933 resultados para Angle of air injection
Resumo:
The present study focuses on two effects of the presence of a noncondensable gas on the thermal-hydraulic behavior of thecoolant of the primary circuit of a nuclear reactor in the VVER-440 geometry inabnormal situations. First, steam condensation with the presence of air was studied in the horizontal tubes of the steam generator (SG) of the PACTEL test facility. The French thermal-hydraulic CATHARE code was used to study the heat transfer between the primary and secondary side in conditions derived from preliminary experiments performed by VTT using PACTEL. In natural circulation and single-phase vapor conditions, the injection of a volume of air, equivalent to the totalvolume of the primary side of the SG at the entrance of the hot collector, did not stop the heat transfer from the primary to the secondary side. The calculated results indicate that air is located in the second half-length (from the mid-length of the tubes to the cold collector) in all the tubes of the steam generator The hot collector remained full of steam during the transient. Secondly, the potential release of the nitrogen gas dissolved in the water of the accumulators of the emergency core coolant system of the Loviisa nuclear power plant (NPP) was investigated. The author implemented a model of the dissolution and release ofnitrogen gas in the CATHARE code; the model created by the CATHARE developers. In collaboration with VTT, an analytical experiment was performed with some components of PACTEL to determine, in particular, the value of the release time constant of the nitrogen gas in the depressurization conditions representative of the small and intermediate break transients postulated for the Loviisa NPP. Such transients, with simplified operating procedures, were calculated using the modified CATHARE code for various values of the release time constant used in the dissolution and release model. For the small breaks, nitrogen gas is trapped in thecollectors of the SGs in rather large proportions. There, the levels oscillate until the actuation of the low-pressure injection pumps (LPIS) that refill the primary circuit. In the case of the intermediate breaks, most of the nitrogen gas is expelled at the break and almost no nitrogen gas is trapped in the SGs. In comparison with the cases calculated without taking into account the release of nitrogen gas, the start of the LPIS is delayed by between 1 and 1.75 h. Applicability of the obtained results to the real safety conditions must take into accountthe real operating procedures used in the nuclear power plant.
Resumo:
Tämän diplomityön tarkoituksena oli asentaa ja kehittää UPM-Kymmene Rauman tehtaiden PK2:lle luotettava ja toimiva ilmanläpäisyprofiilin mittaus. Työn tarkoituksena oli myös kartoittaa tietoja ilmanläpäisyprofiiliin vaikuttavista seikoista sekä mahdollisuuksista säätää ilmanläpäisyprofiilia. Lisäksi työn tavoitteena oli löytää toimiva menetelmä verrata online mitattua ilmanläpäisyprofiilia laboratoriossa mitattuun ilmanläpäisyprofiiliin online mittauksen luotettavuuden näkökulmasta. Työn aikana selvitettiin myös ilmanläpäisyprofiilin mittauksen mahdollisuutta superkalanteroidusta SC paperista. Työn kirjallisessa osassa käsiteltiin paperin huokoisuutta ja ilmanläpäisyä, huokoisuustasoon ja huokoisuus profiiliin vaikuttavia tekijöitä, ilmanläpäisevyyden merkitystä SC paperin valmistukselle ja SC paperin painettavuudelle sekä ilmanläpäisevyyden laboratorio- sekä online mittausta. Kirjallisessa osassa käsiteltiin myös Honeywellin uutta Poros ilmanläpäisysensoria. Työn kokeellisessa osassa tutkittiin ilmanläpäisyprofiilimittauksen luotettavuutta CD ja MD suunnassa sekä laboratorio- ja online-mittausten välisiä eroavaisuuksia ennen PK2 uusintaa. PK2 uusinnan jälkeen kokeellisessa osassa keskityttiin luotettavuuden varmentamiseen CD ja MD suunnassa sekä kartoittamaan tekijöitä, jotka aiheuttivat pieniä tasoeroja mittausten välillä. Mittaukset todettiin luotettaviksi ja niiden pohjalta suoritettiin mitattujen online profiilien välisiä vertailuja. Ilmanläpäisyprofiililla todettiin olevan positiivinen korrelaatio neliömassaprofiilin ja kosteusprofiilin kanssa sekä negatiivinen korrelaatio tuhkaprofiilin kanssa. PK2 uusinnan yhteydessä tehtiin koeajoja, jotka liittyivät laadunoptimointiin viira- ja puristinosalla. Koeajoissa tutkittujen asioiden lisäksi tutkittiin muutettujen parametrien vaikutusta ilmanläpäisyprofiiliin. Höyrylaatikon vaikutusta ilmanläpäisyprofiiliin tutkittiin säätöjen virityksen yhteydessä.
Resumo:
A photonic system has been developed that enables sensitive quantitative determination of reactive oxygen species (ROS) - mainly hydrogen peroxide (H2O2) - in aerosol samples such as airborne nanoparticles and exhaled air from patients. The detection principle relies on the amplification of the absorbance under multiple scattering conditions due to optical path lengthening [1] and [2]. In this study, the presence of cellulose membrane that acts as random medium into the glass optical cell considerably improved the sensitivity of the detection based on colorimetric FOX assay (FeII/orange xylenol). Despite the loss of assay volume (cellulose occupies 75% of cell volume) the limit of detection is enhanced by one order of magnitude reaching the value of 9 nM (H2O2 equivalents). Spectral analysis is performed automatically with a periodicity of 5 to 15 s, giving rise to real-time ROS measurements. Moreover, the elution of air sample into the collection chamber via a micro-diffuser (impinger) enables quantitative determination of ROS contained in or generated from airborne samples. As proof-of-concept the photonic ROS detection system was used in the determination of both ROS generated from traffic pollution and ROS contained in the exhaled breath as lung inflammation biomarkers.
Resumo:
Objective To describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and Methods In the period from June 2011 to May 2012, seven computed tomography-guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results In all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible.
Resumo:
The knowledge on the optics of fogbows is scarce, and their polarization characteristics have never been measured to our knowledge. To fill this gap we measured the polarization features of 16 fogbows during the Beringia 2005 Arctic polar research expedition by imaging polarimetry in the red, green and blue spectral ranges. We present here the first polarization patterns of the fogbow. In the patterns of the degree of linear polarization p, fogbows and their supernumerary bows are best visible in the red spectral range due to the least dilution of fogbow light by light scattered in air. In the patterns of the angle of polarization α fogbows are practically not discernible because their α-pattern is the same as that of the sky: the direction of polarization is perpendicular to the plane of scattering and is parallel to the arc of the bow, independently of the wavelength. Fogbows and their supernumeraries were best seen in the patterns of the polarized radiance. In these patterns the angular distance δ between the peaks of the primary and the first supernumerary and the angular width σ of the primary bow were determined along different radii from the center of the bow. δ ranged between 6.08° and 13.41° , while σ changed from 5.25° to 19.47° . Certain fogbows were relatively homogeneous, meaning small variations of δ and σ along their bows. Other fogbows were heterogeneous, possessing quite variable δ- and σ-values along their bows. This variability could be a consequence of the characteristics of the high Arctic with open waters within the ice shield resulting in the spatiotemporal change of the droplet size within the fog
Resumo:
This work describes a lumped parameter mathematical model for the prediction of transients in an aerodynamic circuit of a transonic wind tunnel. Control actions to properly handle those perturbations are also assessed. The tunnel circuit technology is up to date and incorporates a novel feature: high-enthalpy air injection to extend the tunnels Reynolds number capability. The model solves the equations of continuity, energy and momentum and defines density, internal energy and mass flow as the basic parameters in the aerodynamic study as well as Mach number, stagnation pressure and stagnation temperature, all referred to test section conditions, as the main control variables. The tunnel circuit response to control actions and the stability of the flow are numerically investigated. Initially, for validation purposes, the code was applied to the AWT ("Altitude Wind Tunnel" of NASA-Lewis). In the sequel, the Brazilian transonic wind tunnel was investigated, with all the main control systems modeled, including injection.
Resumo:
Several aspects of nutrient cycling were studied at two sites of Atlantic Forest, in São Paulo State, Southeast Brazil (23o46 S; 46o18 W), which exhibited different degrees of forest structure decline caused by the air pollution emitted by the industrial complex of Cubatão, being referred here as the most and least affected sites (MAS and LAS, respectively). These investigations were developed during 1984 - 1986, a period in which the most severe negative effects of air pollution could be observed. Concentrations and amounts of N, P, K, Ca, Mg and S in four ecosystem compartments (leaves, litter layer, soil and roots) and in rainfall, throughfall and litterfall are briefly presented. At each site, the content of mineral elements generally decreased from leaves to litterfall and litter layer on the forest floor. Soil surface layer (0 - 5 cm) in both sites was the richest in mineral elements. Soil fertility was greater at LAS. In general, nutrient amounts remaining in the compartments and cycling through the ecosystem were greater at LAS as well, which could be due to the higher complexity of the forest structure at this site. Rainfall contributed more to soil inputs of K, Ca, Mg and S than litterfall at both sites. The nutrient residence times in the litter layer were higher and the index of nutrient use efficiency was lower at the most affected site. It was concluded that nutrient cycling was disturbed by air pollution at both sites, but to a greater extent at MAS. The main consequences of the air pollution stress were detected in the flux of nutrients through litterfall and in the litter layer on the forest floor.
Resumo:
In this study we investigated the effects of the injection into the supraoptic nucleus (SON) of non-peptide AT1- and AT2-angiotensin II (ANG II) receptor antagonists, DuP753 and PD123319, as well as of the arginine-vasopressin (AVP) receptor antagonist d(CH2)5-Tyr(Me)-AVP, on water and 3% NaCl intake induced by the injection of ANG II into the medial septal area (MSA). The effects on water or 3% NaCl intake were assessed in 30-h water-deprived or in 20-h water-deprived furosemide-treated adult male rats, respectively. The drugs were injected in 0.5 µl over 30-60 s. Controls were injected with a similar volume of 0.15 M NaCl. Antagonists were injected at doses of 20, 80 and 180 nmol. Water and sodium intake was measured over a 2-h period. Previous administration of the AT1 receptor antagonist DuP753 into the SON decreased water (65%, N = 10, P<0.01) and sodium intake (81%, N = 8, P<0.01) induced by the injection of ANG II (10 nmol) into the MSA. Neither of these responses was significantly changed by injection of the AT2-receptor antagonist PD123319 into the SON. On the other hand, while there was a decrease in water intake (45%, N = 9, P<0.01), ANG II-induced sodium intake was significantly increased (70%, N = 8, P<0.01) following injection of the V1-type vasopressin antagonist d(CH2)5-Tyr(Me)-AVP into the SON. These results suggest that both AT1 and V1 receptors within the SON may be involved in water and sodium intake induced by the activation of ANG II receptors within the MSA. Furthermore, they do not support the involvement of MSA AT2 receptors in the mediation of these responses.
Resumo:
The increasing use of alcohol as an alternative fuel to gasoline or diesel can increase emission of formaldehyde, an organic gas that is irritant to the mucous membranes. The respiratory system is the major target of air pollutants and its major defense mechanism depends on the continuous activity of the cilia and the resulting constant transportation of mucous secretion. The present study was designed to evaluate the effects of formaldehyde on the ciliated epithelium through a relative large dose range around the threshold limit value adopted by the Brazilian legislation, namely 1.6 ppm (1.25 to 5 ppm). For this purpose, the isolated frog palate preparation was used as the target of toxic injury. Four groups of frog palates were exposed to diluted Ringer solution (control, N = 8) and formaldehyde diluted in Ringer solution at three different concentrations (1.25, 2.5 and 5.0 ppm, N = 10 for each group). Mucociliary clearance and ciliary beat frequency decreased significantly in contact with formaldehyde at the concentrations of 2.5 and 5.0 ppm after 60 min of exposure (P<0.05). We conclude that relatively low concentrations of formaldehyde, which is even below the Brazilian threshold limit value, are sufficient to cause short-term mucociliary impairment.
Resumo:
Tämän työn tavoitteena oli hitsata tandem MAG –laitteistolla 25 mm paksua Ruukin E500 TMCP terästä. Työssä oli tarkoituksena vähentää railotilavuutta mahdollisimman paljon sekä suorittaa testihitsaukset 0.8 kJ/mm sekä 2.5 kJ/mm lämmöntuonneilla. Teoriaosuudessa käsiteltiin Tandem MAG-hitsaukseen, sen tuottavuuteen ja laatukysymyksiin liittyviä asioita sekä siinä perehdyttiin suurlujuusteräksien käyttöön hitsauksessa sekä laivanrakennuksessa. Kokeellisessa osuudessa perehdyttiin hitsauksessa huomattuihin etuihin, ongelmiin sekä ongelmien ratkaisumahdollisuuksiin. Hitsausliitoksen mekaaniset ominaisuudet tutkittiin rikkomattomin sekä rikkovin menetelmin. Alustavat hitsausohjeet luotiin kummallekin lämmöntuonnille. Testaukset aloitettiin 30 º railokulmalla pienentäen kulmaa mahdollisuuksien mukaan. Testauksissa ei saatu hitsattua onnistuneesti alle 30 º railokulmalla. Hitsaustestien aikana huomattiin magneettisen puhalluksen vaikutus hitsaustapahtumaan. Kaasunvirtausnopeuden tuli olla tietyn suuruinen jotta palkokerrokset onnistuivat ilman huokoisuusongelmaa. Pienemmällä lämmöntuonnilla hitsattaessa kaasunvirtausnopeudet olivat tärkeämpiä hitsatessa ylempiä palkokerroksia. Kääntämällä hitsauspoltinta sivuttaissuunnassa 7-10 astetta auttoi ehkäisemään reunahaavan syntymistä. Rikkovista menetelmistä testitulokset olivat hyväksyttyjä kaikkien muiden paitsi päittäishitsin sivutaivutuskokeen osalta.
Resumo:
The objective of the present study was to determine the impact of acute short-term exposure to air pollution on the cardiorespiratory performance of military fireman living and working in the city of Guarujá, São Paulo, Brazil. Twenty-five healthy non-smoking firemen aged 24 to 45 years had about 1 h of exposure to low and high levels of air pollution. The tests consisted of two phases: phase A, in Bertioga, a town with low levels of air pollution, and phase B, in Cubatão, a polluted town, with a 7-day interval between phases. The volunteers remained in the cities (Bertioga/Cubatão) only for the time required to perform the tests. Cumulative load 10 ± 2 min-long exertion tests were performed on a treadmill, consisting of a 2-min stage at a load of 7 km/h, followed by increasing exertion of 1 km h-1 min-1 until the maximum individual limit. There were statistically significant differences (P < 0.05) in anaerobic threshold (AT) between Cubatão (35.04 ± 4.91 mL kg-1 min-1) and Bertioga (36.98 ± 5.62 mL kg-1 min-1; P = 0.01), in the heart rate at AT (AT HR; Cubatão 152.08 ± 14.86 bpm, Bertioga 157.44 ± 13.64 bpm; P = 0.001), and in percent maximal oxygen consumption at AT (AT%VO2max; Cubatão 64.56 ± 6.55%, Bertioga 67.40 ± 5.35%; P = 0.03). However, there were no differences in VO2max, maximal heart rate or velocity at AT (ATvel) observed in firemen between towns. The acute exposure to pollutants in Cubatão, SP, caused a significant reduction in the performance at submaximal levels of physical exertion.
Resumo:
The objective of the work is to study the flow behavior and to support the design of air cleaner by dynamic simulation.In a paper printing industry, it is necessary to monitor the quality of paper when the paper is being produced. During the production, the quality of the paper can be monitored by camera. Therefore, it is necessary to keep the camera lens clean as wood particles may fall from the paper and lie on the camera lens. In this work, the behavior of the air flow and effect of the airflow on the particles at different inlet angles are simulated. Geometries of a different inlet angles of single-channel and double-channel case were constructed using ANSYS CFD Software. All the simulations were performed in ANSYS Fluent. The simulation results of single-channel and double-channel case revealed significant differences in the behavior of the flow and the particle velocity. The main conclusion from this work are in following. 1) For the single channel case the best angle was 0 degree because in that case, the air flow can keep 60% of the particles away from the lens which would otherwise stay on lens. 2) For the double channel case, the best solution was found when the angle of the first inlet was 0 degree and the angle of second inlet was 45 degree . In that case, the airflow can keep 91% of particles away from the lens which would otherwise stay on lens.
Resumo:
Various factors determine the applicability of rice husk ash (RHA) as a pozzolanic material. The amount and accessibility of reactive sites is thought to be a key factor. A structural study of RHA samples in relation to their reactivity has been performed; Silica in RHA formed by burning rice husk in a laboratory furnace under continuous supply of air have been characterized as a function of incineration temperature, time and cooling regime. The characterization methods included chemical analyses, conductivity measurements, microscopic analysis, X-ray diffraction (XRD) and 29Si magic-angle spinning (MAS) nuclear magnetic resonance (NMR). In line with earlier observations, the analyses show that the highest amounts of amorphous silica occur in samples burnt in the range of 500 °C–700 °C. The 29Si NMR data allow direct identification of the reactive silanol sites in the RHA samples. De-convolution of the NMR spectra clearly shows that the quickly cooled RHA resulting from burning rice husk for 12 h at 500 °C has the highest amount of silanol groups. This sample also induced the largest drop in conductivity when added to a saturated calcium hydroxide solution giving an indication of its reactivity towards lime. Therefore, this RHA is the favorable sample to be used as pozzolanic cement additive
Resumo:
In recent years, some epidemiologic studies have attributed adverse effects of air pollutants on health not only to particles and sulfur dioxide but also to photochemical air pollutants (nitrogen dioxide and ozone). The effects are usually small, leading to some inconsistencies in the results of the studies. Furthermore, the different methodologic approaches of the studies used has made it difficult to derive generic conclusions. We provide here a quantitative summary of the short-term effects of photochemical air pollutants on mortality in seven Spanish cities involved in the EMECAM project, using generalized additive models from analyses of single and multiple pollutants. Nitrogen dioxide and ozone data were provided by seven EMECAM cities (Barcelona, Gijón, Huelva, Madrid, Oviedo, Seville, and Valencia). Mortality indicators included daily total mortality from all causes excluding external causes, daily cardiovascular mortality, and daily respiratory mortality. Individual estimates, obtained from city-specific generalized additive Poisson autoregressive models, were combined by means of fixed effects models and, if significant heterogeneity among local estimates was found, also by random effects models. Significant positive associations were found between daily mortality (all causes and cardiovascular) and NO2, once the rest of air pollutants were taken into account. A 10 μg/m3 increase in the 24-hr average 1-day NO2 level was associated with an increase in the daily number of deaths of 0.43% [95% confidence interval(CI), –0.003–0.86%] for all causes excluding external. In the case of significant relationships, relative risks for cause-specific mortality were nearly twice as much as that for total mortality for all the photochemical pollutants. Ozone was independently related only to cardiovascular daily mortality. No independent statistically significant relationship between photochemical air pollutants and respiratory mortality was found. The results in this study suggest that, given the present levels of photochemical pollutants, people living in Spanish cities are exposed to health risks derived from air pollution
Resumo:
The humidity in the dry regions of the tropical and subtropical troposphere has a major impact on the ability of the atmosphere to radiate heat to space. The water vapour content in these regions is determined by their ``origins'', here defined as the last condensation event following air masses. Trajectory simulations are used to investigate such origins using ERA40 data for January 1993. It is shown that 96% of air parcels experience condensation within 24 days and most of the remaining 4% originate in the stratosphere. Dry air masses are shown to experience a net pressure increase since last condensation which is uniform with latitude, while the median time taken for descent is 5 days into the subtropics but exceeds 16 days into the equatorial lower troposphere. The associated rate of decrease in potential temperature is consistent with radiative cooling. The relationship between the drier regions in the tropics and subtropics and the geographical localization of their origin is investigated. Four transport processes are identified to explain these relationships.