a indução anestésica até 120 minutos e antes e após a indução. Foram avaliados: temperatura central (timpânica), periférica (pele), da sala cirúrgica, variação das condições hemodinâmicas e efeitos adversos do aquecimento. RESULTADOS: O Gtotal foi o único grupo que não teve variação significativa da temperatura central. A temperatura central dos pacientes do grupo Gtotal foi significativamente maior (p <0,05) do que a dos outros grupos aos 60 e 120 min após a indução. Os pacientes dos grupos Gcont, Gpré e Gintra apresentaram hipotermia aos 60 min. CONCLUSÃO: O uso da manta térmica com fluxo de ar aquecido foi eficaz como método de prevenção da hipotermia intraoperatória quando foi empregada desde 30 min antes da indução anestésica até 120 min após o início da anestesia. Nas condições do estudo não ocorreram eventos adversos.
Resumo:
Na primeira semana de maio de 2008, durante quatro dias, um ciclone em superfície permaneceu semi-estacionário na costa da região sul do Brasil. Este sistema foi responsável por chuvas e ventos fortes no Rio Grande do Sul e Santa Catarina, os quais causaram muitos danos (queda de árvores, enchentes e desabamentos). O objetivo deste trabalho é avaliar o processo de formação e entender os mecanismos responsáveis pelo lento deslocamento do ciclone, já que a maioria dos ciclones nesta região possui deslocamento mais rápido. A equação de desenvolvimento de Sutcliffe mostrou que a advecção de vorticidade absoluta ciclônica na média troposfera e a advecção de ar quente na camada entre 1000-500 hPa foram mecanismos importantes para a ciclogênese. Neste período, o intenso aquecimento diabático também contribuiu para a ciclogênese, à medida que se contrapôs ao intenso resfriamento adiabático devido aos movimentos verticais ascendentes. A advecção de vorticidade absoluta ciclônica que favoreceu a ciclogênese esteve associada a um Vórtice Ciclônico em Altos Níveis (VCAN), que se formou numa região de anomalia de vorticidade potencial. O VCAN se manteve semi-estacionário e compôs o setor norte de um bloqueio do tipo dipolo. Tal bloqueio intensificou um anticiclone em superfície, situado a sul/leste do ciclone, o que contribuiu para o ciclone se manter semi-estacionário. O movimento atípico e lento do ciclone para sul, e em alguns períodos para sudoeste, esteve associado com advecções de vorticidade absoluta ciclônica na média troposfera e de ar quente no seu setor sul. Somente quando o bloqueio em níveis médios e a anomalia de vorticidade potencial em níveis médios/altos se enfraqueceram, o ciclone em superfície se afastou da costa sul do Brasil.
Resumo:
Neste trabalho estudou-se a influência dos padrões de onda extratropicais, que favorecem o desenvolvimento de eventos extremos frios no sudeste Sul-Americano, e em particular na região conhecida como Pampa Úmida. O aquecimento anômalo observado na região do oceano Pacífico tropical ocidental a nordeste da Austrália, durante os invernos de máxima freqüência de ocorrência de Geadas Generalizadas (GG) no centro-leste da Argentina, (região conhecida como Pampa Úmida - PU), atua como disparador de ondas de Rossby, as quais se propagam até o continente, favorecendo assim a ocorrência daqueles eventos. O padrão de propagação obtido nas simulações numéricas com um modelo baroclínico global, mostra o predomínio de um número de onda 3. Adicionalmente, foram analisadas as correlações do vento meridional em altos e baixos níveis observados para os eventos de GG, selecionados dentro dos invernos de máxima freqüência de ocorrência desses eventos. O vento meridional global em 250hPa apresenta regiões com correlação estatisticamente significativa com o vento meridional médio na PU. A configuração obtida no caso do vento meridional global em 250hPa, correlacionado com o vento meridional na PU, pode estar associada ao padrão de propagação das ondas simuladas numericamente a partir da forçante tropical. Igualmente importantes e significativos são os valores de correlação do vento sul nos baixos níveis, em particular para toda região da PU. O padrão de ondas simulado está bem representado pelas significativas correlações entre o vento meridional hemisférico em altos níveis e a temperatura no dia de evento de GG.
Resumo:
É apresentado um estudo sobre sistemas convectivos linearmente organizados e observados por um radar meteorológico banda-C na região semi-árida do Nordeste do Brasil. São analisados três dias (27 a 29) de março de 1985, com ênfase na investigação do papel desempenhado por fatores locais e de grande escala no desenvolvimento dos sistemas. No cenário de grande escala, a área de cobertura do radar foi influenciada por um cavado de ar superior austral no dia 27 e por um vórtice ciclônico de altos níveis no dia 29. A convergência de umidade próxima à superfície favoreceu a atividade convectiva nos dias 27 e 29, enquanto que divergência de umidade próxima à superfície inibiu a atividade convectiva no dia 28. No cenário de mesoescala, foi observado que o aquecimento diurno é um fator importante para a formação de células convectivas, somando-se a ele o papel determinante da orografia na localização dos ecos. De maneira geral, as imagens de radar mostram os sistemas convectivos linearmente organizados em áreas elevadas e núcleos convectivos intensos envolvidos por uma área de precipitação estratiforme. Os resultados indicam que convergência do fluxo de umidade em grande escala e aquecimento radiativo, são fatores determinantes na evolução e desenvolvimento dos ecos na área de estudo.